Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

ART-Ada design project, phase 2

Interest in deploying expert systems in Ada has increased. An Ada based expert system tool is described called ART-Ada, which was built to support research into the language and methodological issues of expert systems in Ada. ART-Ada allows applications of an existing expert system tool called ART-IM (Automated Reasoning Tool for Information Management) to be deployed in various Ada environments. ART-IM, a C-based expert system tool, is used to generate Ada source code which is compiled and linked with an Ada based inference engine to produce an Ada executable image. ART-Ada is being used to implement several expert systems for NASA's Space Station Freedom Program and the U.S. Air Force.

Lee, S. Daniel↗

Hydrazine monitoring in spacecraft

Hydrazine (HZ) and monomethyl hydrazine (MMH) are highly toxic compounds used as fuels in the Space Shuttle Orbiter Main Engines and in its maneuvering and reaction control system. Satellite refueling during a mission may also result in release of hydrazines. During extravehicular activities, the potential exists for hydrazines to contaminate the suit and to be brought into the internal atmosphere inadvertantly. Because of the high toxicity of hydrazines, a very sensitive, reliable, interference-free, and real-time method of measurement is required. A portable ion mobility spectrometer (IMS) has exhibited a low ppb detection limit for hydrazines suggesting a promising technology for the detection of hydrazines in spacecraft air. The Hydrazine Monitor is a modified airborne vapor monitor (AVM) with a custom-built datalogger. This off-the-shelf IMS was developed for the detection of chemical warfare agents on the battlefield. After early evaluations of the AVM for hydrazine measurements showed a serious interference from ammonia, the AVM was modified to measure HZ and MMH in the ppb concentration range without interference from ammonia in the low ppm range. A description of the Hydrazine Monitor and how it functions is presented.

Cross, J. H.↗

Simulations of microphysical, radiative, and dynamical processes in a continental-scale forest fire smoke plume

The impact of a large forest fire smoke plume on atmospheric processes is studied through a numerical model of meteorology, aerosols, and radiative transfer. The simulated smoke optical depths at 0.63-micron wavelength are in agreement with analyses of satellite data and show values as high as 1.8. The smoke has an albedo of 35 percent, or more than double the clear-sky value, and cools the surface by as much as 5 K. An imaginary refractive index, n sub im, of 0.01 yields results which closely match the observed cooling, single scattering albedo, and the Angstrom wavelength exponent. An n exp im of 0.1, typical of smoke from urban fires, produces 9 K cooling. Coagulation causes the geometric mean radius by number to increase from the initial value of 0.08 micron to a final value of 0.15 micron, while the specific extinction and absorption increase by 40 and 25 percent, respectively.

Westphal, Douglas L.↗

Development of a sensitive monitor for hydrazine

The development of hand-held, ambient-temperature instruments that utilize ion mobility spectrometry (IMS) in the detection of hydrazine and monomethylhydrazine is reviewed. A development effort to eliminate ammonia interference through altering the ionization chemistry, based on adding 5-nonanone as dopant in the ionization region of the IMS, is presented. Calibration of this instrument conducted before and after STS-37 revealed no more than a 5 percent difference between calibration curves, without any appreciable loss of equipment function.

Eiceman, Gary A.↗

Information management challenges of the EOS Data and Information System

An overview of the current information management concepts that are embodied in the plans for the Earth Observing System Data and Information System (EOSDIS) is presented, and some of the technology development and application areas that are envisioned to be particularly challenging are introduced. The Information Management System (IMS) is the EOSDIS element that provides the primary interface between the science users and the data products and services of EOSDIS. The goals of IMS are to define a clear and complete set of functional requirements and to apply innovative methods and technologies to satisfy them. The information management functions are described in detail, and some applicable technolgies are discussed. Some of the general issues affecting the successful development and operation of the information management element are addressed.

Mcdonald, Kenneth R.↗

Fiber/matrix adhesion in graphite/PEKK composites

Experiments with poly ether ketone ketone (PEKK) resin and AS-4, IM-7, and G30-500 fibers showed excellent correlation between resin/fiber contact angle and composite transverse flexural strength as measures of resin/fiber interfacial strength. Both tests indicate the strongest interface for G30-500/PEKK followed by IM-7/PEKK and AS-4/PEKK. Also discussed are fiber effects on interlaminar fracture and on the in situ crystallization of the matrix during composite fabrication.

Bucher, R. A.↗

A study of ion composition and dynamics at Comet Halley

This report details the participation by Lockheed co-investigators in the reduction, analysis, and interpretation of data obtained by the Ion Mass Spectrometer onboard the Giotto mission to Comet Halley. The data analysis activities and much of the scientific collaboration was shared by this team. One objective of the effort under this contract was to use data obtained by the Giotto Ion Mass Spectrometer (IMS) during the encounter with comet Halley for the purpose of advancing our understanding of the chemistry and physics of the interaction of the solar wind with comets and obtaining new information on the comet's composition. An additional objective was to make this unique data set available in a format which can be easily used by the reset of the cometary science community for other analysis in the future. The IMS has two sensors: the High Intensity Spectrometer (HIS) and the High Energy Range Spectrometer (HERS).

Shelley, E. G.↗

Measured and predicted effects of gravity level on directional dendritic solidification of NH4Cl-H2O

Dendritic growth front rates during vertical directional solidification are predicted for gravity levels of 10 exp 0 g sub e (where e is earth gravity), 10 exp -1 g sub e, 10 exp -2 g sub e, 10 exp -3 g sub e, 10 exp -4 g sub e, and 10 exp -5 g sub e (microgravity) for the physical conditions used for a recent ammonium chloride-water solidification experiment on the International Microgravity Laboratory I (IMLI). The growth front rates at 10 exp 0 g sub e and 10 exp -5 g sub e are validated using ground based laboratory and IMLI experimental data. As the gravity decreases, the growth rates increase until they approach a maximum at approximately 10 exp -4 g sub e. The 10 exp -4 and 10 exp -5 levels are equivalent. Liquid concentration and volume fraction, temperature profiles and fluid flow velocities are also calculated. Kinetic energy calculations for each of the six gravity levels indicate that the threshold for fluid flow to affect the growth front rate is in the range of 10 exp -8 ergs.

Mccay, T. D.↗

ART/Ada and CLIPS/Ada

Although they have reached a point of commercial viability, expert systems were originally developed in artificial intelligence (AI) research environments. Many of the available tools still work best in such environments. These environments typically utilize special hardware such as LISP machines and relatively unfamiliar languages such as LISP or Prolog. Space Station applications will require deep integration of expert system technology with applications developed in conventional languages, specifically Ada. The ability to apply automation to Space Station functions could be greatly enhanced by widespread availability of state-of-the-art expert system tools based on Ada. Although there have been some efforts to examine the use of Ada for AI applications, there are few, if any, existing products which provide state-of-the-art AI capabilities in an Ada tool. The goal of the ART/Ada Design Project is to conduct research into the implementation in Ada of state-of-the-art hybrid expert systems building tools (ESBT's). This project takes the following approach: using the existing design of the ART-IM ESBT as a starting point, analyze the impact of the Ada language and Ada development methodologies on that design; redesign the system in Ada; and analyze its performance. The research project will attempt to achieve a comprehensive understanding of the potential for embedding expert systems in Ada systems for eventual application in future Space Station Freedom projects. During Phase 1 of the project, initial requirements analysis, design, and implementation of the kernel subset of ART-IM functionality was completed. During Phase 2, the effort has been focused on the implementation and performance analysis of several versions with increasing functionality. Since production quality ART/Ada tools will not be available for a considerable time, and additional subtask of this project will be the completion of an Ada version of the CLIPS expert system shell developed by NASA. This tool will provide full syntactic compatibility with any eventual products of the ART/Ada design while allowing SSFP developers early access to this technology.

Culbert, Chris↗

A data and information system for processing, archival, and distribution of data for global change research

Work on this project was focused on information management techniques for Marshall Space Flight Center's EOSDIS Version 0 Distributed Active Archive Center (DAAC). The centerpiece of this effort has been participation in EOSDIS catalog interoperability research, the result of which is a distributed Information Management System (IMS) allowing the user to query the inventories of all the DAAC's from a single user interface. UAH has provided the MSFC DAAC database server for the distributed IMS, and has contributed to definition and development of the browse image display capabilities in the system's user interface. Another important area of research has been in generating value-based metadata through data mining. In addition, information management applications for local inventory and archive management, and for tracking data orders were provided.

Graves, Sara J.↗

The pinhole interface for IMS/MS

An important supplementary technique for ion mobility spectrometry (IMS) is mass spectrometry (MS). A mass spectrometer coupled to an ion mobility spectrometer (IMS/MS) can provide significant information on the composition of the ions contributing to an ion mobility peak. On the other hand, the interpretation of IMS/MS results requires knowledge of processes which can occur at the pinhole interface. When the ion composition is a mixture of ion clusters, the observed cluster distribution may not be an accurate representation of the ion clusters in the IMS. Depending on the buffer gas, lower clusters can form by equilibrating with reduced concentrations in the continuum regime of the expansion and larger clusters can form by collisional stabilization in the cooled jet stream. Besides water, nitrogen molecules can also add to the ion clusters. Even though nitrogen is non-polar, this addition is made possible by an ion-induced dipole interaction between the ion and molecule.

Spangler, Glenn E.↗

The luminosity function for different morphological types in the CfA Redshift Survey

We derive the luminosity function for different morphological types in the original CfA Redshift Survey (CfA1) and in the first two slices of the CfA Redshift Survey Extension (CfA2). CfA1 is a complete sample containing 2397 galaxies distributed over 2.7 steradians with m(sub z) less than or equal 14.5. The first two complete slices of CfA2 contain 1862 galaxies distributed over 0.42 steradians with m(sub z)=15.5. The shapes of the E-S0 and spiral luminosity functions (LF) are indistinguishable. We do not confirm the steeply decreasing faint end in the E-S0 luminosity function found by Loveday et al. for an independent sample in the southern hemisphere. We demonstrate that incomplete classification in deep redshift surveys can lead to underestimates of the faint end of the elliptical luminosity function and could be partially responsible for the difference between the CfA survey and other local field surveys. The faint end of the LF for the Magellanic spirals and irregulars is very steep. The Sm-Im luminosity function is well fit by a Schechter function with M*=-18.79, alpha=-1.87, and phi*=0.6x10(exp -3) for M(sub z) less than or equal to -13. These galaxies are largely responsible for the excess at the faint end of the general CfA luminosity function. The abundance of intrinsically faint, blue galaxies nearby affects the interpretation of deep number counts. The dwarf population increases the expected counts at B=25 in a no-evolution, q(sub 0)=0.05 model by a factor of two over standard no-evolution estimates. These dwarfs change the expected median redshift in deep redshift surveys by less than 10 percent . Thus the steep Sm-Im LF may contribute to the reconciliation of deep number counts with deep redshift surveys.

Marzke, Ronald O.↗

A multiwavelength campaign of active stars with intermediate rotation rates

Near-to-simultaneous ultraviolet and visual spectroscopy of two moderate nu(sin i) RS CVn systems, V815 Herculis (nu(sin i) = 27 km s(exp -1)) and LM Pegasi (nu(sin i) = 24 km s(exp -1)), are presented along with contemporaneous UBV (RI)(sub c) - band photometry. These data were used to probe inhomogeneities in the chromospheres and photospheres, and the possible relationship between them. Both systems show evidence for rotationally modulated chromospheric emission, generally varying in antiphase to the photospheric brightness. A weak flare was observed at Mg II for V815 Her. In the case of IM Peg, we use photometry and spectra to estimate temperatures, sizes, and locations of photospheric spots. Further constraints on the spot temperature is provided by TiO observations. For IM Peg, the anticorrelation between chromospheric emission and brightness is discussed in the context of a possible solar-like spot cycle.

Dempsey, Robert C.↗

The Effects of Promethazine on Human Performance, Mood States, and Motion Sickness Tolerance

Intramuscular (IM) injections of promethazine in 25 mg or 50 mg dosages are commonly used to treat space motion sickness in astronauts. The present study examined the effects of IM injections of promethazine on neuropsy-chological performance, mood states, and motion sickness tolerance in humans. Twelve men, mean age 36 plus or minus 3.1 participated in one training (no injections) and three treatment conditions: a 25 mg injection of promethazine, a 50 mg injection of promethazine, and a placebo injection of sterile saline. Each condition, spaced at 7 day intervals, required an 8-10 hr session in which subjects were given four repetitions of 12 performance tasks, and one rotating chair motion sickness test. On the training day subjects were trained on each task to establish stability and proficiency. On treatment days, the order in which the drug or placebo was assigned to subjects was counter-balanced and a double-blind technique was used. Statistically significant decrements in performance were observed on 10 of 12 tasks when subjects were given 25 mg or 50 mg of promethazine as compared to the placebo. Performance decrements were associated with mean blood alcohol dose equivalency levels of 0.085% for 25 mg and 0. 1 37% for 50 mg dosages. The mood scale results showed significant changes in individual subjective experiences with maximum deterioration in the arousal state and fatigue level. When compared to placebo significant increases in motion sickness tolerance were found for both dosages of promethazine. These data suggest that effective dosages of promethazine currently used to counteract motion sickness in astronauts may significantly impair task components of their operational performance.

Cowings, Patricia S.↗

Cyclic Adenosine Monophosphate Accumulation and beta-Adrenergic Binding in Unweighted and Denervated Rat Soleus Muscle

Unweighting, but not denervation, of muscle reportedly "spares" insulin receptors, increasing insulin sensitivity. Unweighting also increases beta-adrenergic responses of carbohydrate metabolism. These differential characteristics were studied further by comparing cyclic adenosine monophosphate (cAMP) accumulation and beta-adrenergic binding in normal and 3-day unweighted or denervated soleus muscle. Submaximal amounts of isoproterenol, a p-agonist, increased cAMP accumulation in vitro and in vivo (by intramuscular (IM) injection) to a greater degree (P less than .05) in unweighted muscles. Forskolin or maximal isoproterenol had similar in vitro effects in all muscles, suggesting increased beta-adrenergic sensitivity following unweighting. Increased sensitivity was confirmed by a greater receptor density (B(sub max)) for iodo-125(-)-pindolol in particulate preparations of unweighted (420 x 10(exp -18) mol/mg muscle) than of control or denervated muscles (285 x 10(exp-18) mol/mg muscle). The three dissociation constant (Kd) values were similar (20.3 to 25.8 pmol/L). Total binding capacity (11.4 fmol/muscle) did not change during 3 days of unweighting, but diminished by 30% with denervation. This result illustrates the "sparing" and loss of receptors, respectively, in these two atrophy models. In diabetic animals, IM injection of insulin diminished CAMP accumulation in the presence of theophylline in unweighted muscle (-66% +/- 2%) more than in controls (-42% +'- 6%, P less than .001). These results show that insulin affects CAMP formation in muscle, and support a greater in vivo insulin response following unweighting atrophy. These various data support a role for lysosomal proteolysis in denervation, but not in unweighting, atrophy.

Kirby, Christopher R.↗

Measurement of Atomic Oxygen in Diffuse Aurora and Ion Density in the E-Region

An ion mass spectrometer (IMS) was refurbished, calibrated and supplied to the University of Colorado payload (Dr. Charles Barth, P.I.) which was launched from White Sands in September of 1993 as NASA 33.062. The nose cone failed to deploy and their were problems with the ACS so the mission was declared a failure. However, the door covering the IMS deployed and the instrument obtained data. The launch occurred shortly after a payload carrying solar x-ray detectors was launched. Thus a small portion of the Colorado payload science was salvaged; namely, the NO(+)/O2(+) ratio to compare with the measured x-ray flux. Figure I shows the NO(+) to O2(+) ratio vs. altitude. The behavior is typical of the E-region.

Sharp, William E.↗

A Helium GC/IMS for the Analysis of Extraterrestrial Volatiles in Exobiology Flight Experiments

For exobiology experiments on board spacecraft or space probes, a wide range of chemical species often must be detected and identified. The limited amount of power and space available for flight instruments severely limits the number of instruments that can be flown on any given mission. It is important then, that these experiments utilize instrumentation with universal response, so that all species of interest can be analyzed. Instrumentation to fulfill the analytical requirements of exobiology experiments has been developed utilizing Gas Chromatography - Ion Mobility Spectrometry. The Gas Chromatograph (GC) combines columns developed specifically for the complex mixtures anticipated with highly sensitive Metastable Ionization Detectors (a type of Helium Ionization Detector). To satisfy the limitations placed on resources, the Ion Mobility Spectrometer (IMS) uses the same ultra high purity helium as the GC. This GC-MS provides the analytical capability to fulfill a wide range of exobiology flight experiment applications and has been included on a proposed Discovery Mission and proposals for both Lander and Orbiter of the European Space Agency's Rosetta Comet Mission. A data base of helium IMS spectra is now being built for these future applications.

Kojiro, Daniel R.↗

Analysis of Ultra-Pure Gases by Ion Mobility Spectrometry

Work has continued with the evaluation of the Ion Mobility Spectrometer (IMS) for the analysis of gases having low parts-per-billion (10(exp -9)) water concentration. A modified PCP, inc. MMS-160 Mobility Mass Spectrometer System was used for the analysis of ultra-pure argon and nitrogen. The MMS-160 system permits the mass-identification of unique reactant and product ions observed in the reduced-water host gases. When the water is removed to low ppb levels, higher energy reactant ions are observed. In nitrogen, distinct odd- and even-numbered nitrogen cluster ion mobility peaks are observed, as well as adduct ion peaks from the trace contaminants in the gas. Argon also produces a cluster ion mobility peak and adduct ion peaks from trace components in the gas. Levels of contaminants in these ultra-pure gases can be determined from the ion mobility spectra. A calibrated source was used to provide variable known quantities of water to the pure gas supply of the IMS.

Stimac, Robert M.↗