Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Design and Test of a Liquid Oxygen / Liquid Methane Thruster with Cold Helium Pressurization Heat Exchanger

A liquid oxygen / liquid methane 2,000 lbf thruster was designed and tested in conjuction with a nozzle heat exchanger for cold helium pressurization. Cold helium pressurization systems offer significant spacecraft vehicle dry mass savings since the pressurant tank size can be reduced as the pressurant density is increased. A heat exchanger can be incorporated into the main engine design to provide expansion of the pressurant supply to the propellant tanks. In order to study the systems integration of a cold-helium pressurization system, a 2,000 lbf thruster with a nozzle heat exchanger was designed for integration into the Project Morpheus vehicle at NASA Johnson Space Center. The testing goals were to demonstrate helium loading and initial conditioning to low temperatures, high-pressure/low temperature storage, expansion through the main engine heat exchanger, and propellant tank injection/pressurization. The helium pressurant tank was an existing 19 inch diameter composite-overwrap tank, and the targert conditions were 4500 psi and -250 F, providing a 2:1 density advantage compared to room tempatrue storage. The thruster design uses like-on-like doublets in the injector pattern largely based on Project Morpheus main engine hertiage data, and the combustion chamber was designed for an ablative chamber. The heat exchanger was installed at the ablative nozzle exit plane. Stand-alone engine testing was conducted at NASA Stennis Space Center, including copper heat-sink chambers and highly-instrumented spoolpieces in order to study engine performance, stability, and wall heat flux. A one-dimensional thermal model of the integrated system was completed. System integration into the Project Morpheus vehicle is complete, and systems demonstrations will follow.

Melcher, John C.↗

Properties of a Novel Ion-Exchange Film

A new ion-exchange material (based on polyacrylic acid) and some of its analytical applications have been reported. This paper contains data on the ion-exchange properties of the film form of the material and its potential application to the decontamination of waste water and drinking water. The film has a high exchange capacity of 5 to 6 meq/g and a pK(sub a) of 5.7. The calcium form is the most effective for removing metal ions from solution, and the optimum pH range is between 5 and 7. The exchange rates are slower for the film than for bead and powder forms of the ion-exchange material; otherwise, the properties are similar. The film is effective when hard water solutions are employed and also when metal ions are in the complex matrix of waste water from electroplating. The film can be used in flow systems having a flow channel large enough to allow passage of turbid solutions.

Street, Kenneth W.↗

Controllable Multi-Functional Heat Exchanger for Space Applications

Team Spacering will design SpaceRing, a cooling and waste heat recycling system that addresses NASA’s interest for a cooling and power-generating unit in its prototype deep space habitat[1]. The merits of this system are as follows: - Controllable cooling is critical in maintaining a habitable environment and in the functionality of life support systems, powering electronics and other devices in a spacecraft. - Power is expensive to produce in a space environment. Converting wasted thermal energy into electricity will save energy and money for the space station. Space habitation is a highly complex endeavor. Consequently, the SpaceRing must adhere to additional constraints, which include: - Lack of natural fluid or gas convection due to micro-gravity environment - Limited range for heat source and cold sink temperature - Subject to high fluctuations of incoming thermal energy - Minimal weight due to the high cost of transporting items into space After consulting with NASA and experts in thermal studies, several design objectives were identified and are listed below in order of importance: - High cooling capacity - Reliable safety control and alert system - Maximization of energy generation from wasted heat - Optimization of cooling capability and power generation - Long operational life and minimization of maintenance In space, conventional cooling systems utilize passive heat pipe systems for small-scale heat rejection and pumped pipes with heat exchangers for large-scale heat rejection. Thermal power generation in space is mainly achieved by using thermoelectric material that produces electric energy from temperature differentials. We propose a design that combines cooling and thermoelectric power generation. Using a hot pipe connected to a heat source, a cold pipe connected to a radiator, a heat exchanger in contact with both pipes, and a pump in each pipe to move the fluid, we make an active cooling system. The thermoelectric material is inserted in the heat exchanger between the hot and cold pipes to extract energy from the maximum temperature difference coming from the two pipes. It also provides controllable cooling capacity through the use of the thermoelectric material as cooling modules. We have tested our system under target heat source and sink conditions and measured the temperatures and flow rates. Our preliminary results are promising, demonstrating the output of 25 Watts of power on average. We are in the process of running control tests to compare the heat transfer performance without the thermoelectric generators, which is vital in determining whether or not the generators introduce an unacceptable amount of thermal resistance. While some control tests have been run already, the results have been noisy. We have modified our testing environment and data acquisition methods to allow for simple comparison between the control test results and thermoelectric performance results. Lastly, we have modified the heat exchanger design slightly to include acrylic baffles. This will allow the heat to flow through the heat exchanger more efficiently. We have presented our preliminary results to NASA and will deliver the final product by the end of May 2014.

Lee Xiong↗

Structures of G [alpha [superscript i1]] Bound to a GDP-Selective Peptide Provides Insight into Guanine Nucleotide Exchange

Heterotrimeric G proteins are molecular switches that regulate numerous signaling pathways involved in cellular physiology. This characteristic is achieved by the adoption of two principal states: an inactive, GDP bound state and an active, GTP bound state. Under basal conditions, G proteins exist in the inactive, GDP bound state; thus, nucleotide exchange is crucial to the onset of signaling. Despite our understanding of G protein signaling pathways, the mechanism of nucleotide exchange remains elusive. We employed phage display technology to identify nucleotide state-dependent G{alpha} binding peptides. Herein, we report a GDP-selective G{alpha} binding peptide, KB-752, that enhances spontaneous nucleotide exchange of G{alpha}{sub i} subunits. Structural determination of the G{alpha}{sub i1}/peptide complex reveals unique changes in the G{alpha} switch regions predicted to enhance nucleotide exchange by creating a GDP dissociation route. Our results cast light onto a potential mechanism by which G{alpha} subunits adopt a conformation suitable for nucleotide exchange.

59 BASIC BIOLOGICAL SCIENCES↗

Emittance and Phase Space Exchange

Alternative chicane-type beam lines are proposed for exact emittance exchange between horizontal phase space (x; x{prime}) and longitudinal phase space (z; {delta}). Methods to achieve exact phase space exchanges, i.e. mapping x to z, x{prime} to {delta}, z to x and {delta} to x{prime} are suggested. Methods to mitigate the thick-lens effect of the transverse cavity on emittance exchange are discussed. Some applications of the phase space exchanger and the feasibility of an emittance exchange experiment with the proposed chicane-type beam line at SLAC are discussed.

43 PARTICLE ACCELERATORS↗

Solid oxide fuel cell power plant having a fixed contact oxidation catalyzed section of a multi-section cathode air heat exchanger

The multi-section cathode air heat exchanger (102) includes at least a first heat exchanger section (104), and a fixed contact oxidation catalyzed section (126) secured adjacent each other in a stack association. Cool cathode inlet air flows through cool air channels (110) of the at least first (104) and oxidation catalyzed sections (126). Hot anode exhaust flows through hot air channels (124) of the oxidation catalyzed section (126) and is combusted therein. The combusted anode exhaust then flows through hot air channels (112) of the first section (104) of the cathode air heat exchanger (102). The cool and hot air channels (110, 112) are secured in direct heat exchange relationship with each other so that temperatures of the heat exchanger (102) do not exceed 800.degree. C. to minimize requirements for using expensive, high-temperature alloys.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal-Hydraulic Performance of Wavy-Fin Heat Exchangers Under Dehumidifying Condition

Condensate accumulation on the heat exchangers has been identified as a critical problem for evaporators operating below the dew point temperature. An experimental study has been conducted to investigate the thermal-hydraulic performance of wavy fin heat exchangers under dehumidifying operating conditions. The relative comparison of pressure drop and heat transfer rate has been made at different inlet flow rates considering heat exchanger characteristics such as fin density and flow depth. The relative contribution of sensible and latent capacity to the total heat exchanger’s capacity has been investigated at different flow rates. The phenomena of condensate carry-over has been investigated qualitatively based on observation. Towards the end the impact of fin density on heat transfer rate and pressure drop for for fully and partially wet heat exchangers has been compared.

Nawaz, Kashif↗

Thermal-Hydraulic Performance of Wavy-Fin Heat Exchanger Under Dehumidifying Condition

Condensate accumulation on the heat exchangers has been identified as a critical problem for evaporators operating below the dew point temperature. An experimental study has been conducted to investigate the thermal-hydraulic performance of wavy fin heat exchangers under dehumidifying operating conditions. The relative comparison of pressure drop and heat transfer rate has been made at different inlet flow rates considering heat exchanger characteristics such as fin density and flow depth. The relative contribution of sensible and latent capacity to the total heat exchanger's capacity has been investigated at different flow rates. The phenomena of condensate carry-over has been investigated qualitatively based on observation. Towards the end the impact of fin density on heat transfer rate and pressure drop for for fully and partially wet heat exchangers has been compared.

Nawaz, Kashif↗

System including a direct contact desublimating heat exchanger for reducing fouling

A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through other devices for performing a unit operation, and the devices for performing a unit operation may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the devices for performing a unit operation. The parallel streams of differing temperature may be sent to a mixing chamber. A mixed stream of uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.

Baxter, Larry↗

System with a direct contact desublimating heat exchanger and temperature regulation

A process to prevent fouling using a desublimating heat exchanger is disclosed. An outlet stream from the desublimating heat exchanger may be split into a plurality of parallel streams. The parallel streams may be sent through a plurality of discrete unit operations, and the unit operations may change the temperature of at least one of the parallel streams. Parallel streams of differing temperature may emerge from the unit operations. The parallel streams which are of a similar temperature may be mixed to form a warm stream and a cool stream. The warm stream and the cool stream may be sent to a mixing chamber. A mixed stream of substantially uniform temperature may emerge from the mixing chamber, and the mixed stream may be recycled back to the desublimating heat exchanger. The mixing chamber may be separate from the desublimating heat exchanger, or the parallel streams of differing temperature may be mixed in the desublimating heat exchanger.

42 ENGINEERING↗

Optimization of Refrigerant Compositions for Low-GWP Refrigerant Mixtures Using Segment-by-segment Heat Exchanger and Detailed System Models

The recently introduced hydrofluoroolefin (HFO) refrigerants, including R1234yf and R1234ze(E), have significantly lower global warming potentials (GWPs) than traditional hydrofluorocarbon (HFC) refrigerants like R410A. However, prior tests show that direct drop-in of pure R1234yf or R1234ze(E) into equipment designed for R410A results in a decrease in heat exchanger capacity and the system coefficient of performance. The primary reason is the lower in-tube heat transfer performance of R1234yf and R1234ze(E) compared with that of R410A. To address this issue, previous studies have mixed the mildly flammable HFC R32 with HFOs to improve system performance, with HFC R125 also added to suppress flammability. Previous studies selected compositions based on simple cycle analyses and did not consider modifications of the heat exchanger circuitry configuration to adapt to the new refrigerants. This study presents a novel multi-objective optimization approach to design a refrigerant composition that maximizes energy efficiency within flammability and GWP limits. The approach in this work simultaneously optimizes mixture composition and heat exchanger circuitry configuration. A case study on a rooftop unit indicates that, compared with mixture-only optimization, simultaneous optimization of mixture and heat exchanger circuitry yields a 5.9% improvement in cycle efficiency and a 48.6% reduction in refrigerant flammability with a GWP of 268. Circuitry optimization using refrigerants with different temperature glides shows that the larger the temperature glide is, the larger EER improvement is obtained. The results show that zeotropic blends with a large temperature glide are more sensitive to the refrigerant circuitry than pure refrigerants and may suffer significant performance degradation with subpar heat exchanger circuitry design. The proposed optimization approach is generally applicable to mixtures with any number of components. Using this approach to design a HVAC system can yield higher system efficiency within flammability and GWP constraints.

Li, Zhenning↗

Polymer film heat exchanger sealing system and method

A method of manufacturing a heat exchanger array that includes stacking a plurality of heat exchanger units in an aligned configuration with respective first ports of the plurality of heat exchanger units aligned. The method can further include generating heat in the first coupling elements at the same time and at a temperature sufficient to generate a first plurality of respective couplings between adjacent sheets of adjacent heat exchanger units about adjacent first ports and without a coupling being generated between the first and second sheets of a given heat exchanger unit.

Rutkowski, Adam↗

Compliant heat exchangers, heat pipes and methods for making same

A method for fabricating heat exchangers using additive manufacturing technologies. Additive manufacturing enables the manufacture of heat exchangers with complex geometries and/or with internal and external integral surface features. Additive manufacture also facilitates the manufacture of heat exchangers with regional variations, such as changes in size, shape and surface features. In one embodiment, the present invention provides a heat exchanger with a helicoidal shape that provides axial elastic compliance. In one embodiment, the internal channel of the heat exchanger varies along its length. The internal channel may have a cross-sectional area that increases progressively from one end to the other. In one embodiment, the external shape of the tubular structure may be non-circular to optimize heat transfer with an external heat transfer fluid. In one embodiment, the present invention provides a heat pipe with an internal wicking structure formed as an integral part of the additive manufacturing process.

Lara-Curzio, Edgar↗

Refractory high entropy alloy compact heat exchanger

Several innovative technologies, including pressure-drop minimization, advanced refractory high entropy alloys, and advanced manufacturing can provide a compact heat exchanger that extends the state-of-the-art heat-exchanger operating range. The compact heat exchanger can reduce pressure drop losses by 100 to 500%, while retaining most of the heat transfer. The compact heat exchanger can be fabricated from refractory high entropy alloys that have favorable corrosion, thermal fatigue, and creep properties at high temperatures and pressures. Therefore, the compact heat exchanger using high entropy alloys can operate at >800° C. and 80 bars.

Kustas, Andrew↗

Polymers having stable cationic pendant groups for use as anion exchange membranes

Poly(aryl alkylene) polymers or poly(aryl-crown ether-alkylene) polymers with pendant cationic groups are provided which have an alkaline-stable cation, such as imidazolium, introduced into a rigid aromatic polymer backbone free of ether bonds. Hydroxide exchange membranes or hydroxide exchange ionomers formed from these polymers exhibit superior chemical stability, hydroxide conductivity, decreased water uptake, good solubility in selected solvents, and improved mechanical properties in an ambient dry state as compared to conventional hydroxide exchange membranes or ionomers. Hydroxide exchange membrane fuel cells and hydroxide exchange membrane electrolyzers comprising the poly(aryl alkylene) polymers or poly(aryl-crown ether-alkylene) polymers with pendant cationic groups exhibit enhanced performance and durability at relatively high temperatures.

Yan, Yushan↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Experimental and numerical investigation on air-side performance of fin-and-tube heat exchangers with various fin patterns

Air-side heat transfer and friction characteristics of five kinds of fin-and-tube heat exchangers, with the number of tube rows (N = 12) and the diameter of tubes (D{sub o} = 18 mm), have been experimentally investigated. The test samples consist of five types of fin configurations: crimped spiral fin, plain fin, slit fin, fin with delta-wing longitudinal vortex generators (VGs) and mixed fin with front 6-row vortex-generator fin and rear 6-row slit fin. The heat transfer and friction factor correlations for different types of heat exchangers were obtained with the Reynolds numbers ranging from 4000 to 10000. It was found that crimped spiral fin provides higher heat transfer and pressure drop than the other four fins. The air-side performance of heat exchangers with the above five fins has been evaluated under three sets of criteria and it was shown that the heat exchanger with mixed fin (front vortex-generator fin and rear slit fin) has better performance than that with fin with delta-wing vortex generators, and the slit fin offers best heat transfer performance at high Reynolds numbers. Based on the correlations of numerical data, Genetic Algorithm optimization was carried out, and the optimization results indicated that the increase of VG attack angle or length, or decrease of VG height may enhance the performance of vortex-generator fin. The heat transfer performances for optimized vortex-generator fin and slit fin at hand have been compared with numerical method. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fouling modeling and prediction approach for heat exchangers using deep learning

In this article, we develop a generalized and scalable statistical model for accurate prediction of fouling resistance using commonly measured parameters of industrial heat exchangers. This prediction model is based on deep learning where a scalable algorithmic architecture learns non-linear functional relationships between a set of target and predictor variables from large number of training samples. Here, the efficacy of this modeling approach is demonstrated for predicting fouling in an analytically modeled cross-flow heat exchanger, designed for waste heat recovery from flue-gas using room temperature water. The performance results of the trained models demonstrate that the mean absolute prediction errors are under 10 –4 KW –1 for flue-gas side, water side and overall fouling resistances. The coefficients of determination (R 2 ), which characterize the goodness of fit between the predictions and observed data, are over 99%. Even under varying levels of measurement noise in the inputs, we demonstrate that predictions over an ensemble of multiple neural networks achieves better accuracy and robustness to noise. We find that the proposed deep-learning fouling prediction framework learns to follow heat exchanger flow and heat transfer physics, which we confirm using locally interpretable model agnostic explanations around randomly selected operating points. Overall, we provide a robust algorithmic framework for fouling prediction that can be generalized and scaled to various types of industrial heat exchangers.

42 ENGINEERING↗