Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Unsupervised Azimuth Estimation of Solar Arrays in Low-Resolution Satellite Imagery through Semantic Segmentation and Hough Transform

This paper explains the use of a convolutional neural network (CNN) to segment solar panels in a satellite image containing solar arrays, and extract associated metadata from the arrays. A novel unsupervised technique is introduced to estimate the azimuth of each individual solar panel from the predicted mask of the convolutional neural network. This pipeline was developed with the aim of extracting necessary metadata for a solar installation, using only a set of latitude–longitude coordinates. Azimuth prediction results for 669 individual solar installations associated with 387 sites located across the United States are provided. A mean average error and median average error of 21.65 degrees and 1.0 degrees were obtained, respectively, when predicting the azimuth of the solar fleet data set, with about 80% of the results within an error of zero degrees of the ground truth azimuth value and about 85% within an error of 25 degrees. The predicted azimuth was then used to estimate the energy conversion of the solar arrays. Results show a 90.9 and 90.6 R-squared value for estimating alternating current (AC) and direct current (DC) energy, respectively, and a mean absolute percentage error (MAPE) of 1.70% in estimating the alternating current (AC) energy using the fully automated algorithm.

14 SOLAR ENERGY↗

Detecting brain tumor in computed tomography images using Markov random fields and fuzzy C-means clustering techniques

Brain tumors, are an abnormal growth of tissues in the brain. They may arise in people of any age. They must be detected early, diagnosed accurately, monitored carefully, and treated effectively in order to optimize patient outcomes regarding both survival and quality of life. Manual segmentation of brain tumors from CT scan images is a challenging and time consuming task. Size and location accurate detection of brain tumor plays a vital role in the successful diagnosis and treatment of tumors. Brain tumor detection is considered a challenging mission in medical image processing. The aim of this paper is to introduce a scheme for tumor detection in CT scan images using two different techniques Hidden Markov Random Fields (HMRF) and Fuzzy C-means (FCM). The proposed method has been developed in this research in order to construct hybrid method between (HMRF) and threshold. These methods have been applied on 4 different patient data sets. The result of comparison among these methods shows that the proposed method gives good results for brain tissue detection, and is more robust and effective compared with (FCM) techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep medical image analysis with representation learning and neuromorphic computing

Deep learning is increasingly used in medical imaging, improving many steps of the processing chain, from acquisition to segmentation and anomaly detection to outcome prediction. Yet significant challenges remain: (i) image-based diagnosis depends on the spatial relationships between local patterns, something convolution and pooling often do not capture adequately; (ii) data augmentation, the de facto method for learning three-dimensional pose invariance, requires exponentially many points to achieve robust improvement; (iii) labelled medical images are much less abundant than unlabelled ones, especially for heterogeneous pathological cases; and (iv) scanning technologies such as magnetic resonance imaging can be slow and costly, generally without online learning abilities to focus on regions of clinical interest. To address these challenges, novel algorithmic and hardware approaches are needed for deep learning to reach its full potential in medical imaging.

60 APPLIED LIFE SCIENCES↗

An Application of Faster R-CNNs in Object Detection Efforts Applied to the Critical Infrastructure Domain

Object detection and segmentation approaches have been successfully applied to multiple interdisciplinary domains ranging from medical imaging to autonomous vehicles. The following study details efforts to apply segmentation methods to the critical infrastructure domain. Specifically, the identification of critical sub-components of four facilities: airports, hospitals, hydroelectric dams, and water treatment plants. Data for this study was extracted from the U.S. Department of Agriculture’s National Agriculture Imagery Program data set. Each facility class was considered independently of the other facilities, producing four different segmentation models during the testing and training process. Ultimately, the study team concluded there are significant challenges associated with object detection modeling when applied to facility analysis within the critical infrastructure domain. The study team was able to identify possible sources of these challenges that could be potentially addressed in future work.

97 MATHEMATICS AND COMPUTING↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm

Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymph nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% {+-} 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methods for rapid identification of anomalous layers in laser powder bed fusion

In situ process monitoring is a key requirement for increased industry acceptance of powder bed Additive Manufacturing. As sensing technologies increase in maturity, attention must also be given to effective data exploration techniques. These data are often high-resolution and multi-modal, with each build consisting of thousands of layers. Here, in this paper, the authors propose two methods enabling users to rapidly identify layers of interest within a build. Both methods leverage results from deep learning based segmentations of in situ powder bed images. The first method is an unsupervised “reverse layer search” algorithm while the second method uses supervised machine learning.

36 MATERIALS SCIENCE↗

Wettability Effects on Primary Drainage Mechanisms and NAPL Distribution: A Pore-Scale Study

The pore-scale processes governing water drainage behavior in porous media have implications for geoscience multiphase scenarios including carbon capture and storage, contaminant site remediation, oil recovery, and vadose zone processes. However, few studies report directly observed pore-scale water drainage phenomena in 3-D soils. This knowledge gap limits our ability to verify assumptions underlying existing models and develop optimal solutions. As such, this paper utilizes synchrotron X-ray microtomography to present an experimental pore-scale examination of nonaqueous phase liquid (NAPL)/water distribution along a primary drainage front as dense NAPL was injected upward into water wetting (WW) and intermediate wetting (IW) sand-packed columns. Pore-network structures were extracted from imaged data sets and mapped onto segmented NAPL/water data sets which allowed quantitative examinations of wettability impacts on (a) the extent to which NAPL fills individual pore bodies and (b) relationships between pore size and the phase occupying the pore, with both considered as a function of distance (and capillary pressure) relative to the NAPL front. These results revealed that several hypotheses treating IW sand similarly to WW sands are simplistic. IW systems exhibited a sequence of pore filling that deviated from traditional capillary pressure-based model predictions: NAPL invades smaller pores, while larger, adjacent pores are bypassed leaving multipore residual water ganglia. NAPL pore saturations were close to 1 and did not change with capillary pressure in IW systems. Overall, the results illustrate how a relatively small change in operative contact angle alters NAPL distribution during water drainage, with important implications for geoscience multiphase flow scenarios.

58 GEOSCIENCES↗

Search for very-short-baseline oscillations of reactor antineutrinos with the SoLid detector

In this paper we report the first scientific result based on antineutrinos emitted from the BR2 reactor at SCK CEN. The SoLid experiment uses a novel type of highly granular detector whose basic detection unit combines two scintillators, polyvinyl toluene (PVT) and Li 6 F : ZnS ( Ag ) , to measure antineutrinos via their inverse- β -decay products. An advantage of PVT is its highly linear response as a function of deposited particle energy. The full-scale detector comprises 12 800 voxels and operates over a very short 6.3–8.9 m baseline from the reactor core. The detector segmentation and its three-dimensional imaging capabilities facilitate the extraction of the positron energy from the rest of the visible energy, allowing the latter to be utilized for signal-background discrimination. We present a result obtained from 280 reactor-on days (55 MW mean power) and 172 reactor-off days, respectively, of live data taking. A total of 29 479 ± 603 (stat) antineutrino candidates have been selected, corresponding to an average rate of 105 events per day and a signal-to-background ratio of 0.27. A search for disappearance of antineutrinos to a sterile state has been conducted using complementary model-dependent frequentist and Bayesian fits, providing constraints on the allowed region of the reactor antineutrino anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-scale vehicle tracking in low spatial-resolution and low frame-rate overhead video

Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery either in real-time or quickly on-demand is very desirable. With this ability we can begin to answer a number of interesting questions such as, what are normal traffic patterns in a particular region or where did that truck come from? There are many challenges associated with processing this type of data, some of which we will address in the paper. Wide-field image sequences are very large with many thousands of pixels on a side and are characterized by lower resolutions (e.g. worse than 0.5 meters/pixel) and lower frame rates (e.g. a few Hz or less). The objects in the scenery can vary in size, density, and contrast with respect to the background. At the same time the background scenery provides a number of clutter sources both man-made and natural. We describe our current implementation of an ultrascale capable multiple-vehicle tracking algorithm for overhead persistent surveillance imagery as well as discuss the tracking and timing performance of the currently implemented algorithm which is aimed at utilizing grayscale electrooptical image sequences alone for the track segment generation.

42 ENGINEERING↗

Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors

Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems are less susceptible to metal artifacts and provide better CT number linearity than conventional CT scanners. However, their contrast is limited by the properties of the megavoltage photons and the low detective quantum efficiency (DQE) of flat panel detector systems currently available. By using higher DQE, thick, segmented cadmium tungstate detectors, the authors can improve the low contrast detectability of a MVCT system. This in turn would permit greater soft tissue visualization for a given radiation dose, allowing MVCT to be used in more clinical situations. Methods: This article describes the evaluation of our prototype system that uses thick, segmented detectors. In order to create images using a dose that would be acceptable for day to day patient imaging, the authors evaluated their system using the low intensity bremsstrahlung component of a 6 MeV electron beam. The system was evaluated for its uniformity, high contrast resolution, low contrast detectability, signal to noise ratio, contrast to noise ratio, and CT number linearity. Results: The prototype system was found to have a high contrast spatial resolution of about 5 line pairs per cm, and to be able to visualize a 15 mm 1.5% contrast target with 2 cGy of radiation dose delivered. SNR{sup 2} vs radiation dose and mean pixel value vs electron density curves were linear. Conclusions: This prototype system shows a large improvement in low contrast detectability over current MVCBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction of Dislocation Potential Relief by Means of Self-Blocking Effect

The effect of dislocation self-blocking in intermetallic compounds with an anomalous temperature dependence of yield stress has been theoretically and experimentally analyzed. In essence, this effect is a dislocation self-immersion in a deep potential relief valley (without external stress). The possibility of reconstructing the relief shape (from one-valley to two-valley) is shown and the relief parameters are reported. The allowed and forbidden regions for self-blocking are revealed. The method for determining the ratio of the valley depths by measuring the self-blocking limiting angles between the dislocation segments is proposed. Transmission electron microscopy images of the dislocation structure can be used to this end. As an example, this ratio is estimated for a superpartial dislocation sliding in the cube plane in Ni{sub 3}Ge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

3D Imaging of Nickel Oxidation States using Full Field X-ray Absorption Near Edge Structure Nanotomography

Reduction-oxidation (redox) cycling of the nickel electrocatalyst phase in the solid oxide fuel cell (SOFC) anode can lead to performance degradation and cell failure. A greater understanding of nickel redox mechanisms at the microstructural level is vital to future SOFC development. Transmission x-ray microscopy (TXM) provides several key techniques for exploring oxidation states within SOFC electrode microstructure. Specifically, x-ray nanotomography and x-ray absorption near edge structure (XANES) spectroscopy have been applied to study samples of varying nickel (Ni) and nickel oxide (NiO) compositions. The imaged samples are treated as mock SOFC anodes containing distinct regions of the materials in question. XANES spectra presented for the individual materials provide a basis for the further processing and analysis of mixed samples. Images of composite samples obtained are segmented, and the distinct nickel and nickel oxide phases are uniquely identified using full field XANES spectroscopy. Applications to SOFC analysis are discussed.

30 DIRECT ENERGY CONVERSION↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-based model of the spectrin cytoskeleton for red blood cell simulation

We simulate deformable red blood cells in the microcirculation using the immersed boundary method with a cytoskeletal model that incorporates structural details revealed by tomographic images. The elasticity of red blood cells is known to be supplied by both their lipid bilayer membranes, which resist bending and local changes in area, and their cytoskeletons, which resist in-plane shear. The cytoskeleton consists of spectrin tetramers that are tethered to the lipid bilayer by ankyrin and by actin-based junctional complexes. We model the cytoskeleton as a random geometric graph, with nodes corresponding to junctional complexes and with edges corresponding to spectrin tetramers such that the edge lengths are given by the end-to-end distances between nodes. The statistical properties of this graph are based on distributions gathered from three-dimensional tomographic images of the cytoskeleton by a segmentation algorithm. We show that the elastic response of our model cytoskeleton, in which the spectrin polymers are treated as entropic springs, is in good agreement with the experimentally measured shear modulus. By simulating red blood cells in flow with the immersed boundary method, we compare this discrete cytoskeletal model to an existing continuum model and predict the extent to which dynamic spectrin network connectivity can protect against failure in the case of a red cell subjected to an applied strain. As a result, the methods presented here could form the basis of disease- and patient-specific computational studies of hereditary diseases affecting the red cell cytoskeleton.

59 BASIC BIOLOGICAL SCIENCES↗

Methodology for Yield Determination of Surface Shots Over Water

Shockwave analysis is one of the few methods used to determine the yield of a nuclear detonation. It has been noted that the shockwave of these surface shots over water are asymmetric making accurate yield determination difficult. To calculate the yield of these shots more accurately, reanalysis of these films is required. Armed with the digitized replicas of the original nuclear test films and the latest image processing tools, a methodology for segmenting the shockwave from the digitized film and measuring these shockwaves is devised to quickly and accurately quantify the shape of these asymmetric shockwaves. With a two-dimensional result from these asymmetric shockwaves, several methods are discussed to transform the final shockwave contour to a scalar value which can be used in existing yield determination equations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Addressing Issues with Working Memory in Video Object Segmentation

Contemporary state-of-the-art video object segmentation (VOS) models compare incoming unannotated images to a history of image-mask relations via affinity or cross-attention to predict object masks. We refer to the internal memory state of the initial image-mask pair and past image-masks as a working memory buffer. While the current state of the art models perform very well on clean video data, their reliance on a working memory of previous frames leaves room for error. Affinity-based algorithms include the inductive bias that there is temporal continuity between consecutive frames. To account for inconsistent camera views of the desired object, working memory models need an algorithmic modification that regulates the memory updates and avoid writing irrelevant frames into working memory. A simple algorithmic change is proposed that can be applied to any existing working memory-based VOS model to improve performance on inconsistent views, such as sudden camera cuts, frame interjections, and extreme context changes. The resulting model performances show significant improvement on video data with these frame interjections over the same model without the algorithmic addition. Our contribution is a simple decision function that determines whether working memory should be updated based on the detection of sudden, extreme changes and the assumption that the object is no longer in frame. By implementing algorithmic changes, such as this, we can increase the real-world applicability of current VOS models.

97 MATHEMATICS AND COMPUTING↗

Investigation of Three-Dimensional Microstructure of Tricalcium Silicate (C 3 S) by Electron Microscopy

A serial block-face scanning electron microscopy (SBFSEM) system, composed of a scanning electron microscope (SEM) and an ultra-microtome installed within the SEM vacuum chamber, has been used to characterize the three-dimensional (3D) microstructure of tricalcium silicate (C 3 S) grains embedded in epoxy resin. A selection of C 3 S grains were segmented and rendered with 3D-image processing software, which allowed the C 3 S grains to be clearly visualized and enabled statistically quantitative analysis. The results show that about 5% of the C 3 S grains have volumes larger than 1 μm 3 and the average volume of the grains is 25 μm 3 . Pores can also be clearly seen in the biggest C 3 S grain, the volume of which is 3.6 × 10 4 μm 3 , and the mean volume and total volume of all the pores within this grain are 4.8 μm 3 and 3.0 × 10 3 μm 3 , respectively. This work provides a new approach for the characterization of the 3D spatial structure of raw C 3 S materials, and the resulting 3D structure of the raw C 3 S is important for further systematic research on the relationships between the spatial microstructure and the hydration kinetics of C 3 S and other cement minerals.

36 MATERIALS SCIENCE↗