Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Increased inflammation as well as decreased endoplasmic reticulum stress and translation differentiate pancreatic islets from donors with pre-symptomatic stage 1 type 1 diabetes and non-diabetic donors

Aims/hypothesis Progression to type 1 diabetes is associated with genetic factors, the presence of autoantibodies and a decline in beta cell insulin secretion in response to glucose. Very little is known regarding the molecular changes that occur in human insulin-secreting beta cells prior to the onset of type 1 diabetes. Herein, we applied an unbiased proteomics approach to identify changes in proteins and potential mechanisms of islet dysfunction in islet-autoantibody-positive organ donors with pre-symptomatic stage 1 type 1 diabetes (HbA1c ≤42 mmol/mol [6.0%]). We aimed to identify pathways in islets that are indicative of beta cell dysfunction. Methods Multiple islet sections were collected through laser microdissection of frozen pancreatic tissues from organ donors positive for single or multiple islet autoantibodies (AAb + , n=5), and age (±2 years)- and sex-matched non-diabetic (ND) control donors (n=5) obtained from the Network for Pancreatic Organ donors with Diabetes (nPOD). Islet sections were subjected to MS-based proteomics and analysed with label-free quantification followed by pathway and functional annotations. Results Analyses resulted in ~4500 proteins identified with low false discovery rate (<1%), with 2165 proteins reliably quantified in every islet sample. We observed large inter-donor variations that presented a challenge for statistical analysis of proteome changes between donor groups. We therefore focused on only the donors with stage 1 type 1 diabetes who were positive for multiple autoantibodies (mAAb + , n=3) and genetic risk compared with their matched ND controls (n=3) for the final statistical analysis. Approximately 10% of the proteins (n=202) were significantly different (unadjusted p<0.025, q<0.15) for mAAb + vs ND donor islets. The significant alterations clustered around major functions for upregulation in the immune response and glycolysis, and downregulation in endoplasmic reticulum (ER) stress response as well as protein translation and synthesis. The observed proteome changes were further supported by several independent published datasets, including a proteomics dataset from in vitro proinflammatory cytokine-treated human islets and single-cell RNA-seq datasets from AAb + individuals. Conclusions/interpretation In situ human islet proteome alterations in stage 1 type 1 diabetes centred around several major functional categories, including an expected increase in immune response genes (elevated antigen presentation/HLA), with decreases in protein synthesis and ER stress response, as well as compensatory metabolic response. The dataset serves as a proteomics resource for future studies on beta cell changes during type 1 diabetes progression and pathogenesis. Data availability The LC-MS raw datasets that support the findings of this study have been deposited in the online repository: MassIVE (https://massive.ucsd.edu/ProteoSAFe/static/massive.jsp) with accession no. MSV000090212.

Autoantibody-positive↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Hepatic Arterial Chemoembolization Using Drug-Eluting Beads in Gastrointestinal Neuroendocrine Tumor Metastatic to the Liver

Purpose: This study was designed to evaluate short (<3 months) and intermediate-term (>3 months) follow-up in patients with metastatic neuroendocrine tumor to the liver who underwent hepatic arterial chemoembolization with drug-eluting beads at a single institution. Methods: Institutional review board approval was obtained for this retrospective review. All patients who were treated with 100-300 or 300-500 {mu}m drug-eluting LC Beads (Biocompatibles, UK) preloaded with doxorubicin (range, 50-100 mg) for GI neuroendocrine tumor metastatic to the liver from June 2004 to June 2009 were included. CT and MRI were evaluated for progression using Response Evaluation Criteria In Solid Tumors (RECIST) or European Association for the Study of the Liver (EASL) criteria. Short-term (<3 months) and intermediate-term (>3 months) imaging response was determined and Kaplan-Meier survival curves were plotted. Results: Thirty-eight drug-eluting bead chemoembolization procedures were performed on 32 hepatic lobes, comprising 21 treatment cycles in 18 patients. All procedures were technically successful with two major complications (biliary injuries). At short-term follow-up (<3 months), 22 of 38 (58%) procedures and 10 of 21 (48%) treatment cycles produced an objective response (OR) with the remainder having stable disease (SD). At intermediate-term follow-up (mean, 445 days; range, 163-1247), 17 of 26 (65%) procedures and 8 of 14 (57%) treatment cycles produced an OR. Probability of progressing was approximately 52% at 1 year with a median time to progression of 419 days. Conclusions: Drug-eluting bead chemoembolization is a reasonable alternative to hepatic arterial embolization and chemoembolization for the treatment of metastatic neuroendocrine tumor to the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pattern of Retained Contrast on Immediate Postprocedure Computed tomography (CT) After Particle Embolization of Liver Tumors Predicts Subsequent Treatment Response

PurposeTo determine if the pattern of retained contrast on immediate postprocedure computed tomography (CT) after particle embolization of hepatic tumors predicts modified Response Evaluation Criteria in Solid Tumors (mRECIST) response.Materials and MethodsThis study was approved by the Institutional Review Board with a waiver of authorization. One hundred four liver tumors were embolized with spherical embolic agents (Embospheres, Bead Block, LC Bead) and polyvinyl alcohol. Noncontrast CT was performed immediately after embolization to assess contrast retention in the targeted tumors, and treatment response was assessed by mRECIST criteria on follow-up CT (average time 9.0 {+-} 7.7 weeks after embolization). Tumor contrast retention (TCR) was determined based on change in Hounsfield units (HUs) of the index tumors between the preprocedure and immediate postprocedure scans; vascular contrast retention (VCR) was rated; and defects in contrast retention (DCR) were also documented. The morphology of residual enhancing tumor on follow-up CT was described as partial, circumferential, or total. Association between TCR variables and tumor response were assessed using multivariate logistic regression.ResultsOf 104 hepatic tumors, 51 (49 %) tumors had complete response (CR) by mRECIST criteria; 23 (22.1 %) had partial response (PR); 21 (20.2 %) had stable disease (SD); and 9 (8.7 %) had progressive disease (PD). By multivariate analysis, TCR, VCR, and tumor size are independent predictors of CR (p = 0.02, 0.05, and 0.005 respectively). In 75 tumors, DCR was found to be an independent predictor of failure to achieve complete response (p < 0.0001) by imaging criteria.ConclusionTCR, VCR, and DCR on immediate posttreatment CT are independent predictors of CR by mRECIST criteria.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct determination of cellulosic glucan content in starch-containing samples

A simple and highly selective analytical procedure is presented for the determination of cellulosic glucan content in samples that contain both cellulose and starch. This method eliminates the unacceptably large compounding errors of current two-measurement methods. If both starch and cellulose are present before analytical hydrolysis, both will be hydrolyzed to glucose causing bias and inaccuracy in the method. To prevent this interference, the removal of starch prior to cellulosic quantification is crucial. The method presented here is a concise in-series procedure with minimal measurements, eliminating large compounding errors. Sample preparation consists of a starch extraction employing enzymatic hydrolysis followed by a simple filtration and wash. The samples are then subjected to a two-stage acid hydrolysis. The concentration of glucose is determined by ion exchange high-performance liquid chromatography with a Pb 2+ column and a refractive index detector. The cellulosic glucan content is calculated based on the initial dry weight of the starting material. Data for the native biomass materials studied show excellent reproducibility, with coefficients of variance of 3.0% or less associated with the method. This selectivity for cellulosic glucan by the procedure was validated with several analytical techniques such as liquid chromatography coupled with mass spectrometry (LC–MS), Raman spectroscopy, and nuclear magnetic resonance.

09 BIOMASS FUELS↗

Ultrafast Relaxation of Charge Carriers Induced Switching in Terahertz Metamaterials

Here, we demonstrate ultrafast switching of resonant mode in terahertz metamaterials through optical excitation of radiation-damaged silicon placed in the gap of a split-ring resonator. Upon optical excitation, we observe the dynamic transition of the fundamental resonance from ON-to-OFF state on a timescale of 4 picoseconds (ps) and then fast recovery of the resonance to the ON-state within the next 20 ps. Electric field distributions in the metamaterial unit cell derived through numerical simulations clearly support our experimental observations, showing that the high electric field at the resonator gaps, responsible for inductive-capacitive (LC) resonance, completely disappears and switches OFF the resonance after being optically excited. The ultrafast switching of the metamaterial resonance is attributed to the relaxation of the photo-carriers through the defect states of radiation-damaged silicon layer. Such ultrafast material–based active control of metamaterials can lead to the ultrafast terahertz metaphotonic devices.

36 MATERIALS SCIENCE↗

Synthesis and Spectroscopic Studies of Phenanthroimidazole-Imine Derivatives and Evaluation of Their Antioxidant Activity

The phenanthroimidazole derivatives are used in the drug industry in large scale. In this study four new phenanthroimidazole-imine derivatives were synthesized and their spectroscopic studies as well as their antioxidant behaviors were examined. Structural analyses were made by FT-IR, {sup 1}H-NMR, {sup 13}C-NMR, LC-MS spectroscopy techniques. UV–vis absorption and emission spectroscopy techniques have been used to determine the photophysical characteristics of four newly synthesized phenanthroimidazoles. The maximum absorption and emission wavelengths, molar extinction coefficients (ε), singlet energy levels (Es), Stokes’ shift values (Δλ) of phenanthroimidazole-imine derivatives are given. Additionally, the antioxidant behavior of all compounds were investigated which the ascorbic acid used as standard molecule in present study.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of readout electronics for POLARBEAR-2 cosmic microwave background experiment

The readout of transition-edge sensor (TES) bolometers with a large multiplexing factor is key for the next generation cosmic microwave background (CMB) experiment, Polarbear-2, having 7588 TES bolometers. To enable the large arrays, we have been developing a readout system with a multiplexing factor of 40 in the frequency domain. Extending that architecture to 40 bolometers requires an increase in the bandwidth of the SQUID electronics, above 4 MHz. This paper focuses on cryogenic readout and shows how it affects cross talk and the responsivity of the TES bolometers. A series resistance, such as equivalent series resistance of capacitors for LC filters, leads to non-linear response of the bolometers. A wiring inductance modulates a voltage across the bolometers and causes cross talk. They should be controlled well to reduce systematic errors in CMB observations. As a result, we have been developing a cryogenic readout with a low series impedance and have tuned bolometers in the middle of their transition at a high frequency (>3 MHz).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exchange interaction mechanisms in 1,3,5,7-tetramethyl-2,6-diazaadamantane N,N’-dioxyl biradical

The exchange interaction parameters were calculated and the spin density distribution over the organic skeleton of the 1,3,5,7-tetramethyl-2,6-diazaadamantane N,N’-dioxyl biradical was studied based on the results of quantum chemical modeling of the biradical structure by the DFT method using various hybrid functionals (UB3LYP, LC-wPBE, UCAM-B3LYP, UHSEH1PBE) with the 6-311++G(2d,2p) basis set and by the UHF method with the same basis set. The characteristics of the direct orbital overlap between the N atoms of the two nitroxide groups were determined. The values of the J constant, obtained using different calculation methods, were found to be similar to each other. It was established that there is ferromagnetic exchange interaction between the radical sites in the system in question, which occurs predominantly according to the spin polarization mechanism in the 2,6-diazaadamantane core, and the various spin density transfer pathways through the C atoms of the organic skeleton were found to be nonequivalent. The direct overlap of the upper singly-occupied МОs with localization on the nitroxide groups led to a noticeable additional contribution of the antiferromagnetic exchange interaction. Despite the latter factor, the total contribution of these two mechanisms (spin polarization and direct through-space exchange) resulted in the triplet ground state in the biradical studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Holographic Formation of Diffraction Elements for Transformation of Light Beams in Liquid Crystal – Photopolymer Compositions

A theoretical model of holographic formation of diffractive optical elements for transformation of light beam field into Bessel-like fields in liquid crystal – photopolymer (LC–PPM) composite materials with a dyesensitizer is developed. Results of numerical modeling of kinetics ofvariation of the refractive index of a material in the process of formation with different relationships between the photopolymerization rates and diffusion processes are presented. Based on the results of numerical simulation, it is demonstrated that when the photopolarization process dominates, the diffractive element being formed is distorted. This leads to a change in the light field distribution at its output and consequently, to ineffective transformation of the reading beam. Thus, the necessity of optimizing of the recording conditions and of the prepolymeric composition to increase the transformation efficiency of light beam fields is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metabolomic and transcriptomic analysis of the rice response to the bacterial blight pathogen Xanthomonas oryzae pv. oryzae

Bacterial leaf blight (BLB), caused by Xanthomonas oryzae pv. oryzae (Xoo), gives rise to devastating crop losses in rice. Disease resistant rice cultivars are the most economical way to combat the disease. The TP309 cultivar is susceptible to infection by Xoo strain PXO99. A transgenic variety, TP309_Xa21, expresses the pattern recognition receptor Xa21, and is resistant. PXO994raxST, a strain lacking the raxST gene, is able to overcome Xa21-mediated immunity. We used a single extraction solvent to demonstrate comprehensive metabolomics and transcriptomics profiling under sample limited conditions, and analyze the molecular responses of two rice lines challenged with either PXO99 or PXO994raxST. LC–TOF raw data file filtering resulted in better within group reproducibility of replicate samples for statistical analyses. Accurate mass match compound identification with molecular formula generation (MFG) ranking of 355 masses was achieved with the METLIN database. GC–TOF analysis yielded an additional 441 compounds after BinBase database processing, of which 154 were structurally identified by retention index/MS library matching. Multivariate statistics revealed that the susceptible and resistant genotypes possess distinct profiles. Although few mRNA and metabolite differences were detected in PXO99 challenged TP309 compared to mock, many differential changes occurred in the Xa21-mediated response to PXO99 and PXO994raxST. Acetophenone, xanthophylls, fatty acids, alkaloids, glutathione, carbohydrate and lipid biosynthetic pathways were affected. Significant transcriptional induction of several pathogenesis related genes in Xa21 challenged strains, as well as differential changes to GAD, PAL, ICL1 and Glutathione-S-transferase transcripts indicated limited correlation with metabolite changes under single time point global profiling conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Isocitrate dehydrogenase gene mutations and 2-hydroxyglutarate accumulation in esophageal squamous cell carcinoma

Isocitrate dehydrogenase 1 and 2 (IDH1 and IDH2) are key metabolic enzymes that convert isocitrate to α-ketoglutarate. Somatic point mutations in IDH1/2 confer a gain-of-function in cancer cells, resulting in overproduction of an oncometabolite, 2-hydroxyglutarate (2HG). 2HG interferes with cellular metabolism and epigenetic regulation, contributing to oncogenesis. Given that IDH1 and IDH2 are attracting attention as promising therapeutic targets, better evaluation of the incidence of IDH1 and IDH2 mutations and 2HG level in human cancers is clinically important. This is the first study to assess their incidence in esophageal squamous cell carcinomas (ESCCs). First, we established pyrosequencing assays for IDH1 and IDH2 mutations and revealed that these mutations were absent in 10 ESCC cell lines and 96 ESCC tissues. Second, utilizing IDH1 and IDH2 overexpression vectors, we demonstrated that LC-MS/MS assays can accurately evaluate 2HG level and found that some ESCC cases presented a high level of 2HG. In conclusion, IDH1 or IDH2 mutations play a limited role in the development of ESCC. 2HG is potentially synthesized to high levels in the absence of IDH1 and IDH2 mutations, and this may correlate with progression of ESCCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics

Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed by identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.

Environmental Molecular Sciences Laboratory↗

Isotope-Encoded Carboxyl Group Footprinting for Mass Spectrometry-Based Protein Conformational Studies

Here, we report an isotope-encoding method coupled with carboxyl-group footprinting to monitor protein conformational changes. The carboxyl groups of aspartic/glutamic acids and of the C-terminus of proteins can serve as reporters for protein conformational changes when labeled with glycine ethyl ester (GEE) mediated by carbodiimide. In the new development, isotope-encoded “heavy” and “light” GEE are used to label separately the two states of the orange carotenoid protein (OCP) from cyanobacteria. Two samples are mixed (1:1 ratio) and analyzed by a single LC-MS/MS experiment. The differences in labeling extent between the two states are represented by the ratio of the “heavy” and “light” peptides, providing information about protein conformational changes. Combining isotope-encoded MS quantitative analysis and carboxyl-group footprinting reduces the time of MS analysis and improves the sensitivity of GEE and other footprinting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Retrospective Evaluation of the Use of Mass Spectrometry in FDA Biologics License Applications

The characterization sections of biologics license applications (BLAs) approved by the United States Food and Drug Administration (FDA) between 2000 and 2015 were investigated to examine the extent of the use of mass spectrometry. Mass spectrometry was found to be integral to the characterization of these biotherapeutics. Of the 80 electronically submitted monoclonal antibody and protein biotherapeutic BLAs included in this study, 79 were found to use mass spectrometric workflows for protein or impurity characterization. To further examine how MS is being used in successful BLAs, the applications were filtered based on the type and number of quality attributes characterized, the mass spectrometric workflows used (peptide mapping, intact mass analysis, and cleaved glycan analysis), the methods used to introduce the proteins into the gas phase (ESI, MALDI, or LC-ESI), and the specific types of instrumentation used. Analyses were conducted over a time course based on the FDA BLA approval to determine if any trends in utilization could be observed over time. Additionally, the different classes of protein-based biotherapeutics among the approved BLAs were clustered to determine if any trends could be attributed to the specific type of biotherapeutic. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Transfer Dissociation of All Ions at All Times, MS{sup ETD}, in a Quadrupole Time-of-Flight (Q-ToF) Mass Spectrometer

Data-independent mass spectral acquisition is particularly powerful when combined with ultra-performance liquid chromatography (LC) that provides excellent separation of most components present in a given sample. Data-independent analysis (DIA) consists of alternating full MS scans and scans with fragmentation of all ions within a selected m/z range, providing precursor masses and structure information, respectively. Fragmentation spectra are acquired either by sequential isolation and fragmentation of sliding m/z ranges or fragmenting all ions entering the MS instrument with no ion isolation, termed broadband DIA. Previously, broadband DIA has only been possible using collision induced dissociation (CID). Here, we report the use of electron transfer dissociation (ETD) as the fragmentation technique in broadband DIA instead of traditional collision induced dissociation (CID) during MS{sup E}. In this approach, which we refer to as MS{sup ETD}, we implement the inherent benefits provided by ETD, such as discrimination of leucine and isoleucine, in a DIA setup. The combination of DIA analysis and ETD fragmentation with supplemental CID energy provides a powerful platform to obtain information on all precursors and their sequence from a single experiment. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗