Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical Power System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Solid oxide fuel cell power system development

This report summarizes the progress made during this contractual period in achieving the goal of developing the solid oxide fuel cell (SOFC) cell and stack technology to be suitable for use in highly-efficient, economically-competitive, commercially deployed electrical power systems. Progress was made in further understanding cell and stack degradation mechanisms in order to increase stack reliability toward achieving a 4+ year lifetime, in cost reduction developments to meet the SECA stack cost target of $175/kW (in 2007 dollars), and in operating the SOFC technology in a multi-stack system in a real-world environment to understand the requirements for reliably designing and operating a large, stationary power system.

30 DIRECT ENERGY CONVERSION↗

Batteries Included: Top 10 Findings from Berkeley Lab Research on the Growth of Hybrid Power Plants in the United States

One of the most important electric power system trends of the 2010s was the rapid deployment of wind turbines and photovoltaic arrays, but a twist for the 2020s may be the rapid deployment of ‘hybrid’ generation resources. Hybrid power plants typically combine solar or wind (or other energy sources) with co-located storage. While hybridization helps to ease the challenge of balancing variable supply and demand, its relative novelty means that research is needed to facilitate integration and promote innovation. Combining the characteristics of multiple energy, storage, and conversion technologies poses complex questions for grid operations and economics. Project developers, system operators, planners, and regulators would benefit from better data, methods, and tools to estimate the costs, values, and system impacts of hybrid projects. This publication showcases some of Berkeley Lab’s robust research program intended to support private- and public-sector decision-making about hybrid plants in the United States. Our short briefing summarizes articles that we published between 2020 and 2022, links to the in-depth reports, and provides contact details for further engagement on the specific research topics: Growth: Developer interest in hybrid power plants is strong and growing Price vs. Value: PV+storage hybrids have low PPA prices and high value in some regions Market Drivers: Solar hybridization is driven by tax credits and other benefits Configuration Choices: Market prices have incentivized shorter duration batteries with PV Capacity Value: The capacity contribution of a hybrid is less than the sum of its parts Ancillary Services: AS markets are a valuable yet fleeting option for hybrids Market Participation: Hybrids can more flexibly engage with electricity markets Operations: The power system value of hybrids depends on how they are operated Distributed Hybrids: Growth of customer-sited PV+storage hybrids offers new opportunities Future Research: Where next? Priority areas for hybrid power research.

25 ENERGY STORAGE↗

Design and emplacement of an integrated lunar power system - Issues and concerns

Issues regarding the construction and operation of a stationary lunar surface power system that must be resolved in order to create a permanent manned presence on the moon are addressed. The issues considered include: (1) the centralization or decentralization of the electrical power system; (2) whether power transmission should be ac or dc; (3) what mix of power generating technology should be used; and (4) the physical interface requirements between the power-system hardware and the construction equipment to be used in placing the hardware on the lunar surface.

Sprouse, Kenneth M.↗

The impact of market design and clean energy incentives on strategic generation investments and resource adequacy in low-carbon electricity markets

Well-designed electricity markets play a crucial role in maintaining reliable electric power systems, which are critical in modern society. Here, this study examines the impact of different electricity market designs and clean energy incentive schemes on supporting renewable energy integration and achieving clean energy goals. To this end, we utilize a game-theoretical generation expansion planning model where generation companies make investment and retirement decisions to maximize their expected profit. The model is structured as an equilibrium problem with equilibrium constraints (EPEC) and solved using a diagonalization approach combined with progressive hedging. We analyze three types of electricity market designs: an energy-only market, a capacity market, and a clean energy market, and consider a wide range of market parameters resulting in 14 total scenarios. Wind and solar capacity comprise the majority of new investments in all considered scenarios, but the resultant system planning reserve margin (PRM) can differ significantly depending on market parameters. We also find that profit-driven investments lead to lower PRMs than a traditional system cost minimization approach. These individual scenario results further demonstrate how different market designs and clean energy incentive schemes may influence investor decision-making and impact resource adequacy throughout the clean energy transition.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MAFRIT (Multi-Area Frequency Response Integration Tool)

The Multi-Area Frequency Response Integration Tool (MAFRIT) is the only software tool of its kind that integrates primary frequency response (turbine governor control) with secondary frequency response (automatic generation control). It simulates the power system dynamic response in full time spectrum with variable time steps from millisecond to minutes to hours and days. Capable of simulating both normal and event conditions, this tool can represent real power system operations and thus evaluate the primary and secondary reserves adequacy. This unique interaction of a turbine governor model and a novel automatic generation control model places special emphasis on electric power systems with high penetrations of renewable generation.

Himanshu, Jain↗

Soyuz/ACRV accommodation study

Included is a set of viewgraphs that present the results of a study conducted at the LaRC Space Station Freedom Office at the request of the Space Station Freedom Level 1 Program Office and the JSC ACRV Project Office to determine the implications of accommodating two Soyuz TM spacecraft as Assured Crew Return Vehicles (ACRV) on the Space Station Freedom (SSF) at the Permanently Crewed Capability (PCC) stage. The study examined operational as well as system issues associated with the accommodation of the Soyuz for several potential configuration options. Operational issues considered include physical hardware clearances, worst case Soyuz departure paths, and impacts to baseline operations such as Pressurized Logistics Module (PLM) exchange, Space Station Remote Manipulator System (SSRMS) attachment, Extravehicular Activity (EVA), and automatic rendezvous and docking (AR&D). Systems impact analysis included determining differences between Soyuz interface requirements and SSF capabilities for the Electrical Power System (EPS), Thermal Control System (TCS), Communications and Tracking (C&T), Audio-Video Subsystem (A/V), Data Management System (DMS), and Environmental Control and Life Support System (ECLSS). Significant findings of this study have indicated that the current AV capability of the Soyuz will need to be increased to provide adequate departure clearances for a worst case escape from an uncontrolled SSF and that an interface element will be required to mate the Soyuz vehicles to station, provide for AR&D structural loads, and to house Soyuz-to-SSF system interfaces.

Cruz, Jonathan↗

The Second Assessment of the Effects of Climate Change on Federal Hydropower

Hydropower is a key contributor to the US renewable energy portfolio due to its established development history and the diverse benefits it provides to the electric power system. Ensuring the sustainable operation of existing hydropower facilities is of great importance to the US renewable energy portfolio and the reliability of electricity grid. As directed by Congress in Section 9505 of the SECURE Water Act (SWA) of 2009 (Public Law 111-11), the US Department of Energy (DOE), in consultation with the federal Power Marketing Administrations (PMAs) and other federal agencies, has prepared a second quinquennial report on examining the potential effects of climate change on water available for hydropower at federal facilities and on the marketing of power from these federal facilities. This Oak Ridge National Laboratory (ORNL) Technical Memorandum, referred to as the 9505 assessment, describes the technical basis for the report to Congress that was called for in the SWA. To evaluate the potential climate change effects on 132 federal hydropower plants across the entire US, a spatially consistent assessment approach is designed to enable an interregional comparison. This assessment uses a series of models and methods with different spatial resolutions to gradually downscale the global climate change signals into watershed-scale hydrologic projections to support hydropower impact assessment. A variety of historic meteorological and hydrologic observations, hydropower facility characteristics, and geospatial datasets is collected to support model development, calibration, and verification. Among most of the federal hydropower plants throughout the US, the most important climate change effect on hydrology is likely to be the trend toward earlier snowmelt and change of runoff seasonality. Under the projections of increasing winter/spring runoff and decreasing summer/fall runoff, water resource managers may need to consider different water use allocations. With the relatively large storage capacity in the most of the US federal hydropower reservoirs, the system is likely to be able to absorb part of the runoff variability and hence may continue to provide stable annual hydropower generation in the projected near-term and midterm future periods. Nevertheless, the findings are based on the assumption that there is no significant change in the future installed capacity and operation. The issues of aging infrastructures, competing water demand, and environmental requirements may reduce the system s ability to mitigate runoff variability and increase the difficulty of future operation. These issues are not quantitatively analyzed in this study. This study presents a regional assessment at each of the eighteen PMA study areas. This generalized approach allows for spatial consistency throughout all study areas, enabling policymakers to evaluate potential climate change impacts across the entire federal hydropower fleet. This effort is expected to promote better understanding of the sensitivity of federal power plants to water availability and provides a basis for planning future actions that will enable adaptation to climate variability and change.

13 HYDRO ENERGY↗

Number of lightning discharges causing damage to lightning arrester cables for aerial transmission lines in power systems

Damage by lightning discharges to lightning arrester cables for 110-175 kV aerial transmission lines is analyzed using data from power systems on incidents with aerial transmission lines over a ten year operating period (1997-2006). It is found that failures of lightning arrester cables occur when a tensile force acts on a cable heated to the melting point by a lightning current. The lightning currents required to heat a cable to this extent are greater for larger cable cross sections. The probability that a lightning discharge will develop decreases as the amplitude of the lightning current increases, which greatly reduces the number of lightning discharges which damage TK-70 cables compared to TK-50 cables. In order to increase the reliability of lightning arrester cables for 110 kV aerial transmission lines, TK-70 cables should be used in place of TK-50 cables. The number of lightning discharges per year which damage lightning arrester cables is lowered when the density of aerial transmission lines is reduced within the territory of electrical power systems. An approximate relationship between these two parameters is obtained.

42 ENGINEERING↗

Optimizing the location and configuration of disaster resilience hubs under transportation and electric power network failures

Natural disasters often result in failures of transportation network components and blackouts that imperil the wellbeing of vulnerable populations. In response to these events, resilience hubs have been proposed as a pre-disaster planning strategy to improve access to critical services. This paper introduces an optimization-based approach to locate and configure electric power-generating resilience hubs considering the possibility of failures in transportation and electric power systems. The model's objective is to identify hub locations and configurations that maximize transportation accessibility to the hubs and maximize the satisfaction of basic energy needs through hub-generated electric power. Besides a budget constraint, the model accounts for limits on the levels of hub energy generation vis-à-vis community energy demands, and on the transportation network distance of communities to hubs. Three heuristics are presented for the proposed planning problem. The first heuristic is a genetic algorithm (GA) with problem-specific solution generation procedures. The other two heuristics implement greedy search techniques. Numerical experiments were conducted, using data from rural Puerto Rico, to illustrate the application of the proposed model and heuristics, and examine their performance. In the numerical experiments, the GA heuristic found better solutions than the greedy heuristics. Additionally, design solutions consisting of spatially dispersed hubs with low energy generation capacity were better than solutions with spatially concentrated high-capacity hubs. Lastly, across a wide range of hub demand scenarios, only a small number of candidate hub locations consistently ranked among the best locations for establishing a hub.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Multi-Site Networked Hardware-in-Loop Platform for Evaluation of Interoperability and Distributed Intelligence at Grid-Edge

Electric power systems have experienced large increases in the number of intelligent, connected and controllable devices being deployed, leading to a high degree of distributed intelligence at the grid-edge. These devices, both utility-owned and consumer-owned, include but are not limited to: renewable generation sources, energy storage, remote switches, voltage regulators, and smart controllable loads such as electric vehicles. These new devices provide significant potential for increased operational flexibility that can be leveraged to achieve system reconfiguration, resiliency improvements, power quality improvements, and distribution system automation. However, there are two significant challenges that must be addressed before these assets can be leveraged for operations: interoperability and system level validation prior to deployment. Because of the complexity of distributed control systems, and their interactions with legacy centralized controls, a purely simulations-based approach for pre-deployment validation is not sufficient. It requires hardware-in-loop testing to emulate the operational hardware devices and evaluate their performance. Additionally, securely integrating multiple test facilities at utility operators and vendors might enable rapid scale-up of evaluation platforms, and remove the need for multiple expensive standalone installations. Presented in this paper, is the development of a multi-site evaluation platform that employs Advanced Distribution Management Systems (ADMS), distributed control devices, real-time hardware-in-loop assets, secure communication links, and protocol adapters. This platform uses standards-based approaches and open-source tools, and hence can serve as a template for other researchers and institutions to implement their multi-site evaluation frameworks for pre-deployment testing.

Essakiappan, Somasundaram↗

Thermal Design Challenges for In-Flight Exposure to an Electric Propulsion Plasma Plume Environment

The use of electric propulsion to carry out NASA in-space propulsion demands has been increasing. A big part of fulfilling this demand is the Power and Propulsion Element (PPE) for NASA's Lunar Gateway. When built, the PPE will have the largest electric propulsion system to ever fly on a spacecraft, which brings new and difficult challenges. The environment created by the electric propulsion system during on-orbit operation of the thrusters has been shown to be different than those measured during operation in terrestrial vacuum facilities. Understanding the on-orbit environment created by the thrusters and its impacts on the spacecraft is the goal of the Plasma Diagnostic Package (PDP). The PDP is a sensor package, which is being developed by NASA GRC (Glenn Research Center), to fly on the PPE. The PDP will measure different aspects of the thruster plume in order to develop higher fidelity modeling of EP (Electric Power) systems. In order to capture quality measurements of the plume the PDP will need to install sensors in close proximity of it. This poses several unique thermal design challenges. Some of these challenges include: the long duration exposure to plume induced heating, the effects of plume induced erosion and sputter deposition on thermal control surfaces, and the extreme environments of a cis-lunar orbit. This paper looks to define the thermal challenges, explain modeling techniques, and offer design solutions for unique challenges of the PDP mission.

Thermal↗

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics↗

Direct Current Arc-Flash Hazards of Solar Photovoltaic Systems

An arc-flash is a rapid release of thermal energy, pressure waves, and electromagnetic interference from a high-power electrical system, caused by such events as unintentional shorting or equipment malfunction. Arc-flashes are hazardous to people and equipment. Incident energy (IE) is a means of quantifying the degree of thermal hazard posed by an arc-flash event. The calculated IE value dictates what level of personal protective equipment (PPE) workers are required to wear when servicing equipment. Overly burdensome PPE may increase a worker’s discomfort and decrease dexterity, which could lead to unintentional shorting, while inadequate PPE also comes with increased safety risks. The majority of arc-flash research to date has focused on alternating current (ac) systems. For example, IE calculations and PPE for ac systems are relatively well understood and have been applied across many equipment types and voltages. IE calculation methodologies in ac systems are backed by a wide range of industry tests and are included in Institute of Electrical and Electronics Engineers (IEEE) and National Fire Protection Association (NFPA) standards. However, very little is known about direct current (dc) arc-flash and its hazards. This is a significant knowledge gap, as an increasing number of dc systems are being deployed: solar photovoltaic (PV) plants, battery storage, and electric vehicles and their charging infrastructure. The dc arc-flash hazard publications are rooted primarily in theory, and their IE calculation methods contradict each other. Insufficient knowledge and data are preventing the formation of industry consensus and standards around dc arc-flash hazard assessment. Here, this white paper highlights the current status and research opportunities for assessing arc-flash hazards in dc systems, with a focus on PV plants. The nonlinear current-voltage characteristics of PV modules make them unique in comparison to other linear dc sources, such as batteries. Also, PV equipment has rapidly evolved from 600 Vdc to 1,500 Vdc (in the United States), increasing potential arc-flash hazards. The operating regime of a PV-array within its I-V characteristic curve during an arc-flash event and the sustainability of arc-flash events in a utility-scale PV plant need to be investigated. Arc-flash experiments on a 1-MWdc nameplate capacity utility-owned ground-mount photovoltaic plant suggest that the PV array acts as a constant-current supply with currents near the short-circuit portion of the I-V characteristic curve of the array, with median arc voltage as 1/3 of the rated voltage. Various engineering software packages (CYME7 by EATON, PTW by SKM, ArcFlash™ by EasyPower, ETAP, and so on) have started offering dc arc-flash calculation features to estimate the risk of arc-flash in dc and PV systems. However, they are reliant on the same simplified arc-flash models, which contradict each other due to differences in assumptions such as characteristics of the power source, arc current, voltage and impedance, arc-operating regime, and so on. Physical arc-flash testing and improved physics-based modeling with correct assumptions representing practical scenarios are two methods to improve understanding and quantify the risks associated with dc arc-flash hazards. The results would inform development of a more accurate calculation procedure for IE and proper PPE levels.

14 SOLAR ENERGY↗

Space Station Photovoltaic power modules

Silicon cell Photovoltaic (PV) power modules are key components of the Space Station Electrical Power System (EPS) scheduled to begin deployment in 1994. Four PV power modules, providing 75 KWe of user ac power, form the cornerstone of the EPS; which is comprised of Photovoltaic (PV) power modules, Solar Dynamic (SD) power modules, and the Power Management and Distribution (PMAD) system. The PV modules are located on rotating outboard sections of the Space Station (SS) structure and each module incorporates its own nickel-hydrogen energy storage batteries, its own thermal control system, and some autonomous control features. The PV modules are a cost-effective and technologically mature approach for providing reliable SS electrical power and are a solid base for EPS growth, which is expected to reach 300 KWe by the end of the Space Station's 30-year design lifetime.

Tatro, Charles A.↗

Accelerating development of advanced inverters :

The high penetration of utility interconnected photovoltaic (PV) systems is causing heightened concern over the effect that variable renewable generation will have on the electrical power system (EPS). These concerns have initiated the need to amend the utility interconnection standard to allow advanced inverter control functionalities that provide: (1) reactive power control for voltage support, (2) real power control for frequency support and (3) better tolerance of grid disturbances. These capabilities are aimed at minimizing the negative impact distributed PV systems may have on EPS voltage and frequency. Unfortunately, these advanced control functions may interfere with island detection schemes, and further development of advanced inverter functions requires a study of the effect of advanced functions on the efficacy of antiislanding schemes employed in industry. This report summarizes the analytical, simulation and experimental work to study interactions between advanced inverter functions and anti-islanding schemes being employed in distributed PV systems.

Neely, Jason C.↗

Very low-power power supplies

Unit may be used in systems requiring milliwatt power for bias voltage functions and can be used as control mechanism for large electric power systems. Logic and energy storage techniques yield processing efficiencies of 1000 to 1 over conventional designs.

Roy, N. L.↗

Intelligent data reduction - A preliminary investigation

Research being undertaken to develop expert systems for reducing telemetry data from spacecraft is described. The use of the Hubble Space Telescope Electrical Power System as a testbed is examined. The Nickel Cadmium Battery Expert System is briefly addressed, and the I-DARE (Intelligent Data Reduction) prototype system is discussed.

Ford, Donnie R.↗