Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRID MODELING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Large-Eddy Simulation of Axisymmetric Compression Corner Flow

The Wall-Modeled Large Eddy Simulation (WMLES) approach is used to study the interaction of a shock wave with a high Reynolds number turbulent boundary layer. Since the near wall region is modeled, high Reynolds number turbulent flows can be simulated at a moderate computational cost. The case considered is that of an axisymmetric Mach 2.85 turbulent boundary layer over a 30 compression corner. The Reynolds number of the boundary layer upstream of the interaction based on momentum thickness (Re theta = u sub infinity theta/v sub infinity) is ~12,000. The geometry and flow conditions match the experiments of Dunagan et al. (NASA TM 88227, 1986). The simulations were performed using equilibrium and non-equilibrium wall models. The agreement with experiment is encouraging for the finest grid with respect to the separation bubble length, unsteady shock structure and wall pressure distribution. Sensitivity ofWMLES results to grid, wall model, and blockage effects in the tunnel are reported.

Iyer, Prahladh S.↗

Practical challenges of model predictive control (MPC) for grid interactive small and medium commercial buildings

To the urgent call for mitigating climate change, substantial initiatives have been undertaken to deploy grid-interactive heating, ventilation, and air-conditioning (HVAC) controls, such as model predictive control (MPC) for buildings. These efforts typically aim to curtail peak energy demand, shift load and enhance overall energy efficiency. With the recent development of low-cost MPC technologies that don’t require extensive instrumentation or manual modeling, small and medium commercial buildings (SMCBs), which rarely utilize advanced HVAC control systems, have become candidates for grid-interactive efficient buildings (GEBs). However, despite the potential benefits and maturity of the technology itself, several practical challenges remain in real-world implementation. In this paper, we share the practical challenges that we have encountered in implementing and testing three types of MPC solutions (ON/OFF unit, dualfuel, and VRF systems) on multiple SMCB sites. We describe the MPC deployment process and discuss the lessons learned. The site selection, eligibility, and retrofit availability (e.g., utility price structure, thermostat communications, etc.) are the main discussion points at the beginning of the project. Also, the modeling automation and the best practices for interacting with endusers and handling erroneous situations are presented for successful operations.

woo Ham, Sang↗

Data Request for the Distribution Grid Atlas

Model-based, distribution powerflow analysis is a foundational component of system planning and grid modernization efforts, but data security is an impediment to collaboration among utility engineers, researchers, developers, community members, and other stakeholders. Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) are partnering to develop the new Distribution Grid Atlas - a publicly available catalog of realistic, geographically relevant, representative distribution feeder models without sensitive geographic information, customer data, or disclosure of utility models. We are looking for utilities to share data for the Distribution Grid Atlas.

distribution↗

Development of multi-hierarchy simulation model with non-uniform space grids for collisionless driven reconnection

A multi-hierarchy simulation model aimed at magnetic reconnection studies has been developed, in which macroscopic and microscopic physics are solved self-consistently and simultaneously. In this work, the previous multi-hierarchy model by these authors is extended to a more realistic one with non-uniform space grids. Based on the domain decomposition method, the multi-hierarchy model consists of three parts: a magnetohydrodynamics algorithm to express the macroscopic global dynamics, a particle-in-cell algorithm to describe the microscopic kinetic physics, and an interface algorithm to interlock macro and micro hierarchies. For its verification, plasma flow injection is simulated in this multi-hierarchy model and it is confirmed that the interlocking method can describe the correct physics. Furthermore, this model is applied to collisionless driven reconnection in an open system. Magnetic reconnection is found to occur in a micro hierarchy by injecting plasma from a macro hierarchy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scalar excursions in large-eddy simulations

Here, the range of values of scalar fields in turbulent flows is bounded by their boundary values, for passive scalars, and by a combination of boundary values, reaction rates, phase changes, etc., for active scalars. The current investigation focuses on the local conservation of passive scalar concentration fields and the ability of the large-eddy simulation (LES) method to observe the boundedness of passive scalar concentrations. In practice, as a result of numerical artifacts, this fundamental constraint is often violated with scalars exhibiting unphysical excursions. The present study characterizes passive-scalar excursions in LES of a shear flow and examines methods for diagnosis and assesment of the problem. The analysis of scalar-excursion statistics provides support of the main hypothesis of the current study that unphysical scalar excursions in LES result from dispersive errors of the convection-term discretization where the subgrid-scale model (SGS) provides insufficient dissipation to produce a sufficiently smooth scalar field. In the LES runs three parameters are varied: the discretization of the convection terms, the SGS model, and grid resolution. Unphysical scalar excursions decrease as the order of accuracy of non-dissipative schemes is increased, but the improvement rate decreases with increasing order of accuracy. Two SGS models are examined, the stretched-vortex and a constant-coefficient Smagorinsky. Scalar excursions strongly depend on the SGS model. The excursions are significantly reduced when the characteristic SGS scale is set to double the grid spacing in runs with the stretched-vortex model. The maximum excursion and volume fraction of excursions outside boundary values show opposite trends with respect to resolution. The maximum unphysical excursions increase as resolution increases, whereas the volume fraction decreases. The reason for the increase in the maximum excursion is statistical and traceable to the number of grid points (sample size) which increases with resolution. In contrast, the volume fraction of unphysical excursions decreases with resolution because the SGS models explored perform better at higher grid resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Characterization and Vibration Testing of 30-cm Carbon-Carbon Ion Optics

Carbon-based ion optics have the potential to significantly increase the operable life and power ranges of ion thrusters because of reduced erosion rates compared to molybdenum optics. The development of 15-cm and larger diameter grids has encountered many problems, however, not the least of which is the ability to pass vibration testing. JPL has recently developed a new generation of 30-cm carbon-carbon ion optics in order to address these problems and demonstrate the viability of the technology. Perveance, electron backstreaming, and screen grid transparency data are presented for two sets of optics. Vibration testing was successfully performed on two different sets of ion optics with no damage and the results of those tests are compared to models of grid vibrational behavior. It will be shown that the vibration model is a conservative predictor of grid response and can accurately describe test results. There was no change in grid alignment as a result of vibration testing and a slight improvement, if any change at all, in optics performance.

grids↗

Simulation of the Summer Monsoon Rainfall over East Asia using the NCEP GFS Cumulus Parameterization at Different Horizontal Resolutions

The most recent version of Simplified Arakawa-Schubert (SAS) cumulus scheme in National Center for Environmental Prediction (NCEP) Global Forecast System (GFS) (GFS SAS) has been implemented into the Weather and Research Forecasting (WRF) model with a modification of triggering condition and convective mass flux to become depending on model’s horizontal grid spacing. East Asian Summer Monsoon of 2006 from June to August is selected to evaluate the performance of the modified GFS SAS scheme. Simulated monsoon rainfall with the modified GFS SAS scheme shows better agreement with observation compared to the original GFS SAS scheme. The original GFS SAS scheme simulates the similar ratio of subgrid-scale precipitation, which is calculated from a cumulus scheme, against total precipitation regardless of model’s horizontal grid spacing. This is counter-intuitive because the portion of resolved clouds in a grid box should be increased as the model grid spacing decreases. This counter-intuitive behavior of the original GFS SAS scheme is alleviated by the modified GFS SAS scheme. Further, three different cumulus schemes (Grell and Freitas, Kain and Fritsch, and Betts-Miller-Janjic) are chosen to investigate the role of a horizontal resolution on simulated monsoon rainfall. The performance of high-resolution modeling is not always enhanced as the spatial resolution becomes higher. Even though improvement of probability density function of rain rate and long wave fluxes by the higher-resolution simulation is robust regardless of a choice of cumulus parameterization scheme, the overall skill score of surface rainfall is not monotonically increasing with spatial resolution.

CPS↗

A line-blanketed model stellar atmosphere of Sirius

The method of artificial absorption edges is applied to a grid of model atmospheres to include the effects of hydrogen and metal line blanketing on the atmospheric structure. A best-fit model of Sirius is obtained which is free of the discrepancies inherent in unblanketed or partially blanketed models. All major spectral features calculated from the model agree with the corresponding observed features to within the observational uncertainty. Some additional properties of the models are discussed.

Fowler, J. W.↗

Impact of Glen Canyon Generation Loss

Colorado River Basin hydropower generation has faced challenges due to droughts and ecological and social water requirements. Specifically, Glen Canyon hydropower generation fluctuates substantially with recent extreme weather trends. Further, the western grid evolves with higher wind and solar share, and Glen Canyon hydropower's contribution to grid flexibility services is essential. The Western Area Power Administration (WAPA) markets and schedules electricity production at GCD, and the loss of this power could have significant financial consequences for the WAPA Colorado River Storage Project's (CRSP) Office because it may need to purchase relatively large amounts of energy to serve its firm electrical obligations. In addition, GCD provides grid reliability services for the WAPA Colorado-Missouri (WACM) balancing authority (BA). Both WAPA and DOE's Water & Power Technology Office (WPTO) are interested in researching how these drier hydrological conditions will impact federal electrical energy production, the Western Electricity Coordinating Council (WECC) power grid, and the value of hydropower in the face of lower production. We study multiple hydrologic and power grid scenarios to understand the grid impacts of the loss of Glen Canyon generation. The study uses a production cost model, water resources planning models, water-centric grid models, and various data analytic techniques. The study progress presentation discusses the selection of probable CRSP' hydropower scenarios and power grid scenarios to understand the impacts of Glen Canyon generation, which includes technologies that compensate the Glen Canyon energy and ancillary services contributions, transmission availability, and energy local marginal prices at interested grid locations of WAPA operation.

droughts↗

Enhancing Grid Resilience with HIVE: Decentralized V2G Coordination for Black Starts

This paper proposes the HIVE (Harmonized Integration of Vehicle Energy for Grid Support) model, a novel game-theoretic framework for decentralized coordination of electrified vehicles to enable black start and load restoration during grid outages. In the absence of a central controller, HIVE employs a cooperative game to model vehicle interactions, allowing autonomous decision-making while admitting to a Nash equilibrium for grid restoration. The framework addresses the heterogeneity of vehicles and their operational constraints, selecting a lead vehicle for grid-forming and coordinating grid-following vehicles to support prioritized loads. Applied to a hospital blackout scenario, HIVE demonstrates robust performance in forming an islanded microgrid and sustaining critical loads under varying vehicle availability, state of charge, and power constraints. Simulation results highlight the model’s effectiveness in ensuring decentralized coordination of energy allocation and prioritizing loads, offering a scalable solution for resilient grid operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

REEVALUATING THE MASS-RADIUS RELATION FOR LOW-MASS, MAIN-SEQUENCE STARS

We examine the agreement between the observed and theoretical low-mass (<0.8 M{sub Sun }) stellar main-sequence mass-radius relationship by comparing detached eclipsing binary (DEB) data with a new, large grid of stellar evolution models. The new grid allows for a realistic variation in the age and metallicity of the DEB population, characteristic of the local galactic neighborhood. Overall, our models do a reasonable job of reproducing the observational data. A large majority of the models match the observed stellar radii to within 4%, with a mean absolute error of 2.3%. These results represent a factor of two improvement compared to previous examinations of the low-mass mass-radius relationship. The improved agreement between models and observations brings the radius deviations within the limits imposed by potential starspot-related uncertainties for 92% of the stars in our DEB sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling Electrolysis-based H2 Production for Grid Service Assessment

Hydrogen is a promising clean and renewable source of energy. Its high energy density offers a unique and effective means to store energy. The integration of hydrogen production devices with the power grid could lead to a cleaner and more reliable grid operation at reasonable costs. In this work, the capability of Proton Exchange Membrane (PEM) electrolyzers to perform grid services is assessed using a battery equivalent model approach. The Battery Equivalent Model (BEM) has been developed to represent the physics and operation of a fleet of PEM electrolyzers. The BEM model has been designed to be modular and readily incorporated into grid planning studies. This application of PEM electrolyzers can be integrated with other power generation and consumption devices, aggregating capabilities of each device to enhance the ability of the integrated system to provide grid services and improves grid stability. The developed model is evaluated using ancillary support services including peak management, frequency regulation, voltage regulation, artificial inertia, spinning reserve, and wholesale market price response using a representative price and power system profiles. The BEM model has also been evaluated to provide frequency regulation service that conforms to the IEEE 1547-2018 standard. Metrics such as energy efficiency, charging efficiency, hydrogen production rate, and service efficacy have been incorporated into the model to quantify the performance of the fleet while responding to grid services. Results show the electrolyzer fleet's effectiveness in quickly adjusting its real power consumption based on grid service requests. The energy efficiency of the fleet is maintained relatively high – in the range of 78% and 90% during the service operation. These results demonstrate the ability of PEM electrolyzers to effectively provide fast dispatch capability through storing off-peak hour energy while regulating power consumption during peak hours. The BEM model can assist in quantifying the stability and variability impacts from integration of PEM electrolyzers with intermittent renewable resources in grid integration studies.

08 HYDROGEN↗

Checkerboard Patterns in E3SMv2 and E3SM-MMFv2

An unphysical checkerboard pattern is identified in E3SMv2 and E3SM-MMF that is detectable across a wide range of timescales, from instantaneous snapshots to multi-year averages. A detection method is developed to quantify characteristics of the checkerboard signal by cataloguing all possible configurations of the eight adjacent neighbors for each cell on the model's cubed sphere grid using daily mean data. The checkerboard pattern is only found in cloud-related quantities, such as precipitation and liquid water path. Instances of pure and partial checkerboard are found to occur more often in E3SMv2 and E3SM-MMF when compared to satellite data regridded to the model grid. Continuous periods of partial checkerboard state are found to be more persistent in both models compared to satellite data, with E3SM-MMF exhibiting more persistence than E3SMv2. The checkerboard signal in E3SMv2 is found to be a direct consequence of the recently added deep convective trigger condition based on dynamically generated CAPE (DCAPE). In E3SM-MMF the checkerboard signal is found to be associated with the “trapping” of cloud-scale fluctuations within the embedded cloud-resolving model. Solutions to remedy this issue are discussed.

E3SMv2↗

Technology Pathways Could Help Drive the U.S. West Coast Grid's Exposure to Hydrometeorological Uncertainty

Abstract Previous studies investigating deep decarbonization of bulk electric power systems and wholesale electricity markets have not sufficiently explored how future grid pathways could affect the grid's vulnerability to hydrometeorological uncertainty on multiple timescales. Here, we employ a grid operations model and a large synthetic weather ensemble to “stress test” a range of future grid pathways for the U.S. West Coast developed by ReEDS, a well‐known capacity planning model. Our results show that gradual changes in the underlying capacity mix from 2020 to 2050 can cause significant “re‐ranking” of weather years in terms of annual wholesale electricity prices (with “good” years becoming bad, and vice versa). Nonetheless, we find the highest and lowest ranking price years in terms of average electricity price remain mostly tied to extremes in hydropower availability (streamflow) and load (summer temperatures), with the strongest sensitivities related to drought. Seasonal dynamics seen today involving spring snowmelt and hot, dry summers remain well‐defined out to 2050. In California, future supply shortfalls in our model are concentrated in the evening and occur mostly during periods of high temperature anomalies in late summer months and in late winter; in the Pacific Northwest, supply shortfalls are much more strongly tied to negative streamflow anomalies. Under our more robust sampling of stationary hydrometeorological uncertainty, we also find that the ratio of dis‐patchable thermal (i.e., natural gas) capacity to wind and solar required to ensure grid reliability can differ significantly from values reported by ReEDS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Resolution and Parameterized Convection on the Diurnal Cycle of Precipitation in a Global Nonhydrostatic Model

A series of 40-day non-hydrostatic global simulations was run with the NASA Goddard Earth Observing System (GEOS) model with horizontal grid spacing ranging from 50 km to 3.5 km. Here we evaluate the diurnal cycle of precipitation and organized convection as a function of resolution. For validation we use the TRMM 3B42 and IMERG precipitation products and 4 km Merged Infrared brightness temperature, focusing on three regions: the contiguous United States (CONUS), the Maritime Continent, and Amazonia. We find that higher resolution has mixed impacts on diurnal phase. Regions dominated by non-local propagating convection show the greatest improvement, with better representation of organized convective systems. Precipitation in regions dominated by local thermodynamic forcing tends to peak too early at high resolution. Diurnal amplitudes in all regions develop unrealistic small-scale variability at high resolution, while amplitudes tend to be underestimated at low resolution. The GEOS model uses the Grell-Freitas scale-aware convection scheme, which smoothly reduces parameterized deep convection with increasing resolution. We find that some parameterized convection is beneficial for the diurnal amplitude and phase even with a 3.5 km model grid, but only when throttled with the scale-aware approach. An additional 3.5 km experiment employing the GFDL microphysics scheme and higher vertical resolution shows further improvement in propagating convection, but an earlier rainfall peak in locally forced regions.

Nathan P. Arnold↗