Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Progress on the Development of XRF Imaging and Analysis at the Siam Photon Laboratory

XRF imaging and analysis at the Siam Photon Laboratory have been recently developed for supporting various applications in x-ray micro analysis. An experimental setup for white beam x-ray fluorescent imaging has been installed at the beamline BL2 for elemental and quantitative analyses. A white micro beam of 163x170 {mu}m{sup 2}(FWHM) measured by wire scanning has been delivered to samples using a polycapillary x-ray half-lens. The fluorescent emissions of characteristic x-rays (1 keV and above) are detected by a Si-PIN detector. XRF imaging of Ni grids on supporting glass and XRF analysis on a trace-element standard were conducted for testing the apparatus. The test results on these samples as well as the necessary software developed for elemental identification and imaging are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Stability: Benefits from Concentrating on Basics

In recent years there has been a lot of activity aimed at producing smaller and more intense beams. However, experience has shown that with these beams the quality of the data obtained is highly sensitive to alignment issues, mechanical (in)stabilities, source instabilities, material choices and surface degradations of optical components. Over several years the ESRF has investigated many beamline optical components with the view to improve both beam and sample stability. The measures that have been taken to achieve these improvements are described together with possible improvements that could be envisaged in the future.

43 PARTICLE ACCELERATORS↗

The FERMI-Elettra FEL Photon Transport System

The FERMI-Elettra free electron laser (FEL) user facility is under construction at Sincrotrone Trieste (Italy), and it will be operative in late 2010. It is based on a seeded scheme providing an almost perfect transform-limited and fully spatially coherent photon beam. FERMI-Elettra will cover the wavelength range 100 to 3 nm with the fundamental harmonics, and down to 1 nm with higher harmonics. We present the layout of the photon beam transport system that includes: the first common part providing on-line and shot-to-shot beam diagnostics, called PADReS (Photon Analysis Delivery and Reduction System), and 3 independent beamlines feeding the experimental stations. Particular emphasis is given to the solutions adopted to preserve the wavefront, and to avoid damage on the different optical elements. Peculiar FEL devices, not common in the Synchrotron Radiation facilities, are described in more detail, e.g. the online photon energy spectrometer measuring shot-by-shot the spectrum of the emitted radiation, the beam splitting and delay line system dedicated to cross/auto correlation and pump-probe experiments, and the wavefront preserving active optics adapting the shape and size of the focused spot to meet the needs of the different experiments.

43 PARTICLE ACCELERATORS↗

A KB-Focusing Mirror Pair for a VUV-Raman Spectrometer at FLASH - Mirror Metrology and Ray Tracing Results

A plane mirror and two strongly curved plane elliptical mirrors comprising the refocusing system downstream the plane grating monochromator at FLASH in DESY have been characterized with the Nanometer Optical Component Measuring Machine at the BESSY-II Optics Laboratory of the Helmholtz Zentrum Berlin. Based on the measurement results the two elliptical cylinders were optimized by deterministic surface finishing technology (Ion Beam Finishing). The expected focusing performance was verified by ray tracings after each ion beam finish iteration using the measured topography results.

43 PARTICLE ACCELERATORS↗

X-ray and EUV Emission Studies of Copper Vacuum Spark Plasma

A vacuum spark system with a copper anode and electrode of gap 1.5 mm is investigated for the purpose of developing it as a possible radiation source for Next Generation Lithography (NGL). At discharge voltage in the range of 10 to 15 kV and an ambient pressure of about 10{sup -3} mbar, both X-ray (measured by PIN diode) and extreme ultraviolet, EUV (measured by SXUV5A with integrated filter) can be measured simultaneously when good pinching discharge as indicated by sharp dip in the waveform of the rate of current is achieved. For discharge with mild pinching, only EUV emission is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Characteristics Of An Intensity Modulated Advanced X-Ray Source (IMAXS) For Homeland Security Applications

X-ray cargo inspection systems for the detection and verification of threats and contraband must address stringent, competitive performance requirements. High x-ray intensity is needed to penetrate dense cargo, while low intensity is desirable to minimize the radiation footprint, i.e. the size of the controlled area, required shielding and the dose to personnel. In a collaborative effort between HESCO/PTSE Inc., XScell Corp., Stangenes Industries, Inc. and Rapiscan Laboratories, Inc., an Intensity Modulated Advanced X-ray Source (IMAXS) was designed and produced. Cargo inspection systems utilizing such a source have been projected to achieve up to 2 inches steel-equivalent greater penetration capability, while on average producing the same or smaller radiation footprint as present fixed-intensity sources. Alternatively, the design can be used to obtain the same penetration capability as with conventional sources, but reducing the radiation footprint by about a factor of three. The key idea is to anticipate the needed intensity for each x-ray pulse by evaluating signal strength in the cargo inspection system detector array for the previous pulse. The IMAXS is therefore capable of changing intensity from one pulse to the next by an electronic signal provided by electronics inside the cargo inspection system detector array, which determine the required source intensity for the next pulse. We report on the completion of a 9 MV S-band (2998 MHz) IMAXS source and comment on its performance.

07 ISOTOPE AND RADIATION SOURCES↗

Commissioning of Angle Dispersive X-ray Diffraction Beamline on Indus-2

An Angle dispersive x-ray diffraction (ADXRD) beamline on bending magnet source of Indus-2 synchrotron (2.5 GeV, 300 mA) has been commissioned, for the study of single and polycrystalline samples. The beamline optics is based on vertically focusing Pt-coated pre and post mirrors and sagittal focusing Si (311) based double crystal monochromator. Experimental station consists of a six circle diffractometer equipped with scintillation detector and an image plate area detector for powder diffraction. XRD experiments have been performed to study single crystal and polycrystalline samples.

43 PARTICLE ACCELERATORS↗

Present and Future X-ray Tomographic Microscopy at TOMCAT

During its first four years of life, the TOMCAT beamline at the Swiss Light Source has established itself as a state-of-the art hard x-ray tomographic microscopy endstation for experiments on a large variety of samples, ranging from the fields of biology to materials science. It routinely performs absorption as well as phase-contrast imaging with an isotropic voxel size ranging from 0.360 up to 14.8 microns. Phase contrast is obtained either with simple edge-enhancement, a modified transport of intensity approach or grating interferometry. Typical acquisition times are on the order of a few minutes, depending on energy and resolution. A recently implemented automatic sample exchanger is now available for high-throughput studies. In addition to further developments in phase-contrast imaging, current scientific activities at the beamline focus on pushing spatial and temporal resolution by a few orders of magnitude, aiming at nano- and 'real-time' tomography.

43 PARTICLE ACCELERATORS↗

A new experimental setup designed for the investigation of irradiation of nanosystems in the gas phase: A high intensity mass-and-energy selected cluster beam

DIAM (Dispositif d'Irradiation d'Agregats Moleculaires) is a new experimental setup devoted to investigate processes induced by irradiation at the nanoscale. The DIAM apparatus is based on a combination of techniques including a particle beam from high-energy physics, a cluster source from molecular and cluster physics, and mass spectrometry form analytical sciences. In this paper, we will describe the first part of the DIAM apparatus that consists of an ExB double spectrometer connected to a cluster ion source based on a continuous supersonic expansion in the presence of ionizing electrons. This setup produces high intensities of energy-and-mass selected molecular cluster ion beams (1000 s of counts s{sup -1}). The performance of the instrument will be shown through measurements of 6-8 keV beams of protonated water clusters, (H{sub 2}O){sub n}H{sup +} (n = 0-21) and mixed protonated (or deprotonated) water-pyridine cluster ions: PyrH{sup +}(H{sub 2}O){sub n} (n = 0-15), Pyr{sub 2}H{sup +} (H{sub 2}O){sub n} (n = 0-9), and (Pyr-H){sup +} (H{sub 2}O).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mirror with a variable amplitude - phase reflectance. 2. Modelling of a laser resonator with an active output mirror

We present the operator model of the laser resonator with an active output mirror based on the Fabry - Perot interferometer with nonflat (spherical and aspherical) mirrors and an adjustable gap. The results of numerical simulation of a microchip laser with a thermal lens and an active output interferometer-based mirror are given. It is shown that the use of an active interferometer as the output cavity mirror allows one to control the number of transverse modes of laser radiation and its power; in this case, the beam divergence can be reduced by a factor of 1.5 - 2.5. (laser resonators)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE INITIAL MASS FUNCTION AND DISK FREQUENCY OF THE {rho} OPHIUCHI CLOUD: AN EXTINCTION-LIMITED SAMPLE

We have completed an optical spectroscopic survey of an unbiased, extinction-limited sample of candidate young stars covering 1.3 deg{sup 2} of the {rho} Ophiuchi star-forming region. While infrared, X-ray, and optical surveys of the cloud have identified many young stellar objects (YSOs), these surveys are biased toward particular stages of stellar evolution and are not optimal for studies of the disk frequency and initial mass function. We have obtained over 300 optical spectra to help identify 135 association members based on the presence of H{alpha} in emission, lithium absorption, X-ray emission, a mid-infrared excess, a common proper motion, reflection nebulosity, and/or extinction considerations. Spectral types along with R- and I-band photometry were used to derive effective temperatures and bolometric luminosities for association members to compare with theoretical tracks and isochrones for pre-main-sequence stars. An average age of 3.1 Myr is derived for this population which is intermediate between that of objects embedded in the cloud core of {rho} Ophiuchi and low-mass stars in the Upper Scorpius subgroup. Consistent with this age we find a circumstellar disk frequency of 27% {+-} 5%. We also constructed an initial mass function for an extinction-limited sample of 123 YSOs (A{sub v} {<=} 8 mag), which is consistent with the field star initial mass function for YSOs with masses >0.2 M{sub sun}. There may be a deficit of brown dwarfs but this result relies on completeness corrections and requires confirmation.

79 ASTRONOMY AND ASTROPHYSICS↗

MEASURING THE SPIN OF GRS 1915+105 WITH RELATIVISTIC DISK REFLECTION

GRS 1915+105 harbors one of the most massive known stellar black holes in the Galaxy. In 2007 May, we observed GRS 1915+105 for approx117 ks in the low/hard state using Suzaku. We collected and analyzed the data with the Hard X-ray Detector/Positive Intrinsic Negative and X-ray Spectrometer cameras spanning the energy range from 2.3 to 55 keV. Fits to the spectra with simple models reveal strong disk reflection through an Fe K emission line and a Compton backscattering hump. We report constraints on the spin parameter of the black hole in GRS 1915 + 105 using relativistic disk reflection models. The model for the soft X-ray spectrum (i.e., < 10 keV) suggests a-hat=0.56{sup +0.02}{sub -0.02} and excludes zero spin at the 4sigma level of confidence. The model for the full broadband spectrum suggests that the spin may be higher, a-hat=0.98{sup +0.01}{sub =0.01} (1sigma confidence), and again excludes zero spin at the 2sigma level of confidence. We discuss these results in the context of other spin constraints and inner disk studies in GRS 1915 + 105.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-RESOLUTION X-RAY IMAGING OF SUPERNOVA REMNANT 1987A

We report observations of the remnant of supernova 1987A with the High Resolution Camera (HRC) on board the Chandra X-ray Observatory. A direct image from the HRC resolves the annular structure of the X-ray remnant, confirming the morphology previously inferred by deconvolution of lower resolution data from the Advanced CCD Imaging Spectrometer. Detailed spatial modeling shows that a thin ring plus a thin shell gives statistically the best description of the overall remnant structure, and suggests an outer radius of 0.''96 +- 0.''05 +- 0.''03 for the X-ray-emitting region, with the two uncertainties corresponding to the statistical and systematic errors, respectively. This is very similar to the radius determined by a similar modeling technique for the radio shell at a comparable epoch, in contrast to previous claims that the remnant is 10%-15% smaller at X-rays than in the radio band. The HRC observations put a flux limit of 0.010 counts s{sup -1} (99% confidence level, 0.08-10 keV range) on any compact source at the remnant center. Assuming the same foreground neutral hydrogen column density as toward the remnant, this allows us to rule out an unobscured neutron star with surface temperature T {sup i}nfinity > 2.5 MK observed at infinity, a bright pulsar wind nebula or a magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

CMEs FROM AR 10365: MORPHOLOGY AND PHYSICAL PARAMETERS OF THE EJECTIONS AND OF THE ASSOCIATED CURRENT SHEET

We study the evolution and physical parameters of three consecutive coronal mass ejections (CMEs) that occurred at the west limb of the Sun on 2003 June 2 at 00:30, 08:54, 16:08 UT, respectively. The Large Angle and Spectrometric Coronagraph Experiment (LASCO) CME catalog shows that the CMEs entered the C2 field of view with position angles within a 5 deg. interval. This suggests a common origin for the ejections, to be identified with the magnetic system associated with the active region that lies below the CMEs. The close proximity in time and source location of the events prompted us to analyze LASCO white light data and Ultraviolet Coronagraph Spectrometer (UVCS) spectra with the aim of identifying similarities and differences among the three CMEs. It turns out that two of them display the typical three-part structure, while no conclusion can be drawn about the morphology of the third ejection. The CMEs plasma is 'cool', i.e., electron temperatures in the CMEs front are of the order of 2 x 10{sup 5} K, with no significant variation between different events. However, ejection speeds vary by a factor of approx1.5 between consecutive events and electron densities (more precisely emission measures) by a factor of approx6 between the first CME and the second and third CMEs. In the aftermath of all events, we found evidence of current sheets (CSs) both in LASCO and UVCS. We give here the CS physical parameters (electron temperature, density, and kinetic temperature) and follow, in one of the events, their temporal evolution over a 6 hr time interval. A discussion of our results, in the framework of previous findings, concludes the paper.

79 ASTRONOMY AND ASTROPHYSICS↗

THE RELATIVE INTENSITY CALIBRATION OF HINODE/EIS AND SOHO/SUMER

In this work, we have used simultaneous observations of the quiet Sun above the solar west limb obtained with the Hinode/Extreme ultraviolet Imaging Spectrograph and SOHO/SUMER instruments to determine their relative intensity calibration. We used two different methods: intensity ratios of lines emitted by the same upper level and observed in the spectral ranges of the two spectrometers, and the determination of the differential emission measure and total emission measure of the plasma. We review the uncertainties in our analysis and conclude that the relative calibration of the two instruments, as it can be determined from the standard data reduction software of each of them, is correct within uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EXTREME ULTRAVIOLET EXPLORER OBSERVATIONS OF HERCULES X-1 OVER A 35 DAY CYCLE

Observations of Hercules X-1 by the Extreme Ultraviolet Explorer covering most of the 35 day cycle are reported here. This is the only long extreme ultraviolet (EUV) observation of Her X-1. Simultaneous X-ray observations with the Rossi X-ray Timing Explorer All-Sky Monitor (RXTE/ASM) X-ray show that Her X-1 is in an X-ray anomalous low state. The first 4 days are also observed with the RXTE proportional counter array (PCA), which shows that the X-ray properties are nearly the same as for normal low states in Her X-1 with flux reduced by a factor of 2. In contrast, the EUV emission from Her X-1 is reduced by a factor of {approx}4 compared to normal low states. The twisted-tilted accretion disk responsible for the normal 35 day X-ray cycle can be modified to explain this behavior. An increased disk twist reduces the X-ray illumination of HZ Her by a factor of {approx}2 and of the disk surface by a somewhat larger factor, leading to a larger reduction in EUV flux compared to X-ray flux.

79 ASTRONOMY AND ASTROPHYSICS↗

CORONAL FUZZINESS MODELED WITH PULSE-HEATED MULTI-STRANDED LOOP SYSTEMS

Coronal active regions are observed to get increasingly fuzzy (i.e., increasingly confused and uniform) in increasingly hard energy bands or lines. We explain this as evidence of fine multi-temperature structure of coronal loops. To this end, we model bundles of loops made of thin strands, each heated by short and intense heat pulses. For simplicity, we assume that the heat pulses are all equal and triggered only once in each strand at a random time. The pulse intensity and cadence are selected so as to have steady active region loops ({approx}3 MK) on average. We compute the evolution of the confined heated plasma with a hydrodynamic loop model. We then compute the emission along each strand in several spectral lines, from cool ({<=}1 MK), to warm (2-3 MK) lines, detectable with Hinode/Extreme-ultraviolet Imaging Spectrometer, to hot X-ray lines. The strands are then put side by side to construct an active region loop bundle. We find that in the warm lines (2-3 MK) the loop emission fills all the available image surface. Therefore, the emission appears quite uniform and it is difficult to resolve the single loops, while in the cool lines the loops are considerably more contrasted and the region is less fuzzy. The main reasons for this effect are that, during their evolution, i.e., pulse heating and slow cooling, each strand spends a relatively long time at temperatures around 2-3 MK and it has a high emission measure during that phase, so the whole region appears more uniform or smudged. We predict that fuzziness should be reduced in the hot UV and X-ray lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the magnetic field vector using multiple electromagnetically induced transparency resonances in Rb vapor

We study the dependence of electromagnetically induced transparency (EIT) resonance amplitudes on the external magnetic field direction in a linearly polarized bichromatic light (lin||lin) configuration in {sup 87}Rb vapor. We demonstrate that all seven resolvable EIT resonances exhibit maxima or minima at certain orientations of the laser polarization relative to the wave vector and magnetic field. This effect can be used for the development of a high-precision EIT vector magnetometer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗