Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digitalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Safety Assurance Framework for Nuclear Digital Instrumentation and Control Software

Software in digital instrumentation and control (D&C) systems poses unique challenges for the safety assurance of nuclear power plants. Through a literature survey of 21 sources, we analyzed various claims, arguments, and evidence used in safety assurance cases across industries. These were organized into a Goal Structuring Notation (GSN) safety assurance case framework to organize and visualize the various arguments for DI&C safety. We developed a classification for the levels of the framework, which can be used in other safety assurance cases to improve clarity.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Digital Assurance Checklist for Homeowners and Installers

This document provides a comprehensive Digital Assurance Checklist for securing behind-the-meter energy assets, focusing on both installers and homeowners. As distributed energy resources (DERs) such as solar PV and battery storage become integral to residential energy systems, cybersecurity emerges as a critical component of reliability and safety. The guide outlines actionable steps for installers during pre-installation, commissioning, and post-installation phases, emphasizing practices like network segmentation, credential management, firmware validation, and homeowner education. For homeowners, the document introduces a tiered approach to cyber hygiene—from essential measures like strong Wi-Fi credentials and automatic updates to advanced strategies such as network segmentation, DNS filtering, and intrusion detection. By adopting these practices, stakeholders can mitigate cyber risks, safeguard energy infrastructure, and ensure resilient, secure operation of DER systems. Additional resources and references to industry standards are included to support implementation.

99 - GENERAL AND MISCELLANEOUS↗

Development of Digital Twin-Informed Predictive Maintenance for Critical Components in Advanced Reactors

Small modular reactors (SMRs) and microreactors, along with other advanced reactor (AR) technologies, are key to the future of nuclear energy. For these systems to achieve low operating costs, high reliability, and flexibility across applications, their operation and maintenance must be optimized. Digital twin (DT) technology is one of the technologies that enables real-time (or faster than real-time) monitoring and prognosis of critical components which are vital for operational efficiency, low costs, and enhanced safety of ARs, accelerating their deployment. DT technology provides dynamic virtual representation of physical assets by integrating real-time data, physics-based models, and advanced analytics, which is critical to optimizing the performance of the entire energy system throughout the life cycle. DTs empower engineers and operators to virtually explore different scenarios, configurations, and control strategies, allowing for the identification of optimal solutions that maximize reactor efficiency, safety, and economics.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital Light Process 3D Printing of Magnetically Aligned Liquid Crystalline Elastomer Free–forms

Liquid crystalline elastomers (LCEs) are anisotropic soft materials capable of large dimensional changes when subjected to a stimulus. The magnitude and directionality of the stimuli-induced thermomechanical response is associated with the alignment of the LCE. Recent reports detail the preparation of LCEs by additive manufacturing (AM) techniques, predominately using direct ink write printing. Another AM technique, digital light process (DLP) 3D printing, has generated significant interest as it affords LCE free-forms with high fidelity and resolution. However, one challenge of printing LCEs using vat polymerization methods such as DLP is enforcing alignment. Here, we document the preparation of aligned, main-chain LCEs via DLP 3D printing using a 100 mT magnetic field. Systematic examination isolates the contribution of magnetic field strength, alignment time, and build layer thickness on the degree of orientation in 3D printed LCEs. Informed by this fundamental understanding, DLP is used to print complex LCE free-forms with through-thickness variation in both spatial orientations. Further, the hierarchical variation in spatial orientation within LCE free-forms is used to produce objects that exhibit mechanical instabilities upon heating. DLP printing of aligned LCEs opens new opportunities to fabricate stimuli-responsive materials in form factors optimized for functional use in soft robotics and energy absorption.

36 MATERIALS SCIENCE↗

K‐band luminosity–environment relation in three different galaxy samples of the Sloan Digital Sky Survey III

The aim of this work is to examine the environmental dependence of K‐band luminosity in the Main, Low Redshift (LOWZ), and Constant Mass (CMASS) galaxy samples of the Sloan Digital Sky Survey Data Release 10 (SDSS DR10). Overall, the environmental dependence of K‐band luminosity is very mild. In two volume‐limited Main samples with the luminosity −20.5 ≤ M r ≤ −18.5 and −22.5 ≤ M r ≤ −20.5, respectively, we find that the environmental dependence of K‐band luminosity in the luminous volume‐limited Main galaxy sample still can be observed, but this dependence in the faint volume‐limited Main galaxy sample is very weak. Considering the disadvantages of the use of volume‐limited samples, we apply the apparent magnitude‐limited Main galaxy sample, divide the Main galaxy sample of the SDSS DR10 into subsamples with a redshift binning size of Δ z =0.01, and then analyze the environmental dependence of K‐band luminosity of subsamples in each redshift bin. Such a method also is used in the LOWZ and CMASS galaxy samples. K‐band luminosity of the Main galaxies shows substantial correlation with the local environment in many redshift bins. In the LOWZ galaxy sample, K‐band luminosity of galaxies shows substantial correlation with the local environment only in the redshift region 0.16 ≤ z ≤ 0.21, while K‐band luminosity of CMASS galaxy sample is only weakly correlated with the local environment. Statistical results also show that in the apparent magnitude‐limited main galaxy sample and the LOWZ galaxy sample, environmental dependence of K‐band luminosity becomes weak with increasing redshift.

Deng, X. ‐F.↗

Digital radiography exposure indices: A review

Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research.

60 APPLIED LIFE SCIENCES↗

Characterization of Particle Size Standard NIST 1019b with SynchrotronX-ray Microtomography and Digital Data Extraction

We show that synchrotron x-ray microtomography ({mu}CT) followed by digital data extraction can be used to examine the size distribution and particle morphologies of the polydisperse (750 to 2450 {micro}m diameter) particle size standard NIST 1019b. Our size distribution results are within errors of certified values with data collected at 19.5 {micro}m/voxel. One of the advantages of using {mu}CT to investigate the particles examined here is that the morphology of the glass beads can be directly examined. We use the shape metrics aspect ratio and sphericity to examine of individual standard beads morphologies as a function of spherical equivalent diameters. We find that the majority of standard beads possess near-spherical aspect ratios and sphericities, but deviations are present at the lower end of the size range. The majority (> 98%) of particles also possess an equant form when examined using a common measure of equidimensionality. Although the NIST 1019b standard consists of loose particles, we point out that an advantage of {mu}CT is that coherent materials comprised of particles can be examined without disaggregation.

36 MATERIALS SCIENCE↗

Core–Multishell-Structured Digital-Gradient Cathode Materials with Enhanced Mechanical and Electrochemical Durability

Ni-rich cathode materials provide high energy density, but their structural and surface instability limits their cyclability and thermal stability. As one of the approaches to mitigate this problem, cathode materials comprising Ni-rich high-capacity core wrapped in Mn-rich multiple shells are produced successfully. In contrast to the conventional batch-type process for concentration-gradient materials, a digital-gradient cascade coprecipitation process described here achieves the improvements in productivity and quality consistency needed to move toward large-scale manufacturing. The core-multishell cathode materials produced in this manner not only have longer cycle life and improved rate performance compared to homogeneous Ni-rich cathode materials having the same overall composition, but also show remarkably enhanced thermal stability and low impedance growth characteristics. In a novel attempt to determine the correlation between the mechanical properties of the core-multishell cathode particles and their electrochemical cyclabilities, their breaking force and elasticity were successfully measured using a statistical approach, which indicates that a cathode particle with stable surface composition as well as high breaking force has improved capacity retention and durability. These results guide the realization of long life and high thermal stability in Ni-rich cathode materials through heterogeneous particle engineering.

25 ENERGY STORAGE↗

Digital Twins for Nuclear Power Plants and Facilities

The nuclear digital twin (DT) is the virtual representation of a nuclear energy system across its lifecycle. The nuclear DT uses real-time information and other data sources to improve the process of design, licensing, construction, security, O&M, decommissioning, and waste disposal. By leveraging the knowledge base and experience from the past 40 years of LWR operation, the nuclear DT is helping to accelerate the development and deployment of advanced nuclear technology in areas of passive safety, new fuel forms, instrumentation, and reactor control. For the currently operating nuclear fleet, DTs are reducing the operational risks, increasing plant availability, increasing energy capability, and reducing electricity production costs. For advanced fission and fusion reactors, DTs are being used to design for passive safety and built-in security-by-design. Rapidly deployable small modular reactor (SMR) and microreactor designs compatible with modular construction techniques and advanced manufacturing will be the new normal, reducing the need for large capital expenditures and compressing construction schedules. In addition, lower operational and maintenance costs will be realized by reducing the complexity of operations, staffing needs, and maintenance-related activities.

Kropaczek, Dave↗

Automatic Digitization and Orientation of Scanned Mesh Data for Floor Plan and 3D Model Generation

This paper describes a novel approach for generating accurate floor plans and 3D models of building interiors using scanned mesh data. Unlike previous methods, which begin with a high resolution point cloud from a laser range-finder, our approach begins with triangle mesh data, as from a Microsoft HoloLens. It generates two types of floor plans, a “pen-and-ink” style that preserves details and a drafting-style that reduces clutter. It processes the 3D model for use in applications by aligning it with coordinate axes, annotating important objects, dividing it into stories, and removing the ceiling. Its performance is evaluated on commercial and residential buildings, with experiments to assess quality and dimensional accuracy. Our approach demonstrates promising potential for automatic digitization and orientation of scanned mesh data, enabling floor plan and 3D model generation in various applications such as navigation, interior design, furniture placement, facilities management, building construction, and HVAC design.

Sharma, Ritesh↗

Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extrahepatic Arteries Originating from Hepatic Arteries: Analysis Using CT During Hepatic Arteriography and Visualization on Digital Subtraction Angiography

PurposeTo investigate the prevalence and site of origin of extrahepatic arteries originating from hepatic arteries on early phase CT during hepatic arteriography (CTHA) was accessed. Visualization of these elements on digital subtraction hepatic angiography (DSHA) was assessed using CTHA images as a gold standard.Materials and MethodsA total of 943 patients (mean age 66.9 ± 10.3 years; male/female, 619/324) underwent CTHA and DSHA. The prevalence and site of origin of extrahepatic arteries were accessed using CTHA and visualized using DSHA.ResultsIn 924 (98.0%) patients, a total of 1555 extrahepatic branches, representing eight types, were found to originate from hepatic arteries on CTHA. CTHA indicated the following extrahepatic branch prevalence rates: right gastric artery, 890 (94.4%); falciform artery, 386 (40.9%); accessory left gastric artery, 161 (17.1%); left inferior phrenic artery (IPA), 43 (4.6%); posterior superior pancreaticoduodenal artery, 33 (3.5%); dorsal pancreatic artery, 26 (2.8%); duodenal artery, 12 (1.3%); and right IPA, 4 (0.4%). In addition, 383 patients (40.6%) had at least one undetectable branch on DSHA. The sensitivity, specificity, and accuracy of visualization on DSHA were as follows: RGA, 80.0, 86.8, and 80.4%; falciform artery, 53.9, 97.7, and 80.0%; accessory LGA, 64.6, 98.6, and 92.3%; left IPA, 76.7, 99.8, and 98.7%; PSPDA, 100, 99.7, and 99.9%; dorsal pancreatic artery, 57.7, 100, and 98.8%; duodenal artery, 8.3, 99.9, and 98.7%; and right IPA, 0, 100, and 99.6%, respectively.ConclusionExtrahepatic arteries originating from hepatic arteries were frequently identified on CTHA images. These arteries were frequently overlooked on DSHA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transforming Dermatologic Imaging for the Digital Era: Metadata and Standards

Imaging is increasingly being used in dermatology for documentation, diagnosis, and management of cutaneous disease. The lack of standards for dermatologic imaging is an impediment to clinical uptake. Standardization can occur in image acquisition, terminology, interoperability, and metadata. This paper presents the International Skin Imaging Collaboration position on standardization of metadata for dermatologic imaging. Metadata is essential to ensure that dermatologic images are properly managed and interpreted. There are two standards-based approaches to recording and storing metadata in dermatologic imaging. The first uses standard consumer image file formats, and the second is the file format and metadata model developed for the Digital Imaging and Communication in Medicine (DICOM) standard. DICOM would appear to provide an advantage over using consumer image file formats for metadata as it includes all the patient, study, and technical metadata necessary to use images clinically. Whereas, consumer image file formats only include technical metadata and need to be used in conjunction with another actor—for example, an electronic medical record—to supply the patient and study metadata. The use of DICOM may have some ancillary benefits in dermatologic imaging including leveraging DICOM network and workflow services, interoperability of images and metadata, leveraging existing enterprise imaging infrastructure, greater patient safety, and better compliance to legislative requirements for image retention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of photonic micro-ring resonator based digital bit magnitude comparator

This paper details the novel design, simulation and analysis of the digital photonic single-bit magnitude comparator with the utilization of silicon micro-ring resonator as its core component. The micro-ring resonator uses electro-optic carrier injection modulation properties with its ring waveguide being structured in PIN diode. Five micro-ring resonators are used in the proposed design, with each corresponds to the specific logic mode operation. This work also presents the time varying simulation, where two predetermined 1-bit input stream is injected into the circuit at the data rate of 1 Gbps, where its output is observed via oscilloscope, where results are obtained at the sampling rate of 1.6 THz. The timing diagram for the entire simulation is also shown together with additional results obtained from the simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast all-optical digital comparator using quantum-dot semiconductor optical amplifiers

In this investigation, three types of 160 Gb/s all-optical digital comparators using quantum-dot semiconductor optical amplifiers (QD-SOAs) are constructed. These configurations have different combination patterns of logic gates and QD-SOAs. Based on numerical simulations, we investigate and evaluate the performance of the devices in terms of the number of logic gates and QD-SOAs, and the value of the extinction ratio (ER). In addition, we demonstrate the effect of amplified spontaneous emission (ASE) noise on the ER and Q-factor. The results show that two of the three configurations are superior to the other configuration in terms of circuit complexity, value of ER, and sensitivity to injection current. Moreover, these two configurations achieve ER values over 10 dB and Q-factor over 9, even when intense ASE noise is considered. The proposed configurations have several advantages such as high quality, easy configuration, insensitivity to injection current, and strong noise robustness, which are favorable for practical applications. This investigation also facilitates the specification of the pros and cons of each configuration, and the determination of the appropriate comparator according to the desired requirements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital signal processing in coupled photonic crystal waveguides and its application to an all-optical AND logic gate

The realization of all-optical AND logic gates for pulsed signal operation based on the photonic bandgap transmission phenomenon is proposed. We are using realistic planar air-hole type coupled photonic crystal waveguides (C-PCWs) with Kerr-type nonlinear background medium. The novelty of our analysis is that the proposed AND logic gate operates with the temporal solitons, which maintain a stable envelope propagating in the nonlinear C-PCWs, enabling true ultrafast full-optical digital signal processing in the time-domain. The bandgap transmission takes place when the operating frequency is chosen at the very edge of the dispersion curve of one of the supermodes in the C-PCWs. In this regard, our original fast and accurate method is used to efficiently calculate the supermodes of the C-PCW system. The underlying semi-analytical full-wave modal analysis is based on the evaluation of the lattice sums for complex wavenumbers using the transition-matrix method in combination with the generalized reflection-matrix approach. As a proof of concept successful pulse operation of the all-optical AND logic gate is demonstrated in the framework of extensive full-wave finite-difference time-domain electromagnetics analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗