Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 {+-} 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 {+-} 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 {+-} 4.7 months. Mean survival and freedom from any event was 66.7 {+-} 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P < 0.01). Patients in whom all aneurysm side branches were occluded prior to stent-grafting showed a significantly reduced incidence of large endoleaks. Endoleaks >10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks ({Delta} at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side branches reduced the incidence of large endoleaks. Large endoleaks significantly impaired aneurysm shrinkage, whereas small endoleaks did not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Unusual Complication Following Transarterial Chemoembolization: Acute Myocardial Infarction

Transarterial chemoembolization has been widely used to treat unresectable hepatocellular carcinoma. Various complications have been reported, but they have not included acute myocardial infarction. Acute myocardial infarction results mainly from coronary artery occlusion by plaques that are vulnerable to rupture or from coronary spasm, embolization, or dissection of the coronary artery. It is associated with significant morbidity and mortality. We present a case report that describes a patient with hepatocellular carcinoma who underwent transarterial chemoembolization and died subsequently of acute myocardial infarction. To our knowledge, there has been no previous report of this complication induced by transarterial chemoembolization for hepatocellular carcinoma. This case illustrates the need to be aware of acute myocardial infarction when transarterial chemoembolization is planned for the treatment of hepatocellular carcinoma, especially in patients with underlying coronary artery disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Always Contact a Vascular Interventional Specialist Before Amputating a Patient with Critical Limb Ischemia

Patients with severe critical limb ischemia (CLI) due to long tibial artery occlusions are often poor candidates for surgical revascularization and frequently end up with a lower limb amputation. Subintimal angioplasty (SA) offers a minimally invasive alternative for limb salvage in this severely compromised patient population. The objective of this study was to evaluate the results of SA in patients with CLI caused by long tibial occlusions who have no surgical options for revascularization and are facing amputation. We retrospectively reviewed all consecutive patients with CLI due to long tibial occlusions who were scheduled for amputation because they had no surgical options for revascularization and who were treated by SA. A total of 26 procedures in 25 patients (14 males; mean age, 70 {+-} 15 [SD] years) were evaluated. Technical success rate was 88% (23/26). There were four complications, which were treated conservatively. Finally, in 10 of 26 limbs, no amputation was needed. A major amputation was needed in 10 limbs (7 below-knee amputations and 3 above-knee amputations). Half of the major amputations took place within 3 months after the procedure. Cumulative freedom of major amputation after 12 months was 59% (SE = 11%). In six limbs, amputation was limited to a minor amputation. Seven patients (28%) died during follow-up. In conclusion, SA of the tibial arteries seem to be a valuable treatment option to prevent major amputation in patients with CLI who are facing amputation due to lack of surgical options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double-Layered PTFE-Covered Nitinol Stents: Experience in 32 Patients with Malignant Esophageal Strictures

We evaluated the effectiveness of a double-layered polytetrafluoroethylene (PTFE)-covered nitinol stent in the palliative treatment of malignant esophageal strictures. A double-layered PTFE-covered nitinol stent was designed to reduce the propensity to migration of conventional covered stent. The stent consists of an inner PTFE-covered stent and an outer uncovered nitinol stent tube. With fluoroscopic guidance, the stent was placed in 32 consecutive patients with malignant esophageal strictures. During the follow-up period, the technical and clinical success rates, complications, and cumulative patient survival and stent patency were evaluated. Stent placement was technically successful in all patients, and no procedural complications occurred. After stent placement, the symptoms of 30 patients (94%) showed improvement. During the mean follow-up of 103 days (range, 9-348 days), 11 (34%) of 32 patients developed recurrent symptoms due to tumor overgrowth in five patients (16%), tumor ingrowth owing to detachment of the covering material (PTFE) apart from the stent wire in 3 (9%), mucosal hyperplasia in 2 (6%), and stent migration in 1 (3%). Ten of these 11 patients were treated by means of placing a second covered stent. Thirty patients died, 29 as a result of disease progression and 1 from aspiration pneumonia. The median survival period was 92 days. The median period of primary stent patency was 190 days. The double-layered PTFE-covered nitinol stent seems to be effective for the palliative treatment of malignant esophageal strictures. We believe that the double-layer configuration of this stent can contribute to decreasing the stent's migration rate.

36 MATERIALS SCIENCE↗

Thirty-Day Outcome Following Carotid Artery Stenting: A 10-Year Experience from a Single Center

We aimed to present our experience with carotid angioplasty and stenting (CAS) and to document how the technique evolved over the last decade (1997-2007). A retrospective study of 333 patients (259 men; median age, 69 years) who underwent 336 CAS procedures. Of these, 118 (35%) patients were symptomatic and 164 (49%) lesions involved the left carotid bifurcation. The first 163 patients received a balloon-expandable stent, whereas the remaining 173 received a self-expandable one. Cerebral protection devices were used in the last 84 (25%) procedures. Access was via the femoral artery in all but six cases, in which direct puncture of the common carotid was necessary. The left common carotid originated from the innominate artery in 18 cases (5%). Conversion to open endarterectomy was necessary in two patients due to inability to remove the filter. Perioperative neurological events included stroke in 6 patients (1.8%), transient ischemic attack in 15 (4.5%), and hyperperfusion syndrome in 10 (3.0%). Three patients died during the first 30 days. As a result, the mortality and the combined stroke/death rate were 0.9 and 2.4%, respectively, with no differences between symptomatic and asymptomatic patients. Bradycardia was noted in 48 patients (14%), and hypotension in 45 (13%). Univariate analysis identified hypertension (P = 0.03), hyperlipidemia (P = 0.02), and current or ex-smoking (P = 0.02) as significant risk factors for death/stroke. On multivariate analysis using logistic regression, only hyperlipidemia [odds ratio (OR), 53.90; 95% confidence interval (CI), 4.19-693.47; P = 0.002] and current or ex-smoking (OR, 63.84; 95% CI,: 4.80-848.68; P = 0.001) remained statistically significant. In conclusion, CAS can be performed safely and effectively, with acceptable mortality, stroke/death, and cardiovascular complication rates. Although technological advances (stent design, cerebral protection devices), perioperative pharmacological management, and increasing experience are all clinically significant factors influencing the short-term results, none appeared to be statistically significant in this patient sample.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bland Embolization in Patients with Unresectable Hepatocellular Carcinoma Using Precise, Tightly Size-Calibrated, Anti-Inflammatory Microparticles: First Clinical Experience and One-Year Follow-Up

The purpose of this study is to report on the feasibility, local response, and 1-year clinical outcome of bland transarterial embolization (TAE) with 40- and 100-{mu}m Embozene microspheres in patients affected by unresectable hepatocellular carcinoma (HCC). Up to January 2009, 53 patients underwent superselective TAE for a total of 74 lesions. Diagnosis of HCC was based on multidetector computed tomography (MDCT), {alpha}-fetoprotein, and biopsy. MDCT was performed 24 after treatment and repeated at 1 month, 3 months, and then every 6 months. Local efficacy was defined according to RECIST criteria. Technical success was always achieved. Local results at 1-month, 3- to 6-month, and 6- to 12-month follow-up were 62%, 37%, and 16%, respectively, for stable disease and 35%, 56%, and 51%, respectively, for partial response. Complete response (no evidence of lesion) has been observed only at late follow-up (three lesions; 7%). To date, 20 of 53 patients have had at least 1 year of follow-up, with an overall survival rate of 96%. Hepatic progressive disease (i.e., new nodules) was observed in 14 of 20 patients due to underlying liver disease. Minor complications were observed in four patients. A major complication occurred in one patient, who died unexpectedly 24 h after TAE due to pulmonary embolism of necrotic pathologic tissue and passage of particles through a disrupted hepatic vein. Local results as well as 1-year clinical outcome after TAE with Embozene microspheres are veryly encouraging, however, further studies, a larger patient population, and a longer follow-up are mandatory to assess the real clinical impact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Main Bile Duct Stricture Occurring After Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

The purpose of this study was to evaluate the clinical course of main bile duct stricture at the hepatic hilum after transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Among 446 consecutive patients with HCC treated by TACE, main bile duct stricture developed in 18 (4.0%). All imaging and laboratory data, treatment course, and outcomes were retrospectively analyzed. All patients had 1 to 2 tumors measuring 10 to 100 mm in diameter (mean {+-} SD 24.5 {+-} 5.4 mm) near the hepatic hilum fed by the caudate arterial branch (A1) and/or medial segmental artery (A4) of the liver. During the TACE procedure that caused bile duct injury, A1 was embolized in 8, A4 was embolized in 5, and both were embolized in 5 patients. Nine patients (50.0%) had a history of TACE in either A1 or A4. Iodized oil accumulation in the bile duct wall was seen in all patients on computed tomography obtained 1 week later. Bile duct dilatation caused by main bile duct stricture developed in both lobes (n = 9), in the right lobe (n = 3), in the left lobe (n = 4), in segment (S) 2 (n = 1), and in S3 (n = 1). Serum levels of alkaline phosphatase and {gamma}-glutamyltranspeptidase increased in 13 patients. Biloma requiring drainage developed in 2 patients; jaundice developed in 4 patients; and metallic stents were placed in 3 patients. Complications after additional TACE sessions, including biloma (n = 3) and/or jaundice (n = 5), occurred in 7 patients and were treated by additional intervention, including metallic stent placement in 2 patients. After initial TACE of A1 and/or A4, 8 patients (44.4%), including 5 with uncontrollable jaundice or cholangitis, died at 37.9 {+-} 34.9 months after TACE, and 10 (55.6%) have survived for 38.4 {+-} 37.9 months. Selective TACE of A1 and/or A4 carries a risk of main bile duct stricture at the hepatic hilum. Biloma and jaundice are serious complications associated with bile duct strictures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intra-arterial Methylprednisolone Infusion in Treatment-Resistant Graft-Versus-Host Disease

Acute graft-versus-host disease (GVHD) is a potentially fatal complication following allogeneic hematopoietic stem cell transplant. Standard primary therapy for acute GVHD includes systemic steroids, often in combination with other agents. Unfortunately, primary treatment failure is common and carries a high mortality. There is no generally accepted secondary therapy for acute GVHD. Although few data on localized therapy for GVHD have been published, intra-arterial injection of high-dose corticosteroids may be a viable option. We treated 11 patients with steroid-resistant GVHD using a single administration of intra-arterial high-dose methylprednisolone. Three patients (27%) died periprocedurally. Four patients (36%) had a partial response to intra-arterial treatment and were discharged on total parenteral nutrition and oral medication. Four patients (36%) had a complete response and were discharged on oral diet and oral medication. No immediate treatment or procedure-related complications were noted. Twenty-seven percent of patients survived long-term. Our preliminary results suggest that regional intra-arterial treatment of steroid-resistant GVHD is a safe and potentially viable secondary therapy in primary treatment-resistant GVHD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Management of Transjugular Intrahepatic Portosystemic Shunt (TIPS)-associated Refractory Hepatic Encephalopathy by Shunt Reduction Using the Parallel Technique: Outcomes of a Retrospective Case Series

Purpose: To investigate the reproducibility and technical and clinical success of the parallel technique of transjugular intrahepatic portosystemic shunt (TIPS) reduction in the management of refractory hepatic encephalopathy (HE). Materials and Methods: A 10-mm-diameter self-expanding stent graft and a 5-6-mm-diameter balloon-expandable stent were placed in parallel inside the existing TIPS in 8 patients via a dual unilateral transjugular approach. Changes in portosystemic pressure gradient and HE grade were used as primary end points. Results: TIPS reduction was technically successful in all patients. Mean {+-} standard deviation portosystemic pressure gradient before and after shunt reduction was 4.9 {+-} 3.6 mmHg (range, 0-12 mmHg) and 10.5 {+-} 3.9 mmHg (range, 6-18 mmHg). Duration of follow-up was 137 {+-} 117.8 days (range, 18-326 days). Clinical improvement of HE occurred in 5 patients (62.5%) with resolution of HE in 4 patients (50%). Single episodes of recurrent gastrointestinal hemorrhage occurred in 3 patients (37.5%). These were self-limiting in 2 cases and successfully managed in 1 case by correction of coagulopathy and blood transfusion. Two of these patients (25%) died, one each of renal failure and hepatorenal failure. Conclusion: The parallel technique of TIPS reduction is reproducible and has a high technical success rate. A dual unilateral transjugular approach is advantageous when performing this procedure. The parallel technique allows repeat bidirectional TIPS adjustment and may be of significant clinical benefit in the management of refractory HE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cholecystostomy as a First-Line Therapy in Chronic Hemodialysis Patients with Acute Cholecystitis with Midterm Follow-up

Purpose: The purpose of this article was to share midterm results of percutaneous cholecystostomy (PC) as a first-line therapy in chronic hemodialysis patients with acute cholecystitis. Methods: Fourteen chronic hemodialysis patients with acute cholecystitis underwent PC between March 2007 and May 2009 at our institute. On preoperative assessment, the patients were classified into the ASA score by the anesthesiology team. All patients were class IV because of severe underlying comorbidities. The patients were referred to interventional radiology unit for PC by consensus of the multidisciplinary team. Results: The PC was technically successful in all the patients without minor or major complications related to the procedure. Clinical symptoms in three patients who presented with sepsis and multiorgan failure did not resolve after PC, and these patients died following urgent surgery, including open cholecystectomy and common bile duct exploration. A new cholecystitis attack was detected in one patient in the acalculous group at the sixth month of the follow-up period. The mean catheterization time was 31.7 (range, 28-41) days. The mean follow-up time was 13.3 (range 4-21) months. Conclusions: The PC may come into consideration as a first-line treatment modality in the management of acute cholecystitis in poor surgical candidate chronic hemodialysis patients. This is the first report focusing on the midterm results of PC as a first-line therapy in hemodialysis patients with acute cholecystitis who could be operated on.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lethal Hemorrhage Caused by Aortoesophageal Fistula Secondary to Stent-Graft Repair of the Thoracic Aorta

Aortoesophageal fistula (AEF) is a rare but life-threatening complication after endovascular or surgical aortic repair. Here we report a patient with AEF secondary to aortic stent-placement 2 years earlier who presented with hematemesis and died from hemorrhagic shock. By means of this case and the literature, we highlight potential bleeding sources in such a scenario because this is of crucial importance for the management strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Endovascular Treatment of Hepatic Artery Stenosis in Adult and Pediatric Patients After Liver Transplantation

The purpose of this study was to evaluate the efficacy of percutaneous endovascular techniques for the treatment of hepatic artery stenosis (HAS) occurring after liver transplantation (LT) in adult and pediatrics patients. From February 2003 to March 2009, 25 patients (15 adults and 10 children) whose developed HAS after LT were referred to our interventional radiology unit. Technical success was achieved in 96% (24 of 25) of patients. Percutaneous transluminal angioplasty (PTA) was performed in 13 patients (7 children), and stenting was performed in 11 patients (2 children). After the procedure, all patients were followed-up with liver function tests, Doppler ultrasound, and/or computed tomography. Mean follow-up was 15.8 months (range 5 days to 58 months). Acute hepatic artery thrombosis occurred immediately after stent deployment in 2 patients and was successfully treated with local thrombolysis. One patient developed severe HA spasm, which reverted after 24 h. After the procedure, mean trans-stenotic pressure gradient decreased from 30.5 to 6.2 mmHg. Kaplan-Meyer curve of HA primary patency was 77% at 1 and 2 years. During the follow-up period, 5 patients (20%) had recurrent stenosis, and 2 patients (8.3%) had late thrombosis. Two of 7 patients with stenosis/thrombosis underwent surgical revascularization (n = 1) and liver retransplantation (n = 1). Six (25%) patients died during follow-up, but overall mortality was not significantly different when comparing patients having patent hepatic arteries with those having recurrent stenosis/thrombosis. There were no significant differences in recurrent stenosis/thrombosis and mortality comparing patients treated by PTA versus stenting and comparing adult versus pediatric status. Percutaneous interventional treatment of HAS in LT recipients is safe and effective and decreases the need for surgical revascularization and liver retransplantation. However, the beneficial effects for survival are not clear, probably because the clinical complexity of many of these cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Stent Treatment for Symptomatic Benign Iliofemoral Venous Occlusive Disease: Long-Term Results 1987-2009

Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18-66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical result was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0-70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0-70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0-48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0-47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Mechanical Recanalisation of Acute Carotid-T Occlusions: A Single-Center Retrospective Analysis

Purpose: Acute carotid-T occlusion generally responds poorly to thrombolysis. Endovascular mechanical thrombectomy (EMT) seems to be a promising alternative. However, there are few data on EMT in carotid-T occlusions. Materials and Methods: We reviewed data of 14 consecutive patients with acute carotid-T occlusions treated with mechanical recanalisation devices. A clot separation/aspiration system was used in 11 patients; different other mechanical retriever devices were used in seven patients; and stents were used in four patients. Modified Rankin Scale scores at 90 days were recorded to assess functional outcome. Results: Six women and eight men were included in the study. Mean patient age was 59.2 years; median National Institute of Health Stroke Scale score on admission was 19; and mean time to treatment was 4.2 h. Successful recanalisation (Thrombolysis in Myocardial Infarction [TIMI] score II and III) was achieved in 11 patients (78.6%). Seven patients (50.0%) were treated with more than one device, leading to successful recanalisation in six of these patients (85.7%). Subarachnoid haemorrhage and large space-occupying bleedings occurred in one (7.1%) and three (21.4%) patients, respectively. At follow-up, three patients (21.4%) were functionally independent, and six (42.9%) had died. Conclusion: When applying different mechanical devices, we found a high recanalisation rate. However, discrepancy between recanalisation and clinical outcome remained. More data are needed to assess the effect of the different methods on the prognoses of stroke patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distal Pancreatectomy With En Bloc Resection of the Celiac Trunk for Extended Pancreatic Tumor Disease: An Interdisciplinary Approach

Purpose: Infiltration of the celiac trunk by adenocarcinoma of the pancreatic body has been considered a contraindication for surgical treatment, thus resulting in a very poor prognosis. The concept of distal pancreatectomy with resection of the celiac trunk offers a curative treatment option but implies the risk of relevant hepatic or gastric ischemia. We describe initial experiences in a small series of patients with left celiacopancreatectomy with or without angiographic preconditioning of arterial blood flow to the stomach and the liver. Materials and Methods: Between January 2007 and October 2009, six patients underwent simultaneous resection of the celiac trunk for adenocarcinoma of the pancreatic body involving the celiac axis. In four of these cases, angiographic occlusion of the celiac trunk before surgery was performed to enhance collateral flow from the gastroduodenal artery. Radiologic and surgical procedures, findings, and outcome were analyzed retrospectively. Results: Complete tumor removal (R0) succeeded in two patients, whereas four patients underwent R1-tumor resection. After surgery, one of the two patients without angiographic preparation experienced an ischemic stomach perforation 1 week after surgery. The other patient died from severe bleeding from an ischemic gastric ulcer. Of the four patients with celiac trunk embolization, none presented ischemic complications after surgery. Mean survival was 371 days. Conclusion: In this small series, ischemic complications after celiacopancreatectomy occurred only in those patients who did not receive preoperative celiac trunk embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa{sup Registered-Sign}, Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Acute Arterial Hemorrhage in Trauma Patients Using Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: This study was designed to determine the feasibility and efficacy of endovascular embolization with liquid embolic agent ethylene vinyl alcohol copolymer (Onyx) in patients with acute traumatic arterial bleeding. Methods: This is a retrospective review of 13 patients (9 men and 4 women; mean age 45 years) with severe trauma who underwent embolotherapy using Onyx from November 2003 to February 2009. Bleeding was located in the pelvis (5 patients), kidney (3 patients), mesenteric region (2 patients), retroperitoneal space (2 patients), neck (1 patient), and thigh (1 patient). In three cases (23.1%), Onyx was used in conjunction with coils. We evaluate the technical and clinical success, procedural and embolization time, occurrence of rebleeding, and embolotherapy-related complications, such as necrosis or migration of Onyx into nontarget vessels. Results: In all patients, embolotherapy was technically and clinically successful on the first attempt. Control of bleeding could be reached with a mean time of 19 (range, 4-63) min after correct placement of the microcatheter in the feeding artery. No recurrent bleeding was detected. No unintended necrosis or migration of Onyx into a nontarget region was observed. During the follow-up period, three patients (23.1%) died due to severe intracranial hemorrhage, cardiac arrest, and sepsis. Conclusions: Transcatheter embolization with new liquid embolic agent Onyx is technically feasible and effective in trauma patients with acute arterial hemorrhage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗