Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

TH-AB-201-05: Determining the Direction Distribution of the Primary Radiation for a Cyberknife-M6

Purpose: Radiation protection regulatory differentiates between primary and scatter radiation. Whereas for conventional clinical linear accelerators the solid angle for primary radiation is planar, the Cyberknife (Accuray Inc., Sunnyvale, CA) may point its beam in all spatial directions. In order to be able to judge on radiation protection calculations for a Cyberknife-M6 vault, the direction distribution for delivered plans was evaluated based on clinical experiences. Methods: The log-files of 121 delivered patient treatment plans were exported, divided into cranial and extra-cranial treatments and the delivered monitor units (MU) together with the corresponding beam directions were analyzed. This MU-weighted spatial distribution was then projected to a 9.5 × 5.9 × 3.9 m{sup 3} vault, generating an “intensity map” using a binning of 50 × 50 cm{sup 2}. The factor of direction (FOD) is reported as a fraction of the total applied MUs to the walls, ceiling and floor in the perspective of a patient lying in head-first-supine position on the couch. In this study, the term intFOD refers to the integral FOD and maxFOD refers to the maximal FOD for a single bin. Results: For all kind of treatments and collimators, intFOD and maxFOD for the wall behind the patient’s head is 0.0. The intFOD for the floor varies between 0.65 and 0.74. For the ceiling, maxFOD is 0.002 and 0.0 for cranial and extra-cranial cases, respectively. The intFOD for the wall at the patient’s feet, is 0.094 for cranial and 0.005 for extra-cranial cases. There is nearly no difference between the maxFOD of the right and left wall for cranial cases, whereas for extra-cranial cases these numbers differ by a factor of 1.75. Conclusion: The varying FODs for the Cyberknife were quantified based on delivered treatment plans. These findings are helpful regarding the design of Cyberknife vaults.

60 APPLIED LIFE SCIENCES↗

Sensor Suitcase Tablet Software

The Retrocommissioning Sensor Suitcase is targeted for use in small commercial buildings of less than 50,000 square feet of floor space that regularly receive basic services such as maintenance and repair, but don't have in-house energy management staff or buildings experts. The Suitcase is designed to be easy-to-use by building maintenance staff, or other professionals such as telecom and alarm technicians. The software in the hand-held is designed to guide the staff to input the building and system information, deploy the sensors in proper location, configure the sensor hardware, and start the data collection.

Source record↗

WORM (Write One, Read Many)

WORM (Write One, Run Many) is an easy to use, cross platform, embedded and extensible, functional programming language designed to facilitate the creation of input-decks for computer codes that use standard ASCII text files for input. WORM makes it easy to create generic (yet, complex and powerful) reusable models. Additionally its nature allows for complex calculations and routines to be coded once and easily reused, further simplifying the creation of input decks. WORM (Write One, Run Many) is a powerful and versatile tool designed to improve the efficiency of today’s criticality safety analyst by allowing: + input decks for parametric studies to be created quickly and easily, + calculations and variables to be imbedded into any input deck, thus allowing for meaningful parameter specifications, + problems to be specified using any combination of units, and + complex mathematically defined models to be created. A very simple syntax is employed, and therefore the WORM is easy to learn. A WORM model is essentially a standard input deck with some of its numerical values replaced by WORM code. WORM code may include and evaluate the following mathematical operators and functions: addition, subtraction, multiplication, division, exponentiation, modulus, sine, cosine, tangent, arcsine, arccosine, arctangent, the natural logarithm, logarithm base 10, integer truncation, absolute value, and random number. Several common constants, e.g., pi, e, and Avogadros’s Number (both as 6.022e23 and 0.6022), are predefined in WORM. Additionally, many unit conversion factors are also predefined: millimeters, meters, inches, feet, yards, and mils to centimeters; kilograms, pounds, and ounces to grams; liters, milliliters, gallons, and fluid ounces to cubic centimeters; and angular degrees to radians. For parametric studies, WORM supports various shorthand list specifications: the explicit step size, linear interpolation, and logarithmic interpolation. The list notation sequentially assigns multiple values to a name. WORM creates an input deck for each value of the name. If multiple lists are used, WORM steps through each list individually, i.e., WORM creates input decks corresponding to each and every permutation of the list values. Additionally, a library of standard material definitions and Perl subroutines are included. Any one of these files can be incorporated into the subject model with a simple WORM read command. WORM is completely written in Perl, the Practical Extraction and Reporting Language. Perl is one of the most portable programming languages available today. As such, the WORM works on practically any computer platform.

Sartor, Raymond↗

REO Monthly

A spreadsheet written in Microsoft Excel that evaluates combinations of renewable energy technologies at a site and identifies the combination that minimizes life cycle cost. Constraints on the optimization such as percent of energy from renewable, available land area; available investment capital, etc. make the optimization more useful. Inputs to the model include building location, number of square feet and floors; monthly energy use and cost for electric and any other fuels. Outputs include size of each RE technology total investment, utility costs, O&M costs; percent renewable; life cycle cost; rate of return; CO2 savings.

Walker, HowardAndrew↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Abstract Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high-flow-rate [50 cubic feet per minute (CFM) and higher] 12-VDC (where VDC refers to voltage direct current) fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower-flow-rate (35 CFM) 120-VAC (where VAC refers to voltage alternating current) fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsets for these black-and-white pyranometers are always small, usually no more than 1 W m−2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated and ventilated pyranometers. An important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.

14 SOLAR ENERGY↗

OPERATING EXPERIENCE AND ITS RELATIONSHIP TO EMBEDDED DIGITAL DEVICES IN SAFETY SYSTEMS

Interest in embedded digital devices (EDDs) for monitoring and providing control of components is increasing and the added functionality digital brings such as diagnostics, displays, control functions is welcomed in both the nuclear and other industries. As a result, pure analog-based components continue to disappear from the industrial I&C marketplace. Equipment with EDDs, also known by related terms such as smart devices, intelligent devices, and digital devices of limited functionality, can include sensors, breakers, priority logic modules, time delay relays, pumps, valve actuators, motor control centers, and uninterruptible power supplies. Not only is equipment consisting of analog and older digital technology being replaced with commercial grade products containing EDDs, but EDDs can also be retrofitted to work with existing components. EDDs may be installed physically within a component, such as in a relay. There are also external devices that some would not consider an EDD, but that operate in almost all technical ways identically to one internal to a component such as in a valve controller. In fact, the digital portions may be located hundreds of feet from the actual component.Due to the potential of being used in an identical manner and without alteration from their application in other industries, operating experience (OpE) for EDDs may be much more applicable than in the case of other more system level devices. Clear separation and independence of functionality provided with EDDs may also allow greater applicability of existing OpE from industry for changes that can be shown not to affect its safety function. However, OpE also demonstrates issues with different conditions between other industries and nuclear power plants, such as issues with undeclared changes or undeclared digital devices and the new failure modes they may introduce, issues with the reporting of OpE in industry, and a lack of transparency into OpE for EDDs.Understanding and addressing these issues will be key in the future use of EDDs in nuclear power plants, but failure rate data is difficult to obtain for EDDs, and lessons learned from the use of EDDs are difficult to collect and identify.Key words: embedded digital device, smart device, operating experience, failure modes

Muhlheim, Michael↗

Transitioning from Cobalt-60 to X-Ray or E-Beam for Medical Sterilization: Filling Data and Education Gaps

The Office of Radiological Security (ORS) within the U.S. DOE’s National Nuclear Security Administration (NNSA) is charged to “work with government, law enforcement, and businesses across the globe to protect radioactive sources used for medical, research, and commercial purposes; remove and dispose of disused radioactive sources; and reduce the global reliance on high activity radioactive sources through the promotion of viable non-radioisotopic alternative technologies.” In this effort, the NNSA/ORS, along with the Office of Defense Nuclear Nonproliferation R&D, has been working with government and private entities that utilize gamma-ray irradiators in areas that include blood irradiation, radiotherapy, biology research, well logging, and radiation processing to consider alternative technologies that do not depend upon radioactive materials. In the medical device industry, nearly 50% of products are sterilized with ethylene oxide, 40.5% with cobalt-60 gamma-rays, 4.5% with electron-beam (e-beam), and <1% with X-ray.(1,2) The cobalt-60 irradiation facilities use an estimated 150 MCi of isotope to sterilize approximately 200 million cubic feet of product annually.(3) Due to growing safety regulations governing cobalt-60 use, continued advancements in e-beam and X-ray accelerator technology, and the greater irradiation durations and costs for cobalt-60 irradiation compared to e-beam and X-ray, switching to these non-radionuclide modalities is increasingly economically competitive. However, this breakdown of 40.5% cobalt-60 and 5.5% accelerator for product sterilization illustrates the difficulty that market forces and industry players have had in overcoming barriers in transitioning to non-nuclide alternatives. Besides those associated with construction of new e-beam and X-ray facilities, significant financial and regulatory obstacles are also associated with the irradiation and comprehensive testing of product constituent polymers and elastomers. The standards associated with product material performance testing are the Association for the Advancement of Medical Instrumentation (AAMI) Technical Information Report 17 (TIR 17), and its referenced American Society for Testing and Materials (ASTM) polymer testing standards. In the study now underway, and the subject of this article, the NNSA/ORS provided R&D funding to the Pacific Northwest National Laboratory (PNNL) in partnership with university researchers, leading medical product manufacturers, accelerator manufacturers, and contract sterilizers. The resulting Team Nablo (in memory of Sam Nablo) includes individuals representing PNNL, Becton Dickinson (BD), Johnson & Johnson, Stryker, Texas A&M University (TAMU), Steri-Tek, Mevex, Ion Beam Applications (IBA), and Sterigenics. The goals of this study are to 1) Identify specific polymer and/or elastomer-based medical products that are currently sterilized with gamma-rays, and for which there are data gaps and would be of greatest industry impact, 2) Work with relevant ASTM subcommittees for guidance and for potential standard revision, 3) Work with an appropriate Food & Drug Administration (FDA) office for potential collaboration on a guidance document for device manufacturers, 4) Measure the physical effects that product materials exhibit when they are given sterilization-level radiation doses from cobalt-60, e-beam or X-ray, and determine whether these effects would preclude the use of e-beam or X-ray for sterilization, 5) Communicate the resulting scientific datasets and findings via industry conferences, peer-reviewed journals, and relevant trade magazines, and 6) Post the resulting datasets on a publicly accessible website, which can be built on in future years. The end objective is to identify technical barriers preventing the adoption of X-ray and e-beam technologies, and share the results to encourage X-ray and e-beam adoption where feasible.

sterilization, alternate technologies, gamma, X-ra↗

Electrophoretic deposited TiO 2 pigment-based back reflectors for thin film solar cells

Highly reflective coatings with strong light scattering effect have many applications in optical components and optoelectronic devices. This paper reports titanium dioxide (TiO 2 ) pigment-based reflectors that have 2.5 times higher broadband diffuse reflection than commercially produced aluminum or silver based reflectors and result in efficiency enhancements of a single-junction amorphous Si solar cell. Electrophoretic deposition is used to produce pigment-based back reflectors with high pigment density, controllable film thickness and site-specific deposition. Electrical conductivity of the pigment-based back reflectors is improved by creating electrical vias throughout the pigment-based back reflector by making holes using an electrical discharge / dielectric breakdown approach followed by a second electrophoretic deposition of conductive nanoparticles into the holes. While previous studies have demonstrated the use of pigment-based back reflectors, for example white paint, on glass superstrate configured thin film Si solar cells, this work presents a scheme for producing pigment-based reflectors on complex shape and flexible substrates. Finally, mechanical durability and scalability are demonstrated on a continuous electrophoretic deposition roll-to-roll system which has flexible metal substrate capability of 4 inch wide and 300 feet long.

14 SOLAR ENERGY↗

Rhythmic Dynamics and Synchronization via Dimensionality Reduction: Application to Human Gait

Reliable characterization of locomotor dynamics of human walking is vital to understanding the neuromuscular control of human locomotion and disease diagnosis. However, the inherent oscillation and ubiquity of noise in such non-strictly periodic signals pose great challenges to current methodologies. To this end, we exploit the state-of-the-art technology in pattern recognition and, specifically, dimensionality reduction techniques, and propose to reconstruct and characterize the dynamics accurately on the cycle scale of the signal. This is achieved by deriving a low-dimensional representation of the cycles through global optimization, which effectively preserves the topology of the cycles that are embedded in a highdimensional Euclidian space. Our approach demonstrates a clear advantage in capturing the intrinsic dynamics and probing the subtle synchronization patterns from uni/bivariate oscillatory signals over traditional methods. Application to human gait data for healthy subjects and diabetics reveals a significant difference in the dynamics of ankle movements and ankleknee coordination, but not in knee movements. These results indicate that the impaired sensory feedback from the feet due to diabetes does not influence the knee movement in general, and that normal human walking is not critically dependent on the feedback from the peripheral nervous system.

59 BASIC BIOLOGICAL SCIENCES↗

Temperature and Pressure Data Brady Monitoring Well SP-2

Static Pressure and Temperature Log for Brady monitor well SP-2. This data was taken from Well SP-2 which is part of the Brady Hot Springs Geothermal Site. The data contains pressure and temperature vs depth data for RIH (run in hole) Static conditions and POOH (pull out of hole) Static conditions. The data was recorded on 2/18/2015 and measurements reach a depth of 4392 feet.

15 GEOTHERMAL ENERGY↗

West Flank Coso FORGE: MT Station Locations

This data includes the locations of the MT data collected in and around the Coso Geothermal field that covered the West Flank area. These are the data that the 3D MT models were created from that were discussed in Phase 1 of the West Flank FORGE project. The projected coordinate system is NAD 1927 State Plane California IV FIPS 0404 and the Projection is Lambert Conformal Conic. Units are in feet.

15 GEOTHERMAL ENERGY↗

Glass Buttes Well 52-33 Core Log

Core log from Glass Buttes Well 52-33, drilled by Geodrill Rig 6 in 2014 to a depth of 3000 feet. Logged at 500 ft intervals.

15 GEOTHERMAL ENERGY↗

Summary Fracturing of Coso Samples with StimuFrac

Lab-scale stimulation was performed on Coso samples obtained from a single core (1623 feet TVD, reservoir Coso CGC 18-27) using StimuFrac and control fluid in the absence of stimuli-responsive polymer.

15 GEOTHERMAL ENERGY↗

kISMET Core Photos and Descriptions

These core photos and descriptions were taken from the five boreholes that were drilled as part of the kISMET SubTER project conducted at the Sanford Underground Research Facility (SURF) in Lead, SD. The boreholes are subvertical in orientation, and were drilled on the 4850 level of SURF on the West Drift, about 450 feet from Governor's Corner. The well heads for the five wells are in a line, but the outer two wells (k001 and k005) were deviated to form a five-spot configuration at 50 m depth. Four of the five boreholes have a nominal depth of 50 m and have HQ core - the fifth, located in the center (k003) was drilled to a depth of 100m and has NQ core. The central borehole was used for stress and hydraulic fracturing - the other four boreholes were used for monitoring purposes. Core logging was conducted by Paul Cook (LBNL), Bill Roggenthen (SDSMT), and Drew Siler (LBNL). All core consists of rocks from the Poorman Formation. Some of the core photos are missing. These have been documented in the included spreadsheets labeled with the well name and the word missing. The locations of the boreholes are documented on the included map and spreadsheet.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Well 56-32 Drilling Data and Logs

This dataset consists of drilling data (Pason data spreadsheets, daily reports, days v. depth, mud logs), Schlumberger logs (FMI, shear anisotropy analysis, memory, sonic, array induction/spectral density/dual spaced neutron/gamma ray/caliper, spectral GR/temperature, and Gardner density correlation), and an end of well report (EOWR) for Utah FORGE well 56-32. This is a vertical well that will be used for seismic monitoring. It was drilled between February 7th and February 21st 2021 to a depth of 9,145 feet. More information about this well can be found at: https://utahforge.com/2021/02/09/drilling-progress-of-well-56-32/ (linked below)

15 GEOTHERMAL ENERGY↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

Utah FORGE: Well 16B(78)-32 Pressure-Temperature Logs March - April 2024

This dataset consists of Baker Hughes Pressure-Temperature gauge readings on fiber optics in Utah FORGE Well 16B(78)-32. This gauge is at a measured depth of 7,056.67 feet. The true vertical depth can be determined from the well survey data, which is linked below. The data consists of time series pressure-temperature data and plots from March 26th - April 20th 2024.

15 GEOTHERMAL ENERGY↗

Utah FORGE: Well 16B(78)-32 Distributed Temperature Sensing Data from April and May 2024

This dataset includes Neubrex Energy Services fiber optic distributed temperature sensing (DTS) data from well 16B(78)-32 during stimulation and circulation, including interaction with well 16A(78)-32, during April and May 2024. The DTS data are stored in HDF5 file format and are accompanied by a PowerPoint report on the study. All times in this dataset are in UTC. Depths are in MD relative to Kelly Bushing Height, and temperatures are in degrees Fahrenheit. All DTS measurements were made using a Yokogawa 3000DTSX Distributed Temperature Sensing Interrogator Unit, with a spatial sampling interval of 3.28 feet and a temporal sampling rate of 129 seconds. The third-party Pressure-Temperature Gauge data should be used with caution after April 20, 2024, as its performance is not considered reliable beyond this date.

15 GEOTHERMAL ENERGY↗