Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Anisotropic Optical-Response of Eu-doped Yttrium Orthosilicate

Eu-doped yttrium orthosilicate (Eu(3+) : Y2SiO5) had been a subject being investigated for coherent time-domain optical memory and information processing applications since its ultraslow optical dephasing was discovered several years ago. In this crystal the weakly allowed (7)F0 - (5)D0 transition of europium ions exhibits a sufficient long dephasing time and no spectral difli.usion on a time scale of several hours at low temperature, thus an information pattern or data can be stored as a population grating in the ground state hyperfine levels. On the other hand, the study on photon-echo relaxation shows that the dephasing time T2 of Eu (3+) and other rare-earth ions doped YAG, YAlO3 strongly depends on the intensity of the excitation pulses. In Eu (3+) :YAlO3, an exponential decay of photon-echo with T2 = 53 microseconds if the excitation pulses are weak (5 vJ/pulse) was observed. However, when the excitation pulses are strong (80 pJ/pulse) they observed a much shortened T2 with a highly nonexponential decay pattern. The conclusion they derived is that the intensity-dependent dephasing rate effects are quite general, and it depends on how much the excitation intensity varies. In this paper we use transient grating formation technique showing that a temporal lattice distortion may only occur along crystal c axis, caused by EU (3+) excitation. At high excitation level the produced exciton in conduction band may also couple to the dynamical lattice relaxation process, giving rise to an apparently much shortened dephasing time.

Liu, Huimin↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Apparatus For Linewidth Reduction in Distributed Feedback or Distributed Bragg Reflector Semiconductor Lasers Using Vertical Emission

The linewidth of a distributed feedback semiconductor laser or a distributed Bragg reflector laser having one or more second order gratings is reduced by using an external cavity to couple the vertical emission back into the laser. This method and device prevent disturbance of the main laser beam, provide unobstructed access to laser emission for the formation of the external cavity, and do not require a very narrow heat sink. Any distributed Bragg reflector semiconductor laser or distributed feedback semiconductor laser that can produce a vertical emission through the epitaxial material and through a window in the top metallization can be used. The external cavity can be formed with an optical fiber or with a lens and a mirror or grating.

Cook, Anthony L.↗

Chandra and the Emission Line Project

Calibration data obtained for the Chandra High Energy Transmission Grating and the Low Energy Transmission Grating Spectrometers are allowing us to test plasma spectral models against bright coronal sources with a range of electron temperatures. The three Emission Line Project targets - Capella, Procyon, and HR 1099 - are bright, well-studied X-ray and EUV emitters. The goals of the Emission Line Project are to determine and verify accurate and robust diagnostics; to identify and prioritize problems in fundamental spectroscopy; and to accelerate the improvement of the atomic database needed for modeling.

Brickhouse, N. S.↗

The Barberplaid Illusion

Mulligan showed that the perceived direction of a moving grating can be biased by the shape of the Gaussian window in which it is viewed. We sought to determine if a 2-D pattern with an unambiguous velocity would also show such biases. Observers viewed a drifting plaid (sum of two orthogonal 2.5 c/d sinusoidal gratings of 12% contrast, each with a TF of 4 Hz.) whose contrast was modulated spatially by a stationary, asymmetric 2-D Gaussian window (i.e. unequal standard deviations in the principal directions). The direction of plaid motion with respect to the orientation of the window's major axis (Delta Theta) was varied while all other motion parameters were held fixed. Observers reported the perceived plaid direction of motion by adjusting the orientation of a pointer. All five observers showed systematic biases in perceived plaid direction that depended on Delta Theta and the aspect ratio of the Gaussian window (lambda). For circular Gaussian windows Lambda = 1), plaid direction was veridically perceived. However, biases of up to 10 deg. were found for lambda = 2 and Delta Theta = 30 deg. These data present a challenge to models of motion perception which do not explicitly consider the integration of information across the visual field.

Beutter, B. R.↗

Directions of Moving Plaids is Biased by Asymmetric Viewing Windows

Directionally selective V1 neurons are tuned to particular spatio-temporal frequencies and respond to local 1-D edge motion. At least some MT neurons however appear to respond to the actual velocity of moving 2D patterns. To better understand how the 1D local motion information available from VI is integrated to derive a 2D velocity signal we investigated human perception of moving plaids, 2-D patterns composed of the sum of two 1-D sinusoidal gratings of different orientations. We measured the effect of the shape of the viewing window on the perceived direction of plaid motion. The plaids were spatially windowed by 2-D Gaussians with unequal standard deviations (sigma 1, sigma 2). Four observers indicated perceived direction by adjusting a pointer. Direction errors were measured as a function of the difference between window orientation and true plaid direction (DELTA THETA) for several grating spatial frequencies (SF = 0.3, 0.6, 1.2 c/d) and window aspect ratios (AR = sigma 1/sigma 2 = 1, 1.4, 2, 4). Observers showed systematic errors in perceived direction (approx. 15 for AR = 4 and SF = 0.6 c/d) that peaked at DELTA THETA approx. 40. The errors increased for increasing aspect ratio and decreased for increasing spatial frequencies (or number of cycles). These results show that despite the unambiguous motion of the plaids, under these conditions human misperceive the motion. These data constrain models of motion integration from V1 to MT and, in particular, are inconsistent with algorithms that use either the Intersection of Constraints rule or cross correlation to compute the perceived direction of motion.

Beutter, B. R.↗

Direction of Moving Plaids is Biased by Asymmetric Viewing Windows

Directionally selective V1 neurons are tuned to particular spatiotemporal frequencies and respond to local 1-D edge motion. At least some MT neurons however appear to respond to the actual velocity of moving 2D patterns (Movshon et al., EBR, 11:117, 1986). To better understand how the 1D local motion information available from V1 is integrated to derive a 2D velocity signal we investigated human perception of moving plaids, 2-D patterns composed of the sum of two 1-D sinusoidal gratings of different orientations. We measured the effect of the shape of the viewing window on the perceived direction of plaid motion. The plaids were spatially windowed by 2-D Gaussians with unequal standard deviations (sigma l, sigma 2). Four observers indicated perceived direction by adjusting a pointer. Direction errors were measured as a function of the difference between window orientation and true plaid direction (delta theta) for several grating spatial frequencies (SF = 0.3, 0.6, 1.2 c/d) and window aspect ratios (AR = sigma 1/sigma 2 = 1, 1.4, 2,4). Observers showed systematic errors in perceived direction (approx. 15 degrees for R = 4 and SF = 0.6 c/d) that peaked at delta theta approximately 40 degrees. The errors increased for increasing aspect ratio and decreased for increasing spatial frequencies (or number of cycles). These results show that despite the unambiguous motion of the plaids, within asymmetric windows, human can systematically misperceive plaid direction. These data constrain models of motion integration within extrastriate cortex and, in particular, are inconsistent with algorithms that use either the Intersection of Constraints rule or cross correlation to compute velocity.

Beutter, Brent Robert↗

4482 Element Multispectral Hybrid PV/PC HgCdTe IRFPA for High Resolution Coverage of 3.7 - 15.4 Micrometers for the AIRS Instrument

The Atmospheric Infrared Sounder (AIRS) is a key facility instrument in the NASA Earth Observing System (EOS) program, being implemented to obtain comprehensive long-term measurements of earth processes affecting global change. The instrument performs passive IR remote sensing using a high resolution grating spectrometer with a wide spectral coverage (3.7 - 15.4 m) directing radiation onto a hybrid HgCdTe IRFPA operating at 58K in a vacuum package cooled to 155K. The hybrid HgCdTe FPA consists of twelve modules, 10 with multiplexed photovoltaic detectors and two with individually leaded out photoconductive detectors. The complex FPA has a large optical footprint, 53 mm x 66 mm, and receives energy dispersed from the grating through a precision filter assembly containing 17 narrow band filters. The backside illuminated PV detector arrays are fabricated from P-on-n double layer LPE grown heterojunction detectors in a bilinear format of 50 m x 100 m detectors, with from 232 to 420 detectors per module. For the MWIR bands four PV modules cover the 3.7 m to 8.22 m region. Low detector capacitance and low noise preamplifiers in the ROIC are key to achieving high sensitivities in these bands. Uniform quantum efficiencies and detectivities exceeding 3E13 cm-rtHz/W have been achieved. The LWIR region is covered by six PV modules spanning 8.8 m to 13.75 m. High detector resistance and very low ROIC preamplifier input noise are key to achieving high sensitivity. A detectivity exceeding 2E11 cm-rtHz/W has been achieved at the longest wavelength. Two additional PC modules cover the longest spectral bands out to 15.4 m. This high performance multispectral focal plane has been built and integrated with the dewar assembly, and is currently being integrated with the complete AIRS sensor.

Rutter, James↗

Calibration of a Spatial-Temporal Discrimination Model from Forward, Simultaneous, and Backward Masking

We have been developing a simplified spatial-temporal discrimination model similar to our simplified spatial model in that masking is assumed to be a function of the local visible contrast energy. The overall spatial-temporal sensitivity of the model is calibrated to predict the detectability of targets on a uniform background. To calibrate the spatial-temporal integration functions that define local visible contrast energy, spatial-temporal masking data are required. Observer thresholds were measured (2IFC) for the detection of a 12 msec target stimulus in the presence of a 700 msec mask. Targets were 1, 3 or 9 c/deg sine wave gratings. Masks were either one of these gratings or two of them combined. The target was presented in 17 temporal positions with respect to the mask, including positions before, during and after the mask. Peak masking was found near mask onset and offset for 1 and 3 c/deg targets, while masking effects were more nearly uniform during the mask for the 9 c/deg target. As in the purely spatial case, the simplified model can not predict all the details of masking as a function of masking component spatial frequencies, but overall the prediction errors are small.

Ahumada, Albert J.↗

Long Holographic Lifetimes in Bacteriorhodopsin Films

The D85N genetic variant of bacteriorhodopsin displays a nearly permanent lifetime of the photochromic P490 state. We present pump-probe measurements that demonstrate this behavior. However, experimental diffraction efficiency measurements made from holograms recorded in a hydrated D85N film show markedly different decay behavior, suggesting a molecular diffusion process occurring in the film. Holograms recorded with different grating frequencies display correspondingly different decay times which support this hypothesis. A thin D85N film was then fabricated which was chemically crosslinked, resulting in the elimination of diffusion of BR molecules within the polymer matrix. This film exhibits a grating lifetime on the order of weeks or more, thus allowing the long term holographic storage of information in a BR film.

Downie, John D.↗

Evaluation of Mechanical Modal Characteristics Using Optical Techniques

In this paper the sensitivity of embedded fiber optic sensors to changes in modal characteristics of plates is discussed. In order to determine the feasibility of embedded fiber Bragg gratings for the detection of modal shapes and modal frequencies, a comparison of holographically imaged modes and the detected dynamic strain from embedded fiber optic Bragg gratings is made. Time averaged optical holography is used for the detection of mechanical defects, or damage, in various aerospace components. The damage is detected by measuring an alteration in structural dynamics, which is visually apparent when using time-averaged holography. These shifts in the mode shapes, both in frequency of the resonance and spatial location of vibration nodes, are caused by changes in parameters that affect the structure's mechanical impedance, such as stiffness, mass and damping, resulting from cracks or holes. It is anticipated that embedded fiber optic sensor arrays may also be able to detect component damage by sensing these changes in modal characteristics. This work is designed to give an initial indication to the feasibility of damage detection through the monitoring of modal frequencies and mode shapes with fiber optic sensors.

Lekki, John↗

In Hot Pursuit of the Hidden Companion of Carinae: An X-Ray Determination of the Wind Parameters

We present X-ray spectral fits to a recently obtained Chandra grating spectrum of eta Carinae, one of the most massive and powerful stars in the Galaxy and which is strongly suspected to be a colliding wind binary system. Hydrodynamic models of colliding winds are used to generate synthetic X-ray spectra for a range of mass-loss rates and wind velocities. They are then fitted against newly acquired Chandra grating data. We find that due to the low velocity of the primary wind (approximately 500 km per sec), most of the observed X-ray emission appears to arise from the shocked wind of the companion star. We use the duration of the lightcurve minimum to fix the wind momentum ratio at eta = 0.2. We are then able to obtain a good fit to the data by varying the mass-loss rate of the companion and the terminal velocity of its wind. We find that M(sub 2) is approximately 10(exp -5) solar mass per yr and upsilon(sub infinity(sub 2)) is approximately 3000 km per sec. With observationally determined values of approximately 500- 700 km per sec for the velocity of the primary wind, our fit implies a primary mass-loss rate of M(sub 1) approximately 2.5 x 10(exp -4) solar mass per yr. This value is smaller than commonly inferred, although we note that a lower mass-loss rate can reduce some of the problems noted when a value as high as 10(exp -3) solar mass per yr is used. The wind parameters of the companion are indicative of a massive star which may or may not be evolved. The line strengths appear to show slightly sub-solar abundances, although this needs further confirmation. It also appears that the primary star is responsible for the nebula.

Pittard, J. M.↗

Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer

The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.

Haas, Michael R.↗

Optical Electronic Bragg Reflection Sensor System with Hydrodynamic Flow Applications

This project, as described in the following report, involved design and fabrication of fiber optic sensors for the detection and measurement of dynamic fluid density variations. These devices are created using UV (ultraviolet) ablation and generally modified transverse holographic fiber grating techniques. The resulting phase gratings created on or immediately underneath the flat portion of D-shaped optical waveguides are characterized as evanescent field sensing devices. The primary applications include the sensor portion of a real-time localized or distributed measurement system for hydrodynamic flow, fluid density measurements, and phase change phenomena. Several design modifications were implemented in an attempt to accomplish the tasks specified in our original proposal. In addition, we have established key collaborative relationships with numerous people and institutions.

Lyons, D. R.↗

Fe XXV and Fe XXVI Diagnostics of the Black Hole and Accretion Disk in Active Galaxies: Chandra Time-Resolved Spectroscopy of NGC 7314

We report the detection of Fe xxv and Fe XXVI Ka emission lines from a Chandra High Energy Grating Spectrometer (HETGS) observation of the narrow-line Seyfert 1 galaxy NGC 7314, made simultaneously with RXTE. The lines are redshifted (cz approximately 1500 kilometers per second) relative to the systemic velocity and unresolved by the gratings. We argue that the lines originate in a near face-on (less than 7 deg) disk having a radial line emissivity flatter than r(exp -2). Line emission from ionization states of Fe in the range approximately Fe I a up to Fe XXVI is observed. The ionization balance of Fe responds to continuum variations on timescales less than 12.5 ks, supporting an origin of the lines close to the X-ray source. We present additional, detailed diagnostics from this rich data set. These results identify NGC 7314 as a key source to study in the future if we are to pursue reverberation mapping of space-time near black-hole event horizons. This is because it is first necessary to understand the ionization structure of accretion disks and the relation between the X-ray continuum and Fe Ka line emission. However, we also describe how our results are suggestive of a means of measuring black-hole spin without a knowledge of the relation between the continuum and line emission. Finally, these data emphasize that one can study strong gravity with narrow (as opposed to very broad) disk lines. In fact narrow lines offer higher precision, given sufficient energy resolution.

Yaqoob, Tahir↗

Health Monitoring of RLV Airframe Structures

This final report is divided into three sections on health monitoring technologies: 1) Analysis of Optical Fiber Bragg Grating Sensor Data from Composite Wing Box Experiment; 2) Current Optical Fiber Bragg Grating Sensor Data Acquisition Design; and 3) Damages Identification of a Composite Plate by Prestack Reverse-Time Migration Technique. The report also includes an appendix, 'Group Velocities of Flexural Waves in a Composite Plate'.

Yuan, F. G.↗

An XMM Study of Low-Activity Coronal Stars of 1-2 Solar Masses

The objective of these observations was to take advantage of the large collecting area and sensitivity of the European Space Agency's XMM-Newton telescope to obtain X ray grating spectra of two relatively inactive late type stars, Beta Geminorun (K0 III) and the solar analog Beta Hydri (G2 IV). The observations were carried out as scheduled, achieving exposure times of 36 kiloseconds for Beta Gem and 27 kiloseconds for Beta Hyi. Unfortunately both stars were too faint to yield spectra with enough signal-to-noise for any further analysis. Consequently, there are no scientific results to report. The following pages illustrate the very weak X ray spectra that were obtained with the two RGS grating instruments for each star, first Beta Gem and then beta Hyi.

Simon, Theodore↗

Optical Design of the RAISE Sounding Rocket Instrument

The Rapid Acquisition Imaging Spectrograph Experiment (RAISE) is a recently selected sounding rocket program to investigate the dynamics and heating of the outer solar atmosphere on time scales as short as looms. Its optical design represents the first in a new class of two-reflection W / E W imaging spectrometers with Toroidal Varied-Line Space (TVLS) gratings. Due to the remarkable imaging properties of such gratings, RAISE will measure spectra simultaneously over four different wavelength bands (1205-1243 & 1524-1559 A in first order, 602.5-621.5 & 762.0-779.5 A in second), with an unprecedented combination of spatial, spectral, and temporal resolutions. These spectral regions include many bright, well-resolved lines covering the temperature range from the low chromosphere up to the 2 MK Fe XI1 corona. The RAISE optical design features an extremely fast beam (f/7.0) and a minimum number of reflections, which together allow enough throughput to provide high quality spectral data even at its very short exposure times. Moreover, by operating with high magnification (x4.25), the RAISE spectrometer can most effectively utilize the full length and width available in the sounding rocket payload. First launch of this exciting new instrument is scheduled for 2006 June 21.

Thomas, Roger J.↗