Energy-efficient modification of reduction-melting for lead recovery from cathode ray tube funnel glass

Highlights: • We recovered Pb from cathode ray tube funnel glass using reduction melting process. • We modified the melting process to achieve Pb recovery with low energy consumption. • Pb in the funnel glass is efficiently recovered at 1000 °C by adding Na{sub 2}CO{sub 3}. • Pb remaining in the glass after reduction melting is extracted with 1 M HCl. • 98% of Pb in the funnel glass was recovered by reduction melting and HCl leaching. - Abstract: Lead can be recovered from funnel glass of waste cathode ray tubes via reduction melting. While low-temperature melting is necessary for reduced energy consumption, previously proposed methods required high melting temperatures (1400 °C) for the reduction melting. In this study, the reduction melting of the funnel glass was performed at 900–1000 °C using a lab-scale reactor with varying concentrations of Na{sub 2}CO{sub 3} at different melting temperatures and melting times. The optimum Na{sub 2}CO{sub 3} dosage and melting temperature for efficient lead recovery was 0.5 g per 1 g of the funnel glass and 1000 °C respectively. By the reduction melting with the mentioned conditions, 92% of the lead in the funnel glass was recovered in 60 min. However, further lead recovery was difficult because the rate of the lead recovery decreased as with the recovery of increasing quantity of the lead from the glass. Thus, the lead remaining in the glass after the reduction melting was extracted with 1 M HCl, and the lead recovery improved to 98%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of proton irradiation on conductivity and deep level defects in β-Ga 2 O 3

Single crystalline bulk and epitaxially grown gallium oxide (β–Ga 2 O 3 ) was irradiated by 0.6 and 1.9 MeV protons to doses ranging from 5 × 10 9 to 6 × 10 14 cm -2 in order to study the impact on charge carrier concentration and electrically active defects. Samples irradiated to doses at or above 2 × 10 13 cm -2 showed a complete removal of free charge carriers in their as-irradiated state, whereas little or no influence was observed below doses of 6 × 10 12 cm -2 . From measurements at elevated temperatures, a thermally activated recovery process is seen for the charge carriers, where the activation energy for recovery follow a second-order kinetics with an activation energy of ~1.2 eV. Combining the experimental results with hybrid functional calculations, we propose that the charge carrier removal can be explained by Fermi-level pinning far from the conduction band minimum (CBM) due to gallium interstitials (Ga i ), vacancies (V Ga ), and antisites (Ga O ), while migration and subsequent passivation of V Ga via hydrogen-derived or V O defects may be responsible for the recovery. Following the recovery, deep level transient spectroscopy (DLTS) reveals generation of two deep levels, with energy positions around 0.75 and 1.4 eV below the CBM. Of these two levels, the latter is observed to disappear after the initial DLTS measurements, while the concentration of the former increases. Here, we discuss candidate possibilities and suggest that the origins of these levels are more likely due to a defect complex than an isolated point defect.

36 MATERIALS SCIENCE↗

Toward Enhancing Wastewater Treatment with Resource Recovery in Integrated Assessment and Computable General Equilibrium Models

Sustainable water management is essential to increasing water availability and decreasing water pollution. The wastewater sector is expanding globally and beginning to incorporate technologies that recover nutrients from wastewater. Nutrient recovery increases energy consumption but may reduce the demand for nutrients from virgin sources. We estimate the increase in annual global energy consumption (1,100 million GJ) and greenhouse gas emissions (84 million t CO2e) for wastewater treatment in the year 2030 compared to today’s levels to meet sustainable development goals. To capture these trends, integrated assessment and computable general equilibrium models that address the energy-water nexus must evolve. We reviewed 16 of these models to assess how well they capture wastewater treatment plant energy consumption and GHG emissions. Only three models include biogas production from the wastewater organic content. Four explicitly represent energy demand for wastewater treatment, and eight include explicit representation of wastewater treatment plant greenhouse gas emissions. Of those eight models, six models quantify methane emissions from treatment, five include representation of emissions of nitrous oxide, and two include representation of emissions of carbon dioxide. Our review concludes with proposals to improve these models to better capture the energy-water nexus associated with the evolving wastewater treatment sector.

42 ENGINEERING↗

A multifractal approach to space-filling recovery for PET quantification

Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.

60 APPLIED LIFE SCIENCES↗

TAS::89 0927::TAS RECOVERY - The Lean Green Energy Controller Machine

Achieving efficiency improvements and providing demand-response programs have been identified as key elements of our national energy initiative. The residential market is the largest, yet most difficult, segment to engage in efforts to meet these objectives. This project developed Energy Management System that engages the consumer and enables Smart Grid services, applications, and business processes to address this need. Our innovative solution provides smart controller providing dynamic optimization of energy consumption for the residential energy consumer. Our solution extends the technical platform to include a cloud based Internet of Things (IoT) aggregation of data sensors and actuators the go beyond energy management and extend to life style services provided through compelling mobile and console based user experiences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Estimating the Impact of Residual Value for Electricity Generation Plants on Capital Recovery, Levelized Cost of Energy, and Cost to Consumers

There is often a benefit to continue operating electricity generating assets after their initial contracts expire. This report discusses these benefits and associated risks, using data and illustrative calculations. The key findings are: the realized operational lives of generation technologies before retirement are typically much longer than typical measures of economic lives. The cost impact of a life extension can be comparable to the impact of other factors considered for generation investment decisions, and suggests that R&D and commercial efforts to extend generator life may be valuable. Refurbishment has a useful and economic role, but the option is often neglected during initial investment. Estimating follow-on value at the time of the original investment is complex and often neglected, but may be valuable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inertial fusion energy power reactor fuel recovery system

A conceptual design is proposed to support the recovery of un-expended fuel, ash, and associated post-detonation products resident in plasma exhaust from a {approx}2 GWIFE direct drive power reactor. The design includes systems for the safe and efficient collection, processing, and purification of plasma exhaust fuel components. The system has been conceptually designed and sized such that tritium bred within blankets, lining the reactor target chamber, can also be collected, processed, and introduced into the fuel cycle. The system will nominally be sized to process {approx}2 kg of tritium per day and is designed to link directly to the target chamber vacuum pumping system. An effort to model the fuel recovery system (FRS) using the Aspen Plus engineering code has commenced. The system design supports processing effluent gases from the reactor directly from the exhaust of the vacuum pumping system or in batch mode, via a buffer vessel in the Receiving and Analysis System. Emphasis is on nuclear safety, reliability, and redundancy as to maximize availability. The primary goal of the fuel recovery system design is to economically recycle components of direct drive IFE fuel. The FRS design is presented as a facility sub-system in the context of supporting the larger goal of producing safe and economical IFE power. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Life cycle assessment of urban waste management: Energy performances and environmental impacts. The case of Rome, Italy

Landfilling is nowadays the most common practice of waste management in Italy in spite of enforced regulations aimed at increasing waste pre-sorting as well as energy and material recovery. In this work we analyse selected alternative scenarios aimed at minimizing the unused material fraction to be delivered to the landfill. The methodological framework of the analysis is the life cycle assessment, in a multi-method form developed by our research team. The approach was applied to the case of municipal solid waste (MSW) management in Rome, with a special focus on energy and material balance, including global and local scale airborne emissions. Results, provided in the form of indices and indicators of efficiency, effectiveness and environmental impacts, point out landfill activities as the worst waste management strategy at a global scale. On the other hand, the investigated waste treatments with energy and material recovery allow important benefits of greenhouse gas emission reduction (among others) but are still affected by non-negligible local emissions. Furthermore, waste treatments leading to energy recovery provide an energy output that, in the best case, is able to meet 15% of the Rome electricity consumption.

54 ENVIRONMENTAL SCIENCES↗

A review on technological options of waste to energy for effective management of municipal solid waste

Highlights: • The current status, options and challenges of WTE techniques were analysed. • Incineration is the most widely used WTE technology in the developed countries. • Landfilling is the most common practice of MSWM in developing countries. • Approximately 50 million tonnes of methane is emitted annually from landfills. • WTE will ensure both the energy security and environmental protection. - Abstract: Approximately one-fourth population across the world rely on traditional fuels (kerosene, natural gas, biomass residue, firewood, coal, animal dung, etc.) for domestic use despite significant socioeconomic and technological development. Fossil fuel reserves are being exploited at a very fast rate to meet the increasing energy demands, so there is a need to find alternative sources of energy before all the fossil fuel reserves are depleted. Waste to energy (WTE) can be considered as a potential alternative source of energy, which is economically viable and environmentally sustainable. The present study reviewed the current global scenario of WTE technological options (incineration, pyrolysis, gasification, anaerobic digestion, and landfilling with gas recovery) for effective energy recovery and the challenges faced by developed and developing countries. This review will provide a framework for evaluating WTE technological options based on case studies of developed and developing countries. Unsanitary landfilling is the most commonly practiced waste disposal option in the developing countries. However, developed countries have realised the potential of WTE technologies for effective municipal solid waste management (MSWM). This review will help the policy makers and the implementing authorities involved in MSWM to understand the current status, challenges and barriers for effective management of municipal solid waste. This review concluded WTE as a potential renewable source of energy, which will partly meet the energy demand and ensure effective MSWM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INFORMATION: Audit Report on "Accounting and Reporting for the American Recovery and Reinvestment Act by the Department of Energy's Funding Recipients"

The American Recovery and Reinvestment Act of 2009 (Recovery Act) was established to jumpstart the U.S. economy, create or save millions of jobs, and invest in the Nation's energy future. The Department of Energy received approximately $37 billion through the Recovery Act to support a variety of science, energy and environmental initiatives. The Office of Management and Budget (OMB) issued guidance for carrying out stimulus-related activities which requires, among other things, that recipients ensure funds provided by the Recovery Act are clearly distinguishable from non-Recovery Act funds in all reporting systems and that recipients' actions are transparent to the public. To meet these requirements, the Department's recipients must clearly and accurately track and report on 18 separate data elements. In addition, the Department was to develop and implement a process to ensure that recipient information reported to the public was free from material omissions and significant reporting errors. Our recent report (OAS-RA-10-01, October 2009) noted that the Department had developed a quality assurance process to facilitate the quarterly reviews of recipient data and planned to test it during the first quarterly reporting cycle. To determine whether the Department's quality assurance process was effective, we examined information reported by recipients of Departmental funding as of September 30, 2009. We also sought to determine whether the Department's prime contractors were prepared to track and report on Recovery Act activities. The Department had taken a number of actions designed to ensure the accuracy and transparency of reported Recovery Act results. This process identified potential anomalies with information reported by 1,113 of 2,038, or 55 percent of recipients. We view the Department's data quality assurance efforts as both timely and significant. As noted by our audit testing, however, opportunities exist to strengthen the process. In particular: (1) Site officials did not always ensure that anomalies, once identified during the quality assurance process, were actually resolved. For example, the Department's process identified that about 740 of the approximately 10,000 jobs reported in the first quarter of Fiscal Year 2010 as created/retained were for projects reported as having no funds spent. Although these problems were referred to site officials for follow-up and/or correction, the information was never actually changed; (2) The Department did not always utilize the correct basis when evaluating the accuracy of 'funds provided' data submitted by grant recipients. For example, in its analysis process, the Department used data reflecting 'funds obligated' rather than the correct amount of 'total grant awards'. This generated a number of potential false positives; and, (3) Duplicate reports by certain recipients, resulting in overstatements of as much as $137 million of the more than $18 billion obligated, were not corrected. We observed that the Department had taken prompt action to ensure that its prime facility management contractors could properly report Recovery Act information. Notably, the seven contractors in this category included in our review had modified their accounting systems, as necessary, to ensure that they could accurately track and report on Recovery Act activities. The systems at each of these entities had been restructured so that they: (i) could separate Recovery Act and non-Recovery Act funds; and, (ii) had adequate processing capacity to handle the projected increase in transactions. We found the Department's decision to limit its reviews to the four elements that it considered to be critical (award amount, invoiced amount, jobs created/retained, and project status) to be reasonable. We concluded, however, other elements or dependent relationships should not be completely excluded from review. Beyond its initial development and implementation of its quality assurance process, the Department had taken steps to improve its ability to ensure that Recovery Act information was both accurate and transparent to the public. Specifically, officials changed the quality assurance plan based on initial data reviews. Department officials also informed us that they are in the process of updating their quality assurance process to meet new OMB requirements. For example, recent guidance directed agencies to focus on certain data elements, such as award number and recipient name, during their quality assurance reviews. In addition, subsequent to our review, the Department added two more data elements and comparisons to its quarterly assurance process, including an analysis of costs/expenditures and a comparison of the recipient reported project status to the Department's data contained in its financial system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A historical perspective of Global Warming Potential from Municipal Solid Waste Management

Highlights: • Five scenarios are compared based on different waste management systems from 1970 to 2010. • Technology development for incineration and vehicular exhaust system throughout the time period is considered. • Compared scenarios show continuous improvement regarding environmental performance of waste management system. • Energy and material recovery from waste account for significant savings of Global Warming Potential (GWP) today. • Technology development for incineration has played key role in lowering the GWP during past five decades. - Abstract: The Municipal Solid Waste Management (MSWM) sector has developed considerably during the past century, paving the way for maximum resource (materials and energy) recovery and minimising environmental impacts such as global warming associated with it. The current study is assessing the historical development of MSWM in the municipality of Aalborg, Denmark throughout the period of 1970 to 2010, and its implications regarding Global Warming Potential (GWP{sub 100}), using the Life Cycle Assessment (LCA) approach. Historical data regarding MSW composition, and different treatment technologies such as incineration, recycling and composting has been used in order to perform the analysis. The LCA results show a continuous improvement in environmental performance of MSWM from 1970 to 2010 mainly due to the changes in treatment options, improved efficiency of various treatment technologies and increasing focus on recycling, resulting in a shift from net emission of 618 kg CO{sub 2}-eq. tonne{sup −1} to net saving of 670 kg CO{sub 2}-eq. tonne{sup −1} of MSWM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benefits and Costs of Aggressive Energy Efficiency Programs and the Impacts of Alternative Sources of Funding: Case Study of Massachusetts

Increased interest by state (and federal) policymakers and regulatory agencies in pursuing aggressive energy efficiency efforts could deliver significant utility bill savings for customers while having long-term implications for ratepayers (e.g. potential rate impacts). Equity and distributional concerns associated with the authorized recovery of energy efficiency program costs may necessitate the pursuit of alternative program funding approaches. In 2008, Massachusetts passed the Green Communities Act which directed its energy efficiency (EE) program administrators to obtain all cost-effective EE resources. This goal has translated into achieving annual electric energy savings equivalent to a 2.4% reduction in retail sales from energy efficiency programs in 2012. Representatives of electricity consumer groups supported the new portfolio of EE programs (and the projected bill savings) but raised concerns about the potential rate impacts associated with achieving such aggressive EE goals, leading policymakers to seek out alternative funding sources which can potentially mitigate these effects. Utility administrators have also raised concerns about under-recovery of fixed costs when aggressive energy efficiency programs are pursued and have proposed ratemaking policies (e.g. decoupling) and business models that better align the utility's financial interests with the state's energy efficiency public policy goals. Quantifying these concerns and identifying ways they can be addressed are crucial steps in gaining the support of major stakeholder groups - lessons that can apply to other states looking to significantly increase savings targets that can be achieved from their own ratepayer-funded energy efficiency programs. We use a pro-forma utility financial model to quantify the bill and rate impacts on electricity customers when very aggressive annual energy efficiency savings goals ({approx}2.4%) are achieved over the long-term and also assess the impact of different cost recovery approaches that integrate alternative revenue sources. We also analyze alternative lost fixed cost recovery approaches to better understand how to mitigate the erosion of utility shareholder returns in states that have adopted (and achieved) very aggressive savings targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Effect of Annealing Conditions on Recovery of Lattice Damage in a High-Energy-Implanted 4H-SiC Superjunction PIN Diode

A high energy ion implantation system has been recently developed at the Tandem Van de Graaff facility at Brookhaven National Laboratory with tunable energy to 150 MeV capable of multi-step, deep implantation in 4H-SiC wafers with dopant atoms, such as B, P, Al, and N. Medium and high voltage devices with deep junctions can be fabricated using this system. Lattice strain introduced by the implantation process needs to be recovered and dopant atoms activated by appropriate annealing process as the device performance is strongly associated with the extent of recovery of the lattice. Using Synchrotron X-ray Rocking Curve Topography (SXRCT) and Reciprocal Space Mapping (RSM), the strain induced by high energy implantation of Al and N in 4H-SiC in different patterns are measured and mapped. It is observed that the strain levels correlate with the total fluence levels. PiN diodes fabricated on these implanted wafers were then annealed at temperatures ranging from 1700 °C to 2000 °C for 60 min. The SXRCT and RSM analysis of the annealed samples suggests that for the same annealing duration, higher temperature leads to better lattice recovery.

43 PARTICLE ACCELERATORS↗

Radiation damage and annealing of three coaxial n-type germanium detectors: Preparation for spaceflight missions to asteroid 16 Psyche and Mars’ moon Phobos

Three n-type high-purity germanium (HPGe) detectors were irradiated with protons at solar and galactic cosmic ray energies, with fluences corresponding to 3 years of exposure to the interplanetary radiation environment. Following 1 GeV proton irradiations (8x10 8 protons cm –2 ), annealing of the detectors at 105° and 115 °C resulted in full energy resolution recovery after 240 and 140 h of annealing, respectively. A second irradiation, consisting of 7.25x10 9 protons cm –2 with a solar-proton-like energy spectrum, resulted in full recovery within <316 h of annealing at 105 °C. Prior spaceflight experience raised concerns about annealing-induced leakage currents. During this study, one of the three detectors was annealed for a cumulative time of 57 days, and there was no evidence for increased leakage currents. However, gamma-ray photopeak detection efficiency was found to be strongly anti-correlated with cumulative anneal time for all three detectors. The energy- and time-dependence of the efficiency loss is consistent with the loss of active volume at the inner borehole, which we attribute to thermal diffusion of the lithium contact during annealing. The data collected during this study validate aspects of the design of two in-development planetary gamma-ray spectrometers; one to the asteroid (16) Psyche and one to Mars’ moon Phobos. The annealing strategy and operations concepts for these two instruments are informed by the results of this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sustainability metrics for assessing water resource recovery facilities of the future

Abstract The recovery of water, energy, and nutrients from water resource recovery facilities ( WRRF s) is needed to address significant global challenges, such as increasing water demand and decreasing availability of nonrenewable resources. To meet these challenges, innovative technological developments must lead to increased adoption of water and resource recovery processes, while addressing stakeholder needs (e.g., innovators, practitioners, regulators). A test bed network of over 90 partner facilities within the United States and abroad will help accelerate innovation and widespread adoption of novel processes through multiscale testing and demonstration of technologies. In this paper, we define a common set of environmental, economic, technical, and social performance metrics for innovative technologies, that will meet the needs of multiple stakeholders in the decision‐making process. These triple bottom line performance metrics can be used to track the sustainability of technologies in a consistent and transparent manner, while aiding the decision‐making process for WRRF s. Practitioner points The Facilities Accelerating Science and Technology (FAST) Water Network includes over 90 test bed facilities dedicated to accelerating innovation and adoption of water energy, and nutrient recovery systems. A common set of environmental, economic, technical, and social performance metrics should be measured and reported when a new technology is evaluated in the FAST Water Network. Performance metrics can aid sustainable decision‐making at WRRF, while meeting the needs of multiple stakeholders.

Cornejo, Pablo K.↗

Planning a Resilient Power Sector: Ensuring Reliable, Secure, Safe, and Affordable Electricity

Decision makers around the globe are exploring strategies to ensure the reliable, secure, safe, and affordable supply of electricity to power economic growth and achieve development goals. Vulnerabilities of the power sector to natural hazards (e.g., acts of nature, severe weather, and climate variabilities), technological hazards (e.g., accidents and system or structure failures), and threats or human-caused incidents (e.g., intentional cyber-attacks or acts of terror) can impede the provision of the energy services necessary to achieve these goals. Although decision makers cannot prevent an act of nature such as an earthquake, they can anticipate, prepare for, and adapt to potential vulnerabilities through planning. The purpose of power sector resilience planning is to identify vulnerabilities and devise strategies to mitigate them. This document reviews some of the hazards that power sectors face and how decision makers can plan to increase resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗