Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Impact of Gastric Filling on Radiation Dose Delivered to Gastroesophageal Junction Tumors

Purpose: This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Materials and Methods: Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. Results: FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >=50.4 Gy (V{sub 50.4Gy}) was 100% in all situations. The planning GTV V{sub 63Gy} became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Conclusions: Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integration of the Cardiovascular Risk Model Astro-CHARM in the NASA Radiation Risk Model

Space radiation poses an increased risk for cardiovascular diseases (CVD) during and after spaceflight, that should be quantified to plan future space missions such as the flight to Mars. The radiation-induced CVD risk is evaluated using a linear no-threshold dose response excess relative risk (ERR) model, so that the risk is function of the radiation dose and of the background (i.e., non-exposed) incidence rate. The background CVD risk can be evaluated using clinical prediction models (CPMs). The first CPMs developed in the 1960’s have identified CVD risk factors such as blood pressure, diabetes, cholesterol, and smoking. In this work, the steps used to integrate the CVD risk provided by a CPM into the NASA Radiation Risk Model are described. Simulation results calculated using available data for relevant mission scenarios are also shown, and the challenges in CVD risk predictions are discussed.

Space radiation↗

Controlled Dispensing and Mixing of Pico- to Nanoliter Volumes Using On-Demand Droplet-Based Microfluidics

We present an integrated droplet-on-demand microfluidic platform for dispensing, mixing, incubating, extracting and analyzing by mass spectrometry pico- to nanoliter sized droplets. Droplet generation is accomplished using computer-controlled pneumatic valves. Controlled actuation of valves for different aqueous streams enables controlled dosing and rapid mixing of reagents within droplets in the droplet generation area or in a region with widening channel cross-section. Following incubation, which takes place while droplets travel in the oil stream, the droplet contents are extracted to an aqueous channel for subsequent ionization at an integrated nanoelectrospray emitter. As an initial demonstration of the platform, rapid enzymatic digestions of a model protein are performed in droplets and detected on-line by nanoelectrospray ionization mass spectrometry.

Environmental Molecular Sciences Laboratory↗

Simulation of proton-induced energy deposition in integrated circuits

A time-efficient simulation technique was developed for modeling the energy deposition by incident protons in modern integrated circuits. To avoid the excessive computer time required by many proton-effects simulators, a stochastic method was chosen to model the various physical effects responsible for energy deposition by incident protons. Using probability density functions to describe the nuclear reactions responsible for most proton-induced memory upsets, the simulator determines the probability of a proton hit depositing the energy necessary for circuit destabilization. This factor is combined with various circuit parameters to determine the expected error-rate in a given proton environment. An analysis of transient or dose-rate effects is also performed. A comparison to experimental energy-disposition data proves the simulator to be quite accurate for predicting the expected number of events in certain integrated circuits.

Fernald, Kenneth W.↗

Integration of a Radiosensitivity Molecular Signature Into the Assessment of Local Recurrence Risk in Breast Cancer

Purpose: Recently, we developed radiosensitivity (RSI), a clinically validated molecular signature that estimates tumor radiosensitivity. In the present study, we tested whether integrating RSI with the molecular subtype refines the classification of local recurrence (LR) risk in breast cancer. Methods and Materials: RSI and molecular subtype were evaluated in 343 patients treated with breast-conserving therapy that included whole-breast radiation therapy with or without a tumor bed boost (dose range 45-72 Gy). The follow-up period for patients without recurrence was 10 years. The clinical endpoint was LR-free survival. Results: Although RSI did not uniformly predict for LR across the entire cohort, combining RSI and the molecular subtype identified a subpopulation with an increased risk of LR: triple negative (TN) and radioresistant (reference TN-radioresistant, hazard ratio [HR] 0.37, 95% confidence interval [CI] 0.15-0.92, P=.02). TN patients who were RSI-sensitive/intermediate had LR rates similar to those of luminal (LUM) patients (HR 0.86, 95% CI 0.47-1.57, P=.63). On multivariate analysis, combined RSI and molecular subtype (P=.004) and age (P=.001) were the most significant predictors of LR. In contrast, integrating RSI into the LUM subtype did not identify additional risk groups. We hypothesized that radiation dose escalation was affecting radioresistance in the LUM subtype and serving as a confounder. An increased radiation dose decreased LR only in the luminal-resistant (LUM-R) subset (HR 0.23, 95% CI 0.05-0.98, P=.03). On multivariate analysis, the radiation dose was an independent variable only in the LUMA/B-RR subset (HR 0.025, 95% CI 0.001-0.946, P=.046), along with age (P=.008), T stage (P=.004), and chemotherapy (P=.008). Conclusions: The combined molecular subtype–RSI identified a novel molecular subpopulation (TN and radioresistant) with an increased risk of LR after breast-conserving therapy. We propose that the combination of RSI and molecular subtype could be useful in guiding radiation therapy–based decisions in breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Atomic Energy Agency (IAEA) Coordinated Research Projects on Structural Integrity of Reactor Pressure Vessels

The International Atomic Energy Agency (IAEA) has conducted a series of Coordinated Research Projects (CRPs) that have focused on irradiated reactor pressure vessel (RPV) steel fracture toughness properties and approaches for assuring structural integrity of RPVs throughout operating life. A series of nine CRPs have been sponsored by the IAEA, starting in the early 1970s, focused on neutron radiation effects on RPV steels. The purpose of the CRPs was to develop comparisons and correlations to test the uniformity of irradiated results through coordinated international research studies and data sharing. Consideration of dose rate effects, effects of alloying (nickel, manganese, silicon, etc.) and residual elements (eg., copper and phosphorus), and drop in upper shelf toughness are also important for assessing neutron embrittlement effects. The ultimate use of embrittlement understanding is assuring structural integrity of the RPV under current and future operation and accident conditions. Material fracture toughness is the key ingredient needed for this assessment, and many of the CRPs have focused on measurement and application of irradiated fracture toughness. This paper presents an overview of the progress made since the inception of the CRPs in the early 1970s. The chronology and importance of each CRP have been reviewed and put into context for continued and long-term safe operation of RPVs.

36 MATERIALS SCIENCE↗

SU-E-T-22: A Deterministic Solver of the Boltzmann-Fokker-Planck Equation for Dose Calculation

Purpose: The Boltzmann-Fokker-Planck equation (BFPE) accurately models the migration of photons/charged particles in tissues. While the Monte Carlo (MC) method is popular for solving BFPE in a statistical manner, we aim to develop a deterministic BFPE solver based on various state-of-art numerical acceleration techniques for rapid and accurate dose calculation. Methods: Our BFPE solver is based on the structured grid that is maximally parallelizable, with the discretization in energy, angle and space, and its cross section coefficients are derived or directly imported from the Geant4 database. The physical processes that are taken into account are Compton scattering, photoelectric effect, pair production for photons, and elastic scattering, ionization and bremsstrahlung for charged particles.While the spatial discretization is based on the diamond scheme, the angular discretization synergizes finite element method (FEM) and spherical harmonics (SH). Thus, SH is used to globally expand the scattering kernel and FFM is used to locally discretize the angular sphere. As a Result, this hybrid method (FEM-SH) is both accurate in dealing with forward-peaking scattering via FEM, and efficient for multi-energy-group computation via SH. In addition, FEM-SH enables the analytical integration in energy variable of delta scattering kernel for elastic scattering with reduced truncation error from the numerical integration based on the classic SH-based multi-energy-group method. Results: The accuracy of the proposed BFPE solver was benchmarked against Geant4 for photon dose calculation. In particular, FEM-SH had improved accuracy compared to FEM, while both were within 2% of the results obtained with Geant4. Conclusion: A deterministic solver of the Boltzmann-Fokker-Planck equation is developed for dose calculation, and benchmarked against Geant4. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

Integrated Modeling and Monitoring Technologies for Environmental Resiliency in Nuclear Energy

Environmental concerns pose the biggest challenge for the development of the nuclear energy industry, often preventing or limiting the construction of new plants and radioactive waste disposal facilities. There are currently numerous sites in the world at which surface and groundwater are contaminated by nuclear weapon production and testing, as well as due to nuclear power plant accidents. Many of those sites remain unused or inhabited primarily due to public concern. Improving scientific and technical capabilities to develop environmental resiliency is critical not only to address existing contamination, but also to build public confidence and support for nuclear energy. One of the obstacles in remediation is to tackle a large volume of contaminated soil and groundwater with relatively low concentrations. Although many contaminant removal technologies have developed (e.g., pump-and-treat systems), they are often expensive and not cost-effective for low-concentration radionuclide contamination. Although soil removal is often the most effective, it produces a large amount of waste that has to be stored securely for a long period of time or treated at the special treatment facilities. Transporting a large amount of waste may also produce greenhouse gases and disrupt local communities. Recently, the concept of 'sustainable remediation' has been proposed to improve a remediation system as a whole, including the consideration of cost effectiveness, reduction of greenhouse emission, waste production and energy usage. Rather than just focusing on removing contaminants, the sustainable remediation highlights the use of passive remediation technologies to immobilize radionuclides along with the application of monitored natural attenuation and longer institutional control. However, such passive technologies and monitored natural attenuation require the increased burden of proof to ensure that those immobilized contaminants would not compromise the long-term public health. Although contaminant transport modeling and risk assessments are always performed, they sometimes fail due to the lack of understanding the contaminant transport proposes at the time of the risk assessment or due to some unexpected processes. Monitoring technologies are critical to ensure the long-term stability of such remediated sites, and also to address the public concerns. Recent advances in in situ sensor technologies and spatially-extensive mapping technologies (such as unmanned aerial vehicles, airborne mapping, geophysics) have improved monitoring of contamination over space and time. In addition to new sensing devices, data management and data analytics technologies have been expanded to manage and process large spatial and temporal datasets. Such technologies can be used to reduce monitoring cost significantly, and to facilitate long-term monitoring. In this study, we demonstrate our data analytics technologies for two nuclear-related contaminated sites: (1) air dose rate monitoring in Fukushima prefecture, and (2) groundwater monitoring at the Savannah River Site F-Area. We are developing the spatial and temporal data integration methodologies to integrate various spatially extensive data and time-series data for improving long-term monitoring. Such monitoring technologies and experiences at the existing contaminated sites can be transferred to build a better monitoring system for nuclear facilities, such as nuclear power plants or nuclear waste storages.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Channel Implant Variation on Radiation-Induced Edge Leakage Currents in n-Channel MOSFETs

The effects of radiation-induced defects and statistical variation in the dose and energy of MOSFET channel implants in a modern bulk CMOS technology are modeled using a process simulator in combination with analytical computations. The model integrates doping profiles obtained from process simulations and experimentally determined defect potentials into implicit surface potential equations. Solutions to these equations are then used to model radiation-induced edge leakage currents in 90-nm bulk CMOS n-channel MOSFETs. The results indicate that slight variations in the channel implant parameters can have a significant impact on the doping profile along the shallow trench isolation sidewall and thus the radiation-induced edge leakage currents.

42 ENGINEERING↗

Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms

The current standard for brachytherapy dose calculations is based on the AAPM TG-43 formalism. Simplifications used in the TG-43 formalism have been challenged by many publications over the past decade. With the continuous increase in computing power, approaches based on fundamental physics processes or physics models such as the linear-Boltzmann transport equation are now applicable in a clinical setting. Thus, model-based dose calculation algorithms (MBDCAs) have been introduced to address TG-43 limitations for brachytherapy. The MBDCA approach results in a paradigm shift, which will require a concerted effort to integrate them properly into the radiation therapy community. MBDCA will improve treatment planning relative to the implementation of the traditional TG-43 formalism by accounting for individualized, patient-specific radiation scatter conditions, and the radiological effect of material heterogeneities differing from water. A snapshot of the current status of MBDCA and AAPM Task Group reports related to the subject of QA recommendations for brachytherapy treatment planning is presented. Some simplified Monte Carlo simulation results are also presented to delineate the effects MBDCA are called to account for and facilitate the discussion on suggestions for (i) new QA standards to augment current societal recommendations, (ii) consideration of dose specification such as dose to medium in medium, collisional kerma to medium in medium, or collisional kerma to water in medium, and (iii) infrastructure needed to uniformly introduce these new algorithms. Suggestions in this Vision 20/20 article may serve as a basis for developing future standards to be recommended by professional societies such as the AAPM, ESTRO, and ABS toward providing consistent clinical implementation throughout the brachytherapy community and rigorous quality management of MBDCA-based treatment planning systems.

60 APPLIED LIFE SCIENCES↗

In vitro functional screening as a means to identify new plasticizers devoid of reproductive toxicity

Plasticizers are indispensable additives providing flexibility and malleability to plastics. Among them, several phthalates, including di (2-ethylhexyl) phthalate (DEHP), have emerged as endocrine disruptors, leading to their restriction in consumer products and creating a need for new, safer plasticizers. The goal of this project was to use in vitro functional screening tools to select novel non-toxic plasticizers suitable for further in vivo evaluation. A panel of novel compounds with satisfactory plasticizer properties and biodegradability were tested, along with several commercial plasticizers, such as diisononyl-cyclohexane-1,2-dicarboxylate (DINCH®). MEHP, the monoester metabolite of DEHP was also included as reference compound. Because phthalates target mainly testicular function, including androgen production and spermatogenesis, we used the mouse MA-10 Leydig and C18-4 spermatogonial cell lines as surrogates to examine cell survival, proliferation, steroidogenesis and mitochondrial integrity. The most promising compounds were further assessed on organ cultures of rat fetal and neonatal testes, corresponding to sensitive developmental windows. Dose-response studies revealed the toxicity of most maleates and fumarates, while identifying several dibenzoate and succinate plasticizers as innocuous on Leydig and germ cells. Interestingly, DINCH®, a plasticizer marketed as a safe alternative to phthalates, exerted a biphasic effect on steroid production in MA-10 and fetal Leydig cells. MEHP was the only plasticizer inducing the formation of multinucleated germ cells (MNG) in organ culture. Overall, organ cultures corroborated the cell line data, identifying one dibenzoate and one succinate as the most promising candidates. The adoption of such collaborative approaches for developing new chemicals should help prevent the development of compounds potentially harmful to human health. - Highlights: • Phthalate plasticizers exert toxic effects on male reproduction. • Reproductive toxicity of new plasticizers was assessed by functional assays. • Mouse Leydig and germ cell lines, and rat perinatal testis cultures were used. • Survival, proliferation, steroidogenesis, abnormal germ cell formation were examined. • Reproductive toxic and innocuous plasticizer candidates were identified.

54 ENVIRONMENTAL SCIENCES↗

First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target Tracking

Purpose: For intrafraction motion management, a real-time tracking system was developed by combining fiducial marker-based tracking via simultaneous kilovoltage (kV) and megavoltage (MV) imaging and a dynamic multileaf collimator (DMLC) beam-tracking system. Methods and Materials: The integrated tracking system employed a Varian Trilogy system equipped with kV/MV imaging systems and a Millennium 120-leaf MLC. A gold marker in elliptical motion (2-cm superior-inferior, 1-cm left-right, 10 cycles/min) was simultaneously imaged by the kV and MV imagers at 6.7 Hz and segmented in real time. With these two-dimensional projections, the tracking software triangulated the three-dimensional marker position and repositioned the MLC leaves to follow the motion. Phantom studies were performed to evaluate time delay from image acquisition to MLC adjustment, tracking error, and dosimetric impact of target motion with and without tracking. Results: The time delay of the integrated tracking system was {approx}450 ms. The tracking error using a prediction algorithm was 0.9 {+-} 0.5 mm for the elliptical motion. The dose distribution with tracking showed better target coverage and less dose to surrounding region over no tracking. The failure rate of the gamma test (3%/3-mm criteria) was 22.5% without tracking but was reduced to 0.2% with tracking. Conclusion: For the first time, a complete tracking system combining kV/MV image-guided target tracking and DMLC beam tracking was demonstrated. The average geometric error was less than 1 mm, and the dosimetric error was negligible. This system is a promising method for intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved spectral data unfolding for radiochromic film imaging spectroscopy of laser-accelerated proton beams

An improved method to unfold the space-resolved proton energy distribution function of laser-accelerated proton beams using a layered, radiochromic film (RCF) detector stack has been developed. The method takes into account the reduced RCF response near the Bragg peak due to a high linear energy transfer (LET). This LET dependence of the active RCF layer has been measured, and published data have been re-interpreted to find a nonlinear saturation scaling of the RCF response with stopping power. Accounting for the LET effect increased the integrated particle yield by 25% after data unfolding. An iterative, analytical, space-resolved deconvolution of the RCF response functions from the measured dose was developed that does not rely on fitting. After the particle number unfold, three-dimensional interpolation is performed to determine the spatial proton beam distribution for proton energies in-between the RCF data points. Here, image morphing has been implemented as a novel interpolation method that takes into account the energy-dependent, changing beam topology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of silver metallization and electron irradiation on the mechanical deformation of polyimide films

The impact of silver metallization and electron irradiation on the physical and mechanical properties of polyimide films has been studied. The metal that impregnated the structure of the polyimide substrate was 1–5 μm. The surface coatings contained 80–97% of the relative silver mirror in the visible and infrared regions. Irradiation was performed at the ELU-6 linear accelerator with an average beam electron energy of 2 MeV, an integral current of up to 1000 μA, a pulse repetition rate of 200 Hz, and a pulse duration of 5 μs. The absorbed dose in the samples was 10, 20, 30, and 40 MGy. The samples were deformed at room temperature under uniaxial tension on an Instron 5982 universal testing system. The structural changes in the composite materials that result from the impact of the physical factors were studied using an X-ray diffractometer DRON-2M in air at 293 K using CuK{sub α} radiation (λ{sub αCu} = 1.5418 Å). A substantial growth of mechanical characteristics resulting from the film metallization, as compared to the pure film, was observed. The growth of the ultimate strength by Δσ = 105 MPa and the plasticity by Δε = 75% is connected with the characteristics of the change of structure of the metallized films and the chemical etching conditions. The electron irradiation of the metallized polyimide film worsens its elastic and strength characteristics due to the formation of new phases in the form of silver oxide in the coating. The concentration of these phases increased with increasing dose, which was also the result of the violation of the ordered material structure, namely, the rupture of polyimide macromolecule bonds and the formation of new phases of silver in the coating. A mathematical model was obtained that predicts the elastic properties of silver metallized polyimide films. This model agrees with the experimental data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Meeting Report--NASA Radiation Biomarker Workshop

A summary is provided of presentations and discussions from the NASA Radiation Biomarker Workshop held September 27-28, 2007, at NASA Ames Research Center in Mountain View, California. Invited speakers were distinguished scientists representing key sectors of the radiation research community. Speakers addressed recent developments in the biomarker and biotechnology fields that may provide new opportunities for health-related assessment of radiation-exposed individuals, including for long-duration space travel. Topics discussed include the space radiation environment, biomarkers of radiation sensitivity and individual susceptibility, molecular signatures of low-dose responses, multivariate analysis of gene expression, biomarkers in biodefense, biomarkers in radiation oncology, biomarkers and triage following large-scale radiological incidents, integrated and multiple biomarker approaches, advances in whole-genome tiling arrays, advances in mass-spectrometry proteomics, radiation biodosimetry for estimation of cancer risk in a rat skin model, and confounding factors. Summary conclusions are provided at the end of the report.

59 BASIC BIOLOGICAL SCIENCES↗

Climatic and Chemical Controls on Methane Emissions from Wetlands

Natural wetlands are the largest single source of methane to the atmosphere and the only one dominated by climate. Although interannual variations in methane emissions from short-term climate variations are becoming better understood, major uncertainties remain with respect to the sensitivity of wetlands and their CH4 emissions to climate variability, the sensitivity of suppression of wetland methane missions to changes in low-dose sulfate deposition, and the response of wetland dynamics to climate variations. We present results from modeling, field, and remote sensing research that integrate current understanding of the dynamics of wetlands and their methane emissions.

Matthews, Elaine↗

Innovative Solutions for Loading Smaller Standardized Dry Storage Canister Systems for Used Nuclear Fuel - 16232

An integrated team lead by EnergySolutions has developed and evaluated design concepts and loading processes for standardized transportation, aging and disposal (STAD) canister systems for the dry storage of United States (US) commercial used nuclear fuel (UNF). These STADs would be smaller than the Dual Purpose Canisters (DPCs) currently in use for storage and transportation of UNF at the nuclear power plant (NPP) sites in the US, so it was necessary to study the operational requirements and impacts related to their implementation at the NPPs and develop innovative approaches to mitigate these impacts. This work was funded by the US Department of Energy (DOE) to support the DOE in evaluating the option of using standardized canister systems for storage, transport, and disposal of US commercial UNF as part of an integrated waste management system. The NPP utilities are currently placing UNF into increasingly large DPCs because this reduces loading times and associated worker dose uptake. However, whether large DPCs may be able to be directly disposed is not known at this time, and will depend in part on future geologic disposal concepts and the DPC heat content. The use of STAD canisters rather than DPCs at the NPP sites and/or at an interim storage facility could avoid a potential need to repackage the UNF for disposal but, to make STAD canisters attractive for use, ways need to be found to fill and seal them efficiently from an operational perspective. This paper describes the generic design for a small STAD canister system, the loading processes and process improvements that were identified for the small, medium and large STAD canister sizes, the methodology for, and results from, the assessment of the performance of the loading processes, and the practicality of the results versus NPP operating experience. The work that this paper reports thus reflects research and development efforts to explore technical concepts that could support future decision-making by DOE. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synergistically combining peracetic acid and reduced graphene oxide membranes to degrade trace organic contaminants

The removal of trace organic contaminants is a critical step for the reuse of municipal and industrial wastewater. Herein, we demonstrate a catalytic membrane platform synergistically integrating reduced graphene oxide (rGO) membranes and peracetic acid (PAA) oxidation, using a dye of methylene blue (MB) and a pesticide of 2,4-dichlorophenoxyacetic acid (2,4-D) as model contaminants. In a crossflow system with rGO membrane and 25 ppm PAA, the degradation rates of MB and 2,4-D were 22 and 0.12 g h −1 per g rGO, with an initial concentration of 10 and 1.1 ppm, respectively. The degradation time profile of MB and 2,4-D follows a pseudo-first-order model, and the degradation rate constant increases with increasing initial PAA doses. Here, the rGO membranes also exhibited good stability over a 1-month test for 2,4-D degradation. In addition to the nanofiltration performance of the rGO membrane, the integrated PAA-rGO membrane process shows great potential to degrade various organic contaminants without the need to separate and recover the metal-free catalyst in downstream treatment.

2,4-D↗