Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Directors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Resource Prospector: An Update on the Lunar Volatiles Prospecting and ISRU Demonstration Mission

Over the last two decades a wealth of new observations of the moon have demonstrated a lunar water system dramatically more complex and rich than was deduced following the Apollo era. Lunar water, and other volatiles, have the potential to be a valuable or enabling resource for future exploration. The NASA Human Exploration and Operations Mission Directorate (HEOMD) have selected a lunar volatiles prospecting mission for a concept study and potential flight in CY2021. The mission includes a rover-borne payload that (1) can locate surface and near-subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials.

Human Exploration and Operations Mission Directora↗

Additional Mission Applications for NASA's 13.3-kW Ion Propulsion System

NASA's Space Technology Mission Directorate has been recently developing critical technologies for high-power solar electric propulsion (SEP), including large deployable solar array structures and high-power electric propulsion components. An ion propulsion system based on these developments has been considered for many SEP technology demonstration missions, including the Asteroid Redirect Robotic Mission (ARRM) concept. These studies and the highpower SEP technology developments have generated excitement within NASA about the use of the ARRM ion propulsion system design for other types of potential missions. One application of interest is for Mars missions, especially with the types of orbiters now under consideration for flights in the early 2020's to replace the aging Mars Reconnaissance Orbiter. High-power SEP can deliver large payloads to Mars with many additional capabilities, including large orbital plane changes and roundtrip missions, compared to chemically-propelled spacecraft. Another application for high-power SEP is for exo-planet observation missions, where a large starshade spacecraft would need to be repositioned with respect to its companion telescope relatively frequently and rapidly. SEP is an enabling technology for the ambitious science goals of these types of missions. This paper will discuss the benefits of high-power SEP for these concepts based on the STMD technologies now under development.

Space Technology Mission Directorate↗

Pathways Final Presentation

This Power Point Presentation is a mandatory requirement for Pathway's Interns to complete prior to both graduation and full-time conversion to work as a regular NASA employee. This presentation briefly outlines Mercedes Zuk's duties and experiences during her first semester as a Pathway's Intern during the Spring 2015 rotation. This presentation discusses projects and work accomplished by Mrs. Zuk while working at NASA. The presentation further discusses the NASA Engineering Directorate and alignment with NASA's Vision, Mission, and Strategic Plan.

Engineering Directorate↗

NASA KSC Internship Experience & Project Report

As part of the Spring 2021 Engineering Student Trainee rotation with the National Aeronautics and Space Administration (NASA) through the Pathways program at Kennedy Space Center (KSC). I served under KSC’s Engineering directorate as a Pneumatics Engineering Intern for the Environmental and Life support Systems branch (NE-XF). During my Internship, I primarily supported the Exploration Ground Systems (EGS) program under the direct supervision of NE-XF Pneumatics Senior Engineer, Ruben Jaca, and NE-XF matrix supervisor, Stephen M. Anthony. I worked on the completion of a Pressure Vessel and Pressurized System (PVS) certification for a Payload Accommodation Subsystem (PAS) prototype. As part of the Pathways program, I was additionally exposed to various career and skill enhancement activities.

Internship↗

Nematic Colloidal Micro‐Robots as Physically Intelligent Systems

Abstract Physically intelligent micro‐robotic systems exploit information embedded in micro‐robots, their colloidal cargo, and their milieu to interact, assemble, and form functional structures. Nonlinear anisotropic fluids such as nematic liquid crystals (NLCs) provide untapped opportunities to embed interactions via their topological defects, complex elastic responses, and ability to dramatically restructure in dynamic settings. Here a four‐armed ferromagnetic micro‐robot is designed and fabricated to embed and dynamically reconfigure information in the nematic director field, generating a suite of physical interactions for cargo manipulation. The micro‐robot shape and surface chemistry are designed to generate a nemato‐elastic energy landscape in the domain that defines multiple modes of emergent, bottom‐up interactions with passive colloids. Micro‐robot rotation expands the ability to sculpt interactions; the energy landscape around a rotating micro‐robot is dynamically reconfigured by complex far‐from‐equilibrium dynamics of the micro‐robot's companion topological defect. These defect dynamics allow transient information to be programmed into the domain and exploited. Robust micro‐robotic manipulation strategies are demonstrated that exploit these diverse modes of nemato‐elastic interaction to achieve cargo docking, transport, release, and assembly of complex reconfigurable structures at multi‐stable sites. Such structures are of great interest to future developments of LC‐based advanced optical device and micro‐manufacturing in anisotropic environments.

Yao, Tianyi↗

Fine golden rings: Tunable surface plasmon resonance from assembled nanorods in topological defects of liquid crystals

Unprecedented, reversible, and dynamic control over an assembly of gold nanorods dispersed in liquid crystals (LC) is demonstrated. The LC director field is dynamically tuned at the nanoscale using microscale ring confinement through the interplay of elastic energy at different temperatures, thus fine-tuning its core replacement energy to reversibly sequester nanoscale inclusions at the microscale. As a result, this leads to shifts of 100 nm or more in the surface plasmon resonance peak, an order of magnitude greater than any previous work with AuNR composites.

36 MATERIALS SCIENCE↗

Synthetic active liquid crystals powered by acoustic waves.

Active nematic materials combine orientational order with activity at the microscopic level. Current experimental realizations of active nematics include vibrating elongated particles, cell layers, suspensions of elongated bacteria, and a mixture of bio-filaments with molecular motors. The majority of active nematics are of biological origin. The realization of a fully synthetic active liquid crystal comprised of a lyotropic chromonic liquid crystal energized by ultrasonic waves, is reported. This synthetic active liquid crystal is free from biological degradation and variability, exhibits phenomenology associated with active nematics, and enables precise and rapid activity control over a significantly extended range. It is demonstrated that the energy of the acoustic field is converted into microscopic extensile stresses disrupting long-range nematic order and giving rise to an undulation instability and proliferation of topological defects. The emergence of unconventional free-standing persistent vortices in the nematic director field at high activity levels is revealed. The results provide a foundation for the design of externally energized active liquid crystals with stable material properties and tunable topological defect dynamics crucial for the realization of reconfigurable microfluidic systems.

active matter↗

Liquid Crystal‐Based Detection of Antigens with ELISA Sensitivity

Abstract A highly sensitive label‐free liquid crystal (LC)‐based technique is presented for detecting Immunoglobulin G (IgG) antigens used to uncover viral infections. The effectiveness, sensitivity, and selectivity of this detection method is demonstrated with goat IgG antigen at concentrations as low as 100 pg ml −1 , which is comparable to the sensitivity of the current enzyme‐linked immunosorbent assay (ELISA). The sensor is fabricated by decorating a transmission electron microscopy grid immobilized glass surfaces with antibodies; the target antigen is detected by a liquid crystal suspended onto the grid. This is different from previous methods where the antigen is detected either at the LC‐aqueous interface or in an LC sandwich cell with an antibody/antigen‐decorated substrate. This new approach has advantages such as easy sample preparation, higher sensitivity, and better storage capabilities. Binding the target antigen to the antibody results in a reorientation of the LC director that is detected optically. In addition to demonstrating the sensitivity, the physical principle of the detection is also discussed. This technique may apply to detect virtually any antigen of interest.

36 MATERIALS SCIENCE↗

Non‐invasive imaging of cellulose microfibril orientation within plant cell walls by polarized Raman microspectroscopy

ABSTRACT Cellulose microfibrils represent the major scaffold of plant cell walls. Different packing and orientation of the microfibrils at the microscopic scale determines the macroscopic properties of cell walls and thus affect their functions with a profound effect on plant survival. We developed a polarized Raman microspectroscopic method to determine cellulose microfibril orientation within rice plant cell walls. Employing an array of point measurements as well as area imaging and subsequent Matlab‐assisted data processing, we were able to characterize the distribution of cellulose microfibril orientation in terms of director angle and anisotropy magnitude. Using this approach we detected differences between wild type rice plants and the rice brittle culm mutant, which shows a more disordered cellulose microfibril arrangement, and differences between different tissues of a wild type rice plant. This novel non‐invasive Raman imaging approach allows for quantitative assessment of cellulose fiber orientation in cell walls of herbaceous plants, an important advancement in cell wall characterization. Biotechnol. Bioeng. 2016;113: 82–90. © 2015 Wiley Periodicals, Inc.

Sun, Lan↗

Microscale modeling of effective mechanical and electrical properties of textiles

Here, a computational framework for assisting in the development of novel textiles is presented. Electronic textiles are key in the rapidly growing field of wearable electronics for both consumer and military uses. There are two main challenges to the modeling of electronic textiles: the discretization of the textile microstructure and the interaction between electromagnetic and mechanical fields. A director-based beam formulation with an assumed electrical current is used to discretize the fabric at the level of individual fibrils. The open-source package FEniCS was used to implement the finite element model. Contact integrals were added into the FEniCS framework so that multiphysics contact laws can be incorporated in the same framework, leveraging the code generation and automated differentiation capabilities of FEniCS to produce the tangents needed by the implicit solution method. The computational model is used to construct and determine the mechanical, thermal, and electrical properties of a representative volume elements of a plain woven textile. Dynamic relaxation to solve the mechanical fields and the electrical and thermal fields is solved statically for a given mechanical state. The simulated electrical responses are fit to a simplified Kirchhoff network model to determine effective resistances of the textile.

36 MATERIALS SCIENCE↗

Variation of methods in small-scale safety and thermal testing of improvised explosives

Here, one of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of homemade or improvised explosives (HMEs) to SSST testing, 16 HME materials were compared to 3 standard military explosives in a proficiency-type round robin study among five laboratories, two U.S. Department of Defense and three U.S. Department of Energy, sponsored by the Department of Homeland Security, Science & Technology Directorate, Explosives Division.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Abdominal Radiology fellowship website content and comprehensiveness

Purpose: Fellowship programs’ online content plays a key role in prospective Abdominal Radiology applicants’ evaluation of programs. The purpose of this study is to examine the online accessibility of Abdominal Radiology fellowships, the comprehensiveness of the program websites’ content, and evaluate whether specific program characteristics are associated with differentiated website comprehensiveness. Methods: A list of 67 Abdominal Radiology fellowship programs was obtained from the Society of Abdominal Radiology (SAR) website. Each of the 65 publicly-available fellowship websites was scored for the presence of 19 binary variables related to the program’s attributes and curriculum to assess informational comprehensiveness. Comprehensiveness scores were compared by program characteristics (accreditation status, region, and size) using Kruskal–Wallis and two-tailed t tests. Results: Mean comprehensiveness score of Abdominal Radiology fellowship websites as measured by online criteria met was 52.6% (10.0 ± 3.0/19). Application requirements and information, rotation scheduling, and program director contact were found on more than 87.5% of the 65 websites, whereas salary and benefits, social information, and alumni were listed on fewer than 33.8% (22/65) of websites. Program accreditation status, region, and size were not associated with difference in mean comprehensiveness scores. Conclusions: There is a discrepancy between information commonly sought by prospective Abdominal Radiology fellowship applicants and what is available on fellowship program websites. Programs and applicants alike may benefit from programs strengthening their online material.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Photo-Crosslinkable Benzaldehyde Polymers for Creating Liquid Crystal Lenses

We have studied new photo-crosslinkable benzaldehyde polymers with fragments including long hydrocarbon substituents in a side chain, as materials for creating a specified distribution of the pretilt angle of the director in a liquid crystal cell. We show that by changing the UV radiation exposure dose after rubbing the polymer layers, we can specify any pretilt angle in the range 0–90{sup o}. We have obtained the distribution of pretilt angles needed for creating liquid crystal lenses, where the maximum azimuthal anchoring energy of the liquid crystal with the alignment layer is increased to 2.5·10{sup –5} J/m{sup 2}, which allowed us to substantially reduce the number of defects and to improve the optical quality of the liquid crystal lens.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Angle-Resolved Transport Measurements Reveal Electronic Nematicity in Cuprate Superconductors

Observations of spontaneous breaking of the rotational symmetry in an electron fluid, the so-called “electronic nematicity,” have been reported in several quantum materials. We have developed several different methods, based on angle-resolved transport measurements, to determine the amplitude and the director of the nematic order. Here, we present methods that are applicable to thin films or single crystals, illustrate them with transport data obtained on copper oxide superconductors, and discuss their relative advantages and disadvantages.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strain and Electronic Nematicity in La 2- x Sr x CuO 4

Electronic nematicity has previously been observed in La 2- x Sr x CuO 4 thin films by the angle resolved transverse resistivity method with a director whose orientation is always pinned to the crystal axes when the film is grown on an orthorhombic substrate but not when the substrate is tetragonal. Furthermore we report on measurements of thin films grown on (tetragonal) LaSrAlO 4 and subsequently placed in an apparatus that allows the application of uniaxial compressive strain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Focus on Advancing High Performance Mass Spectrometry, Honoring Dr. Richard D. Smith, Recipient of the 2013 Award for a Distinguished Contribution in Mass Spectrometry

This special focus issue of the Journal of the American Society for Mass Spectrometry celebrates the accomplishments of Dr. Richard D. Smith, the recipient of the 2013ASMS Award for a Distinguished Contribution in Mass Spectrometry, and who serves as a Battelle Fellow, Chief Scientist in the Biological Sciences Division, and Director of Proteomics Research at Pacific Northwest National Laboratory (PNNL) in Richland, WA. The award is for his development of the electrodynamic ion funnel.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular simulations and NMR reveal how lipid fluctuations affect membrane mechanics

Lipid bilayers form the main matrix of functional cell membranes, and their dynamics underlie a host of physical and biological processes. Here we show that elastic membrane properties and collective molecular dynamics (MD) are related by the mean-square amplitudes (order parameters) and relaxation rates (correlation times) of lipid acyl chain motions. We performed all-atom MD simulations of liquid-crystalline bilayers that allow direct comparison with carbon-hydrogen (CH) bond relaxations measured with NMR spectroscopy. Previous computational and theoretical approaches have assumed isotropic relaxation, which yields inaccurate description of lipid chain dynamics and incorrect data interpretation. Instead, the new framework includes a fixed bilayer normal (director axis) and restricted anisotropic motion of the CH bonds in accord with their segmental order parameters, enabling robust validation of lipid force fields. Simulated spectral densities of thermally excited CH bond fluctuations exhibited well-defined spin-lattice (Zeeman) relaxations analogous to those in NMR measurements. Their frequency signature could be fit to a simple power-law function, indicative of nematic-like collective dynamics. Moreover, calculated relaxation rates scaled as the squared order parameters yielding an apparent K C modulus for bilayer bending. Our results show a strong correlation with K C values obtained from solid-state NMR studies of bilayers without and with cholesterol as validated by neutron spin-echo measurements of membrane elasticity. The simulations uncover a critical role of interleaflet coupling in membrane mechanics and thus provide important insights into molecular sites of emerging elastic properties within lipid bilayers.

59 BASIC BIOLOGICAL SCIENCES↗

A study of examiner accuracy in cartridge case comparisons. Part 1: Examiner error rates

This report describes a study undertaken to estimate examiner (not laboratory) error rates for false Identifications and false Eliminations when comparing an unknown to a collection of three known cartridge cases. Volunteer active examiners with Association of Firearm and Toolmark Examiners (AFTE) membership or working in laboratories that participate in the Association of Crime Laboratory Directors (ASCLD) were provided with 15 sets of three known and one questioned cartridge cases fired from a collection of 25 new Ruger SR9 handguns. Remington 9-mm Luger (manufacturer designation L9MM3) ammunition was used and comparison sets were made up of cartridge cases fired within 100 cartridges of each other for each gun. Examiners were provided with a background survey, an answer sheet allowing for the AFTE Range of Conclusions, and return shipping materials. In addition to determining whether the known and questioned cartridge cases were fired with the same handgun, examiners were also asked to assess how many of the three knowns in each set were suitable for comparison, providing an estimated rate of how often each firearm used in the study produces useable, quality marks. The participating examiners were provided with both same-source and different-source comparison sets allowing the study to assess both error rates. Responses were received from 218 participating examiners. The overall rate of false Eliminations was estimated as 0.367% from comparisons known to be from the same firearm but reported as Eliminations. The overall rate of false Identifications was estimated as 1.01% from comparisons known to be from different firearms but reported as Identifications. The rates are not uniform across the sample population with a few examiners providing most of the false Identification responses. Rates of poor-quality mark production varied across the 25 sample handguns; those rates were 2.3% (±1.4%). Both false Elimination and false Identification rates are comparable to or lower than the rate of production of poor-quality marks by the firearms used in this study.

99 GENERAL AND MISCELLANEOUS↗