Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrument optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Dynamic systems modeling of the spallation neutron source cryogenic moderator system to optimize transient control and prepare for power upgrades

Through support of the US Department of Energy's Office of Basic Energy Sciences, Oak Ridge National Laboratory has begun applying machine learning methods to improve accelerator and target performance of the Spallation Neutron Source (SNS). These methods are being applied to the control optimization and power upgrade of the SNS Cryogenic Moderator System (CMS). A numerical model of the CMS has been developed to study these optimizations and system modifications using EcosimPro. This paper compares steady-state and transient numerical results with experimental data. Control optimization studies focused on dampening mass flow, temperature, and pressure fluctuations during sudden losses of accelerator beam power. This analysis was conducted by adjusting five proportional-integral-derivative controllers connected to four flow control valves and one heater. Future efforts include power uprate studies focused on increasing the CMS cooling capacity. The current accelerator power is 1.4 MW; the first target station is being upgraded to 2.0 MW as part of the Proton Power Upgrade effort. The CMS cooling capacity is sufficient for 2.0 MW operation.

47 OTHER INSTRUMENTATION↗

Science & Technology Review December 2025 - Optimizing Future Design

At Lawrence Livermore National Laboratory, we focus on science and technology research to ensure our nation’s security. We also apply that expertise to solve other important national problems in energy, bioscience, and the environment. Science & Technology Review is published eight times a year to communicate, to a broad audience, the Laboratory’s scientific and technological accomplishments in fulfilling its primary missions. The publication’s goal is to help readers understand these accomplishments and appreciate their value to the individual citizen, the nation, and the world.

36 MATERIALS SCIENCE↗

Simulating Continuum-based Redshift Measurement in the Roman’s High Latitude Spectroscopic Survey

We investigate the capability of the Nancy Grace Roman Space Telescope’s (Roman) Wide-Field Instrument G150 slitless grism to detect red, quiescent galaxies based on the current reference survey. We simulate dispersed images for Roman reference High-Latitude Spectroscopic Survey (HLSS) and analyze two-dimensional spectroscopic data using the grism Redshift and Line Analysis (Grizli) software. This study focus on assessing Roman grism’s capability for continuum-level redshift measurement for a redshift range of 0.5 ≤ z ≤ 2.5. The redshift recovery is assessed by setting three requirements of: σ z = $\frac{|z–z_{true}|}{1+z}$ ≤ 0.01, signal-to-noise ratio≥ 5 and the presence of a single dominant peak in redshift likelihood function. We find that, for quiescent galaxies, the reference HLSS can reach a redshift recovery completeness of ≥50% for F158 magnitude brighter than 20.2 mag. We also explore how different survey parameters, such as exposure time and the number of exposures, influence the accuracy and completeness of redshift recovery, providing insights that could optimize future survey strategies and enhance the scientific yield of the Roman in cosmological research.

Astronomical simulations↗

Constraining primordial non-Gaussianity from DESI DR1 quasars and Planck PR4 CMB lensing

We present the first measurement of local-type primordial non-Gaussianity from the cross-correlation between 1.2 million spectroscopically confirmed quasars from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI) and the Planck PR4 CMB lensing reconstructions. The analysis is performed in three tomographic redshift bins covering 0.8 < z < 3.5, covering a sky fraction of ∼20%. We adopt a catalog-based pseudo-C ℓ estimator and apply linear imaging weights validated on noiseless mocks. Compared to previous analyses using photometric quasar samples, our results benefit from the high purity of the DESI spectroscopic sample, the reduced noise of PR4 lensing, and the absence of excess large-scale power in the spectroscopic quasar auto-correlation. Fitting simultaneously for the non-Gaussianity parameter f NL and the linear bias amplitude in each redshift bin, we obtain f NL = 2 +28 -34 for a response parameter p = 1.6, and f NL = 6 +20 -24 for p = 1.0. These results improve the constraints on f NL by ∼35% compared to the previous analysis based on the Legacy Imaging Survey DR9. Additionally, we derive an optimal weighting scheme to maximize the constraining power. In this case, and assuming p = 1.6, we obtain f NL = 19 +25 -31 . Our results demonstrate the statistical power of DESI quasars for probing inflationary physics, and highlight the promise of future DESI data releases.

cosmological parameters from CMBR↗

RAPIDS: Reconciling Availability, Accuracy, and Performance in Managing Geo-Distributed Scientific Data

In modern science, big data plays an increasingly important role. Many scientific applications, such as running simulations on supercomputers or conducting experiments on advanced instruments, produce huge amount of data at unprecedented speed. Analyzing and understanding such big data is the key for scientists to make scientific breakthroughs. However, data might become unavailable for scientists to access when outages or maintenance of the storage system occur, which severely hinders scientific discovery. To improve the data availability, data duplication and erasure coding (EC) are often used. But as the scientific data gets larger, using these two methods can cause considerable storage and network overhead.In this paper, we propose RAPIDS, a hybrid approach that combines the multigrid-based error-bounded lossy compression with erasure coding, to significantly reduce the storage and network overhead required for maintaining high data availability. Our experiments show that RAPIDS reduces the storage overhead by up to 7.5x and network overhead by up to 3x to achieve the same level of availability compared to the regular EC method. We improve RAPIDS by building two models to optimize the fault tolerance configurations and data gathering strategy. We demonstrate that RAPIDS significantly improves performance when running on many CPU cores in parallel or on GPUs.

Wan, Lipeng↗

Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments, Part II: On-line studies with short-lived accelerator-produced radionuclides

We report a novel combination of advanced gas-chromatography and detection systems coupled to a buffer-gas cell was characterized on-line to allow gas-phase chemical studies of accelerator-produced short-lived α -decaying mercury, francium, and astatine isotopes. These were produced in 40 Ar- and 48 Ca-induced nuclear fusion–evaporation reactions, subsequently isolated in the recoil separators MARS at Texas A&M University, USA, and TASCA at GSI Darmstadt, Germany, before being thermalized in a buffer-gas-stopping cell. From the latter, the nuclear reaction products were extracted into gas-phase chromatographic systems, suitable for registering α-decaying short-lived radionuclides, such as isotopes of superheavy elements. Efficiencies of 21(3)% for 204-209 Fr were reached for the extraction into the optimized miniCOMPACT gas-chromatography setup, indicating that this technique enables the identification of isotopes of volatile as well as non-volatile elements. These studies guide the path towards chemical investigations of superheavy elements beyond flerovium, which are out of reach with currently used setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying Leaf Chlorophyll Concentration of Sorghum from Hyperspectral Data Using Derivative Calculus and Machine Learning

Leaf chlorophyll concentration (LCC) is an important indicator of plant health, vigor, physiological status, productivity, and nutrient deficiencies. Hyperspectral spectroscopy at leaf level has been widely used to estimate LCC accurately and non-destructively. This study utilized leaf-level hyperspectral data with derivative calculus and machine learning to estimate LCC of sorghum. We calculated fractional derivative (FD) orders starting from 0.2 to 2.0 with 0.2 order increments. Additionally, 43 common vegetation indices (VIs) were calculated from leaf spectral reflectance factor to make comparisons with reflectance-based data. Within the modeling pipeline, three feature selection methods were assessed: Pearson’s correlation coefficient (PCC), partial least squares based variable importance in the projection (VIP), and random forest-based mean decrease impurity (MDI). Finally, we used partial least squares regression (PLSR), random forest regression (RFR), support vector regression (SVR), and extreme learning regression (ELR) to estimate the LCC of sorghum. Results showed that: (1) increasing derivative order can show improved model performance until certain order for reflectance-based analysis; however, it is inconclusive to state that a particular order is optimal for estimating LCC of sorghum; (2) VI-based modeling outperformed derivative augmented reflectance factor-based modeling; (3) mean decrease impurity was found effective in selecting sensitive features from large feature space (reflectance-based analysis), whereas simple Pearson’s correlation coefficient worked better with smaller feature space (VI-based analysis); and (4) SVR outperformed all other models within reflectance-based analysis; alternatively, ELR with VIs from original reflectance yielded slightly better results compared to all other models.

47 OTHER INSTRUMENTATION↗

Development of Short-Term Forecasting Models Using Plant Asset Data and Feature Selection

Nuclear power plants collect and store large volumes of heterogeneous data from various components and systems. With recent advances in machine learning (ML) techniques, these data can be leveraged to develop diagnostic and short-term forecasting models to better predict future equipment condition. Maintenance operations can then be planned in advance whenever degraded performance is predicted, thus resulting in fewer unplanned outages and the optimization of maintenance activities. This enables lower maintenance costs and improves the overall economics of nuclear power. This paper focuses on developing a short-term forecasting process that leverages a feature selection process to distill large volumes of heterogeneous data and predict specific equipment parameters. A variety of feature selection methods, including Shapley Additive Explanations (SHAP) and variance inflation factor (VIF), were used to select the optimal features as inputs for three ML methods: long short-term memory (LSTM) networks, support vector regression (SVR), and random forest (RF). Each combination of model and input features was used to predict a pump bearing temperature both 1 and 24 hours in advance, based on actual plant system data. The optimal inputs for the LSTM and SVR were selected using the SHAP values, while the optimal input for the RF consisted solely of the response variable itself. Each model produced similar 1-hour-ahead predictions, with root mean square errors (RMSEs) of roughly 0.006. For the 24-hour-ahead predictions, differences could be seen between LSTM, SVR, and RF, as reflected by model performances of 0.036 +- 0.014, 0.0026 +- 0, and 0.063 +- 0.004 RMSE, respectively. As big data and continuous online monitoring become more widely available, the proposed feature selection process can be used for many applications beyond the prediction of process parameters within nuclear infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian Optimal Sensor Augmentation Via Estimated Mutual Information

We consider the problem of designing a sensor network to most efficiently locate the source of a seismic event. The left panel of Figure 1 shows 982 possible sensor locations in a region of interest. The objective is to infer the unknown location of an earthquake, indicated by the gold dot for illustration purposes. Assume that three sensors have already been placed for data collection. Travel times of the P-wave from the source to the three sensors are observed and used to infer the unknown source location via a Bayesian statistical model described subsequently. The right panel of Figure 1 shows samples from the resulting posterior distribution for source location along with a posterior estimate of this location.

47 OTHER INSTRUMENTATION↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Black-Box Optimization for Design of Concentrating Solar Power and Photovoltaic Hybrid Systems with Optimal Dispatch Decisions

The hybridization of concentrating solar power (CSP) and photovoltaics (PV) can enable dispatchable renewable electricity generation at a lower price than current stand-alone CSP systems. However, designing a CSP-PV hybrid system can be challenging because of the many degrees of freedom in design that affect the internal and external system interactions and trade-offs. We develop a methodology to determine optimal designs for CSP-PV hybrids by implementing NLopt's derivative-free, or “black-box,” algorithms around pre-existing CSP-PV hybrid simulation software that utilizes the National Renewable Energy Laboratory’s System Advisor Model (SAM); we then employ a dispatch optimization model to determine operational decisions that maximize a plant’s profits. We present optimal designs for CSP-PV hybrid systems dispatching against four time-of-delivery (ToD) pricing structures. NLopt’s algorithms can improve the base case design’s power purchase agreement (PPA) price by 15% to 21%, depending on the ToD pricing structure. In addition, we present the resulting optimal CSP-PV hybrid design’s annual performance metrics, which tend to have capacity factors between 50% and 62%, but are able to generate electricity during the year’s highest-valued periods about 90% of the time. Lastly, we investigate the trade-offs between capacity factor and PPA price using Pareto fronts and demonstrate that, for some ToD pricing structures, the system capacity factor can increase by 20% but at the expense of a 2% increase in PPA price.

black-box↗

The DESI Bright Galaxy Survey: Final Target Selection, Design, and Validation

Over the next 5 yr, the Dark Energy Spectroscopic Instrument (DESI) will use 10 spectrographs with 5000 fibers on the 4 m Mayall Telescope at Kitt Peak National Observatory to conduct the first Stage IV dark energy galaxy survey. At z < 0.6, the DESI Bright Galaxy Survey (BGS) will produce the most detailed map of the universe during the dark-energy-dominated epoch with redshifts of >10 million galaxies spanning 14,000 deg 2 . In this work, we present and validate the final BGS target selection and survey design. From the Legacy Surveys, BGS will target an r < 19.5 mag limited sample (BGS Bright), a fainter 19.5 < r < 20.175 color-selected sample (BGS Faint), and a smaller low-z quasar sample. BGS will observe these targets using exposure times scaled to achieve homogeneous completeness and cover the footprint three times. We use observations from the Survey Validation programs conducted prior to the main survey along with simulations to show that BGS can complete its strategy and make optimal use of "bright" time. BGS targets have stellar contamination <1%, and their densities do not depend strongly on imaging properties. BGS Bright will achieve >80% fiber assignment efficiency. Finally, BGS Bright and BGS Faint will achieve >95% redshift success over any observing condition. BGS meets the requirements for an extensive range of scientific applications. BGS will yield the most precise baryon acoustic oscillation and redshift-space distortion measurements at z < 0.4. It presents opportunities for new methods that require highly complete and dense samples (e.g., N-point statistics, multitracers). BGS further provides a powerful tool to study galaxy populations and the relations between galaxies and dark matter.

79 ASTRONOMY AND ASTROPHYSICS↗

A high-volume resonator for L-band DNP-NMR

DNP-NMR and EPR experiments that operate at or greater than L-band (i.e., ν 0 (e – ) = 1–2 GHz) are typically limited to maximum sample volumes of several hundred µL. These experiments rely on well-known resonator designs for DNP/EPR irradiation such as the loop-gap resonator and Alderman-Grant coil, where their maximum volumes limit further application to imaging experiments and high-throughput screening beyond L-band. Herein, we demonstrate a birdcage (BC) resonator design that can accommodate several mL of sample while operating around 1.5 GHz. The sample volume is maximized by using two identical BC resonators in a stacked configuration. Simulations are used to optimize the BC design and the performance is validated experimentally with liquid-state Overhauser-DNP-NMR experiments. This BC design exploits just the parasitic capacitance of conductive rings and features no fixed tuning capacitors. An enhancement of –77 is achieved on a 10 mM 4-Amino-TEMPO in H 2 O sample for a 5 mL sample volume. Finally, the associated sample heating is minimal due to the low-E-fields generated and the large sample mass with +3.4 K when driving 100 W for several seconds.

47 OTHER INSTRUMENTATION↗

Characterization and Optimization of a Spectral Window for Direct Gaseous Uranium Hexafluoride Enrichment Assay Using Laser-Induced Breakdown Spectroscopy

Through a systematic scanning of 235 U and 238 U emission lines between 280 nm and 745 nm, the optimal emission line for direct gaseous uranium hexafluoride (UF 6 ) enrichment assay using laser-induced breakdown spectroscopy (LIBS) was found. Screening for spectral features that are potentially useful for U isotopic analysis was gauged from the magnitude of the 235 U– 238 U isotopic shift and the signal-to-background ratio of the emission line through a parameter termed ΔSBR 235U–238U . The ΔSBR spectrum shows peaks at wavelength positions where there are strong lines with significant 235 U– 238 U shifts. The screening identified 13 spectral-window candidates, which were down selected based on their overall accuracy in predicting the 235 U enrichment of three UF 6 samples of natural (0.720 atom% 235 U) and low-enriched (4.675 atom% and 9.157 atom% 235 U) grades. The U(I) 646.498 nm emission line, with a determined 235 U– 238 U isotopic shift of -17.7 pm, was found to be the optimal spectral window for direct UF 6 enrichment assay. The root mean square error for enrichment assays on the three natural and low-enriched UF 6 samples, with each sample measured in six replicates, was 0.31% in absolute 235 U content. Each measurement comprised LIBS signals accumulated from 3000 laser shots. In conclusion, the analytical bias and precision were better than 0.5% and 0.3%, respectively, in absolute [ 235 U/( 235 U + 238 U)] ratios. Specific for the two low-enriched UF 6 samples, the relative standard deviations from six replicated measurements were around 2%.

47 OTHER INSTRUMENTATION↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration improvements expand filterscope diagnostic use

The filterscope diagnostic on DIII-D utilizes photomultiplier tubes to measure visible light emission from the plasma. The system has undergone a substantial upgrade since previous attempts to cross-calibrate the filterscope with other spectroscopic diagnostics were unsuccessful. The optics now utilize a dichroic mirror to initially split the light at nearly 99% transmission or reflectance for light below or above 550 nm. This allows the system to measure D α emission without degrading visible light emission from the plasma for wavelengths below 550 nm (to measure D β , D γ , W–I, C-III, etc.). Additional optimization of the optical components and calibration techniques reduce the error in the signal up to 10% in some channels compared to previous methods. Cross-calibration measurements with two other high resolution spectroscopic diagnostics now show excellent agreement for the first time. This expands the capabilities of the filterscope system allowing measurement of divertor detachment, emission profiles, edge-localized mode behavior, and plasma–wall interactions. Additionally, it enables direct comparisons against calculations from boundary plasma simulations. These were not possible before.

47 OTHER INSTRUMENTATION↗