Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Injection testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Effect of Computational Schemes on Coupled Flow and Geo-Mechanical Modeling of CO 2 Leakage through a Compromised Well

Carbon capture, utilization, and storage (CCUS) describes a set of technically viable processes to separate carbon dioxide (CO 2 ) from industrial byproduct streams and inject it into deep geologic formations for long-term storage. Legacy wells located within the spatial domain of new injection and production activities represent potential pathways for fluids (i.e., CO 2 and aqueous phase) to leak through compromised components (e.g., through fractures or micro-annulus pathways). The finite element (FE) method is a well-established numerical approach to simulate the coupling between multi-phase fluid flow and solid phase deformation interactions that occur in a compromised well system. We assumed the spatial domain consists of a three-phases system: a solid, liquid, and gas phase. For flow in the two fluids phases, we considered two sets of primary variables: the first considering capillary pressure and gas pressure (PP) scheme, and the second considering liquid pressure and gas saturation (PS) scheme. Fluid phases were coupled with the solid phase using the full coupling (i.e., monolithic coupling) and iterative coupling (i.e., sequential coupling) approaches. The challenge of achieving numerical stability in the coupled formulation in heterogeneous media was addressed using the mass lumping and the upwinding techniques. Numerical results were compared with three benchmark problems to assess the performance of coupled FE solutions: 1D Terzaghi’s consolidation, Liakopoulos experiments, and the Kueper and Frind experiments. We found good agreement between our results and the three benchmark problems. For the Kueper and Frind test, the PP scheme successfully captured the observed experimental response of the non-aqueous phase infiltration, in contrast to the PS scheme. These exercises demonstrate the importance of fluid phase primary variable selection for heterogeneous porous media. We then applied the developed model to the hypothetical case of leakage along a compromised well representing a heterogeneous media. Considering the mass lumping and the upwinding techniques, both the monotonic and the sequential coupling provided identical results, but mass lumping was needed to avoid numerical instabilities in the sequential coupling. Additionally, in the monolithic coupling, the magnitude of primary variables in the coupled solution without mass lumping and the upwinding is higher, which is essential for the risk-based analyses.

deformation flow↗

Geologic Characterization for CO 2 Storage with Enhanced Oil Recovery in Northern Michigan

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. This report compiles the results of geologic characterization of late-stage reefs, active EOR reefs, and new EOR reefs in the Northern Niagaran Pinnacle Reef Trend (NNPRT) in Michigan to demonstrate developed methodologies, geologic variability, and reservoir potential for CO 2 storage. Conducting CO 2 injection and monitoring in these settings provide significant insights for addressing the project objectives: assessment of injectivity in complex carbonate reef deposits; assessing CO 2 trapping mechanisms in a closed reservoir system; assessing any final oil recovery from transitional or residual oil zones in a field where CO 2 flooding is nearing completion; evaluating the transition from EOR to storage of CO 2 ; assessing regional commercialization; assessing new technologies for tracking CO 2 , brine, and oil movements underground; and monitoring options in a closed reservoir with oil, residual oil, and water zones.

01 COAL, LIGNITE, AND PEAT↗

Assessment and Simulation of Particulate Transport for Delivery of Solid Amendments into the Subsurface: FY25 Status Report

For particulate-based amendments to be viable for field-scale remediation at the Hanford Site (e.g., the 200 DV-1 Operable Unit), amendment particles need to be delivered a reasonable distance away from an injection well to provide cost effective in situ treatment. Field-scale particle transport models can estimate spatial deposition of amendment particles in the subsurface, which is critical for developing an overall remediation strategy. However, field-scale particle simulations are currently limited due to insufficient simulation capability and a lack of experimental data to validate and parameterize particle transport models. During this fiscal year, the following progress has been made toward a field-scale particle transport modeling evaluation: (1) in addition to the two particle transport models implemented last FY, four additional particle transport models have been implemented within PFLOTRAN; (2) a Python-based pre-screening tool was finalized, enabling users to quickly estimate the particle radius of influence (ROI) for any given particle-amendment system; and (3) an initial compatibility assessment was completed using both particle transport simulations deployed through the pre-screening tool, in conjunction with general guidelines to (a) identify the most suitable amendment particle sizes for various Hanford sediments and (b) evaluate amendment-delivery fluid compatibility. The preliminary compatibility assessment revealed that for amendment delivery success to the various Hanford target formations, amendment particle sizes will likely need to be smaller than the amendment sizes tested in the DV-1 treatability study. It is recommended that amendment particles be decreased in size, or alternative smaller size amendments be obtained from the manufacture, prior to any further experimental testing. Also, preliminary testing suggests that xanthan gum may be the most broadly compatible delivery fluid. Planned laboratory experiments will be instrumental in validating and refining the PFLOTRAN particulate transport model formulations, ultimately enabling predictive capabilities to facilitate the design of field-scale amendment delivery systems. This work consists of acquiring new theoretical or experimental knowledge. The information associated with this report should not be used as design input or operating parameters without additional qualification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A data-driven sensor placement approach for detecting voltage violations in distribution systems

Stochastic fluctuations in power injections from distributed energy resources (DERs) combined with load variability can cause constraint violations (e.g., exceeded voltage limits) in electric distribution systems. To monitor grid operations, sensors are placed to measure important quantities such as the voltage magnitudes. Here, in this paper, we consider a sensor placement problem which seeks to identify locations for installing sensors that can capture all possible violations of voltage magnitude limits. We formulate a bilevel optimization problem that minimizes the number of sensors and avoids false sensor alarms in the upper level while ensuring detection of any voltage violations in the lower level. This problem is challenging due to the nonlinearity of the power flow equations and the presence of binary variables. Accordingly, we employ recently developed conservative linear approximations of the power flow equations that overestimate or underestimate the voltage magnitudes. By replacing the nonlinear power flow equations with conservative linear approximations, we can ensure that the resulting sensor locations and thresholds are sufficient to identify any constraint violations. Additionally, we apply various problem reformulations to significantly improve computational tractability while simultaneously ensuring an appropriate placement of sensors. Lastly, we improve the quality of the results via an approximate gradient descent method that adjusts the sensor thresholds. We demonstrate the effectiveness of our proposed method for several test cases, including a system with multiple switching configurations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ducted Fuel Injection And Cooled Spray Technologies For Particulate Control In Heavy-duty Diesel Engines (Final Report)

Cooled Spray (CS) and Ducted Fuel Injection (DFI) are in-cylinder technologies for diesel engines that can reduce particulate matter and soot emissions and data has been published showing that these technologies can reduce soot emissions by 75-100% for some engines at some operating conditions. However, little is known about scaling the devices for engine size. Additionally, the performance of either technology over the engine duty cycle has not been explored. This project addresses both of these points through single-cylinder engine investigations. The objectives of this project are to provide details about dimensional scaling of these devices and to demonstrate 75% PM reduction over a range of operating conditions on a single-cylinder engine. Two engines were used for this project: a 125mm bore optically accessible engine at Sandia National Laboratories and a 168mm bore metal engine at Southwest Research Institute. The optical engine was used to study the performance of DFI and CS inserts for a large injector orifice diameter injector that is characteristic of a locomotive engine and to perform scaling studies for DFI. The metal engine was used to perform scaling and alignment studies for CS and to evaluate the technology for both EGR and non-EGR engines over the engine operating map. Modifications were required for both engines to accept the prototype inserts being tested. The optical engine required a new fuel injector, cylinder head and piston so that tests could be run at the pressures and engine speeds required. Additionally, a novel rotating stage was designed for the optical engine to simplify alignment of the modules. The metal engine required a modified cylinder head to accept CS inserts and a modified piston to provide additional space around the fuel injector for the CS inserts. Tests on the optical engine showed that DFI reduces PM emissions for both small injector orifices (0.170mm diameter) and large injector orifices (0.290mm). For high load testing, the DFI modules were not as effective as at low load testing, but it was acknowledged that minimal geometric optimization was performed and more improvements may be possible. Comparing DFI to CS and conventional diesel combustion (CDC), DFI performed better than CS or CDC. The CS geometries used in these studies may not be ideal for that engine and additional modifications likely would improve performance. Tests on the metal engine showed PM reductions as high has 80% at some operating conditions with duty-cycle PM reductions of ~50% for EGR and non-EGR configurations. The CS testing on the metal engine showed that chamfering of the fuel passage inlet either through hydro-erosion or mechanical grinding provided significant improvements in the PM reduction capabilities of the insert. Additionally, alignment sensitivities were explored and the data show that the tolerance to misalignment is approximately 0.05 to 0.1mm for the inserts that were studied here. Air-fuel ratio was shown to be important in the effectiveness of the CS inserts. In several tests, it was shown that the CS inserts are more effective at reducing the PM for high-AFR operating conditions compared to low AFR conditions. In summary, multiple designs were evaluated on both engines. It was found that for the conditions and configurations studied here, a fuel passage diameter of ~2.5mm performed best overall. Significant duty-cycle PM reductions are possible using these technologies and sensitivities to AFR, alignment fuel passage diameter and inlet fuel passage shaping were explored and are reported here. More PM reduction may be possible with improved geometric design and attention to alignment practices.

02 PETROLEUM↗

High Temperature Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into the deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually utilizes an immense quantity of water. Alternatively, aqueous foam-based fracturing fluids may offer potential advantages over conventional water-based fracturing fluid, including reduced consumption of water and environmental impact. Although foam-based fracturing has shown promising results in oil and gas industries, its applicability to EGS is unknown. Foams are complex mixtures of liquids with gaseous phases that are thermodynamically unstable. Their stability will decrease over time due to liquid drainage, bubble coarsening, and coalescence. Therefore, it is essential to stabilize foam fluids at high temperatures for EGS related applications such as fracking of HDRs.This paper is focused on investigating high-temperature stability of N2-in-water or N2 foams containing different surfactants and stabilizing agents. Foam stability was characterized by the half-life, which is defined as the time a foam decreases to 50% of its original height due to drainage. Surfactants with various concentrations dissolved in deionized water were investigated, including alfa olefin sulfonate (AOS), sodium dodecyl sulfonate (SDS), TergitolTM (NP – 40), and cetyltrimethylammonium chloride (CTAC). Also, the effects of other stabilizing agents, including guar gum, bentonite clay, crosslinker, graphene oxide (GO) dispersion on foam stability were tested. Initial results showed that foam stability decreased dramatically as temperature increased. On the other hand, foams became relatively more stable as pressure increased. Certain stabilizing agents, such as guar gum and crosslinker, can enhance foam stability at a wide range of temperatures. Our results indicate that it may be possible to obtain stable foams at high-temperature, high-pressure conditions with appropriate stabilizing agents.

Thakore, Virensinh↗

Using high pressure solutions of polyfluoroacrylate and CO 2 to Seal cement cracks for improved wellbore integrity

Polyfluoroacrylate (PFA) is a hydrophobic and oleophobic polymer that is soluble in high pressure carbon dioxide (CO 2 ). In this study, the ability of PFA-CO 2 solutions to greatly reduce the apparent permeability of split or cracked Portland cement cylindrical samples is assessed. The apparent permeability values of confined samples were determined before and after treatment with PFA-CO 2 solutions. In four tests, PFA-CO 2 solutions were continuously displacing pure CO 2 from the cracked cement and the decrease in apparent permeability due to PFA adsorption and wettability alteration was monitored. The lowest apparent permeability cracked cement sample (81 nD) was completely sealed with a very small amount of solution. Samples with initial apparent permeabilities of 89 μD and 29.4 mD exhibited 92% and 99% reductions in permeability, respectively, before the experiments had to be stopped because of the excessively large increase in pressure drop. A 50% reduction in apparent permeability was observed with a 3.80 mD sample. Four other split cement samples (bound together with tape) with an initial apparent permeability in the 9.0–70 mD range were removed from the core holder and immersed in a PFA-CO 2 solution for 24 h to allow for PFA adsorption. Then the PFA-CO 2 solution was depressurized, allowing for the deposition of additional PFA from the solution within the crack as the pressure fell below the cloud point pressure of the PFA-CO 2 solution. These four samples were then confined again in a core holder and apparent permeability reductions of 29–93% were observed. Finally, results from these eight experiments indicates that the more substantial reductions in the nD – mD apparent permeability of the cracked cement correlated to lower initial crack permeability, higher PFA concentration, and slower injection rate of the PFA-CO 2 solution into the crack.

58 GEOSCIENCES↗

Utah FORGE: Well 16B(78)-32 Drilling Data

This drilling data for Utah FORGE well 16B(78)-32 include a well survey, core summary, mud and mud temperature logs, daily reports of the drilling process, and additional data from the Pason oil and gas company. Well 16B(78)-32 serves as the production well for reservoir creation, fluid circulation, and demonstration of heat extraction for the FORGE project. It has been drilled as a doublet approximately 300 feet parallel to and above the injection well 16A(78)-32. The proposed total depth was 10,658 feet, which was exceeded. Spudding began on April 26th, 2023. As of June 20th, 2023, the total depth measured 10,947 feet and the vertical depth measured 8,357 feet. Drilling included the trial use of insulated drill pipe (IDP) from Eavor Technologies, which was considered a success. IDP restricts counter-current heat transfer between drilling fluid inside the drill string and hotter returning fluid in the annulus, thereby ensuring the bottomhole assembly (BHA) remains submerged in cool fluid. Eavor rented 350 joints of IDP to FORGE which were run in two consecutive BHAs at the well. The results of this trial are included here.

15 GEOTHERMAL ENERGY↗

Stability study of aqueous foams under high-temperature and high-pressure conditions relevant to Enhanced Geothermal Systems (EGS)

In Enhanced Geothermal System (EGS) hydraulic fracturing is carried out by injecting cold water into deep Hot Dry Rocks (HDR) under carefully controlled conditions to create new or reopen existing fractures. Water-based fracturing fluids demonstrate some challenges including immense quantity of water usage, water sensitivity of the formations, water blocking, and lack of proppant carrying capacity and transportation. Thus, an alternative is to use foam-based fracturing fluid which offers potential advantage over conventional water-based fracturing fluid such as minimum water usage, reduced wellbore damage, high proppant carrying capacity, and less environmental damage. However, foams are complex mixture of gaseous phase and liquid phase which are thermodynamically unstable at downhole conditions, and their stability can decrease over time due to liquid drainage, bubble coarsening, and coalescence. This paper shows laboratory experiments executed to study foam stability at high temperature (200°C) and high pressure (6.9MPa) conditions which simulates the geothermal environment. Foam stability was characterized by half-life of foam, which is defined as the time taken by the foam to decreases by 50% of its original height due to drainage. In this paper, two types of gaseous phases, nitrogen (N 2 ) and carbon dioxide (CO 2 ) were investigated. Also, based on successful practice of foam-based fracturing fluid in oil and gas industries, four surfactants, including Alpha olefin sulfonate (AOS), Sodium dodecyl sulfonate (SDS), Tergitol™ (NP – 40), and Cetyltrimethylammonium chloride (CTAC) at optimum concentration of 1wt.% were tested for best stability performance. In addition, different stabilizing agents including guar gum, bentonite clay, crosslinker, silicon dioxide nanoparticles (SiO 2 ), graphene oxide (GO) were also studied. Experimental results showed that N 2 foams were more stable than CO 2 foams. It was observed that foam half-life decreased with the increase in temperature. Among all the surfactants, AOS foams showed the most promising thermal stability at high temperatures. Moreover, with the addition of stabilizing agents, foam's half-life was enhanced. Stabilizing agents such as crosslinker and GO dispersion showed the most stable foams with half-life recorded at 20min and 17min, respectively, at 200°C and 6.9MPa. Finally, pressure also showed a positive effect on foam stability; with increased pressure, foam half-life was increased. Based on the experimental data, analytical models for the effect of temperature and pressure were developed, considering foam degradation is a first-order kinetic reaction that linearly depends on the foam drainage mechanism. The effect of temperature on foam half-life was studied as an exponential decay model. In this model, foam half-life is a function of drainage rate constant (D A ) and activation energy (E a ) of the foam system. The effect of pressure on foam half-life was found to obey a power-law model where an increase in pressure showed an increase in foam half-life. Furthermore, a linear relation was studied for the effect of pressure on foam activation energy and drainage rate. Then the combined effects of temperature and pressure were studied, which yielded an analytical model to predict the foam stabilities in terms of half-life for different foam compositions. In conclusion, this research indicates that with an appropriate selection of surfactants and stabilizing agents, it is possible to obtain stable foams, which could replace conventional water fracturing fluid under EGS conditions.

15 GEOTHERMAL ENERGY↗

The Impact of Naphthenic Acids on Dynamic Fluid–Fluid Interactions: Implication for Enhanced Oil Recovery

Previous coreflooding results and wettability analyses in our group show that injection of naphthenic-acid-enriched water can improve oil recovery over traditional waterflooding. This observation is still a subject of research efforts without a definitive explanation. Naphthenic acids (NA) have been reported to drive wettability alteration and increase the water–oil interface elasticity. These alterations depend on the NA carbon number and aqueous-phase salinity, among other conditions, as reported in the literature. Smart-water flooding (SWF) research often links recovery to the initial wettability condition, being higher for initially oil-wet rock. SWF refers to a technique in which the aqueous-phase ion composition or/and salinity are changed to maximize oil recovery. Given NAs’ complex solution behavior, selecting acid combinations that prompt oil recovery is a difficult objective. The aim of this research is to determine the effects of select naphthenic acids on the oil–water interfacial rheology and wettability alteration and how these interfacial effects are associated with oil recovery under spontaneous imbibition. NAs were selected based on their carbon number, molecular structure, and solubility in the saline solution used in this research. We aimed at exploring which NAs should be used to regulate interfacial properties so as to either increase oil recovery or accelerate production. Time-domain nuclear magnetic resonance, interfacial dilatational rheology, and liquid-bridge experiments, i.e., proxy of snap-off, were conducted. A baseline was established using results obtained with a previously tested sulfate-rich aqueous phase, shown to be effective in recovering oil. Results show that NA14 and N18 increase the water–oil interfacial viscoelasticity and induce interfacial healing but led to different recovery factors. N10, while effective at inducing water wetness in oil-wet rock, is ineffective at increasing the recovery factor. We concluded that wettability and oil–water interfacial rheology are not exclusive, and instead they can synergistically favor EOR benefits. Moreover, oil recovery benefits under spontaneous imbibition are shown to depend strongly on the initial wettability conditions.

Medina-Rodriguez, Bryan X. (ORCID:0000000262922831↗

Deep Learning–Assisted Multiobjective Optimization of Geological CO 2 Storage Performance under Geomechanical Risks

In geological CO 2 storage, designing the optimal well control strategy for CO 2 injection to maximize CO 2 storage while minimizing the associated geomechanical risks is not trivial. This challenge arises due to pressure buildup, CO 2 plume migration, the highly nonlinear nature of geomechanical responses to rock-fluid interaction, and the high computational cost associated with coupled flow and geomechanics simulations. In this paper, we introduce a novel optimization framework to address these challenges. The optimization problem is formulated as follows: maximize total CO 2 storage while minimizing geomechanical risks by adjusting the injection schedules within bounded constraints. The geomechanical risks are primarily driven by injection-induced pressure build-up, which is characterized by ground displacement and the induced microseismicity. We used the Fourier neural operator (FNO)-based deep learning model to construct surrogate models, replacing the time-consuming coupled flow and geomechanics simulations for evaluating the aforementioned objective functions. The developed surrogate models have been incorporated into a multiobjective optimization framework through a genetic algorithm to reduce the computational burden. The proposed optimization framework reduces the computational cost from approximately 2,400 hours, when using objective function evaluations based on physics-based simulations, to around 20 minutes. A set of Pareto-optimal solutions of the proposed workflow yields nontrivial optimal decisions, reducing the microseismicity potential and the vertical displacement. This Pareto front highlights the optimal trade-offs between CO 2 storage amount, safety, and ground displacement, emphasizing the need for careful optimization and management of injection strategies to achieve a balanced outcome. The novelty of this work is twofold. First, we demonstrate the importance of incorporating the minimization of the geomechanical risks as objective functions into the CO 2 storage optimization workflow to mitigate the potential risk of induced microseismicity and ground displacement. Second, we leverage the FNO-based surrogate models to optimize a real-field CO 2 storage operation.

42 ENGINEERING↗

Melt extruded versus extrusion compression molded glass-polypropylene long fiber thermoplastic composites

Long fiber thermoplastic (LFT) composites are processed either with extrusion compression or fiber injection processes. The properties of LFT materials are highly influenced by processing techniques, which lead to different porosity contents, fiber length distributions, and fiber orientation distributions. It is important to understand the various LFT processing techniques and their effects on mechanical, thermal, and microscopic properties. This work considered LFT sheets processed via extrusion, which offers highly aligned fibers (referred to as “Tecnogor composites”), and LFT composites produced via extrusion compression molding (ECM), which offers a random distribution of fibers. Tecnogor composites exhibited higher flexural strength (35–65%), flexural modulus (132–172%), tensile strength (39–52%), tensile modulus (67–75%), and Izod impact resistance (195–220%) than the random LFT composites. This response was attributed to the aligned fibers in Tecnogor composites. Mathematical models including Halpin-Tsai and Lavengood-Goettler were used to predict and compare the Young’s modulus of Tecnogor and ECM composites, respectively.

mechanical testing↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Robust Distributed State Estimator for Interconnected Transmission and Distribution Networks (Final Report RPPR-1)

This project’s objective is to develop a combined transmission and distribution state estimator which accounts for very large system size and model complexity (by way of distributing the computations) and large number of solar PV units connected to the distribution system on multiple feeders. The project not only provides a robust formulation and solution to this problem but also tests the solution by implementing it on a well-established large utility system. It introduces several improvements with respect to the state of the art in existing state estimation software: (a) The developed state estimator (SE) allows robust and accurate monitoring of bidirectional flows in distribution systems which result due to the distributed energy sources which are not observable and thus not incorporated in generation dispatch; (b) Large utility systems with tens of thousands of transmission buses and hundreds of thousands of distribution nodes are difficult to model as a single integrated system. This shortcoming is addressed by developing a “scalable distributed computational framework” which allows splitting the ultra large system models into several small subsystems and coordinating their solution by a robust and practical state estimation formulation; (c) Measurement errors irrespective of their locations are detected and removed by the developed state estimator. Historically, transmission and distribution systems were analyzed and operated as two independent systems. Given the non-transposed short feeder sections, unevenly loaded phases, strictly radial configuration and unidirectional power flows in the absence of remote generation, distribution system analysis was customized to account for these characteristics. However, some of these assumptions are no longer valid (non-radial configuration, bidirectional power flows) and thus distribution system analysis should be revisited. Furthermore, in the past, the interaction between the transmission and distribution systems was quite passive, where distribution substations were modeled as lumped loads in the transmission system model. With substantial generation injected by renewable generation located in the distribution systems, such modeling will no longer be accurate. The developed state estimator facilitates proper monitoring of the interactions between the transmission and distribution systems and enables smart dispatch of these units which are made observable by the state estimator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linear gyrokinetic simulations of toroidal Alfvén eigenmodes in the Mega-Amp Spherical Tokamak

Linear gyrokinetic (GK) simulations using the Gyrokinetic Toroidal Code (GTC) have been performed to investigate Toroidicity-driven Alfvén Eigenmodes (TAEs) driven by the neutral beam injection (NBI) induced fast ions in the Mega-Amp Spherical Tokamak (MAST) to identify the non-perturbative and kinetic effects of thermal plasma. A specific TAE in MAST discharge 26887, with an on-axis NBI power of approximately 1.5 MW and plasma current around 800 kA, exhibited frequency chirping, and the tangential soft x-ray camera array resolved the radial mode structure peaked near |q|=1.5. Various excitation methods were used in the GTC linear simulations, illustrating this code's capability to realistically represent the mechanisms and behaviors of fast ion-driven TAEs in spherical tokamaks. The radial structures from these GK simulations closely match measurements and calculations performed using the NOVA ideal MHD code, though with the frequencies approximately 10 kHz lower, likely due to various kinetic and non-perturbative effects. The simulations measured the damping rates due to continuum damping, radiative damping, and ion Landau damping, revealing that ion Landau damping has the most significant contribution to the total damping rate of the TAE. A comparison of growth rates of TAEs excited by fast ion Maxwellian and slowing-down distributions shows that the TAEs excited by a fast ion anisotropic pitch distribution (as part of the slowing-down distributions) are more unstable compared to those excited by a Maxwellian distribution with an equivalent fast ion beta. This shows that the use of fast ion anisotropy alters the number of fast ions to be in shear Alfvén resonance, and hence, it can greatly affect the stability of TAEs. These tests can be performed with the GTC but impossible with ideal MHD simulations, highlighting the necessity of kinetic simulations such as the GTC for a precise prediction of the TAE stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗