Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

High resolution photoelectron imaging of UO{sup −} and UO{sub 2}{sup −} and the low-lying electronic states and vibrational frequencies of UO and UO{sub 2}

We report a study of the electronic and vibrational structures of the gaseous uranium monoxide and dioxide molecules using high-resolution photoelectron imaging. Vibrationally resolved photoelectron spectra are obtained for both UO{sup −} and UO{sub 2}{sup −}. The spectra for UO{sub 2}{sup −} are consistent with, but much better resolved than a recent study using a magnetic-bottle photoelectron analyzer [W. L. Li et al., J. Chem. Phys. 140, 094306 (2014)]. The electron affinity (EA) of UO is reported for the first time as 1.1407(7) eV, whereas a much more accurate EA is obtained for UO{sub 2} as 1.1688(6) eV. The symmetric stretching modes for the neutral and anionic ground states, and two neutral excited states for UO{sub 2} are observed, as well as the bending mode for the neutral ground state. These vibrational frequencies are consistent with previous experimental and theoretical results. The stretching vibrational modes for the ground state and one excited state are observed for UO. The current results for UO and UO{sub 2} are compared with previous theoretical calculations including relativistic effects and spin-orbit coupling. The accurate experimental data reported here provide more stringent tests for future theoretical methods for actinide-containing species.

74 ATOMIC AND MOLECULAR PHYSICS↗

Crossed-beam DC slice imaging of fluorine atom reactions with linear alkanes

We report the reaction dynamics of F atom with selected alkanes studied by crossed beam scattering with DC slice ion imaging. The target alkanes are propane, n-butane, and n-pentane. The product alkyl radicals are probed by 157 nm single photon ionization following reaction at a collision energy of ∼10 kcal mol{sup −1}. The analyzed data are compared with the corresponding theoretical studies. Reduced translational energy distributions for each system show similar trends with little of the reaction exoergicity appearing in translation. However, the pentane reaction shows a somewhat smaller fraction of available energy in translation than the other two, suggesting greater energy channeled into pentyl internal degrees of freedom. The center-of-mass angular distributions all show backscattering as well as sharp forward scattering that decreases in relative intensity with the size of the molecule. Possible reasons for these trends are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging the oblique propagation of electrons in germanium crystals at low temperature and low electric field

Excited electrons in the conduction band of germanium collect into four energy minima, or valleys, in momentum space. These local minima have highly anisotropic mass tensors which cause the electrons to travel in directions which are oblique to an applied electric field at sub-Kelvin temperatures and low electric fields, in contrast to the more isotropic behavior of the holes. This experiment produces a full two-dimensional image of the oblique electron and hole propagation and the quantum transitions of electrons between valleys for electric fields oriented along the [0,0,1] direction. Charge carriers are excited with a focused laser pulse on one face of a germanium crystal and then drifted through the crystal by a uniform electric field of strength between 0.5 and 6 V/cm. The pattern of charge density arriving on the opposite face is used to reconstruct the trajectories of the carriers. Measurements of the two-dimensional pattern of charge density are compared in detail with Monte Carlo simulations developed for the Cryogenic Dark Matter Search (SuperCDMS) to model the transport of charge carriers in high-purity germanium detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

Investigating the relationship between noise transfer inside the x-ray framing cameras and their imaging ability

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector’s output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector’s response to a uniform illumination. We also reflect that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative method to the usual avenue employed to measure their modulation transfer functions.

25 ENERGY STORAGE↗

In situ X-ray imaging of heterogeneity in dynamic compaction of granular media

Dynamic compaction of granular materials is a complex process wherein the material response at the continuum scale arises from fracture, comminution, and fragment ow at the grain scale. Granular materials have heterogeneity due to variation in grain properties, as well as variation in local packing density and structure. These heterogeneities may affect the dynamic compaction response, producing a structured and time-varying compaction front. Methodology used to characterize the shock behavior in solid materials may be inappropriate for granular materials, because of this unsteady behavior and interactions between the granular material and measurement surfaces. To observe the compaction front heterogeneity, in-situ x-ray imaging of granular compaction is conducted at a scale between the grain- and continuum scales. To allow for sufficient x-ray transmission, a thin sample geometry is used, for which boundary affects may result in a significantly different load path than would occur in a 1-D compaction configuration. Numerical simulations of the experimental geometry support analysis of the results so that the feature of the compaction front can be distinguished from artifacts of the experimental configuration. The results suggest compaction front heterogeneity may have structure with a length scale of tens of particle diameters, and demonstrate that finite grain size can inhibit the formation shear-induced features that would arise in a homogenized representation of the same material.

36 MATERIALS SCIENCE↗

X-ray imaging of liquid-liquid Mg cavitation

The coupling of dynamic loading platforms with synchrotron light sources have enabled experiments examining void formation in optically opaque materials. Much like spallation in a solid, cavitation occurs when rarefaction waves collide within a liquid. The resulting deformation leads to a complex flow field with numerous voids. It has been suggested that compaction of such a structure may be a significant source of ejecta (i.e. shallow bubble collapse). Experiments imaging supported and unsupported shocks interacting with a free surface in shock melted Mg with synchrotron radiation are presented. Here, the results are used to examine the structure of a cavitation plane that forms in the unsupported case and provide an estimate of the porosity within this region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utilisation of spatial derivative measurements in circular diffuse optical tomographic imaging to improve image resolution and contrast

The resolution of images recovered using diffuse optical tomography without spatial prior information is inherently limited due to the diffusive nature of light transport in scattering dominated biological tissue. Several studies have previously reported an improvement in depth sensitivity in near infrared spectroscopy by considering the subtraction of two neighbouring measurements. A nearest neighbour, spatial derivative based algorithm is presented, in which the difference between neighbouring source-sharing source – detector pairs is considered for tomographic reconstruction. Using a circular, inward-facing optode geometry, it is shown that deeper abnormalities in oxyhaemoglobin, deoxyhaemoglobin and water can be recovered with better localisation and contrast as compared to reconstructing using absolute values of multi-wavelength data. Relative improvements of up to 25 % in quantitative accuracy of recovered physiological values are demonstrated at better resolution for cancerous tissue in a heterogeneous breast model, when using this proposed spatial derivative based parameter reconstruction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging via complete cantilever dynamic detection: General dynamic mode imaging and spectroscopy in scanning probe microscopy

We develop and implement a multifrequency spectroscopy and spectroscopic imaging mode, referred to as general dynamic mode (GDM), that captures the complete spatially- and stimulus dependent information on nonlinear cantilever dynamics in scanning probe microscopy (SPM). GDM acquires the cantilever response including harmonics and mode mixing products across the entire broadband cantilever spectrum as a function of excitation frequency. GDM spectra substitute the classical measurements in SPM, e.g. amplitude and phase in lock-in detection. Here, GDM is used to investigate the response of a purely capacitively driven cantilever. We use information theory techniques to mine the data and verify the findings with governing equations and classical lock-in based approaches. We explore the dependence of the cantilever dynamics on the tip–sample distance, AC and DC driving bias. This approach can be applied to investigate the dynamic behavior of other systems within and beyond dynamic SPM. In conclusion, GDM is expected to be useful for separating the contribution of different physical phenomena in the cantilever response and understanding the role of cantilever dynamics in dynamic AFM techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging the spatial form of a superconducting order parameter via Josephson scanning tunneling spectroscopy

Motivated by recent experiments, we investigate Josephson scanning tunneling spectroscopy in an s-wave superconductor. Here, we demonstrate that the spatial oscillations in the superconducting order parameter induced by defects can be spatially imaged through local measurements of the critical Josephson current, providing unprecedented insight into the nature of superconductivity. The spatial form of the Josephson current reflects the nature of the defects, and can be used to probe defect-induced phase transitions from an S = 0 to an S = 1/2 ground state.

Graham, Martin↗

Sci—Thur PM: Imaging — 01: Position-sensitive noise characteristics in multi-pinhole cardiac SPECT imaging

Myocardial perfusion imaging (MPI) with Single Photon Emission Computed Tomography (SPECT) is invaluable in the diagnosis and management of heart disease. It provides essential information on myocardial blood flow and ischemia. Multi-pinhole dedicated cardiac-SPECT cameras offer improved count sensitivity, and spatial and energy resolutions over parallel-hole camera designs however variable sensitivity across the field-of-view (FOV) can lead to position-dependent noise variations. Since MPI evaluates differences in the signal-to-noise ratio, noise variations in the camera could significantly impact the sensitivity of the test for ischemia. We evaluated the noise characteristics of GE Healthcare's Discovery NM530c camera with a goal of optimizing the accuracy of our patient assessment and thereby improving outcomes. Theoretical sensitivity maps of the camera FOV, including attenuation effects, were estimated analytically based on the distance and angle between the spatial position of a given voxel and each pinhole. The standard deviation in counts, σ was inferred for each voxel position from the square root of the sensitivity mapped at that position. Noise was measured experimentally from repeated (N=16) acquisitions of a uniform spherical Tc-99m-water phantom. The mean (μ) and standard deviation (σ) were calculated for each voxel position in the reconstructed FOV. Noise increased ∼2.1× across a 12 cm sphere. A correlation of 0.53 is seen when experimental noise is compared with theory suggesting that ∼53% of the noise is attributed to the combined effects of attenuation and the multi-pinhole geometry. Further investigations are warranted to determine the clinical impact of the position-dependent noise variation.

60 APPLIED LIFE SCIENCES↗

Imaging orbital ferromagnetism in a moiré Chern insulator

Capturing exotic magnetism Ferromagnetism is associated with the breaking of time-reversal symmetry, most frequently by the spin degree of freedom. Although the orbital motion of electrons can also contribute to ferromagnetism, in most materials, it is small relative to the spin contribution. Tschirhart et al. showed that the reverse is true in an unusual magnetic state hosted by twisted bilayer graphene. Their scanning magnetometry measurements were consistent with ferromagnetism of predominantly orbital origin. Science , abd3190, this issue p. 1323

Science & Technology - Other Topics↗