Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Evidence Report: Risk of Acute and Late Central Nervous System Effects from Radiation Exposure

Possible acute and late risks to the central nervous system (CNS) from galactic cosmic rays (GCR) and solar particle events (SPE) are concerns for human exploration of space. Acute CNS risks may include: altered cognitive function, reduced motor function, and behavioral changes, all of which may affect performance and human health. Late CNS risks may include neurological disorders such as Alzheimer's disease (AD), dementia and premature aging. Although detrimental CNS changes are observed in humans treated with high-dose radiation (e.g., gamma rays and 9 protons) for cancer and are supported by experimental evidence showing neurocognitive and behavioral effects in animal models, the significance of these results on the morbidity to astronauts has not been elucidated. There is a lack of human epidemiology data on which to base CNS risk estimates; therefore, risk projection based on scaling to human data, as done for cancer risk, is not possible for CNS risks. Research specific to the spaceflight environment using animal and cell models must be compiled to quantify the magnitude of CNS changes in order to estimate this risk and to establish validity of the current permissible exposure limits (PELs). In addition, the impact of radiation exposure in combination with individual sensitivity or other space flight factors, as well as assessment of the need for biological/pharmaceutical countermeasures, will be considered after further definition of CNS risk occurs.

Nelson, Gregory A.↗

A new dynamical atmospheric ionizing radiation (AIR) model for epidemiological studies

A new Atmospheric Ionizing Radiation (AIR) model is currently being developed for use in radiation dose evaluation in epidemiological studies targeted to atmospheric flight personnel such as civilian airlines crewmembers. The model will allow computing values for biologically relevant parameters, e.g. dose equivalent and effective dose, for individual flights from 1945. Each flight is described by its actual three dimensional flight profile, i.e. geographic coordinates and altitudes varying with time. Solar modulated primary particles are filtered with a new analytical fully angular dependent geomagnetic cut off rigidity model, as a function of latitude, longitude, arrival direction, altitude and time. The particle transport results have been obtained with a technique based on the three-dimensional Monte Carlo transport code FLUKA, with a special procedure to deal with HZE particles. Particle fluxes are transformed into dose-related quantities and then integrated all along the flight path to obtain the overall flight dose. Preliminary validations of the particle transport technique using data from the AIR Project ER-2 flight campaign of measurements are encouraging. Future efforts will deal with modeling of the effects of the aircraft structure as well as inclusion of solar particle events. Published by Elsevier Ltd on behalf of COSPAR.

Aviation↗

Mars Science Laboratory Radiation Assessment Detector (MSLRAD) Modeling Workshop Proceedings

The Radiation Assessment Detector (RAD) (Hassler et al., 2012) onboard the Mars Science Laboratory (MSL) Curiosity rover (Grotzinger et al., 2012) has been making detailed measurements of the radiation environment on the surface of Mars since landing on 6 August 2012 (Hassler et al., 2014; Zeitlin et al., 2016). These measurements are the first of their kind on the surface of another planet and are providing essential measurements of the radiation environment on Mars in preparation for a human mission in the coming decades. The objectives of RAD are; 1) to characterize the energetic particle spectrum on the surface of Mars as a function of time in the solar cycle, including direct (galactic cosmic rays and solar energetic particles) and indirect (neutrons, etc.) radiation created in the atmosphere and regolith, 2) to determine the dose and dose‐equivalent rates as a function of time in the solar cycle, and 3) to use these observations to test and validate space radiation transport models. Initial results of the charged particle spectra (Ehresmann et al., 2014) and neutral particle spectrum (Köhler et al., 2014), as well as dose and dose‐equivalent during cruise (Zeitlin et al., 2013) and on the surface (Hassler et al., 2014) have been reported, and with almost five years of continuous measurements, RAD continues to characterize the radiation environment as solar minimum is approached.

Donald M Hassler↗

Rear-Side Irradiance Simulation of Field PV Modules: Preprint

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand realworld outdoor degradation.

backsheet↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗

A perfused multi-well bioreactor platform to assess tumor organoid response to a chemotherapeutic gradient

There is an urgent need to develop new therapies for colorectal cancer that has metastasized to the liver and, more fundamentally, to develop improved preclinical platforms of colorectal cancer liver metastases (CRCLM) to screen therapies for efficacy. To this end, we developed a multi-well perfusable bioreactor capable of monitoring CRCLM patient-derived organoid response to a chemotherapeutic gradient. CRCLM patient-derived organoids were cultured in the multi-well bioreactor for 7 days and the subsequently established gradient in 5-fluorouracil (5-FU) concentration resulted in a lower IC 50 in the region near the perfusion channel versus the region far from the channel. We compared behaviour of organoids in this platform to two commonly used PDO culture models: organoids in media and organoids in a static (no perfusion) hydrogel. The bioreactor IC 50 values were significantly higher than IC 50 values for organoids cultured in media whereas only the IC 50 for organoids far from the channel were significantly different than organoids cultured in the static hydrogel condition. Using finite element simulations, we showed that the total dose delivered, calculated using area under the curve (AUC) was similar between platforms, however normalized viability was lower for the organoid in media condition than in the static gel and bioreactor. Our results highlight the utility of our multi-well bioreactor for studying organoid response to chemical gradients and demonstrate that comparing drug response across these different platforms is nontrivial.

59 BASIC BIOLOGICAL SCIENCES↗

Integrating Mercury Concentrations in American Alligators ( Alligator mississippiensis ) with Hunter Consumption Surveys to Estimate Exposure Risk

Mercury is a naturally occurring element but is also considered a widespread contaminant due to global anthropogenic activity. Even in moderate amounts, mercury (Hg) is an established neurotoxin and is associated with a range of adverse outcomes both in humans and wildlife. Humans in the United States are most commonly exposed to Hg through contaminated food or drinking water, and the consumption of game species, particularly those occupying higher trophic levels, has the potential to expose hunters to high concentrations of Hg. In the present study, we determined Hg concentrations in tail muscle and blood from American alligators (Alligator mississippiensis) inhabiting a region (Savannah River Site, SC, USA) with known Hg contamination. We then integrated these data with alligator harvest records and previously published surveys of alligator meat consumption patterns to estimate potential exposure risk. We found that the average Hg concentrations in tail muscle (1.34 mg/kg, wet wt) from sampled alligators exceeded the recommended threshold for Hg exposure based on the World Health Organization's guidelines (0.5mg/kg, wet wt). In addition, based on regional consumption patterns reported for both adults and children, we estimated Hg exposures (x¯ Adult = 0.419 μg/kg/day, x¯ Child = 2.24 μg/kg/day) occurring well above the US Environmental Protection Agency methylmercury reference dose of 0.1 μg/kg/day. Although the two reservoirs sampled in the present study are not currently open to alligator hunting, they are connected to waters that are publicly accessible, and the extent of alligator mobility across these sites is not known. Together, the findings reported in the present study further demonstrate the need for active monitoring of Hg concentrations in game species, which can convey substantial exposure risks to the public.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report on the Assessment of Ion Irradiations on High Entropy Alloys

Idaho National Laboratory (INL) initiated a joint international effort with the Czech Republic to explore the feasibility of manufacturing High Entropy Alloys for high-temperature nuclear applications using Additive Manufacturing. This effort was funded at INL by the United States Department of Energy’s Office of Nuclear Energy under the Advanced Reactor Technologies and Advanced Materials and Manufacturing Technologies (AMMT) Program. The High Entropy Alloys were specifically designed for the corrosive and irradiation environments as experienced in gas fast reactors, molten salt reactors, and fusion power. These alloys were manufactured by multiple processes to determine the impact of manufacturing processes on the performance of the alloys in corrosive and irradiation environments. Preliminary results show that MoNbTiV and MoNbTi alloys exhibit no degradation after multiple corrosion tests. These MoNbTiV and MoNbTi alloys were also evaluated after irradiation experiments were conducted at the Michigan Ion Beam Laboratory at the University of Michigan, which is the focus of this milestone report. For these irradiation experiments, the MoNbTiV and MoNbTi alloys manufactured by arc melting and Electric Field Assisted Sintering (EFAS) were tested at 500 C at a dose of 30 dpa to evaluate the microstructural stability and decomposition.

36 - MATERIALS SCIENCE↗

Analytical-HZETRN Model for Rapid Assessment of Active Magnetic Radiation Shielding

The use of active radiation shielding designs has the potential to reduce the radiation exposure received by astronauts on deep-space missions at a significantly lower mass penalty than designs utilizing only passive shielding. Unfortunately, the determination of the radiation exposure inside these shielded environments often involves lengthy and computationally intensive Monte Carlo analysis. In order to evaluate the large trade space of design parameters associated with a magnetic radiation shield design, an analytical model was developed for the determination of flux inside a solenoid magnetic field due to the Galactic Cosmic Radiation (GCR) radiation environment. This analytical model was then coupled with NASA's radiation transport code, HZETRN, to account for the effects of passive/structural shielding mass. The resulting model can rapidly obtain results for a given configuration and can therefore be used to analyze an entire trade space of potential variables in less time than is required for even a single Monte Carlo run. Analyzing this trade space for a solenoid magnetic shield design indicates that active shield bending powers greater than 15 Tm and passive/structural shielding thicknesses greater than 40 g/cm2 have a limited impact on reducing dose equivalent values. Also, it is shown that higher magnetic field strengths are more effective than thicker magnetic fields at reducing dose equivalent.

Washburn, S. A.↗

Deficits in Sustained Attention and Changes in Dopaminergic Protein Levels Following Exposure to Proton Radiation are Related to Basal Dopaminergic Function

The current report assessed the effects of low-level proton irradiation in inbred adult male Fischer 344 and Lewis rats performing an analog of the human Psychomotor Vigilance Test (PVT), commonly utilized as an object risk assessment tool to quantify fatigue and sustained attention in laboratory, clinical, and operational settings. These strains were used to determine if genetic differences in dopaminergic function would impact radiation-induced deficits in sustained attention. Exposure to head-only proton irradiation (25 or 100 cGy) disrupted rPVT performance in a strain-specific manner, with 25 cGy-exposed Fischer 344 rats displaying the most severe deficits in sustained attention (i.e., decreased accuracy and increased premature responding); Lewis rats did not display behavioral deficits following radiation. Fischer 344 rats displayed greater tyrosine hydroxylase and dopamine transporter levels in the frontal cortex compared to the Lewis rats, even though radiation exposure increased both of these proteins in the Lewis rats only. Tyrosine hydroxylase was decreased in the parietal cortex of both rat strains following radiation exposure, regardless of proton dose. Strain-specific cytokine changes were also found in the frontal cortex, with the Lewis rats displaying increased levels of putative neurotrophic cytokines (e.g., CNTF). These data support the hypothesis that basal dopaminergic function impacts the severity of radiation-induced deficits in sustained attention.

Catherine M Davis↗

Chemical composition of material extractives influences microbial growth and dynamics on wetted wood materials

The impact of material chemical composition on microbial growth on building materials remains relatively poorly understood. We investigate the influence of the chemical composition of material extractives on microbial growth and community dynamics on 30 different wood species that were naturally inoculated, wetted, and held at high humidity for several weeks. Microbial growth was assessed by visual assessment and molecular sequencing. Unwetted material powders and microbial swab samples were analyzed using reverse phase liquid chromatography with tandem mass spectrometry. Different wood species demonstrated varying susceptibility to microbial growth after 3 weeks and visible coverage and fungal qPCR concentrations were correlated (R 2 = 0.55). Aspergillaceae was most abundant across all samples; Meruliaceae was more prevalent on 8 materials with the highest visible microbial growth. A larger and more diverse set of compounds was detected from the wood shavings compared to the microbial swabs, indicating a complex and heterogeneous chemical composition within wood types. Several individual compounds putatively identified in wood samples showed statistically significant, near-monotonic associations with microbial growth, including C 11 H 16 O 4 , C 18 H 34 O 4 , and C 6 H 15 NO. A pilot experiment confirmed the inhibitory effects of dosing a sample of wood materials with varying concentrations of liquid C 6 H 15 NO (assuming it presented as Diethylethanolamine).

59 BASIC BIOLOGICAL SCIENCES↗

Novel dual-reflection design applied for ITER core x-ray spectrometer

Here. a novel dual-reflection configuration is introduced for the International Tokamak Experimental Reactor (ITER) core x-ray spectrometer to fit the allocated space where it will be placed accompanied by moving the detectors backward to reduce the incident radiation dose. The highly oriented pyrolytic graphite, which has a mosaic structure of microscopic crystallites, is chosen for the front reflector motivated by higher x-ray throughput and stronger misalignment tolerance compared to the perfect crystal reflector. In the ITER core x-ray spectrometer, a combination of several reflector-deflected Lines of Sight (LOSs) and a direct LOS is proposed for the first time named X-Ray Crystal Spectroscopy Core (XRCS-Core). The system is optimized to observe lines from externally seeded xenon and the intrinsic tungsten impurity, meeting both port integration needs and measurement requirements. Its spectral performance is simulated using an analytical-raytracing mixed code——XRSA, showing good imaging quality with a spectral resolution higher than 8000. The XRCS-Core system is thought to be applicable in various ITER scenarios through the assessment taking into account the spectrometers’ specifications and the chosen lines’ emissivity in different plasma parameters.

47 OTHER INSTRUMENTATION↗

Science Instrument Sensitivities to Radioisotope Power System Environment

Radioisotope Power Systems (RPS) have been and will be enabling or significantly enhancing for many missions, including several concepts identified in the 2011 Planetary Science Decadal Survey. Some mission planners and science investigators might have concerns about possible impacts from RPS-induced conditions upon the scientific capabilities of their mission concepts. To alleviate these concerns, this paper looks at existing and potential future RPS designs, and examines their potential radiation, thermal, vibration, electromagnetic interference (EMI), and magnetic fields impacts on representative science instruments and science measurements. Radiation impacts from RPS on science instruments are of potential concern for instruments with optical detectors and instruments with high-voltage electronics. The two main areas of concern are noise effects on the instrument measurements, and long-term effects of instrument damage. While RPS by their nature will contribute to total radiation dose, their addition for most missions should be relatively small. For example, the gamma dose rate from one Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) would be an order of magnitude lower than the environmental dose rate at Mars, and would have a correspondingly lower contribution to instrument noise and to any permanent damage to payload sensors. Increasing the number of General Purpose Heat Source (GPHS) modules used in an RPS would be expected to increase the generated radiation proportionally; however, the effect of more GPHS modules is mitigated from a strictly linear relationship by self-shielding effects. The radiation field of an RPS is anisotropic due to the deviation of the modules from a point-source-geometry. For particularly sensitive instruments the total radiation dose could be mitigated with separation or application of spot shielding. Though a new, higher-power RPS could generate more heat per unit than current designs, thermal impact to the flight system could be mitigated with shading and pointing if required by the mission. Alternatively, excess heat could prove beneficial in providing needed heat to spacecraft components and instruments in some thermal environments. Vibration for a new higher-power Stirling Radioisotope Generator (SRG) would be expected to be similar to the recent Advanced Stirling Radioisotope Generator (ASRG) design. While vibration should be low, it must be considered and addressed during spacecraft and instrument design. EMI and magnetic fields for new RPS concepts are expected to be low as for the current RPS, but must be considered and addressed if the mission includes sensitive instruments such as magnetometers. The assessment conducted for this paper focused on orbiter instrument payloads for two representative mission concepts- a Titan Saturn System Mission (TSSM) and a Uranus Orbiter and Probe (UOP)-since both of these Decadal Survey concepts would include many diverse instruments on board. Quick-look design studies using notional new RPS concepts were carried out for these two mission concepts, and their specific instrument packages were analyzed for their interactions with new RPS designs. The original Decadal Survey TSSM and UOP concepts did not have complete instrument performance requirements so typical measurement requirements were used where needed. Then, the general RPS environments were evaluated for impacts to various types of instruments. This paper describes how the potential impacts of the RPS on science instruments and measurements were assessed, which impacts were addressed, proposed mitigation strategies against those impacts, and provides an overview of future work.

RPS↗

Natural gas odorants: A scoping review of health effects

Organosulfur compounds are intentionally added to natural gas as malodorants with the intent of short-term nasal inhalation to aid in leak detection. Regulatory exposure limits have not been established for all commonly used natural gas odorants, and recent community-level exposure events and growing evidence of indoor natural gas leakage have raised concerns associated with natural gas odorant exposures. We conducted a scoping review of peer-reviewed scientific publications on human exposures and animal toxicological studies of natural gas odorants to assess toxicological profiles, exposure potential, health effects and regulatory guidelines associated with commonly used natural gas odorants. We identified only 22 studies which met inclusion criteria for full review. Overall, there is limited evidence of both transient nonspecific health symptoms and clinically diagnosed causative neurotoxic effects associated with prolonged odorant exposures. Across seven community-level exposure events and two occupational case reports, consistent symptom patterns included: headache, ocular irritation, nose and throat irritation, respiratory complaints such as shortness of breath and asthma attacks, and skin irritation and rash. Of these, respiratory inflammation and asthma exacerbations are the most debilitating, whereas the high prevalence of ocular and dermatologic symptoms suggest a non-inhalation route of exposure. The limited evidence available raises the possibility that organosulfur odorants may pose health risks at exposures much lower than presently understood, though additional dose-response studies are needed to disentangle specific toxicologic effects from nonspecific responses to noxious organosulfur odors. Numerous recommendations are provided including more transparent and prescriptive natural gas odorant use practices.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Comparison of dermal and inhalation routes of entry for organic chemicals

The quantitative comparison of the chemical concentration inside the body as the result of a dermal exposure versus an inhalation exposure is useful for assessing human health risks and deciding on an appropriate protective posture. In order to describe the relationship between dermal and inhalation routes of exposure, a variety of organic chemicals were evaluated. The types of chemicals chosen for the study were halogenated hydrocarbons, aromatic compounds, non-polar hydrocarbons and inhalation anesthetics. Both dermal and inhalation exposures were conducted in rats and the chemicals were in the form of vapors. Prior to the dermal exposure, rat fur was closely clipped and during the exposure rats were provided fresh breathing air through latex masks. Blood samples were taken during 4-hour exposures and analyzed for the chemical of interest. A physiologically based pharmacokinetic model was used to predict permeability constants (cm/hr) consistent with the observed blood concentrations of the chemical. The ratio of dermal exposure to inhalation exposure required to achieve the same internal dose of chemical was calculated for each test chemical. The calculated ratio in humans ranged from 18 for styrene to 1180 for isoflurane. This methodology can be used to estimate the dermal exposure required to reach the internal dose achieved by a specific inhalation exposure. Such extrapolation is important since allowable exposure standards are often set for inhalation exposures, but occupational exposures may be dermal.

Jepson, Gary W.↗

3D Visualization of Monte-Carlo Simulation's of HZE Track Structure and Initial Chemical Species

Heavy ions biophysics is important for space radiation risk assessment [1] and hadron-therapy [2]. The characteristic of heavy ions tracks include a very high energy deposition region close to the track (<20 nm) denoted as the track core, and an outer penumbra region consisting of individual secondary electrons (6-rays). A still open question is the radiobiological effects of 6- rays relative to the track core. Of importance is the induction of double-strand breaks (DSB) [3] and oxidative damage to the biomolecules and the tissue matrix, considered the most important lesions for acute and long term effects of radiation. In this work, we have simulated a 56Fe26+ ion track of 1 GeV/amu with our Monte-Carlo code RITRACKS [4]. The simulation results have been used to calculate the energy depiction and initial chemical species in a "voxelized" space, which is then visualized in 3D. Several voxels with dose >1000 Gy are found in the penumbra, some located ~0.1 mm from the track core. In computational models, the DSB induction probability is calculated with radial dose [6], which may not take into account the higher RBE of electron track ends for DSB induction. Therefore, these simulations should help improve models of DSB induction and our understanding of heavy ions biophysics.

Plante, Ianik↗

Chromosome aberrations of clonal origin are present in astronauts' blood lymphocytes

Radiation-induced chromosome translocations remain in peripheral blood cells over many years, and can potentially be used to measure retrospective doses or prolonged low-dose rate exposures. However, several recent studies have indicated that some individuals possess clones of cells with balanced chromosome abnormalities, which can result in an overestimation of damage and, therefore, influence the accuracy of dose calculations. We carefully examined the patterns of chromosome damage found in the blood lymphocytes of twelve astronauts, and also applied statistical methods to screen for the presence of potential clones. Cells with clonal aberrations were identified in three of the twelve individuals. These clonal cells were present in samples collected both before and after space flight, and yields are higher than previously reported for healthy individuals in this age range (40-52 years of age). The frequency of clonal damage appears to be even greater in chromosomes prematurely condensed in interphase, when compared with equivalent analysis in metaphase cells. The individuals with clonal aberrations were followed-up over several months and the yields of all clones decreased during this period. Since clonal aberrations may be associated with increased risk of tumorigenesis, it is important to accurately identify cells containing clonal rearrangements for risk assessment as well as biodosimetry. Copyright 2003 S. Karger AG, Basel.

Chromosomes, Human/radiation effects/ultrastructur↗