Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRIC NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Matt Rogers on AES Energy Storage

The Department of Energy and AES Energy Storage recently agreed to a $17.1M conditional loan guarantee commitment. This project will develop the first battery-based energy storage system to provide a more stable and efficient electrical grid for New York State's high-voltage transmission network. Matt Rogers is the Senior Advisor to the Secretary for Recovery Act Implementation.

25 ENERGY STORAGE↗

Energy Systems Integration: Demonstrating the Grid Benefits of Connected Devices

Overview fact sheet about the Electric Power Research Institute (EPRI) and the University of Delaware Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network design for quantifying urban CO<sub>2</sub> emissions: assessing trade-offs between precision and network density

The majority of anthropogenic CO 2 emissions are attributable to urban areas. While the emissions from urban electricity generation often occur in locations remote from consumption, many of the other emissions occur within the city limits. Evaluating the effectiveness of strategies for controlling these emissions depends on our ability to observe urban CO 2 emissions and attribute them to specific activities. Cost-effective strategies for doing so have yet to be described. Here we characterize the ability of a prototype measurement network, modeled after the Berkeley Atmospheric CO 2 Observation Network (BEACO 2 N) in California's Bay Area, in combination with an inverse model based on the coupled Weather Research and Forecasting/Stochastic Time-Inverted Lagrangian Transport (WRF-STILT) to improve our understanding of urban emissions. The pseudo-measurement network includes 34 sites at roughly 2 km spacing covering an area of roughly 400 km 2 . The model uses an hourly 1 × 1 km 2 emission inventory and 1 × 1 km 2 meteorological calculations. We perform an ensemble of Bayesian atmospheric inversions to sample the combined effects of uncertainties of the pseudo-measurements and the model. We vary the estimates of the combined uncertainty of the pseudo-observations and model over a range of 20 to 0.005 ppm and vary the number of sites from 1 to 34. We use these inversions to develop statistical models that estimate the efficacy of the combined model–observing system in reducing uncertainty in CO 2 emissions. We examine uncertainty in estimated CO 2 fluxes on the urban scale, as well as for sources embedded within the city such as a line source (e.g., a highway) or a point source (e.g., emissions from the stacks of small industrial facilities). Using our inversion framework, we find that a dense network with moderate precision is the preferred setup for estimating area, line, and point sources from a combined uncertainty and cost perspective. The dense network considered here (modeled after the BEACO 2 N network with an assumed mismatch error of 1 ppm at an hourly temporal resolution) could estimate weekly CO 2 emissions from an urban region with less than 5 % error, given our characterization of the combined observation and model uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Natural gas maximal load delivery for multi-contingency analysis

An increasing dependence on natural gas has amplified existing vulnerabilities to the power grid, including disruptions to gas transmission networks from natural and man-made disasters. To address the operational challenges arising from these disruptions, we, in this study, consider the problem of estimating the steady-state operating capacity of a damaged gas pipeline network while ensuring the maximal delivery of load. Specifically, we formulate the mixed-integer nonconvex maximal load delivery (MLD) problem, which proves difficult to solve on large-scale networks. To address this challenge, we present a relaxation of the MLD problem and use it to determine bounds on the transport capacity of a gas pipeline system. A rigorous computational evaluation over network models ranging in size from 11 to 4,197 junctions shows that the relaxation-based method is suitable for analyzing the impacts of multi-contingency network disruptions, often converging to the optimal solution of the relaxation in less than ten seconds.

03 NATURAL GAS↗

Model-Based Integrated High Penetration Renewables Planning and Control Analysis

Increasing adoption of Solar Photovoltaic (PV) generation at the distribution level poses several changes for the reliable operation of electrical power distribution systems. The addition of a significant amount of PV to a distribution network can introduce a variety of operational problems, including steady-state overvoltages, reverse flows, voltage flicker and excessive controller movement among others. These adverse impacts can be mitigated through a variety of equipment upgrades which represent a cost to either the electric utility or the owner of the PV site. The study performed here aims to quantify the levels of PV generation which present operational problems on a distribution circuit and how those problems might be alleviated. The study performed here included 20 distribution feeders selected from Pepco Holdings, Inc. (PHI) service territory. These feeders are located in the states of Delaware, Maryland and New Jersey. A hosting capacity study was performed on each feeder to determine how much additional PV it could support in its current configuration. Several improvements were then performed on these circuits including phase balancing, capacitor redesign, reducing the voltage regulator set points, fixed power factor operation on the PV inverters and the installation of battery storage. After each of these improvements the hosting capacity of the circuit was reevaluated in order to determine how that particular improvement impacted the amount of PV that could be hosted by the circuit. Each of these improvements represents a real cost in terms of labor and equipment in order to be implemented. They are expected to provide a benefit in terms of the amount of additional PV generation which can be safely interconnected to the distribution feeder. A cost benefit analysis was performed in order to evaluate the expected costs of each feeder improvement and how each one was able to increase the PV hosting capacity of each feeder. It is hoped that these results can be utilized by other distribution utilities in order to understand how they can improve the hosting capacity of their feeders and facilitate the deployment of more PV generation at the distribution level. Admittedly other utility companies will most likely have different feeder architectures and differing labor and equipment costs so the realized cost benefit numbers may be significantly different.

14 SOLAR ENERGY↗

Transient photoresponse of nitrogen-doped ultrananocrystalline diamond electrodes in saline solution

Beyond conventional electrically-driven neuronal stimulation methods, there is a growing interest in optically-driven approaches. In recent years, nitrogen-doped ultrananocrystalline diamond (N-UNCD) has emerged as a strong material candidate for use in electrically-driven stimulation electrodes. This work investigates the electrochemical activity of N-UNCD in response to pulsed illumination, to assess its potential for use as an optically-driven stimulation electrode. Whilst N-UNCD in the as-grown state exhibits a weak photoresponse, the oxygen plasma treated film exhibits two orders of magnitude enhancement in its sub-bandgap open circuit photovoltage response. The enhancement is attributed to the formation of a dense network of oxygen-terminated diamond nanocrystals at the N-UNCD surface. Electrically connected to the N-UNCD bulk via sub-surface graphitic grain boundaries, these diamond nanocrystals introduce a semiconducting barrier between the sub-surface graphitic semimetal and the electrolyte solution, leading to a photovoltage under irradiation with wavelengths of λ = 450 nm and shorter. Within the safe optical exposure limit of 2 mW mm{sup −2}, charge injection capacity of 0.01 mC cm{sup −2} is achieved using a 15 × 15 μm electrode, meeting the requirements for extracellular and intercellular stimulation. The nanoscale nature of processes presented here along with the diamond's biocompatibility and biostability open an avenue for the use of oxygen treated N-UNCD as optically driven stimulating electrodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Utilities Power Change: Engaging Commercial Customers in Workplace Charging

As stewards of an electric grid that is available almost anywhere people park, utilities that support workplace charging are uniquely positioned to help their commercial customers be a part of the rapidly expanding network of charging infrastructure. Utilities understand the distinctive challenges of their customers, have access to technical information about electrical infrastructure, and have deep experience modeling and managing demand for electricity. This case study highlights the experiences of two utilities with workplace charging programs.

33 ADVANCED PROPULSION SYSTEMS↗

Relationship between microstructure evolution and properties enhancement of carbon nanotubes‐filled polybutylene terephthalate/polypropylene blends induced by thermal annealing

Abstract Thermal annealing induced microstructure evolution and properties enhancement of polybutylene terephthalate/polypropylene/carbon nanotubes (PBT/PP/CNTs) nanocomposites was methodically investigated. The electrical conductive PBT/PP/CNTs nanocomposites with a low percolation threshold were obtained by simple melt blending due to the selective location of the CNTs in PBT phase and the formation of the double percolation structure. Thermal annealing further remarkably decreased the volume resistivity of the nanocomposites, with the maximum reduction of seven orders of magnitude. Scanning electron microscope observation and rheology tests demonstrated that the relatively large CNTs agglomerates were redistributed to build more homogeneous CNTs networks after annealing. The phase coalescence during annealing promoted the formation of the more perfect co‐continuous structure. These phenomena helped to enhance the electrical conductivity of the nanocomposites. Flexural properties of the nanocomposites were also enhanced after annealing, which might be due to the more effective stress transfer between the polymer and CNTs induced by the reconstructed CNTs networks. The nanocomposites obtained in this study possess excellent electrical and mechanical properties, which can be applied to the fields of sensors, electromagnetic interference shielding, anti‐static materials, and so forth.

Shang, Mengyao↗

Power quality disturbances diagnosis: A 2D densely connected convolutional network framework

The fast and accurate diagnosis of power quality disturbances (PQD) aids in avoiding shutdowns and unnecessary procedures, concerning electric energy distribution systems. As such, a number of techniques have been tested and applied in order to reach this objective. Majority of the techniques applied are two-step based. On the first step, power quality disturbances features are extracted. Second step, considering features extracted, disturbance classification is implemented. Recently, relevant literature has presented data-driven signal processing-based approaches, as deep convolutional neural networks (DCNN), which can implement both processing steps while providing automated recognition of patterns and outliers in data. However, not considered by state-of-art, power quality disturbances are evolving in nature, while all possible regularities might not be represented in the dataset. In this work a 2 Dimension Densely Connected Convolutional Network (2D-DenseNet) framework is presented. Further, a case study with synthetic disturbance events are analyzed. Easy-to-implement formulation, built on the 2D-DenseNet, without hard-to-design parameters, highlight potential aspects for real-life implementation.

42 ENGINEERING↗

Combining Force Fields and Neural Networks for an Accurate Representation of Chemically Diverse Molecular Interactions

A key goal of molecular modeling is the accurate reproduction of the true quantum mechanical potential energy of arbitrary molecular ensembles with a tractable classical approximation. The challenges are that analytical expressions found in general purpose force fields struggle to faithfully represent the intermolecular quantum potential energy surface at close distances and in strong interaction regimes; that the more accurate neural network approximations do not capture crucial physics concepts, e.g., nonadditive inductive contributions and application of electric fields; and that the ultra-accurate narrowly targeted models have difficulty generalizing to the entire chemical space. We therefore designed a hybrid wide-coverage intermolecular interaction model consisting of an analytically polarizable force field combined with a short-range neural network correction for the total intermolecular interaction energy. Here, we describe the methodology and apply the model to accurately determine the properties of water, the free energy of solvation of neutral and charged molecules, and the binding free energy of ligands to proteins. The correction is subtyped for distinct chemical species to match the underlying force field, to segment and reduce the amount of quantum training data, and to increase accuracy and computational speed. For the systems considered, the hybrid ab initio parametrized Hamiltonian reproduces the two-body dimer quantum mechanics (QM) energies to within 0.03 kcal/mol and the nonadditive many-molecule contributions to within 2%. Simulations of molecular systems using this interaction model run at speeds of several nanoseconds per day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DC Fast Charging Infrastructure for Electrified Road Trips

To assess DC fast charging station network required for electrified road trips by 2030 in California, a new charging infrastructure simulation tool/model, EVI-Pro (Electric Vehicle Infrastructure Projection) RoadTrip, has been developed. In contrast to the existing EVI-Pro model that is primarily for short-distance travels, EVI-Pro RoadTrip is exclusively focused on road trips (long-distance travels, 100 or miles per day per vehicle). Also, the charging paradigm or strategy is different. EVI-Pro RoadTrip is built upon waypoint charging, in which vehicles are forced to stop to charge or replenish the on-board batteries, along the routes between origins and destinations. On the other hand, EVI-Pro is based on destination charging, in which charging is conducted when vehicles are parked in destinations (e.g., work, home). EVI-Pro RoadTrip takes coordinate-level origin and destination data for road trips (intra-state as well as domestic or international out-of-state) and estimates energy consumption and charging needs along the routes between origins and destinations on a minute-by-minute resolution. Based on charging demands for electrified road trips across the state, the optimal locations of charging stations are determined accounting for preferred land use types (e.g., commercial areas) and station service area (e.g., 5 or less miles). Based on station-by-station charging load profiles, the required number of plugs/connectors is estimated for each station and entire state. By comparing hosting capacity of the electric grid (circuit-level) and the charging load output from EVI-Pro RoadTrip, capacity deficit is also evaluated.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Enhanced thermoelectric performance of (Ba,In) double-filled skutterudites via randomly arranged micropores

Porous (Ba,In) double-filled skutterudite materials with pore diameter about 1–4 μm were prepared by the decomposition of metastable ZnSb inclusions induced by the Zn sublimation. Transport measurements revealed that the Seebeck coefficient was increased due to the electron filtering effect induced by nanostructures in the surfaces of pores, the electrical conductivity was almost unchanged because of the percolation effect of conducted network composed of filled skutterudites, and the lattice thermal conductivity was dramatically suppressed due to the enhanced pore-edge boundary scattering of long-wavelength phonons. As a result, a maximum ZT of 1.36 was obtained, increased by 22.5% as compared to that of the bulk material with same chemical composition. This work demonstrates that by introducing porous structures is thought to be an efficient approach to improve the thermoelectric performance of bulk materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Textured metastable VO{sub 2} (B) thin films on SrTiO{sub 3} substrates with significantly enhanced conductivity

Textured metastable VO{sub 2} (B) thin films with a layered structure were grown on SrTiO{sub 3} (001) by pulsed laser deposition. The X-ray diffraction and transmission electron microscopy results indicate that VO{sub 2} (B) films exhibit c-axis out-of-plane, while the films have 4 possible in-plane matching relations. In addition, a small amount of VO{sub 2} (M) phase can co-grow in the VO{sub 2} (B) phase when the film thickness exceeds a threshold. The thick VO{sub 2} films on STO exhibit a sharp metal-insulator transition with an increase of electrical conductivity in two orders of magnitude. This study may provide an alternative approach to enhance the performance of insulating VO{sub 2} (B) based batteries with increased electrical conductivity by incorporating VO{sub 2} (M) phase in the VO{sub 2} (B) phase layered network.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation: Preprint

This paper proposes a single-port equivalent and a two-port equivalent to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port remain unchanged over the reduction, including voltage magnitude and phase, active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Fault Detection Utilizing Convolution Neural Network on Timeseries Synchrophasor Data From Phasor Measurement Units

An end-to-end supervised learning method is proposed for fault detection in the electric grid using Big Data from multiple Phasor Measurement Units (PMUs). The approach consists of preprocessing steps aimed at reducing data noise and dimensionality, followed by utilization of six classification models considered for detecting faults. Three of the models were variants of Convolutional Neural Network (CNN) architectures that consider a single type of measurement (voltage, current or frequency) at all PMUs or all types together also at all PMUs. CNN based models were compared to traditional methods of Logistic Regression (LR), Multi-layer Perceptron (MLP) and Support Vector Machine (SVM). Evaluation was conducted on two-year data measured by PMUs at 37 locations in a large electric grid. Here, the response variable for classification were extracted from the grid-wide outage event log. Experiments show that CNN-based models outperformed traditional methods on one year out-of-sample outage detection over the entire grid.

42 ENGINEERING↗

Power System Network Reduction for Power Hardware-in-the-Loop Simulation

This paper proposes single-port equivalent and two-port equivalent network reduction methods to respectively reduce single-port and two-port areas in a large power network. Parameters of the reduced systems are rigorously derived, which guarantees that the electrical quantities at the port(s) remain unchanged over the reduction, including voltage magnitude and phase and active and reactive power injections into the area to be reduced. The proposed techniques are applied to reduce a practical Maui grid, where the total numbers of buses, lines and transformers are respectively reduced from 212, 106 and 108 to 45, 30 and 13. Dynamic behaviors between the full model and the reduced model are compared in detail to illustrate the efficacy and accuracy of the proposed network reduction.

model reduction↗