Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Case Study: Hybridizing Nuclear Energy Systems in the U.S.

This case study was presented at the ICTP-IAEA VIRTUAL Course on Nuclear-Renewable Integrated Energy Systems: Phenomenology, Research and Development. It provides preliminary results on an analysis of hybridizing the two nuclear power plants owned by Xcel Energy and located in Minnesota. The analysis extends previous analyses that provided only price-taker results. Those assume adjusting the generation sold to the grid does not impact locational marginal electricity prices nor do they estimate impacts on the total net cost to serve the load. This presentation summarizes the new technique that was developed to both optimize the size and operations of the hybridized system and the resulting impacts on the grid when it is operated optimally.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER operation. The gas profile and the magnetic field distribution for each scenario has been considered in these evaluations. The worst case power loads and power densities for each surface have been used to study their thermo-mechanical behaviour and manufacturing feasibility. The details of these calculations and results obtained are presented and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WECC Variable Generation Planning Reference Book: Appendices

The document titled “WECC Variable Generation Planning Reference Book”. This book is divided into two volumes; one is the main document (volume 1)and the other is appendices (volume 2). The main document is a collection of the best practices and the information regarding the application and impact of variables generation on power system planning. This volume (appendices) has additional information on the following topics: Probabilistic load flow problems. 2. Additional useful indices. 3. high-impact low-frequency (HILF) events. 4. Examples of wide-area nomograms. 5. Transmission line ratings, types of dynamic rating methods. 6. Relative costs per MW-km of different electric power transmission technologies. 7. Ultra-high voltage (UHV) transmission. 8.High voltage direct current (VSC-HVDC). 9. HVDC. 10. Rewiring of existing transmission lines. 11. High-temperature low sag (HTLS) conductors. 12. The direct method and energy functions for transient stability analysis in power systems. 13.Blackouts caused by voltage instability. 14. Algorithm for parameter continuation predictor-corrector methods. 15. Approximation techniques available for security regions. 16. Impacts of wind power on power system small signals stability. 17. FIDVR. 18. FACTS. 19. European planning standard and practices. 20. International experience in wind and solar energy sources. 21. Western Renewable Energy Zones (WREZ). 22. various energy storage technologies. 23. demand response. 24. BA consolidation and cooperation options. 25. generator power management requirements and 26. European planning guidelines.

Makarov, Yuri V.↗

Estuarine nutrient pollution impact reduction assessment through euphotic zone avoidance/bypass considerations

The feasibility of reducing nutrient pollution impact by redirecting the effluent to depths below the euphotic zone was investigated for the deep estuarine Puget Sound region of the Salish Sea in the Pacific Northwest of America. The hypothesis tested was that the thickness of the outflow layer in deep estuaries may be greater than the euphotic zone depth, allowing a fraction of nutrients to be exported out passively through the layers immediately below. The euphotic zone depth in Puget Sound varies from 8 to 25 m while the depth of the outflow layer can reach up to ≈ 60 m. Outfall relocation strategies were tested on 99% of the anthropogenic nutrient loads currently delivered to Puget Sound. The impact was quantified using the previously established biophysical Salish Sea Model, using gross primary production and exposure to low dissolved oxygen (DO) levels as the metric (< 2 mg/L for hypoxia and < 5 mg/L for impairment). Eliminating nutrient pollution (above natural) from rivers and wastewater reduced hypoxia exposure by 8.1% and 11.2%, respectively. Relocating the outfalls to deeper waters resulted in improvements, but only in the sill-less sub-basins such as Whidbey, where hypoxia and DO impairment exposure decreased (7.9% and 6.8%, respectively). The presence of multiple sills and circulation cells in Puget Sound resulted in increased exposure and rendered nutrient bypass goals unfeasible as originally envisioned. However, an alternate nutrient export pathway was identified through bottom exchange flow out of Puget Sound via Whidbey Basin and Deception Pass. An unexpected reduction in the exchange outflow magnitude (≈ 4%) due additional (22%) freshwater discharged to the estuary bottom was also noted. The potential loss in circulation strength due to rerouting of natural surface freshwater through submerged deep-water outfalls is identified as a new unforeseen anthropogenic impact.

54 ENVIRONMENTAL SCIENCES↗

Interaction between Heat Pump Water Heaters or Other Internal Point Source Loads and a Central Heating System

Water heating represents approximately 18% of residential energy consumption, or 4.6 quadrillion Btus of source energy use annually (EIA 2009). Heat pump water heaters (HPWHs) offer an efficient option for residential water heating, with the ability to reduce water heating energy consumption by up to 63%. Previous research has demonstrated the laboratory performance of HPWHs and has shown savings of 43 to 62% on water heating energy consumption are possible, based on field tests (Ecotope 2015). In order to achieve such high efficiencies, HPWHs employ a refrigeration cycle to move heat from the ambient air into the water. Therefore, when HPWHs are installed in conditioned space, they will remove heat from that space which can help the HVAC system in the cooling season and require additional energy from the HVAC system in the heating season. This project provides an unbiased evaluation of the space conditioning interactions between a HPWH and the heating system in several locations throughout the home to further our understanding of the impact that HPWHs have on space conditioning loads. This report explores the HPWH interaction factor from several perspectives: (1) a theoretical analysis, (2) a review of previous literature, and (2) an experimental assessment. The experiments were conducted in PNNL’s side-by-side Lab Homes, which provide a platform for evaluating energy-saving and grid-responsive technologies in a controlled environment. The PNNL Lab Homes are two factory-built homes installed on PNNL’s campus in Richland, Washington. The homes represent existing homes, which account for approximately 99% of occupied homes in the U.S. These 1500 ft2 homes have three bedrooms, two bathrooms, and are equipped with 7.7 HSPF heat pump and an electric forced air furnace. Both homes have R-22 floors, R-11 walls and R-22 ceiling insulation levels, with double-pane clear glass windows. The results of this experiment verified that the energy use of the HVAC system increases as a point source cooling load, like a HPWH, is moved closer to the thermostat. The opposite is also true, as a point source heating load is moved closer to the thermostat, the heating load decreases. The results show between 30-40% difference between the interaction that this type of load has when it is placed in the master bathroom compared to the living room for the PNNL Lab Homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale Effects Masked the Impact of the COVID-19 Pandemic on Electricity Demand in the United States

Shelter-in-place orders and business closures related to COVID-19 changed the hourly profile of electricity demand and created an unprecedented source of uncertainty for the grid. The potential for continued shifts in electricity profiles has implications for electricity sector investment and operating decisions that maintain reserve margins and provide grid reliability. This study reveals that understanding this uncertainty requires an understanding of the underlying drivers at the customer-class scale. This paper utilizes three datasets to compare the impacts of COVID-19 on electricity consumption across a range of spatiotemporal and customer scales. At the utility/customer-class scale, COVID-19-induced shutdowns in the spring of 2020 shifted weekday residential load profiles to resemble weekend profiles from previous years. Total commercial loads declined, but the commercial diurnal load profile was unchanged. With only total loads available at the balancing authority scale, the apparent impact of COVID-19 was smaller during the summer due in part to phased re-opening and spatial variability in re-opening, but there were still clear variations once total loads were broken down zonally. Monthly data at the state scale showed an increase in state-level residential electricity sales, a decrease in commercial sales, and a small net decrease in total sales in most states from April-August 2020. Analyses that focus on total load or a single scale may miss important changes that become apparent when the load is broken down regionally or by customer class.

COVID-19, electricity demand, multiscale, Commonwe↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

Comparison of Fuel Loading Pattern Optimization Results using Exhaustive Search for Fresh Fuels and Local Search for Burned Fuels

Fuel loading pattern optimization is a combinatorial optimization problem from the mathematical point of view. However, exhaustive search is impractical because enormous computational cost is necessary due to huge search space. For this reason, various optimization methods have been developed so far, but no methods are able to guarantee to reach the optimum solution. In the present study, search space is divided into subspaces using key parameters that well represent characteristics of a loading pattern and then promising subspaces are extensively searched. In the present method, balance between division of a search space into subspaces and a search method used in a subspace is essential. For example, when the number of division is set to be one, it is equivalent to the exhaustive search thus is impractical. Similarly, when the division to subspaces is too coarse, an optimum (or near optimum) solution cannot be found through local search in each subspace since design space of a subspace is still too large. Contrary, if division to subspaces is too fine, number of subspaces becomes to large thus promising subspaces cannot be found. In the present study, search space is divided focusing on the location of fresh fuel assemblies with gadolinia since it has significant impact on core characteristics. Number of possible loading patterns of gadolinia bearing fresh fuel assemblies is not very large thus exhaustive search is possible. Local fine search is executed by considering location of burned fuels for each loading pattern of gadolinia bearing fresh fuel assembly. If the same solution is obtained by multiple local searches starting from different initial burnt fuel locations (but the same loading patterns for gadolinia bearing fresh fuel assemblies), the obtained solution is highly likely the optimum in the subspace. In more general, the present method is based on the 'divide and conquer' approach, which is familiar in the optimization field. Namely, after division of search space into subspaces and then promising subspace is searched. Once the promising subspace is found, the subspace is further subdivided into subspaces and repeat the above procedures. This method would be efficient when appropriate balance between search space division method and performance of local search is achieved. The previous works utilizes the similar approach. In reference [1], exhaustive search in small region in a core is carried out focusing on loading patterns of gadolinia bearing fresh fuel assemblies. In reference [2], rough exhaustive search based on the 'batch-wise' loading pattern is performed with the assist of the linear programming. By contrast, in the present study, exhaustive search is carried out for loading patterns of gadolinia bearing fresh fuel assemblies. The random Multi-start Local Search (MSLS) with the direct search or the exhaustive binary swap is used to find out optimal solutions in a subspace, which consists of loading patterns having the same arrangement of gadolinia bearing fresh fuel assemblies. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Graft Molecular Weight and Density on the Mechanical Properties of Polystyrene-Grafted Cellulose Nanocrystal Films

In this work, polymer-grafted nanoparticle (PGN) films were prepared from polystyrene (PS) grafted to rodlike cellulose nanocrystals (MxG-CNC-g-PS) with a controllable grafting density (0.03–0.25 chains/nm 2 ) and molecular weight (5–60 kg/mol). These nanorod-based PGNs are solution- and melt-processible, permitting access to one-component composite films with high nanofiller loadings (with up to 55 wt %). The impact of both grafted polymer density and molecular weight on the mechanical properties of the films was investigated and related to the polymer brush conformation: concentrated polymer brush (CPB), semidilute polymer brush (SDPB), or CPB core with SDPB corona (CPB/SDPB). The rubbery regime storage modulus (above $T_g$) showed 2 orders of magnitude increase, maximizing at a low degree of polymerization (N) and low grafting density (σ). Fracture toughness was maximized in samples with the grafted polymer in the SDPB or CPD/SDPB (higher N and relatively low σ) regime and showed enhancement relative to PS of molecular weight similar to the graft. In line with prior computation predictions, optimizing for both rubbery modulus and fracture toughness in such nanorod-based PGN films requires the polymers in the SDPB regime and CNC loading levels (ca. 50–60 wt %) that are difficult to attain in more traditional two-component CNC composites.

36 MATERIALS SCIENCE↗

Investigation of Membrane Chemical Degradation as a Function of Catalyst Platinum Loading

Membrane chemical degradation is one of many factors that can impact fuel cell durability. Additionally, the fuel cell’s lifetime heavily depends on the membrane and its ability to maintain chemical and mechanical integrity. Previous studies indicate that chemical degradation is due to the formation of hydroxyl radicals that attack the polymer structure resulting in membrane thinning, pinhole formation, and the release of fluoride and sulfate ions. Membrane durability was investigated using ultra-low Pt electrode loadings (≤ 0.1 mg Pt cm -2 ). Accelerated stress testing (US-DOE protocols) demonstrated that the degradation rate was found to increase with higher Pt loadings. This is most likely due to more heterogeneous sites for radical formation due to hydrogen crossover to the cathode. We also explored membrane degradation rates while varying catalyst layer thickness, ionomer to carbon ratio, and types of carbon support. All of the aforementioned variables impact the membrane degradation rates.

25 ENERGY STORAGE↗

Building Energy Systems as Behind-the-Meter Resources for Grid Services: Intelligent load control and transactive control and coordination

To mitigate the impacts of climate change, significant reductions in emissions from all sectors of the economy are needed. The electricity generation sector has embarked on an ambitious plan to include renewable generation as part of its decarbonization efforts, and many cities and states are mandating all-electric buildings. While renewable resources will reduce emissions, they are not dispatchable, they vary temporally, and their generation is uncertain. Under these conditions, traditional approaches to managing grid reliability, where supply follows demand, will not be efficient and may not be cost-effective. Further, there is a more efficient alternative for balancing the supply–demand imbalance and for absorbing variability and uncertainty of renewable energy using distributed energy resources (DERs) as opposed to reserve generation. Because buildings consume more than 75% of total U.S. annual electricity consumption, behind-the-meter (BTM) DERs have a load flexibility of 77 GW of power and 90 GWh of virtual energy storage capacity nationwide (Kalsi, 2017). Therefore, some portion of the supply–demand imbalance can be met by these DERs at a lower cost compared to business-as-usual solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Biofuel Blending on Hydrocarbon Speciation and Particulate Matter from a Medium-Duty Multimode Combustion Strategy

The U.S. Department of Energy’s Co-Optima initiative simultaneous focused on diversifying fuel sources, improving efficiency, and reducing emissions through using novel combustion strategies and sustainable fuel blends. For medium-duty/heavy-duty diesel engines, research in this area has led to the development of a multimode strategy that uses premixed charge compression ignition (PCCI) at low loads and conventional diesel combustion (CDC) at mid–high loads. The aim of this study was to understand how emissions were impacted when using PCCI instead of CDC at low loads and switching to an oxygenated biofuel blend. It provides a detailed speciation of the hydrocarbon (HC) and particulate matter (PM) emissions from a multimode medium-duty engine operating at low loads in PCCI and CDC modes and high loads in CDC. The effect of the oxygenated biofuel blend on emissions was studied at all three mode–load conditions using #2 ULSD and a bio-derived fuel (25% hexyl hexanoate (HHN)) blended in #2 ULSD. The PCCI mode effectively decreased NOx, total HC, and PM/PN emissions, with a substantial decrease in larger particles (≥50 nm). A PM/PN reduction was observed at high loads with the 25% HHN fuel. While the total HC emissions were not impacted by fuel type, the detailed HC analysis exposed changes in the HC’s composition.

09 BIOMASS FUELS↗

Integrated Two-Stage Alkaline-Oxidative Pretreatment of Hybrid Poplar. Part 1: Impact of Alkaline Pre-Extraction Conditions on Process Performance and Lignin Properties

We previously demonstrated that a two-stage pretreatment comprising of an alkaline pre-extraction followed by a Cu-catalyzed alkaline–oxidative treatment is effective at pretreating hardwoods under relatively mild reaction conditions. In this work, we focus on characterizing how biomass source and reaction conditions used during the alkaline pre-extraction impact the subsequent processing stages as well as lignin yields and properties. Specifically, three hybrid poplars were subjected to the first stage alkaline pre-extraction under various conditions including differences in time (15–300 min), temperature (95–155 °C), and alkali loadings (50–200 mg NaOH/g biomass), and the impact on total mass solubilization, lignin recovery, and lignin purity was determined. Empirical correlations were developed between reaction conditions and mass solubilization and lignin recovery during the pre-extraction stage. For select conditions, lignin properties were assessed and include β-O-4 content determined by 13C NMR, molecular mass distributions as determined by gel permeation chromatography, and susceptibility to depolymerization to aromatic monomers using thioacidolysis and formic acid catalyzed depolymerization. We found alkaline pre-extraction performed at higher temperatures generated lignins exhibiting lower contamination by polysaccharides, lower aromatic monomer yields from depolymerization, lower molar masses, and lower β-O-4 contents relative to the lower temperature pre-extractions. Lastly, the pre-extracted biomass from select conditions was assessed for its response to the subsequent Cu-catalyzed alkaline–oxidative treatment and enzymatic hydrolysis. It was demonstrated that minor differences in delignification during pre-extraction have quantifiable impacts on the subsequent efficacy of the second stage of pretreatment and enzymatic hydrolysis with improved lignin removal during the first pre-extraction stage resulting in improved hydrolysis yields.

09 BIOMASS FUELS↗

Role of initial conditions in plasma-current coupling of gas-puff Z-pinches

Azimuthal magnetic field measurements obtained during the implosion phase of an oxygen gas-puff Z-pinch on a 500 kA peak current and 180 ns rise time linear transformer driver are presented. While a fraction of the driver current was measured within the imploding plasma, key initial conditions were found to significantly impact the delivery of current to the plasma load. The electrode geometry was modified to assist the initial dielectric breakdown and resulted in improved shot reproducibility. Optimization of the gas injection plenum pressure and timing resulted in an increase in the current coupling parameter, defined as the ratio of the measured value of $B$ $θ$ to the expected value, from 50% to 75%. Furthermore, the degree of radial expansion of the gas puff in the load region, which is suspected to lead to the observed current loss during the implosion, was reduced by shortening the valve opening duration. Additionally, a pre-embedded axial magnetic field of up to 0.2 T was found to have no significant impact on the plasma-current coupling of the oxygen implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the Effect of Economic Development Zones on Electrical Load Growth in Kentucky [Slides]

The Kentucky Energy and Environment Cabinet has recently undertaken a comprehensive effort to map and catalog potential economic development sites across the state. The purpose of this technical assistance is to quantify the potential impact of developing designated sites on Kentucky's electricity load growth, providing insights at both state and county level considering the next 10 years. This analysis should explicitly incorporate and address key project uncertainties by developing various load growth scenarios that account for development scale, site specificity, and sector variability. The need for a site-specific analysis comes from the understanding that conventional econometric (top-down) load forecasting models cannot sufficiently isolate or predict the discrete load increases resulting from the development of these unique and targeted economic sites.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗