Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cryogenic electronic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

A Mechanical Cryogenic Cooler for the Hubble Space Telescope

This paper presents a description of the Hubble Space Telescope (HST) Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) Cryo Cooler (NCC), the cutting edge technology involved, its evolution, performance, and future space applications. The NCC is the primary hardware component of the NICMOS Cooling System comprised of the NCC, an Electronics Support Module, a Capillary Pumped Loop/Radiator, and associated interface harnessing. The system will be installed during extravehicular activities on HST during Servicing Mission 3B scheduled for launch in February 2002. The NCC will be used to revive the NICMOS instrument, which experienced a reduced operational lifetime due to an internal thermal short in its dewar structure, and restore HST scientific infrared capability to operational status. The NCC is a state-of-the-art reverse Turbo-Brayton cycle cooler employing gas bearing micro turbo machinery, driven by advanced power conversion electronics, operating at speeds up to 7300 revolutions per second (rps) to remove heat from the NICMOS instrument.

Jedrich, Nicholas↗

A Cryogenic Thermal Source for Detector Array Characterization

We describe the design, fabrication, and validation of a cryogenically compatible quasioptical thermal source for characterization of detector arrays. The source is constructed using a graphite-loaded epoxy mixture that is molded into a tiled pyramidal structure. The mold is fabricated using a hardened steel template produced via a wire electron discharge machining process. The absorptive mixture is bonded to a copper backplate enabling thermalization of the entire structure and measurement of the source temperature. Measurements indicate that the reflectance of the source is less than 0.001 across a spectral band extending from 75 to 330 gigahertz.

Chuss, David T.↗

Velocity Measurements in the Wake of the Swept Wing Flow Test Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

femtosecond↗

Velocity Measurements in the Wake of the Swept Wing Flow Test (SWIFT) Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

Transonic↗

An All-Solid-State, Room-Temperature, Heterodyne Receiver for Atmospheric Spectroscopy at 1.2 THz

Heterodyne receivers at submillimeter wavelengths have played a major role in astrophysics as well as Earth and planetary remote sensing. All-solid-state heterodyne receivers using both MMIC (monolithic microwave integrated circuit) Schottky-diode-based LO (local oscillator) sources and mixers are uniquely suited for long-term planetary missions or Earth climate monitoring missions as they can operate for decades without the need for any active cryogenic cooling. However, the main concern in using Schottky-diode-based mixers at frequencies beyond 1 THz has been the lack of enough LO power to drive the devices because 1 to 3 mW are required to properly pump Schottky diode mixers. Recent progress in HEMT- (high-electron-mobility- transistor) based power amplifier technology, with output power levels in excess of 1 W recently demonstrated at W-band, as well as advances in MMIC Schottky diode circuit technology, have led to measured output powers up to 1.4 mW at 0.9 THz. Here the first room-temperature tunable, all-planar, Schottky-diode-based receiver is reported that is operating at 1.2 THz over a wide (≈20%) bandwidth. The receiver front-end (see figure) consists of a Schottky-diode-based 540 to 640 GHz multiplied LO chain (featuring a cascade of W-band power amplifiers providing around 120 to 180 mW at W-band), a 200-GHz MMIC frequency doubler, and a 600-GHz MMIC frequency tripler, plus a biasable 1.2-THz MMIC sub-harmonic Schottky-diode mixer. The LO chain has been designed, fabricated, and tested at JPL and provides around 1 to 1.5 mW at 540 o 640 GHz. The sub-harmonic mixer consists of two Schottky diodes on a thin GaAs membrane in an anti-parallel configuration. An integrated metal insulator metal (MIM) capacitor has been included on-chip to allow dc bias for the Schottky diodes. A bias voltage of around 0.5 V/diode is necessary to reduce the LO power required down to the 1 to 1.5 mW available from the LO chain. The epilayer thickness and doping profiles have been specifically optimized to maximize the mixer performance beyond 1 THz. The measured DSB noise temperatures and conversion losses of the receiver are 2,000 to 3,500 K and 12 to 14 dB, respectively, at 120 K, and 4,000 to 6,000 K and 13 to 15 dB, respectively, at 300 K. These results establish the state-of-the-art for all-solid-state, all-planar heterodyne receivers at 1.2 THz operating at either room temperature or using passive cooling only. Since no cryogenic cooling is needed, the receiver is eminently suited to atmospheric heterodyne spectroscopy of the outer planets and their moons.

Siles, Jose V.↗

Spectroscopic study of the coupling effect between the two gaps of magnesium diboride on its RF properties

This program studied the two-gap nature of magnesium diboride and its possible effects on the superconducting rf properties of this material. Magnesium diboride (MgB 2 ) is a BCS superconductor with a superconducting critical temperature of 39 K, high critical current density and no weak link behavior across the grain boundary. These properties make this material ideal for both power applications and electronic devices. In particular, the high superconducting critical temperature and high thermodynamic field suggests that MgB 2 could be an ideal material also for superconducting radio frequency (SRF) cavities operating at a much higher temperature than Nb cavities and, therefore, reducing noticeably the cryogenics costs. However, MgB 2 is a two gap superconductor and it has been suggested that the RF properties are dominated by the smaller gap, which would make this material not competitive with Nb and especially Nb 3 Sn. The main problem does not seem to be the double-gap nature of this material but rather the weak-coupling of the two gaps that in the presence of an RF field suppresses superconductivity all together at fields much lower than the thermodynamic field. The main goal of this proposal is to address the fundamental question of the coupling between the two gaps in MgB 2 and understand if it is possible to control it and ultimately improve the RF performance of MgB 2 . The project studied these questions by measuring the density of states in the presence of an in-plane current and focused on the effect of controlled disorder. Disorder, indeed, provides an important knob to tune the properties of MgB2 and provides the possibility of changing the coupling between the two bands, making this material a competitive material for SRF applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Conjugated Oligoelectrolyte Exhibiting Room Temperature Spin-Correlated Radical Pair Character for Biological Sensing

We report a water-soluble conjugated oligoelectrolyte (COE) composed of carbazole-benzophenone, COE-CbzBP, that exhibits photogenerated spin-correlated radical pair (SCRP) behavior sensitive to static electric fields from DNA but not from lipid bilayers. The SCRP forms from a thermally activated, spin-polarized state enabled by partial π-conjugation disruption at the donor–acceptor (carbazole-benzophenone) nitrogen–carbon (N–C) junction, which facilitates a twisted intramolecular charge-transfer (TICT) geometry. This state minimizes the singlet–triplet energy gap (ΔE ST = 0.12 eV), radical–pair exchange coupling (J RP ∼ ΔE ST /2), and charge separation free energy (ΔG CS ) in both DNA (−0.19 eV) and lipid bilayers (−0.55 eV). Room-temperature continuous-wave electron paramagnetic resonance (CW-EPR) reveals a photogenerated spin-polarized singlet for COE-CbzBP that splits upon DNA association, consistent with modulation of J RP and hyperfine coupling (A x ), presumably via electric field-spin coupling. No spin-polarized signal was observed under dark, cryogenic conditions, or in liposomes, but was quenched by the spin trap 4-POBN. Transient absorption and spectroelectrochemistry confirmed magnetic-field sensitive long-lived excited-state absorption features attributed to charge-separated states 3 [Cbz •+ -BP •– ]*, which were lengthened by DNA, and quenched in lipid bilayers and 4-POBN. Quantum chemical simulations show that planar geometries (lipid-like) increase ΔE ST by 0.31 eV compared to TICT-optimized structures. This geometry-dependent modulation explains the absence of SCRP signatures in rigid environments, underscoring the importance of TICT states, minimized ΔE ST , and favorable ΔG CS for achieving room-temperature SCRP generation. These findings establish design principles for TICT-enabled molecules exhibiting qubit-like behavior that operate under ambient and biologically relevant conditions, with direct implications for quantum information science (QIS).

Aromatic compounds↗

Beam Induced Heating Analysis Update for the EIC Vacuum Chamber Components

One of the challenges of designing the Electron-Ion Col lider (EIC) is to mitigate beam-induced heating due to the intense electron and hadron beams. Heating of the ESR vac uum chamber components is mainly due to beam-induced resistive wall (RW) losses and synchrotron radiation. For the HSR heating is mainly due to large radial offsets and heat conduction from room temperature to cryogenic tem perature for cryo-components. In this paper, we provide an update on the beam-induced heating and thermal analysis of some critical ESR vacuum chamber components, such as the ESR Large Angle Bremhustraulung Monitor (LABM). We also provide a similar update for critical HSR vacuum com ponents, including the cryo-cooled BPM button assembly, beam screen, abort kicker, and polarimeter. To perform the thermal analyses, the resistive wall loss on individual compo nents is calculated with CST and the synchrotron radiation (if exists) is evaluated using SynRad. These losses, along with realistic boundary conditions are then fed to ANSYS to determine the temperature distribution.

43 PARTICLE ACCELERATORS↗

An integrated development facility for the calibration of low-energy charged particle flight instrumentation

A system was developed for the calibration and development of thermal ion instrumentation. The system provides an extended beam with usable current rates, approx. 1 pA/sq cm, at beam energies as low as 1 eV, with much higher values available with increasing energy. A tandem electrostatic and variable geometry magnetic mirror configuration within the ion source optimizes the use of the ionizing electrons. The system is integrated under microcomputer control to allow automatic control and monitoring of the beam energy and composition and the mass and angle-dependent response of the instrument under test. The system is pumped by a combination of carbon vane and cryogenic sorption roughing pumps and ion and liquid helium operating pumps.

Biddle, A. P.↗

Measurements of atmospheric carbonyl sulfide during the NASA Chemical Instrumentation Test and Evaluation Project: Implications for the global COS budget

Atmospheric carbonyl sulfide COS concentrations were measured by three analytical systems during the Chemical Instrumentation Test and Evaluation (CITE 3) project. The three systems all used cryogenic sample preconcentration and gas chromatographic (GC) separation but differed in the method of detection. The FPD system used a flame photometric detector, the MS system used a mass selective detector, and the ECD-S system used a fluorinating catalyst followed by an electron capture detector. With the FPD system, we found a mean COS concentration of 510 ppt over the North Atlantic and 442 ppt over the Tropical Atlantic. With the ECD-S system, we found a mean COS concentration of 489 ppt over the North Atlantic and 419 ppt over the Tropical Atlantic. All three systems registered a latitudinal gradient in atmospheric COS of between 1.6 and 2.0 ppt per degree of latitude, with increasing COS concentrations northward which was similar to the gradient measured by Bingemer et al. (1990). It is difficult to reconcile the measured latitudinal concentration gradient with present theories of the global COS budget since the largest sink of COS is thought to be a flux to land plants, most of which are in the northern hemisphere.

Johnson, James E.↗

NASA Tech Briefs, February 2001

The topics include: 1) Application Briefs; 2) National Design Engineering Show Preview; 3) Marketing Inventions to Increase Income; 4) A Personal-Computer-Based Physiological Training System; 5) Reconfigurable Arrays of Transistors for Evolvable Hardware; 6) Active Tactile Display Device for Reading by a Blind Person; 7) Program Automates Management of IBM VM Computer Systems; 8) System for Monitoring the Environment of a Spacecraft Launch; 9) Measurement of Stresses and Strains in Muscles and Tendons; 10) Optical Measurement of Temperatures in Muscles and Tendons; 11) Small Low-Temperature Thermometer With Nanokelvin Resolution; 12) Heterodyne Interferometer With Phase-Modulated Carrier; 13) Rechargeable Batteries Based on Intercalation in Graphite; 14) Signal Processor for Doppler Measurements in Icing Research; 15) Model Optimizes Drying of Wet Sheets; 16) High-Performance POSS-Modified Polymeric Composites; 17) Model Simulates Semi-Solid Material Processing; 18) Modular Cryogenic Insulation; 19) Passive Venting for Alleviating Helicopter Tail-Boom Loads; 20) Computer Program Predicts Rocket Noise; 21) Process for Polishing Bare Aluminum to High Optical Quality; 22) External Adhesive Pressure-Wall Patch; 23) Java Implementation of Information-Sharing Protocol; 24) Electronic Bulletin Board Publishes Schedules in Real Time; 25) Apparatus Would Extract Water From the Martian Atmosphere; 26) Review of Research on Supercritical vs Subcritical Fluids; 27) Hybrid Regenerative Water-Recycling System; 28) Study of Fusion-Driven Plasma Thruster With Magnetic Nozzle; 29) Liquid/Vapor-Hydrazine Thruster Would Produce Small Impulses; and 30) Thruster Based on Sublimation of Solid Hydrazine

Source record↗

Primary donor triplet states of Photosystem I and II studied by Q-band pulse ENDOR spectroscopy

The photoexcited triplet state of the “primary donors” in the two photosystems of oxygenic photosynthesis has been investigated by means of electron-nuclear double resonance (ENDOR) at Q-band (34 GHz). The data obtained represent the first set of 1 H hyperfine coupling tensors of the 3 P700 triplet state in PSI and expand the existing data set for 3 P680. We achieved an extensive assignment of the observed electron-nuclear hyperfine coupling constants (hfcs) corresponding to the methine α-protons and the methyl group β-protons of the chlorophyll (Chl) macrocycle. The data clearly confirm that in both photosystems the primary donor triplet is located on one specific monomeric Chl at cryogenic temperature. In comparison to previous transient ENDOR and pulse ENDOR experiments at standard X-band (9–10 GHz), the pulse Q-band ENDOR spectra demonstrate both improved signal-to-noise ratio and increased resolution. The observed ENDOR spectra for 3 P700 and 3 P680 differ in terms of the intensity loss of lines from specific methyl group protons, which is explained by hindered methyl group rotation produced by binding site effects. Contact analysis of the methyl groups in the PSI crystal structure in combination with the ENDOR analysis of 3 P700 suggests that the triplet is located on the Chl a' (P A ) in PSI. The results also provide additional evidence for the localization of 3 P680 on the accessory Chl D1 in PSII.

59 BASIC BIOLOGICAL SCIENCES↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

The X-ray Integral Field Unit (X-IFU) for Athena

Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics principles, some elements of the current design for the focal plane assembly and the cooling chain. We describe the current performance estimates, in terms of spectral resolution, effective area, particle background rejection and count rate capability. Finally, we emphasize on the technology developments necessary to meet the demanding requirements of the X-IFU, both for the sensor, readout electronics and cooling chain.

X-ray↗

Design and Characterization of a Phonon-Mediated Cryogenic Particle Detector with an eV-Scale Threshold and 100 keV-Scale Dynamic Range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Trofimov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an offline optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for neutrinoless β-plus-EC decay of 120 Te with CUORE

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale cryogenic experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than 130 Te. In this work we describe a search for neutrinoless positron-emitting electron capture (β + EC ) decay in 120 Te with a total TeO 2 exposure of 355.7 kg yr, corresponding to 0.2405 kg yr of 120 Te. Albeit 0νββ with two final-state electrons represents the most promising channel, the emission of a positron and two 511-keV γ 's make 0νβ + EC decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of 3.4 × 10 22 yr at 90% credibility interval (C.I.). After unblinding we find no evidence of 0νβ + EC signal and set a 90% C.I. Bayesian lower limit of 2.9 × 10 22 yr on 120 Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗