Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Digital image correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Deep learning for Alzheimer's disease: Mapping large-scale histological tau protein for neuroimaging biomarker validation

Abnormal tau inclusions are hallmarks of Alzheimer's disease and predictors of clinical decline. Several tau PET tracers are available for neurodegenerative disease research, opening avenues for molecular diagnosis in vivo. However, few have been approved for clinical use. Understanding the neurobiological basis of PET signal validation remains problematic because it requires a large-scale, voxel-to-voxel correlation between PET and (immuno) histological signals. Large dimensionality of whole human brains, tissue deformation impacting co-registration, and computing requirements to process terabytes of information preclude proper validation. We developed a computational pipeline to identify and segment particles of interest in billion-pixel digital pathology images to generate quantitative, 3D density maps. The proposed convolutional neural network for immunohistochemistry samples, IHCNet, is at the pipeline's core. We have successfully processed and immunostained over 500 slides from two whole human brains with three phospho-tau antibodies (AT100, AT8, and MC1), spanning several terabytes of images. Our artificial neural network estimated tau inclusion from brain images, which performs with ROC AUC of 0.87, 0.85, and 0.91 for AT100, AT8, and MC1, respectively. Introspection studies further assessed the ability of our trained model to learn tau-related features. We present an end-to-end pipeline to create terabytes-large 3D tau inclusion density maps co-registered to MRI as a means to facilitate validation of PET tracers.

60 APPLIED LIFE SCIENCES↗

An array processing system for lunar geochemical and geophysical data

A computerized array processing system has been developed to reduce, analyze, display, and correlate a large number of orbital and earth-based geochemical, geophysical, and geological measurements of the moon on a global scale. The system supports the activities of a consortium of about 30 lunar scientists involved in data synthesis studies. The system was modeled after standard digital image-processing techniques but differs in that processing is performed with floating point precision rather than integer precision. Because of flexibility in floating-point image processing, a series of techniques that are impossible or cumbersome in conventional integer processing were developed to perform optimum interpolation and smoothing of data. Recently color maps of about 25 lunar geophysical and geochemical variables have been generated.

Eliason, E. M.↗

Digital imaging techniques in experimental stress analysis

Digital imaging techniques are utilized as a measure of surface displacement components in laser speckle metrology. An image scanner which is interfaced to a computer records and stores in memory the laser speckle patterns of an object in a reference and deformed configuration. Subsets of the deformed images are numerically correlated with the references as a measure of surface displacements. Discrete values are determined around a closed contour for plane problems which then become input into a boundary integral equation method in order to calculate surface traction in the contour. Stresses are then calculated within this boundary. The solution procedure is illustrated by a numerical example of a case of uniform tension.

Peters, W. H.↗

Antimisting fuel breakup and flammability

The breakup behavior and flammability of antimisting turbine fuels subjected to aerodynamic shear are investigated. Fuels tested were Jet A containing 0.3% FM-9 polymer at various levels of degradation ranging from virgin AMK to neat Jet A. The misting behavior of the fuels was quantified by droplet size distribution measurements. A technique based on high resolution laser photography and digital image processing of photographic records for rapid determination of droplet size distribution was developed. The flammability of flowing droplet-air mixtures was quantified by direct measurements of temperature rise in a flame established in the wake of a continuous ignition source. The temperature rise measurements were correlated with droplet size measurements. The flame anchoring phenomenon associated with the breakup of a liquid fuel in the wake of bluff body was shown to be important in the context of a survivable crash scenario. A pass/fail criterion for flammability testing of antimisting fuels, based on this flame-anchoring phenomenon, was proposed. The role of various ignition sources and their intensity in ignition and post-ignition behavior of antimisting fuels was also investigated.

Parikh, P.↗

Functional Flight Test Report for Positive Systems' ADAR System 5500 Sensor SN8 Linear

This report describes results of the functional flight test conducted with the Positive Systems' ADAR 5500 sensor system (serial number 8, linear configuration) near Winslow, Arizona on June 30 and July 1, 1999. The in-flight test is one component of the NASA Scientific Data Purchase (SDP) Validation and Verification (V&V) process. It allows to measure characteristics of the entire sensor system affected by both performance of the sensor during a flight and post-flight image processing. The following characteristics were analyzed: changes of dark digital numbers (DN's), radiometric linearity, signal-to-noise ratio (SNR), spatial resolution, and geolocation accuracy. The measured characteristics were compared with the image product specifications defined in the Positive Systems' SDP contract. Dependence of the dark DN's on several factors was analyzed, but no significant correlation was found. However, the observed changes in dark DN's were relatively small, which justifies usage of a constant value in the dark DN subtraction procedure during post-processing. Dependence of measured at-sensor, in-band radiance (in arbitrary units) on measured in-band ground reflectance is very well described by a linear function - The sensor fulfills the linearity requirement. Measured SNR values lower than the contract specifications, but accuracy of that test was possibly affected by non-uniformity of the employed gray-scale panels. The SNR values are generally sufficiently high for most applications. SNR can also be improved during standard flights by using longer exposure times. Full width at half maximum (FWHM) of an edge response derived line spread function was used as a measure of spatial resolution. FWHM was generally smaller than twice the ground sample distance (GSD), in agreement with the contract specifications. Accuracy of the geolocation information, which is provided for the particular images in a metadata file, was found to meet contract requirements as well.

Stanley, Tom↗

Concerning the feasibility of a real time SAR digital processor for VOIR low resolution imaging modes

The feasibility of real time digital processing of synthetic aperture radar data for Venus orbiting imaging radar low resolution modes was investigated. First, it is shown that range migration is not a problem for these modes. Then, under the assumption of no range migration, fast Fourier transform implementations for accomplishing both range and azimuth correlation in real time are shown to be feasible with current technology.

Truong, T. K.↗

JMISR INteractive eXplorer

MISR (Multi-angle Imaging SpectroRadiometer) INteractive eXplorer (MINX) is an interactive visualization program that allows a user to digitize smoke, dust, or volcanic plumes in MISR multiangle images, and automatically retrieve height and wind profiles associated with those plumes. This innovation can perform 9-camera animations of MISR level-1 radiance images to study the 3D relationships of clouds and plumes. MINX also enables archiving MISR aerosol properties and Moderate Resolution Imaging Spectroradiometer (MODIS) fire radiative power along with the heights and winds. It can correct geometric misregistration between cameras by correlating off-nadir camera scenes with corresponding nadir scenes and then warping the images to minimize the misregistration offsets. Plots of BRF (bidirectional reflectance factor) vs. camera angle for points clicked in an image can be displayed. Users get rapid access to map views of MISR path and orbit locations and overflight dates, and past or future orbits can be identified that pass over a specified location at a specified time. Single-camera, level-1 radiance data at 1,100- or 275- meter resolution can be quickly displayed in color using a browse option. This software determines the heights and motion vectors of features above the terrain with greater precision and coverage than previous methods, based on an algorithm that takes wind direction into consideration. Human interpreters can precisely identify plumes and their extent, and wind direction. Overposting of MODIS thermal anomaly data aids in the identification of smoke plumes. The software has been used to preserve graphical and textural versions of the digitized data in a Web-based database.

Nelson, David L.↗

Characterization of Solidification Microstructures in Vacuum Arc Remelted Nickel Alloy 718

Digital image analysis techniques were developed to autonomously characterize dendritic solidification features in microstructures of a nickel alloy 718 ingot produced by vacuum arc remelting (VAR). Automated macrophotography was implemented to image microstructures and produce large image montages of etched ingot cross sections. Two image analysis techniques, particle identification and two-point correlation, were applied to autonomously measure primary dendrite arm orientation and secondary dendrite arm spacing from the image montages. Particle identification measured individual dendritic features. The two-point correlation technique measured averaged feature values over defined image areas. These methods are described and compared. Melt pool profile and solidification time histories were reconstructed from primary dendrite arm orientation and secondary dendrite arm spacing measurements, respectively. These characterization techniques provide two new methods of reconstructing melt pool profiles and solidification times in cast ingots. The information produced is expected to be useful in the validation of computational models for solidification during VAR, similar remelting processes, and general casting processes that produce dendritic solidification features.

36 MATERIALS SCIENCE↗

Comparison of manually produced and automated cross country movement maps using digital image processing techniques

The Image-Based Information System (IBIS) was used to automate the cross country movement (CCM) mapping model developed by the Defense Mapping Agency (DMA). Existing terrain factor overlays and a CCM map, produced by DMA for the Fort Lewis, Washington area, were digitized and reformatted into geometrically registered images. Terrain factor data from Slope, Soils, and Vegetation overlays were entered into IBIS, and were then combined utilizing IBIS-programmed equations to implement the DMA CCM model. The resulting IBIS-generated CCM map was then compared with the digitized manually produced map to test similarity. The numbers of pixels comprising each CCM region were compared between the two map images, and percent agreement between each two regional counts was computed. The mean percent agreement equalled 86.21%, with an areally weighted standard deviation of 11.11%. Calculation of Pearson's correlation coefficient yielded +9.997. In some cases, the IBIS-calculated map code differed from the DMA codes: analysis revealed that IBIS had calculated the codes correctly. These highly positive results demonstrate the power and accuracy of IBIS in automating models which synthesize a variety of thematic geographic data.

Wynn, L. K.↗

Jupiter: New estimates of mean zonal flow at the cloud level

In order to reexamine the magnitude differences of the Jovian atmosphere's jets, as determined by Voyager 1 and 2 images, a novel approach is used to ascertain the zonal mean east-west component of motion. This technique is based on digital pattern matching, and is applied on pairs of mapped images to yield a profile of the mean zonal component that reproduces the exact locations of the easterly and westerly jets between + and 60 deg latitude. Results were obtained for all of the Voyager 1 and 2 cylindrical mosaics; the correlation coefficient between Voyagers 1 and 2 in mean zonal flow between + and - 60 deg latitude, determined from violet filter mosaics, is 0.998.

Limaye, Sanjay S.↗

Structure of the Saint Francois Mountains and surrounding lead belt, S.E. Missouri: Inference from thermal IR and other data sets

Progress in the preparation of manuscripts on the discovery of a Precambrian rift running NW-SE through Missouri as seen in free air and Bouguer gravity anomalies and in HCMM data, and on digital image processing of potential field and topographic data on the rift is reported. Copies of the papers are attached. Contrast-enhanced HCMM images that have been transformed to Mercator projections are presented. Shaded relief map overlays of thermal and apparent thermal inertia images used as part of a masers thesis examining correlations between HCMM data products, linears, and geologic units are presented. Progress in examination of the difference in information content of daytime infrared, night time infrared, albedo, and thermal inertia images and their application to he identification of linears not directly controlled by topography is reported. Thermal infrared and albedo data were coded as hue, saturation and brightness values to generate a color display, which is included.

Arvidson, R. E.↗

Jupiter - New estimates of the mean zonal flow at the cloud level

In order to reexamine the magnitude differences of the Jovian atmosphere's jets, as determined by Voyager 1 and 2 images, a novel approach is used to ascertain the zonal mean east-west component of motion. This technique is based on digital pattern matching, and is applied on pairs of mapped images to yield a profile of the mean zonal component that reproduces the exact locations of the easterly and westerly jets between + and - 60 deg latitude. Results have been obtained for all of the Voyager 1 and 2 cylindrical mosaics; the correlation coefficient between Voyagers 1 and 2 in mean zonal flow between + and - 60 deg latitude, determined from violet filter mosaics, is 0.998.

Limaye, S. S.↗

SU-D-18C-01: A Novel 4D-MRI Technology Based On K-Space Retrospective Sorting

Purpose: Current 4D-MRI techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of an entirely new framework of 4D-MRI based on k-space retrospective sorting. Methods: An important challenge of the proposed technique is to determine the number of repeated scans(NR) required to obtain sufficient k-space data for 4D-MRI. To do that, simulations using 29 cancer patients' respiratory profiles were performed to derive the relationship between data acquisition completeness(Cp) and NR, also relationship between NR(Cp=95%) and the following factors: total slice(NS), respiratory phase bin length(Lb), frame rate(fr), resolution(R) and image acquisition starting-phase(P0). To evaluate our technique, a computer simulation study on a 4D digital human phantom (XCAT) were conducted with regular breathing (fr=0.5Hz; R=256×256). A 2D echo planer imaging(EPI) MRI sequence were assumed to acquire raw k-space data, with respiratory signal and acquisition time for each k-space data line recorded simultaneously. K-space data was re-sorted based on respiratory phases. To evaluate 4D-MRI image quality, tumor trajectories were measured and compared with the input signal. Mean relative amplitude difference(D) and cross-correlation coefficient(CC) are calculated. Finally, phase-sharing sliding window technique was applied to investigate the feasibility of generating ultra-fast 4D-MRI. Result: Cp increased with NR(Cp=100*[1-exp(-0.19*NR)], when NS=30, Lb=100%/6). NR(Cp=95%) was inversely-proportional to Lb (r=0.97), but independent of other factors. 4D-MRI on XCAT demonstrated highly accurate motion information (D=0.67%, CC=0.996) with much less artifacts than those on image-based sorting 4D-MRI. Ultra-fast 4D-MRI with an apparent temporal resolution of 10 frames/second was reconstructed using the phase-sharing sliding window technique. Conclusions: A novel 4D-MRI technology based on k-space sorting has been successfully developed and evaluated on the digital phantom. Framework established can be applied to a variety of MR sequences, showing great promises to develop the optimal 4D-MRI technique for many radiation therapy applications. NIH (1R21CA165384-01A1)

60 APPLIED LIFE SCIENCES↗

Second generation digital techniques for processing LANDSAT MSS data

Results are reported for precision corrected LANDSAT MSS full scene registration of better than 0.5 picture element (rms), utilizing all digital methods. Examples of such registered full scene images are presented and evaluated by two methods: (1) change detection imagery which represents pixel by pixel the difference of corresponding pixel values in the registered data; and (2) direct measurement of registration errors throughout the imagery by means of a highly accurate cross correlation algorithm. Subscene image details illustrate the impact on registration accuracy of two interpolation algorithms.

Rifman, S. S.↗

Digital image processing of vascular angiograms

The paper discusses the estimation of the degree of atherosclerosis in the human femoral artery through the use of a digital image processing system for vascular angiograms. The film digitizer uses an electronic image dissector camera to scan the angiogram and convert the recorded optical density information into a numerical format. Another processing step involves locating the vessel edges from the digital image. The computer has been programmed to estimate vessel abnormality through a series of measurements, some derived primarily from the vessel edge information and others from optical density variations within the lumen shadow. These measurements are combined into an atherosclerosis index, which is found in a post-mortem study to correlate well with both visual and chemical estimates of atherosclerotic disease.

Selzer, R. H.↗

Stereocorrelation of Landsat TM images

A digital elevation model (DEM) developed from Landsat TM images of a rugged terrain area in north Georgia by automated stereocorrelation techniques yielded an rms error (z), RMSE(z), value of + or - 42 m. Based on the B/H ratio of 0.18 for the Landsat data, this Z-error corresponds to a planimetric correlation accuracy of about + or - 0.3 pixels, confirming that precise correlation can be achieved with operational satellite data. Contours at a 100-m interval interpolated from the DEM show a deviation of + or - 33 m from reference contours obtained from existing 1:24,000-scale maps. The 28.5-m pixel resolution and the weak B/H ratio impose limitations on the accuracy that can be achieved with Landsat TM data. However, it is anticipated that RMSE(z) values of + or - 10 m or less can be achieved with SPOT-1 panchromatic stereo images of 10-m resolution recorded at B/H ratios of 0.5 to 1.0. DEMs generated by stereocorrelation techniques can be used to create orthoimages, perspective views, and topographic map products.

Ehlers, Manfred↗

Terrain Relative Navigation in a Lunar Landing Scenario Using autoNGC

NASA Goddard Space Flight Center is developing Autonomous Navigation Guidance and Control (autoNGC) as a flight software system for future onboard use for missions in a variety of orbital regimes, including cislunar space and beyond. This paper describes processor-in-the-loop (PIL) testing using a lunar landing scenario with terrain relative navigation (TRN) and weak-signal GPS. We give an overview of the autoNGC project and describe preliminary navigation simulation results. We also describe the TRN PIL tests on a flight-like development board, using simulated images rendered from Lunar Reconnaissance Orbit high-resolution digital terrain models. The navigation simulations show that weak-signal GPS combined with TRN during a descent from a low lunar parking orbit results in sufficiently low navigation uncertainties to support such a mission profile independent of ground-based navigation. The PIL tests show that onboard image processing and landmark correlation is achievable at a sufficiently high measurement rate.

Michael A Shoemaker↗

Evaluation of Digital Image Recognition Methods for Mass Spectrometry Imaging Data Analysis

Analyzing mass spectrometry imaging data can be laborious and time consuming, and as the size and complexity of datasets grow, so does the need for robust automated processing methods. We here present a method for comprehensive, semi-targeted discovery of molecular distributions of interest from mass spectrometry imaging data, using widely available image similarity scoring algorithms to rank images by spatial correlation. A fast and powerful batch search method using a MATLAB implementation of structural similarity (SSIM) index scoring with a pre-selected reference distribution is demonstrated for two sample imaging datasets, a plant metabolite study using Artemisia annua leaf, and a drug distribution study using maraviroc-dosed macaque tissue. .

97 MATHEMATICS AND COMPUTING↗