Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A forward model-based validation of cardiovascular system identification

We present a theoretical evaluation of a cardiovascular system identification method that we previously developed for the analysis of beat-to-beat fluctuations in noninvasively measured heart rate, arterial blood pressure, and instantaneous lung volume. The method provides a dynamical characterization of the important autonomic and mechanical mechanisms responsible for coupling the fluctuations (inverse modeling). To carry out the evaluation, we developed a computational model of the cardiovascular system capable of generating realistic beat-to-beat variability (forward modeling). We applied the method to data generated from the forward model and compared the resulting estimated dynamics with the actual dynamics of the forward model, which were either precisely known or easily determined. We found that the estimated dynamics corresponded to the actual dynamics and that this correspondence was robust to forward model uncertainty. We also demonstrated the sensitivity of the method in detecting small changes in parameters characterizing autonomic function in the forward model. These results provide confidence in the performance of the cardiovascular system identification method when applied to experimental data.

NASA Discipline Cardiopulmonary↗

LabHEART: an interactive computer model of rabbit ventricular myocyte ion channels and Ca transport

An interactive computer program, LabHEART, was developed to simulate the action potential (AP), ionic currents, and Ca handling mechanisms in a rabbit ventricular myocyte. User-oriented, its design allows switching between voltage and current clamp and easy on-line manipulation of key parameters to change the original formulation. The model reproduces normal rabbit ventricular myocyte currents, Ca transients, and APs. We also changed parameters to simulate data from heart failure (HF) myocytes, including reduced transient outward (I(to)) and inward rectifying K currents (I(K1)), enhanced Na/Ca exchange expression, and reduced sarcoplasmic reticulum Ca-ATPase function, but unaltered Ca current density. These changes caused reduced Ca transient amplitude and increased AP duration (especially at lower frequency) as observed experimentally. The model shows that the increased Na/Ca exchange current (I(NaCa)) in HF lowers the intracellular [Ca] threshold for a triggered AP from 800 to 540 nM. Similarly, the decrease in I(K1) reduces the threshold to 600 nM. Changes in I(to) have no effect. Combining enhanced Na/Ca exchange with reduced I(K1) (as in HF) lowers the threshold to trigger an AP to 380 nM. These changes reproduce experimental results in HF, where the contributions of different factors are not readily distinguishable. We conclude that the triggered APs that contribute to nonreentrant ventricular tachycardia in HF are due approximately equally (and nearly additively) to alterations in I(NaCa) and I(K1). A free copy of this software can be obtained at http://www.meddean.luc.edu/lumen/DeptWebs/physio/bers.html.

NASA Discipline Cardiopulmonary↗

Artificial gravity: head movements during short-radius centrifugation

Short-radius centrifugation is a potential countermeasure to long-term weightlessness. Unfortunately, head movements in a rotating environment induce serious discomfort, non-compensatory vestibulo-ocular reflexes, and subjective illusions of body tilt. In two experiments we investigated the effects of pitch and yaw head movements in participants placed supine on a rotating bed with their head at the center of rotation, feet at the rim. The vast majority of participants experienced motion sickness, inappropriate vertical nystagmus and illusory tilt and roll as predicted by a semicircular canal model. However, a small but significant number of the 28 participants experienced tilt in the predicted plane but in the opposite direction. Heart rate was elevated following one-second duration head turns. Significant adaptation occurred following a series of head turns in the light. Vertical nystagmus, motion sickness and illusory tilt all decreased with adaptation. Consequences for artificial gravity produced by short-radius centrifuges as a countermeasure are discussed. Grant numbers: NCC 9-58. c 2001. Elsevier Science Ltd. All rights reserved.

Non-NASA Center↗

Increases in intramuscular pressure raise arterial blood pressure during dynamic exercise

This investigation was designed to determine the role of intramuscular pressure-sensitive mechanoreceptors and chemically sensitive metaboreceptors in affecting the blood pressure response to dynamic exercise in humans. Sixteen subjects performed incremental (20 W/min) cycle exercise to fatigue under four conditions: control, exercise with thigh cuff occlusion of 90 Torr (Cuff occlusion), exercise with lower body positive pressure (LBPP) of 45 Torr, and a combination of thigh cuff occlusion and LBPP (combination). Indexes of central command (heart rate, oxygen uptake, ratings of perceived exertion, and electromyographic activity), cardiac output, stroke volume, and total peripheral resistance were not significantly different between the four conditions. Mechanical stimulation during LBPP and combination conditions resulted in significant elevations in intramuscular pressure and mean arterial pressure from control at rest and throughout the incremental exercise protocol (P < 0.05). Conversely, there existed no significant changes in mean arterial pressure when the metaboreflex was stimulated by cuff occlusion. These findings suggest that under normal conditions the mechanoreflex is tonically active and is the primary mediator of exercise pressor reflex-induced alterations in arterial blood pressure during submaximal dynamic exercise in humans.

Non-NASA Center↗

Circadian rhythms in Macaca mulatta monkeys during Bion 11 flight

Circadian rhythms of primate brain temperature, head and ankle skin temperature, motor activity, and heart rate were studied during spaceflight and on the ground. In space, the circadian rhythms of all the parameters were synchronized with diurnal Zeitgebers. However, in space the brain temperature rhythm showed a significantly more delayed phase angle, which may be ascribed to an increase of the endogenous circadian period.

Non-NASA Center↗

Stochastic feedback and the regulation of biological rhythms

We propose a general approach to the question of how biological rhythms spontaneously self-regulate, based on the concept of "stochastic feedback". We illustrate this approach by considering at a coarse-grained level the neuroautonomic regulation of the heart rate. The model generates complex dynamics and successfully acounts for key characteristics of cardiac variability, including the l/f power spectrum, the functional form and scaling of the distribution of variations, and correlations in the Fourier phases indicating nonlinear dynamics.

NASA Discipline Cardiopulmonary↗

The autonomic laboratory

The autonomic nervous system can now be studied quantitatively, noninvasively, and reproducibly in a clinical autonomic laboratory. The approach at the Mayo Clinic is to study the postganglionic sympathetic nerve fibers of peripheral nerve (using the quantitative sudomotor axon reflex test [QSART]), the parasympathetic nerves to the heart (cardiovagal tests), and the regulation of blood pressure by the baroreflexes (adrenergic tests). Patient preparation is extremely important, since the state of the patient influences the results of autonomic function tests. The autonomic technologist in this evolving field needs to have a solid core of knowledge of autonomic physiology and autonomic function tests, followed by training in the performance of these tests in a standardized fashion. The range and utilization of tests of autonomic function will likely continue to evolve.

NASA Discipline Cardiopulmonary↗

Transfer function analysis of the autonomic response to respiratory activity during random interval breathing

We report a new method for the noninvasive characterization of the frequency response of the autonomic nervous system (ANS) in mediating fluctuations in heart rate (HR). The approach entails computation of the transfer function magnitude and phase between instantaneous lung volume and HR. Broad band fluctuations in lung volume were initiated when subjects breathed on cue to a sequence of beeps spaced randomly in time. We studied 10 subjects in both supine and standing positions. The transfer function, averaged among all the subjects, showed systematic differences between the two postures, reflecting the differing frequency responses of the sympathetic and parasympathetic divisions of the ANS.

Non-NASA Center↗

Detection of chaotic determinism in time series from randomly forced maps

Time series from biological system often display fluctuations in the measured variables. Much effort has been directed at determining whether this variability reflects deterministic chaos, or whether it is merely "noise". Despite this effort, it has been difficult to establish the presence of chaos in time series from biological sytems. The output from a biological system is probably the result of both its internal dynamics, and the input to the system from the surroundings. This implies that the system should be viewed as a mixed system with both stochastic and deterministic components. We present a method that appears to be useful in deciding whether determinism is present in a time series, and if this determinism has chaotic attributes, i.e., a positive characteristic exponent that leads to sensitivity to initial conditions. The method relies on fitting a nonlinear autoregressive model to the time series followed by an estimation of the characteristic exponents of the model over the observed probability distribution of states for the system. The method is tested by computer simulations, and applied to heart rate variability data.

Non-NASA Center↗

Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.

Non-NASA Center↗

Effects of a gravity gradient on human cardiovascular responses

Eight subjects participated in one control and three rotation trials on a short-arm centrifuge such that the Gz levels at the feet were 0.5, 1.0, and 1.5 G. Trials consisted of 30 minutes of supine rest, 1 hour of rotation (or in the control, 30 additional minutes of rest and 30 minutes of standing), and a final 30-minute rest period. Measurements of heart rate, calf impedance, calf volume, and blood pressure support the findings that the highest G level is similar to standing and that the lower G levels fail to produce significant effects.

NASA Discipline Cardiopulmonary↗

Pre-exercise hypervolemia and cycle ergometer endurance in men

Time to exhaustion at 87-91% of peak VO2 was measured in 5 untrained men (age: 31 +/- 8 years, body mass: 74.20 +/- 16.50 kg, body surface area: 1.90 +/- 0.24 m2, peak VO2: 2.87 +/- 0.40 l min-1, plasma volume: 3.21 +/- 0.88 l; means +/-SD) after consuming nothing (N) or two fluid formulations (10 ml kg-1, 743 +/- 161 ml): Performance 1 (P1), a multi-ionic carbohydrate drink, containing 55 mEq l-1 Na+, 4.16 g l-1 citrate, 20.49 g l-1 glucose, and 365 mOsm kg-1 H2O, and AstroAde (AA), a sodium chloride-sodium citrate hyperhydration drink, containing 164 mEq l-1 Na+, 8.54 g l-1 citrate, <5 mg l-1 glucose, and 253 mOsm kg-1 H2O. Mean (+/-SE) endurance for N, P1 and AA was 24.68 +/- 1.50, 24.55 +/- 1.09, and 30.50 +/- 3.44 min respectively. Percent changes in plasma volume (PV) from -105 min of rest to zero min before exercise were -1.5 +/- 3.2% (N), 0.2 +/- 2.2% (P1), and 4.8 +/- 3.0% (AA; P < 0.05). The attenuated endurance for N and P1 could not be attributed to differences in exercise metabolism (VE, RE, VO2) from the carbohydrate or citrate, terminal heart rate, levels of perceived exertion, forehead or thigh skin blood flow velocity, changes or absolute termination levels of rectal temperature. Thus, the higher level of resting PV for AA just before exercise, as well as greater acid buffering and possible increased energy substrate from citrate, may have contributed to the greater endurance.

NASA Center ARC↗

Cardiovascular responses of semi-arboreal snakes to chronic, intermittent hypergravity

Cardiovascular functions were studied in semi-arboreal rat snakes (Elaphe obsoleta) following long-term, intermittent exposure to +1.5 Gz (head-to-tail acceleration) on a centrifuge. Snakes were held in a nearly straight position within horizontal plastic tubes during periods of centrifugation. Centrifugal acceleration, therefore, subjected snakes to a linear force gradient with the maximal force being experienced at the tail. Compared to non-centrifuged controls, Gz-acclimated snakes showed greater increases of heart rate during head-up tilt or acceleration, greater sensitivity of arterial pressure to circulating catecholamines, higher blood levels of corticosterone, and higher blood ratios of prostaglandin F 2 alpha/prostaglandin E2. Cardiovascular tolerance to increased gravity during graded Gz acceleration was measured as the maximum (caudal) acceleration force at which carotid arterial blood flow became null. When such tolerances were adjusted for effects of body size and other continuous variables incorporated into an analysis of covariance, the difference between the adjusted mean values of control and acclimated snakes (2.37 and 2.84 Gz, respectively) corresponded closely to the 0.5 G difference between the acclimation G (1.5) and Earth gravity (1.0). As in other vertebrates, cardiovascular tolerance to Gz stress tended to be increased by acclimation, short body length, high arterial pressure, and comparatively large blood volume. Voluntary body movements were important for promoting carotid blood flow at the higher levels of Gz stress.

NASA Discipline Cardiopulmonary↗

Effects of three day bed-rest on circulatory, metabolic and hormonal responses to oral glucose load in endurance trained athletes and untrained subjects

Endurance trained long distance runners and untrained individuals underwent three days of bed rest and oral glucose loading. Before and after bed rest, individuals were given glucose tolerance tests, and their heart rates, blood pressure, blood glucose levels, insulin levels, and catecholamine interactions were measured. Results indicated that glucose tolerance is more affected by bed rest-induced deconditioning in untrained individuals than in trained individuals.

NASA Discipline Regulatory Physiology↗

Effect of three day bed-rest on circulatory and hormonal responses to active orthostatic test in endurance trained athletes and untrained subjects

Circulatory and hormonal parameters were measured in endurance-trained athletes and control subjects during orthostatic tolerance tests conducted prior to and after three days of bed rest. Heart rate and blood pressure changes due to bed rest appeared to be the same in both groups. Hormonal changes, however, were different between the two groups, with the athletes having decreased sympathoadrenal activity and increased plasma renin activity. Untrained subjects had changes in cortisol secretion only.

NASA Center ARC↗

Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: assessment with Holter monitoring

This article presents selected findings obtained with Holter monitoring from two crew members of the expedition, performed during a 175-day space mission on board orbital space station "MIR." Using mathematical processing of daily cardiointervals files, 5-minute sections of records were analyzed consecutively. Then, the average daily values of indices, the average-per-every-eight-hours values (morning, evening, night) and mean values per hour were computed. The results of analysis showed that prolonged exposure of man to microgravity conditions leads to important functional alteration in human neuroautonomic regulatory mechanisms. Both crew members had significant increase of heart rate, the rise of stress index, the decrease in power of the spectrum in the range of respiratory sinus arrhythmia. These marked signs of activation of the sympathetic section of the vegetative nervous system showed individual variations. The analysis of the daily collection of cardiointervals with Holter monitoring allows us to understand and forecast the functional feasibilities of the human organism under a variety of stress conditions associated with acute and chronic microgravity exposure.

manned↗

Right and left ventricular volumes in vitro by a new nongeometric method

We present an evaluation of a new nongeometric technique for calculating right and left ventricular volumes. This method calculates ventricular chamber volumes from multiple cross-sectional echocardiographic views taken from a single point as the echo beam is tilted progressively through the ventricle. Right and left ventricular volumes are calculated from both the approximate short axis and approximate apical position on 20 in vitro human hearts and compared with the actual chamber volumes. The results for both ventricles from both positions are excellent. Correlation coefficients are > 0.95 for all positions; the standard errors are in the range of 5 to 7 mL and the slopes and intercepts for the regression lines are not significantly different from 1 and 0, respectively (except for the left ventricular short-axis intercept). For all positions, approximately 6 to 8 views are needed for peak accuracy (7.5 degrees to 10 degrees separation). This approach offers several advantages. No geometric assumptions about ventricular shape are made. All images are acquired from a single point (or window), and the digitized points can be used to make a three-dimensional reconstruction of the ventricle. Also, during the calculations a volume distribution curve for the ventricle is produced. The shape of this curve can be characteristic for certain situations (ie, right ventricle, short axis) and can be used to make new simple equations for calculating volume. We conclude that this is an accurate nongeometric method for determining both right and left ventricular volumes in vitro.

NASA Discipline Cardiopulmonary↗

Correlation of macro and micro cardiovascular function during weightlessness and simulated weightlessness

The investigation of cardiovascular function necessarily involves a consideration of the exchange of substances at the capillary. If cardiovascular function is compromised or in any way altered during exposure to zero gravity in space, then it stands to reason that microvascular function is also modified. We have shown that an increase in cardiac output similar to that reported during simulated weightlessness is associated with a doubling of the number of post-capillary venules and a reduction in the number of arterioles by 35%. If the weightlessness of space travel produces similar changes in cardiopulmonary volume and cardiac output, a reasonable expectation is that astronauts will undergo venous neovascularization. We have developed an animal model in which to correlate microvascular and systemic cardiovascular function. The microcirculatory preparation consists of a lightweight, thermo-neutral chamber implanted around intact skeletal muscle on the back of a rat. Using this technique, the performed microvasculature of the cutaneous maximus muscle may be observed in the conscious, unanesthetized animal. Microcirculatory variables which may be obtained include venular and arteriolar numbers, lengths and diameters, single vessel flow velocities, vasomotion, capillary hematocrit anastomoses and orders of branching. Systemic hemodynamic monitoring of cardiac output by electromagnetic flowmetry, and arterial and venous pressures allows correlation of macro- and microcirculatory changes at the same time, in the same animal. Observed and calculated hemodynamic variables also include pulse pressure, heart rate, stroke volume, total peripheral resistance, aortic compliance, minute work, peak aortic flow velocity and systolic time interval. In this manner, an integrated assessment of total cardiovascular function may be obtained in the same animal without the complicating influence of anesthetics.

NASA Discipline Number 00-00↗