Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experimental Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Characterizing the Thermal Column Beam in the University of Massachusetts Lowell Research Reactor

The University of Massachusetts Lowell operates a 1 MW, light water cooled and moderated Research Reactor (UMLRR) fueled by low-enriched uranium to generate neutron flux that is used at a variety of in-core and beam port facilities within the reactor to perform irradiation experiments for academic and industrial research. One of the irradiation sites is a graphite-moderated thermal column designed to deliver a collimated beam of thermal neutrons to a neutron radiography imaging system. A detailed characterization of the neutron beam is essential for the design and interpretation of experiments at the facility and for radiation safety. This work aimed to characterize the neutron flux and energy spectrum in the UMLRR thermal column beam by employing experimental and computational methods known as the foil activation and spectrum unfolding technique. A previously existing Monte Carlo N-Particle transport (MCNP) model of the UMLRR reactor core has been extended to the thermal column where the neutron flux and energy spectrum have been computed and experimentally validated. This work employed the foil activation and spectrum unfolding technique along with neutron transport computation to extend the knowledge of the neutron fluence and energy spectrum from the UMLRR core to the adjacent thermal column beam. Radiography systems are used for materials characterization, studying dynamic behavior of engineering systems, and for nuclear forensics applications. Foil activation is an experimental method where thin foils of highly pure materials are placed in the beam where interactions between the neutrons and the foil material activate radioisotopes in the foils whose activities can be measured after the irradiation. Downstream computation with MCNP and the spectrum unfolding code SAND can deconvolute the neutron fluence and energy spectrum that must have been necessary to induce the production rates of radioisotopes that were obtained through foil activation. The necessary ingredients for successful spectrum unfolding are the experimentally measured production rates and some a priori (initial guess) knowledge of the flux spectrum. The thermal column is equipped with a neutron radiography imaging system, so any experimenters who desire to use neutron radiography at UMass Lowell will benefit significantly from knowing the characteristics of the neutron beam. Comprehensive knowledge of these characteristics of the beam is essential to compare and benchmark results obtained for similar experiments at other facilities. The Integrated Nuclear Security and Safeguards Laboratory (INSSL) is pursuing the investigation of the performance of self-healing materials under stress-strain environments and the characterization of radiation detectors and special containers for storing and transporting nuclear material. This work contributes to the improvement of the current radiography system, expands the utility of the system for nuclear safeguards and security application and provides information that will enhance the general safety of the UMLRR experimental facilities. The main objective of this work has been achieved; an appropriate neutron flux spectrum for the UMLRR thermal column beam has been determined using the foil activation method followed by spectrum unfolding. There now exists an experimentally validated computational model of the neutron flux spectrum and the thermal column's neutron environment is characterized. We can conclude that the thermal column is well characterized; an appropriate neutron flux spectrum has been determined through an experimentally validated computational model. Future experimenters interested in the thermal column may now expand on the computational model or use the spectral information for their own purposes. The knowledge gained herein will be helpful for the INSSL's future work using neutron radiography to analyze the effectiveness of self-healing materials and special containers. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An adaptive Gaussian process-based method for efficient Bayesian experimental design in groundwater contaminant source identification problems: ADAPTIVE GAUSSIAN PROCESS-BASED INVERSION

Surrogate models are commonly used in Bayesian approaches such as Markov Chain Monte Carlo (MCMC) to avoid repetitive CPU-demanding model evaluations. However, the approximation error of a surrogate may lead to biased estimations of the posterior distribution. This bias can be corrected by constructing a very accurate surrogate or implementing MCMC in a two-stage manner. Since the two-stage MCMC requires extra original model evaluations, the computational cost is still high. If the information of measurement is incorporated, a locally accurate approximation of the original model can be adaptively constructed with low computational cost. Based on this idea, we propose a Gaussian process (GP) surrogate-based Bayesian experimental design and parameter estimation approach for groundwater contaminant source identification problems. A major advantage of the GP surrogate is that it provides a convenient estimation of the approximation error, which can be incorporated in the Bayesian formula to avoid over-confident estimation of the posterior distribution. The proposed approach is tested with a numerical case study. Without sacrificing the estimation accuracy, the new approach achieves about 200 times of speed-up compared to our previous work using two-stage MCMC.

Zhang, Jiangjiang↗

A Separation Voltage Polarity Switching Method for Higher Sample Loading Capacity and Better Separation Resolution in Transient Capillary Isotachophoresis Separation

A separation voltage polarity switching transient capillary isotachophoresis (PS-tCITP) was developed to overcome a major sample loading volume limitation in transient capillary isotachophoresis (tCITP). The fundamental idea of PS-tCITP is to let sample ions move back and forth in the separation capillary during their initial isotachophoresis focusing stage by switching the polarity of separation voltage, in order to both increase the sample loading volume and improve the separation efficiency as compared to the conventional tCITP method. The experimental evaluation of the novel PS-tCITP method by using two peptide standards at 2 µM concentration showed that the maximum sample loading volume could be increased from 45% of the total separation capillary volume in tCITP to 70% in PS-tCITP, which resulted in a more than 1.5 fold increases in the peptide peak intensity at a given length/volume of the separation capillary. Due to the consecutive focusing of sample volume from each polarity switching of separation voltage, the separation time window at a given sample loading volume was also increased significantly in PS-tCITP as compared to tCITP. Experiment comparison between tCITP and PS-tCITP at 45% sample loading volume using the same setup showed that the migration time difference between the two peptide peaks increased from 0.3 min in tCITP to 0.363 min in PS-tCITP with similar peak widths and heights, resulting in roughly a 21% improvement in separation resolution. The performance advantages of PS-tCITP separation over tCITP separation was further verified by using a mixture of six peptide standards.

Wu, Huanming↗

Synthesis of graphene by cobalt-catalyzed decomposition of methane in plasma-enhanced CVD: Optimization of experimental parameters with Taguchi method

This article describes the significant roles of process parameters in the deposition of graphene films via cobalt-catalyzed decomposition of methane diluted in hydrogen using plasma-enhanced chemical vapor deposition (PECVD). The influence of growth temperature (700–850 °C), molar concentration of methane (2%–20%), growth time (30–90 s), and microwave power (300–400 W) on graphene thickness and defect density is investigated using Taguchi method which enables reaching the optimal parameter settings by performing reduced number of experiments. Growth temperature is found to be the most influential parameter in minimizing the number of graphene layers, whereas microwave power has the second largest effect on crystalline quality and minor role on thickness of graphene films. The structural properties of PECVD graphene obtained with optimized synthesis conditions are investigated with Raman spectroscopy and corroborated with atomic-scale characterization performed by high-resolution transmission electron microscopy and scanning tunneling microscopy, which reveals formation of continuous film consisting of 2–7 high quality graphene layers.

36 MATERIALS SCIENCE↗

TU-F-BRE-06: Flattening-Filter-Free Beam Quality Correction Factor Determination Using Experimental and Monte Carlo Methods

Purpose: To investigate beam quality correction factors for the flattening-filter-free (FFF) energies of the TrueBeam™ accelerator based on a dosimetry formalism for small and nonstandard fields. Methods: Three detectors - an Exradin W1 scintillator, Sun Nuclear EDGE diode, and LiF(Mg,Tl) TLD-100 chips - were investigated to determine their applicability as tools to measure quality correction factors for ionization chambers in the small and nonstandard fields of the TrueBeam™. Volume-averaging effects and energy dependence were observed in fields ranging from 1×1 to 40×40 cm{sup 2} for 6 MV and 10 MV beam energies using both FFF and flattened beam modes. Correction factors were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 reference-class microchamber. Beam quality corrections were also obtained using a benchmarked model of the TrueBeam™ created with the BEAMnrc user code of EGSnrc. Results: All three detectors demonstrated measureable energy dependence in the megavoltage range. The EDGE diode was deemed the most appropriate tool for beam quality correction factor measurements due to its low energy dependence and small size; however, alanine will be used in the future to reduce energy dependent effects even further. Measured k{sub Qmsr,Q} corrections of up to 4% were found for the 6MV FFF and 10 MV FFF beams, corresponding to a discrepancy of up to 3% compared to TG-51-determined dose. Up to a 10% k{sub Qclin,Qmsr} correction was measured for small fields referenced to a 10×10 cm{sup 2} field of the same energy. Much larger corrections were determined using the Monte Carlo model, and these discrepancies require further investigation. Conclusion: Progress has been made toward determining beam quality correction factors for the small and nonstandard fields of the TrueBeam™ accelerator. Further work must be done to ensure greater accuracy in patient treatments with this new modality.

07 ISOTOPE AND RADIATION SOURCES↗

Laser heating of finite two-dimensional dust clusters: A. Experiments

Laser manipulation allows to control the kinetic particle temperature in dusty plasmas. Different methods of laser heating for plasma crystals are benchmarked experimentally. The methods are analyzed with respect to homogeneity and isotropy in a spatial, temporal, and statistical sense. It is shown that it is possible to achieve particle dynamics very close to thermal equilibrium and that laser heating methods allow for a detailed study of phase transitions in finite size systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum process identification: a method for characterizing non-markovian quantum dynamics

Established methods for characterizing quantum information processes do not capture non-Markovian (history-dependent) behaviors that occur in real systems. These methods model a quantum process as a fixed map on the state space of a predefined system of interest. Such a map averages over the system's environment, which may retain some effect of its past interactions with the system and thus have a history-dependent influence on the system. Although the theory of non-Markovian quantum dynamics is currently an active area of research, a systematic characterization method based on a general representation of non-Markovian dynamics has been lacking. In this article we present a systematic method for experimentally characterizing the dynamics of open quantum systems. Our method, which we call quantum process identification (QPI), is based on a general theoretical framework which relates the (non-Markovian) evolution of a system over an extended period of time to a time-local (Markovian) process involving the system and an effective environment. In practical terms, QPI uses time-resolved tomographic measurements of a quantum system to construct a dynamical model with as many dynamical variables as are necessary to reproduce the evolution of the system. Through numerical simulations, we demonstrate that QPI can be used to characterize qubit operations with non-Markovian errors arising from realistic dynamics including control drift, coherent leakage, and coherent interaction with material impurities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Grinding Forces in the Presence of Ultrasound

Formulas are derived for calculation of the grinding force in the presence of ultrasound whose amplitude changes the microcutting kinematics of the abrasive grains. The formulas are verified experimentally.

42 ENGINEERING↗

Detection of microcalcifications by characteristic magnetic susceptibility effects using MR phase image cross-correlation analysis

Purpose: To develop and evaluate a new method for detecting calcium deposits using their characteristic magnetic susceptibility effects on magnetic resonance (MR) images at high fields and demonstrate its potential in practice for detecting breast microcalcifications. Methods: Characteristic dipole signatures of calcium deposits were detected in magnetic resonance phase images by computing the cross-correlation between the acquired data and a library of templates containing simulated phase patterns of spherical deposits. The influence of signal-to-noise ratio and various other MR parameters on the results were assessed using simulations and validated experimentally. The method was tested experimentally for detection of calcium fragments within gel phantoms and calcium-like inhomogeneities within chicken tissue at 7 T with optimized MR acquisition parameters. The method was also evaluated for detection of simulated microcalcifications, modeled from biopsy samples of malignant breast cancer, inserted in silico into breast magnetic resonance imaging (MRIs) of healthy subjects at 7 T. For both assessments of calcium fragments in phantoms and biopsy-based simulated microcalcifications in breast MRIs, receiver operator characteristic curve analyses were performed to determine the cross-correlation index cutoff, for achieving optimal sensitivity and specificity, and the area under the curve (AUC), for measuring the method’s performance. Results: The method detected calcium fragments with sizes of 0.14–0.79 mm, 1 mm calcium-like deposits, and simulated microcalcifications with sizes of 0.4–1.0 mm in images with voxel sizes between (0.2 mm){sup 3} and (0.6 mm){sup 3}. In images acquired at 7 T with voxel sizes of (0.2 mm){sup 3}–(0.4 mm){sup 3}, calcium fragments (size 0.3–0.4 mm) were detected with a sensitivity, specificity, and AUC of 78%–90%, 51%–68%, and 0.77%–0.88%, respectively. In images acquired with a human 7 T scanner, acquisition times below 12 min, and voxel sizes of (0.4 mm){sup 3}–(0.6 mm){sup 3}, simulated microcalcifications with sizes of 0.6–1.0 mm were detected with a sensitivity, specificity, and AUC of 75%–87%, 54%–87%, and 0.76%–0.90%, respectively. However, different microcalcification shapes were indistinguishable. Conclusions: The new method is promising for detecting relatively large microcalcifications (i.e., 0.6–0.9 mm) within the breast at 7 T in reasonable times. Detection of smaller deposits at high field may be possible with higher spatial resolution, but such images require relatively long scan times. Although mammography can detect and distinguish the shape of smaller microcalcifications with superior sensitivity and specificity, this alternative method does not expose tissue to ionizing radiation, is not affected by breast density, and can be combined with other MRI methods (e.g., dynamic contrast-enhanced MRI and diffusion weighted MRI), to potentially improve diagnostic performance.

60 APPLIED LIFE SCIENCES↗

Study of the filter method for neutron pulse-height distributions measured with organic scintillators

Identification of neutron sources is of interest in several fields, such as homeland security or basic nu-clear physics. Organic scintillators offer the possibility to unfold fast-neutron energy spectra. Since organic scintillators are sensitive to neutrons and gamma-rays, a method to discriminate these two types of particles is required. This paper is focused on investigation of the discrimination properties of the filter method by using a new procedure. We compare the results of an experimental filter method to a digital pulse-shape discrimination (PSD) method based on charge integration. In addition, these methods are compared to the simulation results obtained with the MCNPX-PoliMi code. The experimental and nu-merical investigations were performed with a 252Cf spontaneous-fission neutron source. The integration of the number of counts gave the relative differences between the experimental filter and digital PSD neutron pulse-height distributions (PHDs) and simulated PHDs less than approximately 5% in the range between 60 keVee and 1.715 MeVee of light output. Above 1.715 MeVee, the PSD method has advantages over the filter method, due to the filter method having significantly worse counting statistics. The results show that the filter method has potential for robust neutron measurements when the PSD method cannot be applied, such as for ‘old’ organic plastic scintillators without PSD capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanodosimetry: Principle and Current Status

Due to the success of theoretical track structure Monte Carlo simulations, showing that features of ionization patterns on the nanometer level are important for the biological effectiveness of ionizing radiation, several new methods for experimental track structure investigations have been developed in recent years. These methods all use the principle of density scaling in low-pressure gas to probe track structure in macroscopic dimensions, ideally with single-ionization resolution. The new field of experimental track structure investigation, which has been called nanodosimetry, can be approached in two ways: (1) the number of ionizations in a defined, ideally wall-less, sensitive volume is registered per single primary particle and cluster size distributions are obtained, or (2) the full track structure of an ion track segment is 'imaged'. Existing nanodosimetric methods are based on the first approach, but a track structure imaging detector is currently under development at Loma Linda University. This contribution will review the principle and existing technical approaches to nanodosimetry and will give an outlook on future developments and applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cone beam x-ray luminescence computed tomography: A feasibility study

Purpose: The appearance of x-ray luminescence computed tomography (XLCT) opens new possibilities to perform molecular imaging by x ray. In the previous XLCT system, the sample was irradiated by a sequence of narrow x-ray beams and the x-ray luminescence was measured by a highly sensitive charge coupled device (CCD) camera. This resulted in a relatively long sampling time and relatively low utilization of the x-ray beam. In this paper, a novel cone beam x-ray luminescence computed tomography strategy is proposed, which can fully utilize the x-ray dose and shorten the scanning time. The imaging model and reconstruction method are described. The validity of the imaging strategy has been studied in this paper. Methods: In the cone beam XLCT system, the cone beam x ray was adopted to illuminate the sample and a highly sensitive CCD camera was utilized to acquire luminescent photons emitted from the sample. Photons scattering in biological tissues makes it an ill-posed problem to reconstruct the 3D distribution of the x-ray luminescent sample in the cone beam XLCT. In order to overcome this issue, the authors used the diffusion approximation model to describe the photon propagation in tissues, and employed the sparse regularization method for reconstruction. An incomplete variables truncated conjugate gradient method and permissible region strategy were used for reconstruction. Meanwhile, traditional x-ray CT imaging could also be performed in this system. The x-ray attenuation effect has been considered in their imaging model, which is helpful in improving the reconstruction accuracy. Results: First, simulation experiments with cylinder phantoms were carried out to illustrate the validity of the proposed compensated method. The experimental results showed that the location error of the compensated algorithm was smaller than that of the uncompensated method. The permissible region strategy was applied and reduced the reconstruction error to less than 2 mm. The robustness and stability were then evaluated from different view numbers, different regularization parameters, different measurement noise levels, and optical parameters mismatch. The reconstruction results showed that the settings had a small effect on the reconstruction. The nonhomogeneous phantom simulation was also carried out to simulate a more complex experimental situation and evaluated their proposed method. Second, the physical cylinder phantom experiments further showed similar results in their prototype XLCT system. With the discussion of the above experiments, it was shown that the proposed method is feasible to the general case and actual experiments. Conclusions: Utilizing numerical simulation and physical experiments, the authors demonstrated the validity of the new cone beam XLCT method. Furthermore, compared with the previous narrow beam XLCT, the cone beam XLCT could more fully utilize the x-ray dose and the scanning time would be shortened greatly. The study of both simulation experiments and physical phantom experiments indicated that the proposed method was feasible to the general case and actual experiments.

60 APPLIED LIFE SCIENCES↗

On the applicability of one- and many-electron quantum chemistry models for hydrated electron clusters

We evaluate the applicability of a hierarchy of quantum models in characterizing the binding energy of excess electrons to water clusters. In particular, we calculate the vertical detachment energy of an excess electron from water cluster anions with methods that include one-electron pseudopotential calculations, density functional theory (DFT) based calculations, and ab initio quantum chemistry using MP2 and eom-EA-CCSD levels of theory. The examined clusters range from the smallest cluster size (n = 2) up to nearly nanosize clusters with n = 1000 molecules. The examined cluster configurations are extracted from mixed quantum-classical molecular dynamics trajectories of cluster anions with n = 1000 water molecules using two different one-electron pseudopotenial models. We find that while MP2 calculations with large diffuse basis set provide a reasonable description for the hydrated electron system, DFT methods should be used with precaution and only after careful benchmarking. Strictly tested one-electron psudopotentials can still be considered as reasonable alternatives to DFT methods, especially in large systems. The results of quantum chemistry calculations performed on configurations, that represent possible excess electron binding motifs in the clusters, appear to be consistent with the results using a cavity structure preferring one-electron pseudopotential for the hydrated electron, while they are in sharp disagreement with the structural predictions of a non-cavity model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards quantifying the role of exact exchange in the prediction hydrogen bond spin-spin coupling constants involving fluorine

The effect of a fraction of Hartree-Fock exchange on the calculated spin-spin coupling constants involving fluorine through a hydrogen bond is analyzed in detail. Coupling constants calculated using wavefunction methods are revisited in order to get high-level calculations using the same basis set. Accurate MCSCF results are obtained using an additive approach. These constants and their contributions are used as a reference for density functional calculations. Within the density functional theory, the Hartree-Fock exchange functional is split in short- and long-range using a modified version of the Coulomb-attenuating method with the SLYP functional as well as with the original B3LYP. Results support the difficulties for calculating hydrogen bond coupling constants using density functional methods when fluorine nuclei are involved. Coupling constants are very sensitive to the Hartree-Fock exchange and it seems that, contrary to other properties, it is important to include this exchange for short-range interactions. Best functionals are tested in two different groups of complexes: those related with anionic clusters of type [F(HF){sub n}]{sup −} and those formed by difluoroacetylene and either one or two hydrogen fluoride molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗