Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GROUNDWATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Reactive Transport of the Uranyl Ion in Soils, Sediments, and Groundwater Systems

Uranium is a ubiquitous trace component in rocks ranging from 1.2 to 1.3 µg g-1 in sedimentary rocks, 2.2 to 15 µg g-1 in granites, and 20 to 120 µg g-1 in phosphates (Langmuir, 1997; Plant et al., 1999). Uranium (U) is released to natural waters in dilute concentrations (generally < 10-7 mole L-1) from the weathering of these sources, with water concentrations in uraniferous geologic terrains, such as the southwestern U.S. (USGS, 2011), being higher (~ 10-6.5 mol L-1). Elevated water-borne concentrations are associated with the weathering of natural ore bodies [~10-6 mol L-1; e.g, (Payne and Airey, 2006)], the extraction and mining of U for armaments (Jiang and Aschner, 2009; WHO, 2001) and nuclear fuels [10-6 to 10-3 mol L-1; (Abdelouas et al., 1999)], and the disposal of waste solids and liquids from nuclear fuels reprocessing and arms production [~ 10-6 to 10-2 mol L-1; e.g., (Wan et al., 2009; Zachara et al., 2007)]. The form of U present in natural waters at high concentration is generally the uranyl ion [e.g., UO22+] which is quite soluble. Groundwater in many parts of the world contains dissolved U originating from natural and anthropogenic sources (ATSDR, 2011; EFSA, 2009). Low levels of dissolved U in drinking water are considered a health concern, causing renal and other effects (Kurttio et al., 2002; Kurttio et al., 2005; Limson Zamora et al., 1998; Nriagu et al., 2012; Raymond-Whish et al., 2007; Selden et al., 2009). The U.S. Environmental Protection Agency has established a regulatory drinking water standard of 30 µg L-1 (1.26 x 10-7 mol L-1) or 30 pCi L-1, whichever is exceeded first. The World Health Organization has recommended an even lower drinking water standard of 15 µg L-1 [6.3 x 10-8 mol L-1; (WHO, 2005)]. Human exposure to U through drinking water is expected to rise as world-wide reliance on groundwater sources increase (ESS, 2010).

Environmental Molecular Sciences Laboratory↗

In Situ: Groundwater Bioremediation

In situ groundwater bioremediation of hydrocarbons has been used for more than 40 years. Most strategies involve biostimulation; however, recently bioaugmentation have been used for dehalorespiration. Aquifer and contaminant profiles are critical to determining the feasibility and strategy for in situ groundwater bioremediation. Hydraulic conductivity and redox conditions, including concentrations of terminal electron acceptors, are critical to determine the feasibility and strategy for potential bioremediation applications. Conceptual models followed by characterization and subsequent numerical models are critical for efficient and cost-effective bioremediation. Critical research needs in this area include better modeling and integration of remediation strategies with natural attenuation.

Hazen, Terry C.↗

Application of State and Federal Guidelines for Establishing Alternate Soil Clean-Up Levels for the Protection of Groundwater at the Hanford Site

Risk-based soil cleanup levels that are protective of groundwater have been calculated for use in environmental remediation activities at the Hanford Site using vadose zone fate and transport modeling. The determination of soil cleanup levels is important because it involves the technical basis for the levels of contamination that can be left in place, which are protective of human health and the environment. The determination of risk-based soil cleanup levels is an especially important issue at the Hanford Site where site conditions such as a semi-arid climate, and a thick vadose zone of over 100 meters necessitate the use of appropriate risk-based methods. In the absence of an alternative risk-based approach, the cleanup levels default to background, detection limits, or simplistic formulas not intended for applications involving these distinctive site conditions. However, the use of vadose zone fate and transport modeling for risk-based applications such as the determination of soil cleanup levels in the vadose zone are not as well established as modeling for groundwater applications. Thus, the use of models in this manner involves additional challenges for the demonstration of the efficacy of its use for risk-based applications, in accordance with federal and state regulatory requirements and guidelines. An approach has been developed to integrate with federal and state regulatory guidelines in conjunction with the development of the risk-based methodology. Demonstration of integration with these guidelines primarily involves documentation of the objectives of the problem to be solved, the technical basis and rationale associated with the selection of an appropriate risk-based method (e.g., model type and code selection), and documentation associated with the use of the model, e.g., conceptual site model, parameter estimation, uncertainty and assumptions analyses, and model results. (authors)

54 ENVIRONMENTAL SCIENCES↗

Environmental Aspects of Two Volatile Organic Compound Groundwater Treatment Designs at the Rocky Flats Site - 13135

DOE's Rocky Flats Site in Colorado is a former nuclear weapons production facility that began operations in the early 1950's. Because of releases of hazardous substances to the environment, the federally owned property and adjacent offsite areas were placed on the CERCLA National Priorities List in 1989. The final remedy was selected in 2006. Engineered components of the remedy include four groundwater treatment systems that were installed before closure as CERCLA-accelerated actions. Two of the systems, the Mound Site Plume Treatment System and the East Trenches Plume Treatment System, remove low levels of volatile organic compounds using zero-valent iron media, thereby reducing the loading of volatile organic compounds in surface water resulting from the groundwater pathway. However, the zero-valent iron treatment does not reliably reduce all volatile organic compounds to consistently meet water quality goals. While adding additional zero-valent iron media capacity could improve volatile organic compound removal capability, installation of a solar powered air-stripper has proven an effective treatment optimization in further reducing volatile organic compound concentrations. A comparison of the air stripper to the alternative of adding additional zero-valent iron capacity to improve Mound Site Plume Treatment System and East Trenches Plume Treatment System treatment based on several key sustainable remediation aspects indicates the air stripper is also more 'environmentally friendly'. These key aspects include air pollutant emissions, water quality, waste management, transportation, and costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater Monitoring Report Generation Tools - 12005

Compliance with National and State environmental regulations (e.g. Resource Conservation and Recovery Act (RCRA) and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) aka SuperFund) requires Savannah River Site (SRS) to extensively collect and report groundwater monitoring data, with potential fines for missed reporting deadlines. Several utilities have been developed at SRS to facilitate production of the regulatory reports which include maps, data tables, charts and statistics. Components of each report are generated in accordance with complex sets of regulatory requirements specific to each site monitored. SRS developed a relational database to incorporate the detailed reporting rules with the groundwater data, and created a set of automation tools to interface with the information and generate the report components. These process improvements enhanced quality and consistency by centralizing the information, and have reduced manpower and production time through automated efficiencies. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemistry and Engineering Aspects of the Application of Soluble Phosphates for Uranium Treatment in Groundwater - 17255

Treatment of uranium in groundwater is challenging because of the equilibrium partitioning of uranium between sorbed and aqueous phase complexes in mobile and immobile pore space. In situ groundwater treatment strategies for uranium hold promise because of their reliance on fundamentally altering uranium chemical speciation as well as aquifer geochemical conditions. For the last 30 years uranium in situ reductive precipitation has been the leading technology; however, there have been only a handful of large-scale applications. Recently, within the last 10 years, the application of soluble phosphates has been identified as a viable means of treating soluble uranium, while at the same time changing the balance in terms of the availability of sorbed/immobile uranium to re-mobilize. Uranium reacts with soluble phosphate to form a range of low-solubility uranium minerals; surface passivation can also result, limiting the availability of uranium for dissolution. Here we discuss the application of dissolved phosphate in a small-scale pilot test in a tailings pile. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Large-Scale Implementation of Recirculation Systems for In-Situ Treatment of Hexavalent Chromium in Groundwater in Hinkley CA - 17338

In-situ remediation using recirculation systems is being used to treat hexavalent chromium (Cr[VI]) in groundwater within the plume core at the Pacific Gas and Electric Company Hinkley Compressor Station in Hinkley, California (the Site). In-situ Reactive Zones (IRZs) are currently treating an area of 0.8 kilometers (km, one-half of a mile) by 1.6 km (a mile) to target treatment of the core of the Cr(VI) plume, where concentrations of Cr(VI) range from 10 s of micrograms per liter (μg/L) to several milligrams per liter (mg/L). Following pilot testing from 2004-2006, large scale implementation of in-situ remediation began in late 2007 and has been on-going. Implementation of the recirculation systems has been successful in remediating Cr(VI) in groundwater at a large scale. Through Third Quarter 2015, in-situ remediation had removed over 44 percent of the mass in the target treatment area. Within the IRZs, concentrations are rapidly reduced within the timeframe of weeks to a few months. Down-gradient of the IRZs, treatment has been observed at distances over 915 meters (3,000 feet). This presentation will focus on the design, operation, adaptive management and results of this effort. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater monitoring report streamlining techniques - 15305

Compliance with national and state environmental regulations (e.g. RCRA and CERCLA [SuperFund] requires Savannah River Site (SRS) to extensively collect and report groundwater monitoring data, with potential fines for missed reporting deadlines. Large reports, which may contain dozens to hundreds of monitoring stations, are especially challenging to present data in a way that is quick and easy to interpret. Initially analyzing hundreds to thousands of records of data to be summarized in the report can be daunting, and producing maps can be extremely time consuming. Several utilities have been developed at SRS to facilitate production of the regulatory reports which include data tables, charts, maps, and cross-sections. Components of each report are generated in accordance with complex sets of regulatory requirements specific to each site monitored. SRS developed a relational database to incorporate the detailed reporting rules with the groundwater data, and created a set of automation tools to interface with the information and generate the report components. Maps produced with ArcGIS use a technique that can be repeatedly used to display data very quickly and in a consistent form. Cross-sections developed with RockWorks provide a more technical and geological analysis and representation of well and boring data, while allowing for automated data placement. These process improvements have streamlined the repetitive job of creating data tables, charts, maps, and cross-sections. It has also enhanced report quality and consistency by centralizing the information, and has reduced manpower and production time through automated efficiencies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study on Characterization of Colloidal Silica Grout for Rock Excavation Under Saline Groundwater - 19332

A rock excavation grouting technology has been recently studied as significant technology for reducing the ingress of water into the deep repository. However, it has not been studied for applying to the coastal region, where it is discussed to be a more suitable region for the geological disposal in Japan. The latest material called colloidal silica grout (CSG) is good for sealing narrow fractures but is known to be sensitive to the salinity of groundwater because of its gelling property with salt accelerator. Although the gelling of CSG can be controlled by adding an acidic pH adjuster, the methodology for delivering the appropriate grout is not well established for such conditions of saline groundwater. Therefore, this research project was established to enhance the existing rock grouting technology for deep repositories. Initially, a grouting workshop was held with Nordic authorities in order to understand the state of the art and identify the most significant challenges to developing a generic mixing method for injecting CSG under seawater. Based on laboratory tests, we developed a feasible mixing methodology that prevents the rapid reaction with the salty water, which shows that CSG is not negatively impacted by salty mixing water or submerged by saline water. Combining the latest grouting techniques from Japan and the Nordic countries creates an optimal grouting methodology for use under seawater. Using this hybrid approach, the CSG can find wide-scale use as an agent for grouting narrow rock fractures filled with saline or fossil water in order to decrease the ingress of water in the disposal facilities. The reduction of the water ingress will enhance the safety of the repository, reduce water discharge, and diminish the long-term cost of water treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Modeling of Contaminant Fate and Transport in Soil and Groundwater from F-Canyon and the Central Laboratory Facility

F-Canyon (221-F) was constructed in the early 1950's and, together with FB Line, began operations in 1954 as the main processing facilities in FArea of SRS. The primary operations conducted in F-Canyon and FB Line included the separation and recovery of Pu-239 and U-238 from irradiated materials and the stabilization of plutonium residues. The F/H Laboratory Complex consists of buildings 772-F, 772-1F, and 772-4F which began operations in 1954, 1987, and 1993, respectively. The primary mission of the F/H Laboratory Complex for the last 45 years has been to support the chemical separations processing activities at Building 221-F and H-Canyon. The objective of this study is to determine the radionuclide and hazardous material holdup in F-Canyon and its support facilities, and to evaluate In-Situ Disposal (ISD) alternatives for deactivation and decommissioning (D and D) of these facilities to ensure groundwater protection and environmental compliance with the South Carolina Department of Health and Environmental Services (SCDHES) and the United States Environmental Protection Agency (USEPA). GoldSim is a dynamic probabilistic simulation software that allows modeling of chemical mass transport through engineered and environmental systems For this study, it will model the potential future release of radiological contamination through the vadose zone, Upper Three Runs (UTR) Aquifer and the Upper Three Runs Creek. Using a GoldSim model developed for building 235-F D and D, contaminant inventories as well as building geometry were updated to create the basis of the new F-Canyon model. The inventories from F-Canyon, FB Line, and the 800 Series Tanks (Tanks 804, 808, and 809) as well as F/H labs (including buildings 772-F, 772-1F, and 772- 4F) were used to make a total of four sources. The concentrations of total uranium and beta-gamma are within compliance for the study, while radium and alpha concentrations exceed their MCL's around 30,000 years and total effective water dose exceeds its MCL around 1,200 years. This suggests that some level of action will be needed to meet SCDHES and USEPA requirements. This evaluation was conducted only for the no-action alternative. Consideration and modeling of other alternatives will be required in the future to determine the best ISD alternative for D and D of F-Canyon and F/H labs with regard to groundwater protection, worker safety, and financial cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probabilistic Groundwater Modeling of the RDX Plume at Los Alamos National Laboratory to Support Risk Assessment - 20359

A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEPARTMENT OF ENERGY SOIL AND GROUNDWATER SCIENCE AND TECHNOLOGY NEEDS, PLANS AND INITIATIVES

This paper presents the process used by the Department of Energy (DOE) Environmental Management (EM) Program to collect and prioritize DOE soil and groundwater site science and technology needs, develop and document strategic plans within the EM Engineering and Technology Roadmap, and establish specific program and project initiatives for inclusion in the EM Multi-Year Program Plan. The paper also presents brief summaries of the goals and objectives for the established soil and groundwater initiatives.

54 ENVIRONMENTAL SCIENCES↗

The Underground Test Area Project of the Nevada Test Site: Building Confidence in Groundwater Flow and Transport Models at Pahute Mesa Through Focused Characterization Studies

Pahute Mesa at the Nevada Test Site contains about 8.0E+07 curies of radioactivity caused by underground nuclear testing. The Underground Test Area Subproject has entered Phase II of data acquisition, analysis, and modeling to determine the risk to receptors from radioactivity in the groundwater, establish a groundwater monitoring network, and provide regulatory closure. Evaluation of radionuclide contamination at Pahute Mesa is particularly difficult due to the complex stratigraphy and structure caused by multiple calderas in the Southwestern Nevada Volcanic Field and overprinting of Basin and Range faulting. Included in overall Phase II goals is the need to reduce the uncertainty and improve confidence in modeling results. New characterization efforts are underway, and results from the first year of a three-year well drilling plan are presented.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

In situ groundwater bioremediation

In situ groundwater bioremediation of hydrocarbons has been used for more than 40 years. Most strategies involve biostimulation; however, recently bioaugmentation have been used for dehalorespiration. Aquifer and contaminant profiles are critical to determining the feasibility and strategy for in situ groundwater bioremediation. Hydraulic conductivity and redox conditions, including concentrations of terminal electron acceptors are critical to determine the feasibility and strategy for potential bioremediation applications. Conceptual models followed by characterization and subsequent numerical models are critical for efficient and cost effective bioremediation. Critical research needs in this area include better modeling and integration of remediation strategies with natural attenuation.

54 ENVIRONMENTAL SCIENCES↗

SUBSURFACE MOBILE PLUTONIUM SPECIATION: SAMPLING ARTIFACTS FOR GROUNDWATER COLLOIDS

A recent review found several conflicting conclusions regarding colloid-facilitated transport of radionuclides in groundwater and noted that colloids can both facilitate and retard transport. Given these contrasting conclusions and the profound implications even trace concentrations of plutonium (Pu) have on the calculated risk posed to human health, it is important that the methodology used to sample groundwater colloids be free of artifacts. The objective of this study was: (1) to conduct a field study and measure Pu speciation, ({sup 239}Pu and {sup 240}Pu for reduced-Pu{sub aq}, oxidized-Pu{sub aq}, reduced-Pu{sub colloid}, and oxidized-Pu{sub colloid}), in a Savannah River Site (SRS) aquifer along a pH gradient in F-Area, (2) to determine the impact of pumping rate on Pu concentration, Pu speciation, and Pu isotopic ratios, (3) determine the impact of delayed sample processing (as opposed to processing directly from the well).

54 ENVIRONMENTAL SCIENCES↗

Utah FORGE Groundwater Levels: Updated 2021

Contains Utah FORGE ground water data for wells WOW2 and WOW3. The data was updated on October 5th, 2021 and contains legacy data. Groundwater data includes the level, offset, date, and time for each measurement. Temperature, drift, water elevation and other parameters are recorded. Figures in the data include a water elevation over time plot. Legacy data ranges from year 1976 to 2019 and updated data ranges from year 2019 to 2021.

15 GEOTHERMAL ENERGY↗

Groundwater table elevation and temperature from 2015 to 2024 at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells with Location ID's ER-DOW (alias DO1West), ER-DOE (alias DO2East), ER-MBA1 (alias M1Bend1), ER-MBA2 (alias M1Bend2), ER-UPW (alias UP1West), ER-UPM (alias UP2), ER-UPE (alias UP3East). Another dataset contains the data from wells with Location ID's ER-CPA1 to ER-CPA6. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 8 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗

Groundwater table elevation and temperature from 2015 to 2024 across Meander C at the Lower Montane site in the East River Watershed, Colorado.

This groundwater level elevation and temperature data package is aimed at improving the predictive understanding of hydro-biogeochemical processes at the lower montane site in the East River Watershed, Colorado. The dataset is obtained using pressure transducers placed in shallow wells in the floodplain. This dataset contains data from wells ER-CPA1 to ER-CPA6. Another dataset contains the data from wells at nearby Locations. Each file contains the water level elevation and the water temperature. Water level elevation has been obtained using the barometric pressure from the pressure transducer (Hobos sensor) in the well, barometric pressure from a sensor in air located at the same site (lower montane), depth from top-of-casing (TOC) to sensor measurement point, and TOC elevation. Data have been checked with a few measurements of water table depths. A real-time kinematic (RTK) global positioning system (GPS) has been used to survey the TOC (data in file Well_Location.csv). The water level elevation is given in UTM13N Geoid2012AB. While depth to water level is not present in the data files, it can be easily calculated with the TOC and distance to ground provided in the GPS coordinate file. The dataset quality is discussed in Collection/Analysis section of the methods. Time-series of measurements were initially added to the archive for the period 2015 to 2019, and later updated with time-series until 2024 (end of data collection). The dataset contains 7 *.csv data files, and 3 *.csv metadata files. Feel free to contact the author with any questions or collaboration interests. The publication year was updated from "2020" to "2025" to reflect the revised version of this dataset.

54 ENVIRONMENTAL SCIENCES↗