Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION CURRENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Formation of multi-charged ion beams by focusing effect of mid-electrode on electron cyclotron resonance ion source

We are constructing a tandem type electron cyclotron resonance ion source (ECRIS) and a beam line for extracting ion beams. The ion beam is extracted from the second stage by an accel-decel extraction system with a single-hole and the ion beam current on each electrode is measured. The total ion beam current is measured by a faraday cup downstream the extraction electrodes. We measure these currents as a function of the mid-electrode potential. We also change the gap length between electrodes and perform similar measurement. The behaviors of these currents obtained experimentally against the mid-electrode potential show qualitatively good agreement with a simple theoretical consideration including sheath potential effects. The effect of mid-electrode potential is very useful for decreasing the beam loss for enhancing ion beam current extracted from ECRIS.

43 PARTICLE ACCELERATORS↗

The future of heavy ion radiotherapy

Currently, there is an increasing interest in heavy ion radiotherapy (RT) and a number of new facilities are being installed in Europe and Japan. This development is accompanied by intensive technical, physical, and clinical research. The authors identify six research fields where progress is likely and propose a thesis on the expected achievements for each of the fields: (1) Synchrotrons with active energy variation and three-dimensional beam scanning will be the standard in ion beam RT. (2) Common standards for precise measurement, prescription, and reporting of dose will be available. (3) Intensity-modulated particle therapy will be state-of-the-art. (4) Time-adaptive treatments of moving targets will be feasible. (5) Therapeutic effectiveness of heavy ions will be known for the most important indications while cost effectiveness will remain to be shown. (6) The potential of high-linear energy transfer radiation will be known. The rationale for each of these theses is described.

60 APPLIED LIFE SCIENCES↗

Self-Consistent Model of Magnetospheric Electric Field, Ring Current, Plasmasphere, and Electromagnetic Ion Cyclotron Waves: Initial Results

Further development of our self-consistent model of interacting ring current (RC) ions and electromagnetic ion cyclotron (EMIC) waves is presented. This model incorporates large scale magnetosphere-ionosphere coupling and treats self-consistently not only EMIC waves and RC ions, but also the magnetospheric electric field, RC, and plasmasphere. Initial simulations indicate that the region beyond geostationary orbit should be included in the simulation of the magnetosphere-ionosphere coupling. Additionally, a self-consistent description, based on first principles, of the ionospheric conductance is required. These initial simulations further show that in order to model the EMIC wave distribution and wave spectral properties accurately, the plasmasphere should also be simulated self-consistently, since its fine structure requires as much care as that of the RC. Finally, an effect of the finite time needed to reestablish a new potential pattern throughout the ionosphere and to communicate between the ionosphere and the equatorial magnetosphere cannot be ignored.

Gamayunov, K. V.↗

Compact electron beam ion sources/traps: Review and prospects (invited)

The Dresden electron beam ion trap (EBIT)/electron beam ion source (EBIS) family are very compact and economically working table-top ion sources. We report on the development of three generations of such ion sources, the so-called Dresden EBIT, Dresden EBIS, and Dresden EBIS-A, respectively. The ion sources are classified by different currents of extractable ions at different charge states and by the x-ray spectra emitted by the ions inside the electron beam. We present examples of x-ray measurements and measured ion currents extracted from the ion sources at certain individual operating conditions. Ion charge states of up to Xe{sup 48+} but also bare nuclei of lighter elements up to nickel have been extracted. The application potential of the ion sources is demonstrated via proof-of-concept applications employing an EBIT in a focused ion beam (FIB) column or using an EBIT for the production of nanostructures by single ion hits. Additionally we give first information about the next generation of the Dresden EBIS series. The so-called Dresden EBIS-SC is a compact and cryogen-free superconducting high-B-field EBIS for high-current operation.

43 PARTICLE ACCELERATORS↗

Long pulse production of high current D{sup -} ion beams in the JT-60 negative ion source

The first long pulse production of high power D{sup -} ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D{sup -} ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D{sup -} ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D{sup -} ion beams of 12.5 and 9.8 A were produced at 340 keV with cesium seeding at a rate of {approx}14 {mu}g/s into the ion sources. The pulse duration of these D{sup -} ion beams was extended step by step, and then was successfully extended up to 18 s without degradation of the negative ion production. The D{sup -} ion beams were neutralized to yield 3.6 MW D{sup 0} beams by a gas cell, and then injected into the JT-60 U plasma. Further, a slight reduction of D{sup -} ion beam power allowed the longer injection duration of 21 s at a D{sup 0} beam power of 3.2 MW. The success in the long pulse production of a high power D{sup -} ion beam shows that negative ion beams can be produced during a few tens of seconds without degradations of negative ion production and the voltage holding in a large Cs-seeded negative ion source.

43 PARTICLE ACCELERATORS↗

Current technology in ion and electrothermal propulsion

The state of the art and projected developmental trends in the fields of ion and electrothermal propulsion systems intended for use in long and complex earth-orbital missions and interplanetary spacecraft missions are reviewed. The characteristics of existing thrust vectoring systems are outlined, together with data on the 5-cm and 8-cm electron bombardment thrusters, the cesium bombardment ion thruster, and the 8-cm, 15-cm, and 30-cm thruster using xenon propellant. The electrothermal ammonia system and the electrothermal hydrazine system are described, and the principles of propulsion system selection are examined.

Finke, R. C.↗

Ion beam sputter etching and deposition of fluoropolymers

Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanism and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.

Banks, B. A.↗

Ion beam sputter etching and deposition of fluoropolymers

Fluoropolymer etching and deposition techniques including thermal evaporation, RF sputtering, plasma polymerization, and ion beam sputtering are reviewed. Etching and deposition mechanisms and material characteristics are discussed. Ion beam sputter etch rates for polytetrafluoroethylene (PTFE) were determined as a function of ion energy, current density and ion beam power density. Peel strengths were measured for epoxy bonds to various ion beam sputtered fluoropolymers. Coefficients of static and dynamic friction were measured for fluoropolymers deposited from ion bombarded PTFE.

Banks, B. A.↗

Error mitigation, optimization, and extrapolation on a trapped-ion testbed

Current noisy intermediate-scale quantum (NISQ) trapped-ion devices are subject to errors which can significantly impact the accuracy of calculations if left unchecked. A form of error mitigation called zero noise extrapolation (ZNE) can decrease an algorithm’s sensitivity to these errors without increasing the number of required qubits. Here we explore different methods for integrating this error mitigation technique into the Variational Quantum Eigensolver (VQE) algorithm for calculating the ground state of the HeH + molecule at 0.8 Å in the presence of experimental noise. Using the Quantum Scientific Computing Open User Testbed (QSCOUT) trapped-ion device, we test three methods of scaling noise for extrapolation: time stretching the two-qubit gates, scaling the sideband detuning parameter, and inserting two-qubit gate identity operations into the ansatz circuit. We find that time stretching and sideband detuning scaling fail to scale the noise on our particular hardware in a way that can be extrapolated to zero noise. Scaling our noise with global gate identity insertions and extrapolating after variational optimization, we achieve error suppression of 96.8%, resulting in an energy estimate within –0.004 ± 0.04 hartree of the ground state energy. This is an improvement, but still outside the chemical accuracy threshold of 0.0016 hartree. Furthermore, our results show that the efficacy of this error mitigation technique depends on choosing the correct implementation for a given device architecture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗