Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDUCTANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Diagnostic studies of ion beam formation in inductively coupled plasma

This dissertation describes a variety of studies focused on the plasma and the ion beam in inductively coupled plasma mass spectrometry (ICP-MS). The ability to use ICP-MS for measurements of trace elements in samples requires the analytes to be efficiently ionized. Updated ionization efficiency tables are discussed for ionization temperatures of 6500 K and 7000 K with an electron density of 1 x 10 15 cm -3 . These values are reflective of the current operating parameters of ICP-MS instruments. Calculations are also discussed for doubly charged (M 2+ ) ion formation, neutral metal oxide (MO) ionization, and metal oxide (MO + ) ion dissociation for similar plasma temperature values. Ionization efficiency results for neutral MO molecules in the ICP have not been reported previously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trace metal analysis by laser ablation-inductively coupled plasmamass spectrometry and x-ray K-edge densitometry of forensic samples

This dissertation describes a variety of studies on the determination of trace elements in samples with forensic importance. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) was used to determine the trace element composition of numerous lipstick samples. Lipstick samples were determined to be homogeneous. Most lipstick samples of similar colors were readily distinguishable at a 95% confidence interval based on trace element composition. Numerous strands of a multi-strand speaker cable were analyzed by LA-ICP-MS. The strands in this study are spatially heterogeneous in trace element composition. In actual forensic applications, the possibility of spatial heterogeneity must be considered, especially in cases where only small samples (e.g., copper wire fragments after an explosion) are available. The effects of many unpredictable variables, such as weather, temperature, and human activity, on the retention of gunshot residue (GSR) around projectile wounds were assessed with LAICP- MS. Skin samples around gunshot and stab wounds and larvae feeding in and around the wounds on decomposing pig carcasses were analyzed for elements consistent with GSR (Sb, Pb, Ba, and Cu). These elements were detected at higher levels in skin and larvae samples around the gunshot wounds compared to the stab wounds for an extended period of time throughout decomposition in both a winter and summer study. After decomposition, radiographic images of the pig bones containing possible damage from bullets revealed metallic particles embedded within a number of bones. Metallic particles within the bones were analyzed with x-ray, K-edge densitometry and determined to contain lead, indicating that bullet residue can be retained throughout decomposition and detected within bones containing projectile trauma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Additive Manufacturing Consolidation of Low-Cost Water Atomized Steel Powder Using Micro-Induction Sintering

ORNL worked with Grid Logic Inc to demonstrate micro induction sintering (MIS) and binder decomposition of steel powders. It was shown that MIS effectively emits spatially confined electromagnetic energy that is directly coupled to metallic powders resulting in resistive heating of individual particles. The non-uniformity of particle morphology and distribution of the water atomized steel powders resulted in inefficient transfer of energy. It was shown that adhering the particles together using polymer binders resulted in more efficient coupling. Using the MIS processes, debinding and sintering could be done in a single step. When combined with another system, such as binder-jet, this could reduce the amount of required post-processing. An invention disclosure was filed on hybrid systems that use MIS to reduce the amount of required post-processing.

36 MATERIALS SCIENCE↗

Beam Breakup in a Solid-State Powered Linear Induction Accelerator

Scorpius is a new multi-pulse linear induction accelerator (LIA) for flash radiography of large-scale, explosively-driven hydrodynamic experiments. It has been proposed to use solid-state pulsed-power modules to provide the accelerating voltages for Scorpius. It is expected that this approach can provide four programmable 50-kV accelerating pulses to a single gap.

43 PARTICLE ACCELERATORS↗

Optimum tunes for the DARHT and Scorpius linear induction accelerators

A systematic approach to design of optimum magnetic focusing tunes for linear induction accelerators (LIA) is described. The magnetic fields used for focusing and beam transport must be strong enough to suppress beam breakup, yet not so strong that they induce envelope instability. Balancing these objectives, while also minimizing magnet power requirements, results in the optimum tune.

43 PARTICLE ACCELERATORS↗

Induction Heating for Tritium Storage Beds (FY19 PDRD Project Summary Report)

Metal hydride beds used for storing hydrogen isotopes at the Savannah River Site are conductively heated and cooled to desorb and absorb gases during storage cycling. While several storage bed configurations have been utilized over the years, many achieve heating by utilizing electric cartridge heaters positioned laterally along the longest axis of the storage bed (FACE Gen 2 Beds). Others achieve heating and cooling through hot and cold nitrogen flow (Gen 1 Beds). While these beds/heating configurations are well-designed for storage cycling operations, it is unclear if they can be regenerated to operating conditions once too much helium has accumulated in them. Full regeneration of hydride beds occurs around 625 - 650 °C. It is unclear if the currently employed electric cartridge heaters in Gen 2 beds can reach these temperatures. Furthermore, since swelling can occur during routine heating operations, it is unclear if existing cartridge heaters in Gen 2 beds can be swapped for higher-power cartridges that can reach 625 - 650 °C . Similarly, nitrogen air flow (to the best of our knowledge) cannot cause Gen 1 beds to reach these temperatures. Thus, existing Gen 1 and Gen 2 beds need to be heated through an alternative method to removal helium, so the beds can either return to normal operation or be disposed of. The goal of this PDRD was to investigate if induction heating can be used for various heating processes involving hydride storage beds (e.g. regeneration, gas cycling, helium heel removal). In the original call for proposals, this PDRD fell under "Gas Processing" area of interest # 3: "Develop methods to deploy alternate ways to heat existing process equipment to minimize impact to glove box environment."

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concurrent evaluation of autophagy induction and Burkholderia infection at the single cell level

Autophagy is a natural, regulated cellular process that "cleans up" cellular debris by degrading and recycling dysfunctional proteins. There is a high potential impact of exploiting the benefits of autophagy to complement existing treatments, but little has been done to date on bacterial pathogens of defense concern such as Burkholderia pseudomallei, a highly virulent Select Agent pathogen that is intrinsically resistant to most classes of antibiotics. Assessment of autophagy in the context of infection typically requires use of multiple technologies in combination (e.g., Western analysis paired with microscopy or flow cytometry) as applied to heterogeneous populations of cells. To address this, we have developed a dual target reporter cell line (RAW264.7 LC3-BFP:mPlum, GFP-RelA) that enables concurrent visualization of infection and autophagy induction. We assessed the effect of clinically approved small molecule inducers of autophagy on infection by Burkholderia thailendensis, a closely related but less virulent surrogate for B. pseudomallei. The reporter cells were first infected with a B. thailendensis strain that constitutively expresses GFP, then treated with one of four known autophagy inducers (rapamycin, niclosamide, bromhexine HC1, or flubendazole) for 4 hours. Confocal fluorescence imaging was used to quantify autophagy stimulation at the single cell level. Autophagy maturation was observed as a decrease in BFP LC3 puncta with a concurrent increase in mPlum LC3 puncta. B. thailendensis infection was assessed by monitoring translocation of GFP-RelA (an NFkB subunit) into the nucleus and through quantitating the intracellular bacterial presence in single cells. Preliminary results indicate that bromhexine HC1 and niclosamide may hinder B. thailendensis' ability to replicate intracellularly and reduce overall bacterial survival.

59 BASIC BIOLOGICAL SCIENCES↗

Initial conditions for simulations of beam physics in linear induction accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the DualAxis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Magnetic Induction Sensors for Detecting Anomalous Shielding of Radiological and Nuclear Materials: A Feasibility Study

This study examined a concept for improving the nation's ability to detect unauthorized transport of radiological and nuclear material that involves detecting not the radiological or nuclear material itself, but rather the anomalous presence of materials, such as lead and tungsten, typically used to shield such illicit materials from detection. Specifically, the project studied a potentially inexpensive, non-intrusive, and fast method of detecting anomalous shielding: use of magnetic induction sensors to measure currents induced in conductors by a driver coil. The first phase of this work, documented in this report, identified the signatures of materials of interest, assessed the usefulness of measured signatures for discrimination between materials, and then benchmarked models and calculations. The next task involved assessing the strength of these signatures when the materials of interest were enclosed within other materials, such as aluminum and steel, of various thicknesses. A final task mimicked a real-world scenario by testing the ability to detect material signatures of interest at a scale of a vehicle or cargo vessel against a cluttered backdrop, with and without the shielding of another material, such as aluminum or steel. This final task raised doubts regarding whether this detection scheme will be useful under real-world conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Elemental Analysis of Bio-Oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). Laboratory Analytical Procedure (LAP), Issue Date: May 13, 2022

Concentrations of inorganic elements is a key quality metric for bio-oils as certain elements impact upgrading processes and product quality. Unless reduced or removed during production and processing, alkali and alkaline metals native to lignocellulosic biomass can carry over into bio-oils contributing to ash content and degraded catalyst performance during upgrading to hydrocarbon fuels or chemical products. Non-metallic elements such as sulfur and phosphorus can also negatively impact upgrading catalysts and product quality. Inductively coupled plasma optical emission spectroscopy (ICP-OES) can be used to measure inorganic elements of interest in bio-oils. This procedure covers the preparation and analysis of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) bio-oils. The concentrations of these elements can indicate potential bio-oil quality from the perspective of deoxygenation processes. The implications of elemental composition will depend on process parameters such as upgrading catalyst sensitivities. This Laboratory Analytical Procedure (LAP) covers two methods for quantification of inorganic elements by ICP-OES: Procedure A uses microwave assisted digestion with concentrated nitric acid, and Procedure B is an organic ICP-OES method utilizing a diglyme solvent.

09 BIOMASS FUELS↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

An Induction-Type Septum Magnet for the Hadron and Electron Injection of the EIC Complex

The design of the electron Ion Collider (EIC) project is under way to be built at the Brookhaven National Laboratory (BNL) with the collaboration of the Thomas Jefferson National Accelerator Facility (TJNAF). The Rapid Cycling Synchrotron (RCS) which is part of the EIC accelerator complex will accelerate the electron beam up to 18 GeV, and the beam will be injected into the Electron Storage Ring (ESR) to collide with the hadron beam circulating in the Hadron Storage Ring (HSR) which is a modified version of the Relativistic Heavy Ion Collider (RHIC). All three synchrotrons will be located in the same tunnel. This technical note provides information on the latest electromagnetic design of the induction-type septum magnet which will be employed by EIC to Inject the beam into the HSR and RCS and also extract the beam from the RCS.

43 PARTICLE ACCELERATORS↗

APPLICATION OF INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY IN THE ANALYSIS OF PLUTONIUM CONTENT OF FAST CRITICAL ASSEMBLY FUEL DISPOSITION

Outline • Fast Critical Assembly (FCA) Plutonium Fuel Disposition • Brief campaign overview • Savannah River National Laboratory • Analytical capabilities and instrumentation • Typical FCA sample analysis process • Plutonium analysis by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS) • Method description/development • Instrumentation • Data/control charts

Bonilla, Henry J. [Savannah River National Laborat↗

HPC for optimizing process parameters to control material evolution in seamless induction hardening of wind turbine main shaft bearings

Work proposed in this project focused on understanding the effect of martensitic transformation in the steel on the potential for cracking during seamless induction hardening (SIH) as a function of process conditions to allow the process to optimally scale up. Large-scale, three-dimensional phase-field simulations of martensitic transformation were performed using MEUMAPPS-SS (Microstructure Evolution Using Massively Parallel Phase-field Simulations – Solid State) code developed at Oak Ridge National Laboratory. The simulations were guided by location-specific thermal history generated by experimental measurements of time-temperature history generated at The Timken Company. The simulations were able to capture the morphological evolution of the martensite variants in an Fe-1.0C-1.5Cr steel based on the Nishiyama-Wasserman (NW) orientation relationship. The simulations were also able to quantify the stress-state at the interface between impinging martensite variants. The simulations indicated that the magnitude of the various stress and strain components were dependent on the sizes of the impinging plates with a reduction in these quantities with reduced plate size in agreement with experimental findings. The results obtained from the simulations will be used to guide the optimization of the alloy thermal conditions to eliminate quench cracking during SIH of bearing steels.

17 WIND ENERGY↗