Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GPM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Efficient Mesofluidic Separation of Large Particles in nuclear slurries - 20408

Efficient and effective particle separation is essential to cleanup of many nuclear wastes. For example, particle separation may be used to accelerate settle-decant bottlenecks that limit the throughput necessary to achieve the U.S. Department of Energy waste cleanup mission in a timely manner. Particle separation may be used to protect downstream processing equipment from pulses of solids that may be encountered near (within a few feet of) liquid-solid interfaces during waste transfer operations, thereby preventing work stoppages. Effective particle separation may permit efficient sludge washing. These are only a few of the ways in which particle separation is important. Yet, efficient and effective particle separation in nuclear processing environments remains challenging. For example, settle-decant operations permit larger and heavier particles to settle, leaving smaller, lighter particles suspended. However, settle-decant operations are slow, convection currents may resuspend solids, hindered settling of multicomponent slurries remains incompletely understood, and predictive models for settling in graduated cylinders fail to match limited observations of settling in large waste tanks. Additionally, pumping operations can cause turbulent resuspension of particles when the pump intake is close to the settled solids layer. Filtration techniques that use membranes or partially permeable barriers retain larger particles, permitting smaller particles to permeate. However, filters, including dead-end filtration, are prone to clogging and caking, operate at elevated pressures due to minimal void volume, and increase in pressure during operations, which require more control systems. Therefore, the need for high throughput particle separation techniques that operate with modest pressure drops persists. A novel mesofluidic separator presents the opportunity to effectively and efficiently accelerate the waste cleanup mission. The separator separates large particles from process streams across a broad range of particle sizes and has no moving parts or media to replace, regenerate, or clean. This separator design has an unusually large void volume, permitting operation at much higher flow rates (and lower pressures) than traditional filtration (e.g., dead-end filtration). Industrial-scale flow rates have been demonstrated. In performance testing, mesofluidic separators operate at might flow rates (>90 gpm (0.0006 m{sup 3}/s) in piping 3 inches (0.08 m) in diameter; Re>10{sup 5}), with modest pressure drop (∼25 psi (170 KPa) in testing). In complex, aggregating waste simulants, the separator loses <25% of flow projected over months without back pulsing or chemical cleaning. Mesofluidic separation presents infrastructure advantages, reduces risk, and provides mission impact. Infrastructure advantages include implementation within existing transfer systems, plug and play without facility modifications to safety systems, and operation at low pressures. The separator is flexible in location, may be positioned within or outside of waste tanks, and may replace or augment dead-end and cross-flow filters. Mesofluidic separation reduces risk by minimizing waste (no media to replace or regenerate and no cleaning chemicals to handle and dispose) and by minimizing filter change-out consistent with as low as reasonably achievable (ALARA) exposure to workers. The potential mission impact of these separators is substantial. The separator has potential to support, simplify, and accelerate in-farm transfers and waste feed delivery. Furthermore, the separator can free up settling and holding tanks in the Direct Feed Low-Activity Waste (DFLAW) mission by reducing or eliminating post-transfer settling and wait times with the potential to free up 1 Mgal (4000 m{sup 3}) of double-shell tank space. This paper quantitatively compares mesofluidic separation to dead-end filtration, discusses scale-up results, and considers the separator's potential to efficiently and effectively reduce the long-term environmental ability of particulate-rich nuclear wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Predictive Modeling and Uncertainty Quantification in Condition Monitoring of Active Components: A Reactor Coolant Pump Use Case

This work develops data-driven models for onset of thermal barrier leakage in reactor coolant pumps. It incorporates uncertainty quantification to enhance the reliability and robustness of pre- dictions. Using synthetic data generated by the Generic Pressurized Water Reactor simulator, realistic degradation scenarios were simulated across lifecycle stages—beginning, middle, and end of life. Key variables, including differential pressure, flow rate, vibration, and temperatures, were analyzed using machine learning framework. The fully connected neural network models demonstrated exceptional performance, achieving R2 scores exceeding 0.99 and root mean square errors as low as around 8.23 × 10-2 gallon per minute (gpm) for the three stages of the lifecy- cle. UQ analysis further validated the model’s robustness, with narrow uncertainty bounds during steady-state operations and appropriately wider bounds during transitional phases, reflecting the physical behavior of the system. This work addresses important gaps in real-time condition moni- toring and regulatory compliance by integrating advanced condition monitoring technologies with UQ into IST programs. The ability to detect thermal barrier leakage early and quantify prediction reliability supports optimizing maintenance strategies while ensuring nuclear power plants’ safe and reliable operation.

99 - GENERAL AND MISCELLANEOUS↗

Beam-water Interaction System for PFAS Treatment

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental contaminants that resist conventional water treatment due to the strength of their carbon fluorine bonds. Electron-beam irradiation has shown potential for PFAS degradation; however, its effectiveness is limited by shallow energy penetration, restricting treatment to the upper region of the water surface. This project addresses this limitation through the design of a compact mixing chamber and recirculation system to enhance surface renewal and improve treatment efficiency. The system, constrained to approximately 10 cm 20 cm 20 cm, was developed using computer-aided design, computational fluid dynamics (CFD), and MATLAB-based hydraulic analysis to evaluate flow behavior, head loss, and pump compatibility. A perforated-baffle geometry and controlled flow range of 1 3 GPM were implemented to promote uniform mixing while maintaining a stable free surface for electron-beam exposure. Modeling results indicate improved flow distribution and reduced dead zones, supporting more consistent interaction between contaminated water and the beam. The final design enhances hydrodynamic performance within system constraints, contributing to scalable electron-beam water treatment technologies for improved PFAS degradation.

Ramos, Gerardo [Northern Illinois U.]↗

Hydraulic Permeability of Resorcinol-Formaldehyde Ion-Exchange Resin - Effects of Oxygen Uptake and Radiation

An ion-exchange process, using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the U.S. Department of Energy's (DOE) Hanford site in Washington State. The RF resin is also being evaluated for use in the proposed Small Column Ion Exchange (SCIX) system, which is an alternative treatment option at DOE's Savannah River Site (SRS)in South Carolina. Testing at ORNL will determine the impact of radiation exposure and oxygen uptake by the RF resin on the hydraulic permeability of the resin. Samples of the resin will be removed periodically to measure physical properties (bead size and compressibility) and cesium capacity. The proposed full-scale treatment system at Hanford, the Waste Treatment Plant (WTP), will use an ion-exchange column containing nominally 680 gal of resin, which will treat 30 gpm of waste solution. The ion-exchange column is designed for a typical pressure drop of 6 psig, with a maximum of 9.7 psig. The lab-scale column is 3-in. clear PVC pipe and is prototypic of the proposed Hanford column. The fluid velocity in the lab-scale test will be much higher than for the full-scale column, in order to generate the maximum pressure drop expected in that column (9.7 psig). The frictional drag from this high velocity will produce similar forces on the resin in the lab-scale column as would be expected at the bottom of the full-scale column. The chemical changes in the resin caused by radiation exposure and oxygen uptake are expected to cause physical changes in the resin that could reduce the bed porosity and reduce the hydraulic permeability of the resin bed. These changes will be monitored by measuring the pressure drop through the lab-scale column and by measuring the physical properties of samples of the resin. The test loop with the lab-scale column is currently being fabricated, and operation will start by late May. Testing will be completed by the end of August.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Error Characteristics and Scale Dependence of Current Satellite Precipitation Estimates Products in Hydrological Modeling

Satellite precipitation estimates (SPEs) are promising alternatives to gauge observations for hydrological applications (e.g., streamflow simulation), especially in remote areas with sparse observation networks. However, the existing SPEs products are still biased due to imperfections in retrieval algorithms, data sources and post-processing, which makes the effective use of SPEs a challenge, especially at different spatial and temporal scales. In this study, we used a distributed hydrological model to evaluate the simulated discharge from eight quasi-global SPEs at different spatial scales and explored their potential scale effects of SPEs on a cascade of basins ranging from approximately 100 to 130,000 km 2 . The results indicate that, regardless of the difference in the accuracy of various SPEs, there is indeed a scale effect in their application in discharge simulation. Specifically, when the catchment area is larger than 20,000 km2, the overall performance of discharge simulation emerges an ascending trend with the increase of catchment area due to the river routing and spatial averaging. Whereas below 20,000 km 2 , the discharge simulation capability of the SPEs is more randomized and relies heavily on local precipitation accuracy. Our study also highlights the need to evaluate SPEs or other precipitation products (e.g., merge product or reanalysis data) not only at the limited station scale, but also at a finer scale depending on the practical application requirements. Here we have verified that the existing SPEs are scale-dependent in hydrological simulation, and they are not enough to be directly used in very fine scale distributed hydrological simulations (e.g., flash flood). More advanced retrieval algorithms, data sources and bias correction methods are needed to further improve the overall quality of SPEs.

DTVGM↗

Detecting ocean surface wind using the TRMM precipitation radar

Although designed specifically for the measurement of precipitation in the atmosphere, the Precipitation Radar (PR) onboard the Tropical Rainfall Measuring Mission (TRMM) satellite alsomeasures the normalized radar cross-section at the Earth's surface. As such, this instrument providesan interesting opportunity to explore an alternative radar configuration in the satellite remote sensingnf ocean winds. In particular, it can measure the strength of the ocean winds in relatively higherspatial resolution as compared to the conventional scatterometer systems presently in use. The addition of wind sensing capability to precipitation radar also complements its rain profiling capabilitynicely and allows coincident wind and rain measurements. In this paper, we discuss the new ocean wind algorithm developed specifically for TRMM PR using maximum likelihood estimation. A uniquefeature of this wind algorithm is its capability to incorporate measurement sensitivity and noiseinformation consistently in both the along-track and cross-track directions. This PR wind algorithm hasbeen tested using data from the TRMM Microwave Imager (TMI) and NASA QuikSCAT scatterometer.Excellent agreement on the retrieved wind strengths is achieved among three sensors.

precipitation radar TRMM GPM CAMEX-4 ocean surface↗

Rainfall observations by an airbourne dual-fequency precipitation radar during CAMEX-4

The 2d Generation Precipitation Radar is a new design for a dual-frequency (13.4 and 35.6 GHz) spaceborne precipitation radar. An airborne PR-2 simulator has been developed to demonstrate key technologies. This airborne system was flown on the NASA DC-8 aircraft during the 4th Convection and Moisture Experiment in 2001. Data were acquired in Tropical Storms Chantal and Gabrielle, Hurricane Humberto, and in several more localized convective systems. The authors discuss the design of thePR-2 airborne radar and show observations from CAMEX-4. Overall, the observations validated the design of PR-2 and provide an extensive data set for scientific analysis.

precipitation radar TRMM GPM CAMEX-4↗