Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEASIBILITY STUDIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The Connected We St@nd programme: A feasibility pilot study of an online self‐management intervention for adults on in‐centre haemodialysis and family caregivers

Abstract Objective The ‘Connected We St@nd’ is an online self‐management intervention programme for people receiving in‐centre haemodialysis and family caregivers that combines an educational and psychosocial support component. This study aimed to evaluate its feasibility and acceptability before proceeding to a large‐scale trial. Design This was a pre‐post single‐arm feasibility pilot study conducted with adults undergoing in‐centre haemodialysis and family caregivers. Methods Feasibility was based on eligibility, consent, retention, completion and intervention adherence rates, while acceptability was assessed in post‐intervention focus group interviews. Results Twenty‐six people (16 adults on haemodialysis and 10 family caregivers) recruited through social networks completed the intervention. Consent, retention and completion rates were excellent (>90%) and eligibility (77.5%) and intervention adherence were satisfactory (69% for the psychosocial support sessions). Qualitative findings revealed that participants shared positive feelings regarding their participation in the programme. The valuable interactions with group peers and health psychologists during the support sessions, the perception of the adequacy and coherence of the programme's contents and materials and the participants' confidence in using the platform developed to deliver the intervention were some of the aspects highlighted as facilitators of intervention acceptability. Additionally, people on haemodialysis and caregivers reported that participation in the programme brought several educational and emotional benefits (e.g., additional disease‐related knowledge, improved communication and coping skills, greater confidence in managing dialysis complications or caregiving demands) that helped increase their self‐management skills and psychosocial adjustment to the demands of kidney failure and renal therapies. Conclusions The results suggested that the ‘Connected We St@nd’ programme is likely to be feasible and acceptable for adults on haemodialysis and family caregivers, thus representing a promising resource for the future of interdisciplinary renal rehabilitation. Suggestions were made to fine‐tune the intervention design to proceed with a large‐scale trial.

Sousa, Helena↗

Study of extraterrestrial disposal of radioactive wastes. Part 3: Preliminary feasibility screening study of space disposal of the actinide radioactive wastes with 1 percent and 0.1 percent fission product contamination

A preliminary study was conducted of the feasibility of space disposal of the actinide class of radioactive waste material. This waste was assumed to contain 1 and 0.1 percent residual fission products, since it may not be feasible to completely separate the actinides. The actinides are a small fraction of the total waste but they remain radioactive much longer than the other wastes and must be isolated from human encounter for tens of thousands of years. Results indicate that space disposal is promising but more study is required, particularly in the area of safety. The minimum cost of space transportation would increase the consumer electric utility bill by the order of 1 percent for earth escape and 3 percent for solar escape. The waste package in this phase of the study was designed for normal operating conditions only; the design of next phase of the study will include provisions for accident safety. The number of shuttle launches per year required to dispose of all U.S. generated actinide waste with 0.1 percent residual fission products varies between 3 and 15 in 1985 and between 25 and 110 by 2000. The lower values assume earth escape (solar orbit) and the higher values are for escape from the solar system.

Hyland, R. E.↗

Development of a NASA standard gas generator

The goals of the NASA Standard Gas Generator (NSGG) Program are to create a NASA standard gas generating cartridge, characterize its performance, and make it readily available to users. A cartridge within the same envelope as the NASA Standard Initiator (NSI) has the greatest potential use. This potential use is described in viewgraph form. Our approach for NSGG development and qualification was planned to be conducted in several phases. Test methods were developed to evaluate output performance for a variety of potential applications. A feasibility study using modified NSI's was accomplished. Preliminary and final development will be conducted with a delta qualification to evaluate the effects of manufacturing lots and environments. Feasibility study results, feasibility study conclusions, and future plans are presented.

Bement, Laurence J.↗

Results of preliminary Microwave Multi-Applications Payload (MMAP) study

A preliminary feasibility study of the microwave multi-applications payload (MMAP) system for the Spacelab has been carried out. The initial objectives of this study have been to determine the minimum equipment requirements of the MMAP and the feasibility of placing the numerous large aperture antennas in the Spacelab. The study was begun by reviewing the experimental objectives and techniques and determining areas of commonality. Emphasis was given to the determination of common RF equipment requirements. These requirementers were considered after agreement among the experiments had been reached on limiting the number of frequencies to be used in the system. This was done so that the number of antennas, transmitters, and receivers could be minimized. The electronics system block diagram and the antenna configurations were considered in some details. It was concluded that the MMAP is feasible and can be an economical method of achieving a large number of experimental goals.

Source record↗

Advanced System Thermal Fluids Solver Development for SAM

This work summarizes a feasibility study on testing numerical algorithms that are suitable and efficient for advanced system analysis code development under the mutli-physics framework, MOOSE. The key is the implementation of a high-order one-dimensional staggered-grid finite volume method (SG-FVM), and its direct interaction with the linear/nonlinear solver, PETSc. Leveraging the existing capabilities of the SAM code, significant code coverages were established in the finite volume method code. This in turn allows for a suite of test problems with different problem sizes and levels of complexity to be used to quantify the performance improvement of the finite volume method code. As evidently shown in this study, the implemented SG-FVM demonstrated superior performance improvement against a direct finite element method implementation through MOOSE for the wide range of selected problems. On two computer systems, the speedup was observed to be significant, with at least one order of magnitude of solving time reduction. In addition, for a complex reactor model, transient simulation was performed using the finite volume method code, the results of which agree very well with the reference results from the finite element method code. Overall, this study demonstrates a successful feasibility study on the proposed numerical algorithms and software structure to support advanced system analysis tool development. In this work, short-term priority development and testing items were identified, and long-term code adoption and integration plans were made for the eventual deployment of the finite volume method in the SAM code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A highly efficient error analysis program for the evaluation of spacecraft tests of general relativity with application to solar probes

A computer program is described which can be used to study the feasibility of conducting relativity experiments on a wide range of hypothetical space missions, and a few applications are presented for solar probes which approach the Sun within 0.25 to 0.35 AU. It is assumed that radio ranging data are available from these spacecraft, and that accuracies on the order of 15 meters can be achieved. This is compatible with current accuracies of ranging to Mariner spacecraft. At this level of accuracy, the range data are sensitive to a number of effects, and for this reason it has been necessary to include a total of up to 23 parameters in the feasibility studies, even though there are only two parameters of real interest in the relativity experiments.

Anderson, J. D.↗

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Lunar transit telescope lander design

The Program Development group at NASA's Marshall Space Flight Center has been involved in studying the feasibility of placing a 16 meter telescope on the lunar surface to scan the skies using visible/ Ultraviolet/ Infrared light frequencies. The precursor telescope is now called the TRANSIT LUNAR TELESCOPE (LTT). The Program Development Group at Marshall Space Flight Center has been given the task of developing the basic concepts and providing a feasibility study on building such a telescope. The telescope should be simple with minimum weight and volume to fit into one of the available launch vehicles. The preliminary launch date is set for 2005. A study was done to determine the launch vehicle to be used to deliver the telescope to the lunar surface. The TITAN IV/Centaur system was chosen. The engineering challenge was to design the largest possible telescope to fit into the TITAN IV/Centaur launch system. The telescope will be comprised of the primary, secondary and tertiary mirrors and their supporting system in addition to the lander that will land the telescope on the lunar surface and will also serve as the telescope's base. The lunar lander should be designed integrally with the telescope in order to minimize its weight, thus allowing more weight for the telescope and its support components. The objective of this study were to design a lander that meets all the constraints of the launching system. The basic constraints of the TITAN IV/Centaur system are given.

Omar, Husam A.↗

Space Power Free-Piston Stirling Engine Scaling Study

The design feasibility study is documented of a single cylinder, free piston Stirling engine/linear alternator (FPSE/LA) power module generating 150 kW-electric (kW sub e), and the determination of the module's maximum feasible power level. The power module configuration was specified to be a single cylinder (single piston, single displacer) FPSE/LA, with tuning capacitors if required. The design requirements were as follows: (1) Maximum electrical power output; (2) Power module thermal efficiency equal to or greater than 20 percent at a specific mass of 5 to 8 kg/kW(sub e); (3) Heater wall temperature/cooler wall temperature = 1050 K/525 K; (4) Sodium heat-pipe heat transport system, pumped loop NaK (sodium-potassium eutectic mixture) rejection system; (5) Maximum power module vibration amplitude = 0.0038 cm; and (6) Design life = 7 years (60,000 hr). The results show that a single cylinder FPSE/LA is capable of meeting program goals and has attractive scaling attributes over the power range from 25 to 150 kW(sub e). Scaling beyond the 150 kW(sub e) power level, the power module efficiency falls and the power module specific mass reaches 10 kg/kW(sub e) at a power output of 500 kW(sub e). A discussion of scaling rules for the engine, alternator, and heat transport systems is presented, along with a detailed description of the conceptual design of a 150 kW(sub e) power module that meets the requirements. Included is a discussion of the design of a dynamic balance system. A parametric study of power module performance conducted over the power output range of 25 to 150 kW(sub e) for temperature ratios of 1.7, 2.0, 2.5, and 3.0 is presented and discussed. The results show that as the temperature ratio decreases, the efficiency falls and specific mass increases. At a temperature ratio of 1.7, the 150 kW(sub e) power module cannot satisfy both efficiency and specific mass goals. As the power level increases from 25 to 150 kW(sub e) at a fixed temperature ratio, power module efficiency is seen to increase slightly, but at the expense of increased specific mass. An empirical equation relating power module thermal efficiency as a function of power module specific mass, power output, and temperature ratio is developed. Alternative configurations to the single cylinder, direct coupled linear alternator approach are also evaluated, but are shown to have technical drawbacks that lessen their attractiveness. The dynamic balance assembly mass (moving mass and structure) represents 20 to 30 percent of the total single cylinder power module mass. Joining two modules in a balanced opposed configuration eliminates the need for the balancer, and a hot end junction can be made without significant addition of structural mass. Recommendations are made for evaluation of advanced heat pipe concepts, tests of radial flow heat exchangers, and evaluation of high temperature alternator materials.

Jones, D.↗

Southern Indiana Ecological Conservation: Assessing Canopy Cover Dynamics and Forest Type Groupings in Southern Indiana to Inform Restoration Activities

As human influence continues to negatively impact natural habitats, timely assessment of ecosystem changes and restoration is critical to protect forest health and biodiversity. In our study, we focused on oak-hickory forests in southern Indiana. Oak-hickory forests were the dominant ecosystem dynamic in present-day Indiana for centuries until European colonization, which brought about fire suppression and, eventually, fire exclusion. Anthropogenic fire exclusion in this fire-adapted habitat led to the encroachment of mesic species, such as beech and maple trees. This process, commonly referred to as mesophication, was the focus of our study. Our team performed a feasibility study in using NASA Earth observations to support our end-user partners, Let the Sun Shine In and the US Forest Service, Hoosier National Forest, in their selection of oak-hickory restoration sites. To aid in our analysis of the forest dynamics of southern Indiana, our team used Landsat 5, 8, and 9 imageries, along with other ancillary datasets to create maps to illustrate areas that would most benefit from partners’ forest restoration and management practices. By constructing a Green Vegetation Fraction change map across our 39-year study period (1984-2023) to visualize the change in forest cover and creating a restoration suitability assessment map to reveal sites that met requirements for oak-hickory growth, we provided our partners with suitable site selection for restorative management and found that 3.3% of our entire study area and 4.4% of the Hoosier National Forest were deemed suitable. Our feasibility study benefits southern Indiana restoration by aiding our partners in efficiently selecting sites for prescribed burning, forest thinning, and other restoration management practices.

restoration↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Modular, Crushed-Rock Thermal Energy Storage Pilot Design (Final Report)

The goal of this project was to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The completed effort included a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. For the feasibility study, the Brenmiller technology was designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) NGCC plant in Astoria, New York. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. The study also included a techno-economic evaluation of a 200 MWh commercial-scale demonstration. Prior to this project, EPRI had reviewed Brenmiller’s technology, which is being built to demonstrate bGen™ at 1.7 MWe on a solar plant (Rotem) and has been designed for an NGCC facility in Italy, assessing it at technology readiness level (TRL) 5. Brenmiller is also conducting a separate 1-MWth pilot with NYPA that pairs a bGen™ module with a microturbine for a combined-heat-and-power (CHP) application to improve efficiency and provide flexibility. The next-step pilot being designed as part of this project would represent a 5-fold increase in scale, versus Rotem, and would show the technology’s ability to provide effective and economical energy storage, bringing the technology to TRL 6. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. The main objective of the work completed by the Electric Power Research Institute, Inc. (EPRI), Brenmiller Energy (Brenmiller), New York Power Authority (NYPA), and United E&C (formerly AECOM) was to perform a Phase I feasibility study on the integration of a crushed-rock thermal energy storage (TES) with a fossil plant. Under this project, the EPRI-led team successfully completed a feasibility study to prepare for the potential future Phase II pre-front end engineering design (pre-FEED) to implement a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. Specific deliverables under this project included the Technology Maturation Plan, Conceptual Study, Techno-Economic Assessment, Technology Gap Assessment, Project Plan for Phase II (submitted as Phase II Renewal Application), Commercialization Plan, and the Final Report (this document). This Final Report includes a compilation of the various summary reports that were prepared during the 12-month schedule of the Phase I project execution under award DE-FE0032017.

03 NATURAL GAS↗

Current Progress of the Final Design of a Subcritical Assembly at the Oak Ridge National Laboratory

During the past decade, the US Department of Energy (DOE)/National Nuclear Security Administration (NNSA) Nuclear Criticality Safety Program (NCSP) has been coordinating nuclear criticality safety (NCS) courses to provide training and qualification to new staff, supervisors, managers, regulators, and other professionals involved with NCS. To address the growing need for more NCS training possibilities, a subcritical assembly was designed at Oak Ridge National Laboratory (ORNL). The Oak Ridge Subcritical Assembly (ORSA), operated at ORNL, could be used in a new course for fissile material handlers/operators or as a backup training facility for currently existing NCSP hands-on NCS training. This paper describes some of the design steps necessary for obtaining a final ORSA design, beginning with a successful feasibility study performed in 2020. Numerous parameters within each main element of the assembly were considered, such as the reflector used, the type of fuel coating or plating used, and the number of fuel plates used. The design choices related to each parametric study described in this paper are detailed and justified at the end of each subsection. An overview of the current final design characteristics of ORSA and the experiments’ possibilities is also provided. ORSA will be built with fuel plates from legacy Aerojet General Nucleonics (AGN)-201M research reactors currently stored at the Y-12 National Security Complex (Y-12). The cylindrical fuel plates comprise UO 2 particles embedded in polyethylene and have a nominal enrichment of 19.5 ± 0.5 wt % 235 U. The basis for the final design was the feasibility study from 2020. In the feasibility study, ORSA achieved k eff = 0.95, corresponding to a multiplication factor of 20, with approximately 620 g of 235 U (four 4 cm plates, three 2 cm plates, and two 1 cm plates) and an 8.5 cm thick graphite reflector radially and on top of the assembly. The bottom of the assembly has a graphite thickness of 5 cm, and the chosen graphite density was 2.3 g/cm 3 . All design calculations were performed using SCALE 6.2.4 KENO-VI and with the ENDF/B VII.1 Continuous Energy cross-section library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Storage for Load-Following and Clean Power: Duct-firing of Hydrogen to Improve the Capacity Factor of NGCC Plants (Final Report, Phase I Conceptual Study)

The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and the proposed system is an improvement over alternate low carbon dispatchable power options. Our demonstration will include 54 MWh of hydrogen storage. CO 2 capture inherent to the CHG process can capture 90% of the CO 2 (with upgrades to >98%) in a commercial system (~300 MWth) for sequestration or other uses. The hydrogen will be utilized in a duct burner in a Heat Recovery Steam Generator (HRSG) integrated with the existing Southern Company fossil asset. Here, the firing rate of the duct burner is varied to let the plant respond to fluctuations of electrical load. However, H 2 production is relatively constant by storing H 2 , and revenues are improved by arbitrage between use of low-cost off-peak variable electricity generation or use of stored H 2 under peak demand. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via system requirements review with the whole team. These requirements were then incorporated into/iterated with our Heat & Mass Balance models and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Our system generates power at 17.4% lower cost than other low carbon approaches for the H 2 generation, H 2 compression and storage, carbon sequestration, and HRSG added electricity production for a large-scale duct-fired system. Our team recommends completing the Phase II Pre-FEED study for the proposed system as the next step for the project and its tasks will achieve the overall objective and be ready to launch the FEED. The Pre-FEED tasks include updating the requirements, Concept of Operations, plant scope/process description, component modeling, system modeling, performance estimates, emission estimates, block flow diagrams, fluid/process conditions (PFD), utility usage, and facility sizing/definition. The approach will be to complete these updates in a greater level of detail for the selected site. The approach for developing the EIV is to use the updated results, including model outputs, for carbon dioxide and waste streams.

03 NATURAL GAS↗