Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Codon usage revisited: Lack of correlation between codon usage and the number of tRNA genes in enterobacteria

Highlights: • Average number of tRNA genes correlate with codon usage in highly expressed genes. • Changes in the number of tRNA genes do not correlate to codon usage. • Altered tRNA gene copy numbers do not correlate to changes of codon translation. • Our data indicates that tRNA gene copies adapt to codon usage, but not the contrary. It is widely believed that if a high number of genes are found for any tRNA in a rapidly replicating bacteria, then the cytoplasmic levels of that tRNA will be high and an open reading frame containing a higher frequency of the complementary codon will be translated faster. This idea is based on correlations between the number of tRNA genes, tRNA concentration and the frequency of codon usage observed in a limited number of strains as well as from the fact that artificially changing the number of tRNA genes alters translation efficiency and consequently the amount of properly folded protein synthesized. tRNA gene number may greatly vary in a genome due to duplications, deletions and lateral transfer which in turn would alter the levels and functionality of many proteins. Such changes are potentially deleterious for fitness and as a result it is expected that changes in tRNA gene numbers should be accompanied by a modification of the frequency of codon usage. In contrast to this model, when comparing the number of tRNA genes and the frequency of codon usage of several Salmonella enterica and Escherichia coli strains we found that changes in the number of tRNA genes are not correlated to changes in codon usage. Furthermore, these changes are not correlated with a change in the efficiency of codon translation. These results suggest that once a genome gains or loses tRNA genes, it responds by modulating the concentrations of tRNAs rather than modifying its frequency of codon usage.

60 APPLIED LIFE SCIENCES↗

On falling film evaporator – A review of mechanisms and critical assessment of correlation on a horizontal tube bundle with updated development

Optimization of the energy efficiency and reduction of the greenhouse gas emission for the heat pump system is imperative to meet the net-zero goals at 2050. Chillers with falling film evaporator design not only possess better system performance but also contain less refrigerant inventory. Hence, accurate prediction of the evaporator performance is pivotal especially when charged with low-GWP refrigerant. Here, the study reviews the correlations for falling film evaporator with a horizontal tube bundle configuration. The major efforts of this study include four tasks: (a) literature review of the experimental studies and available empirical correlations; (b) comprehensive discussion of the falling film evaporation heat transfer mechanism; (c) development of a new rationally based correlation based on available literature; and (d) comparison of different correlations based on the existing data. The collected data includes 4114 data points from 8 sources, 6 refrigerants (R-600a, R-290, R-245fa, R-134a, R-1234ze(E), R-123), 5 types of the tubes (Plain, Turbo-GII-HP, GEWA-B, Low-fin, High-Flux), liquid Weber number from 2.2 × 10 –6 to 0.7, imposed vapor Weber number from 0 to 37.2, heat flux from 2.5 to 151.5 kW/m 2 , and film Reynolds number from 1 to 3159.8. The new correlation gives a MAD of 28.3%, and an R 2 of 0.86. Yet, the developed correlation considers various heat transfer mechanisms, including the transition point from falling film evaporation to the nucleate boiling, local evaporation, dry-out, mist flow, imposed flow, and enhanced tube effects.

42 ENGINEERING↗

Change in T2-Fat Saturation MRI Correlates With Outcome in Cervical Cancer Patients

Purpose: To compare pretreatment and midtreatment tumor intensity as measured by T2 fat-saturation (T2-FS) MRI and its association with treatment response in cervical cancer patients. Methods and Materials: Weekly MRI scans were performed for brachytherapy planning on 23 consecutive patients with clinical Stage IB1 to IIIB cervical cancer treated with definitive chemoradiotherapy. These scans were performed on a 1.5-T clinical scanner using a specialized pelvic coil. Mean signal intensity from T2-FS imaging was calculated for each tumor voxel. Average tumor intensity and tumor volume were recorded pre- and midtreatment (at Weeks 0 and 4). All patients subsequently underwent routine follow-up, including periodic clinical examinations and fluorodeoxyglucose-positron emission tomography imaging. Results: Mean follow-up for surviving patients was 14.5 months. Mean tumor volume at presentation was 49.6 cc, and mean midtreatment tumor volume was 16.0 cc. There was no correlation between initial tumor volume and pretreatment signal intensity (r = 0.44), nor was there a correlation between pre- or midtreatment tumor volume with disease-free survival (p = 0.18, p = 0.08 respectively.) However, having at least a 30% drop in signal intensity from pretreatment to midtreatment was correlated with having disease resolution on posttreatment fluorodeoxyglucose-positron emission tomography imaging (p = 0.05) and with disease-free survival (p = 0.03.) Estimated disease-free survival at 22 months was 100% for patients with at least a 30% drop in tumor signal intensity compared with 33% for patients above this selected threshold (p = 0.004). Conclusions: Longitudinal changes in T2-FS tumor intensity during chemoradiation correlated with disease-free survival in cervical cancer patients. Persistently high midtreatment tumor intensities correlated with a high risk of treatment failure, whereas large decreases in tumor intensity correlated with a favorable outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemo-IMRT of Oropharyngeal Cancer Aiming to Reduce Dysphagia: Swallowing Organs Late Complication Probabilities and Dosimetric Correlates

Purpose: Assess dosimetric correlates of long-term dysphagia after chemo-intensity-modulated radiotherapy (IMRT) of oropharyngeal cancer (OPC) sparing parts of the swallowing organs. Patients and Methods: Prospective longitudinal study: weekly chemotherapy concurrent with IMRT for Stages III/IV OPC, aiming to reduce dysphagia by sparing noninvolved parts of swallowing-related organs: pharyngeal constrictors (PC), glottic and supraglottic larynx (GSL), and esophagus, as well as oral cavity and major salivary glands. Dysphagia outcomes included patient-reported Swallowing and Eating Domain scores, Observer-based (CTCAEv.2) dysphagia, and videofluoroscopy (VF), before and periodically after therapy through 2 years. Relationships between dosimetric factors and worsening (from baseline) of dysphagia through 2 years were assessed by linear mixed-effects model. Results: Seventy-three patients participated. Observer-based dysphagia was not modeled because at >6 months there were only four Grade {>=}2 cases (one of whom was feeding-tube dependent). PC, GSL, and esophagus mean doses, as well as their partial volume doses (V{sub D}s), were each significantly correlated with all dysphagia outcomes. However, the V{sub D}s for each organ intercorrelated and also highly correlated with the mean doses, leaving only mean doses significant. Mean doses to each of the parts of the PCs (superior, middle, and inferior) were also significantly correlated with all dysphagia measures, with superior PCs demonstrating highest correlations. For VF-based strictures, most significant predictor was esophageal mean doses (48{+-}17 Gy in patients with, vs 27{+-}12 in patients without strictures, p = 0.004). Normal tissue complication probabilities (NTCPs) increased moderately with mean doses without any threshold. For increased VF-based aspirations or worsened VF summary scores, toxic doses (TDs){sub 50} and TD{sub 25} were 63 Gy and 56 Gy for PC, and 56 Gy and 39 Gy for GSL, respectively. For both PC and GSL, patient-reported swallowing TDs were substantially higher than VF-based TDs. Conclusions: Swallowing organs mean doses correlated significantly with long-term worsening of swallowing. Different methods assessing dysphagia resulted in different NTCPs, and none demonstrated a threshold.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Online Adaptive Hyperthermia Treatment Planning: Correlation Between Measured and Simulated Specific Absorption Rate Changes Caused by Phase Steering in Patients

Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements were performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correlative nano-imaging of metals and proteins in primary neurons by synchrotron X-ray fluorescence and STED super resolution microscopy: Experimental validation

It is becoming increasingly clear that biological metals such as iron, copper or zinc are involved in synaptic functions, and in particular in the mechanisms of synaptogenesis and subsequent plasticity. Understanding the role of metals on synaptic functions is a difficult challenge due to the very low concentration of these elements in neurons and to the submicrometer size of synaptic compartments. To address this challenge we have developed a correlative nano-imaging approach combining metal and protein detection. First, stimulated emission depletion (STED) microscopy, a super resolution optical microscopy technique, is applied to locate fluorescently labeled proteins. Then, synchrotron radiation induced X-ray fluorescence (SXRF) is performed on the same regions of interest, e.g. synaptic compartments. Here, we present here the principle scheme that allows this correlative nano-imaging and its experimental validation. We applied this correlative nano-imaging to the study of the physiological distribution of metals in synaptic compartments of primary rat hippocampal neurons. We thus compared the nanometric distribution of metals with that of synaptic proteins, such as PSD95 or cytoskeleton proteins. Compared to correlative imaging approaches currently used to characterize synaptic structures, such as electron microscopy correlated with optical fluorescence, our approach allows for ultra-sensitive detection of trace metals using highly focused synchrotron radiation beams. We provide proof-of-principle for correlative imaging of metals and proteins at the synaptic scale and discuss the present limitations and future developments in this area.

59 BASIC BIOLOGICAL SCIENCES↗

Measurement of neutron and gamma-ray cross-correlation functions with 4 He detectors

For the first time, the neutron and gamma-ray time-dependent cross-correlation distributions from spontaneous fission and (α, n) neutron sources are measured with the 4 He fast neutron detectors. The pulse shape discrimination technique based on charge comparison is utilized to discriminate between neutrons and gamma-rays in the identification of the four possible correlated pairs: (γ, γ), (n, n), (γ, n), and (n, n). Both total and individual cross-correlation functions are obtained, and their shapes can be easily distinguished among different neutron sources. The (n, n) and (γ, n) correlations are selectively analyzed and the peak position of the (n, n) and (γ, n) pairs shows a linear correlation with source-detector distance. Here, the measurements illustrate the feasibility of using 4 He detectors to identify nuclear materials and their geometrical configurations, as well as other applications in nuclear nonproliferation and safeguards. In particular, the (n, n) correlated data can be very clearly assayed even in the presence of significant gamma fields without the use of shielding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements of long-range near-side angular correlations in s N N = 5 TeV proton-lead collisions in the forward region

Two-particle angular correlations are studied in proton-lead collisions at a nucleon–nucleon centre-of-mass energy of s N N = 5 TeV , collected with the LHCb detector at the LHC. The analysis is based on data recorded in two beam configurations, in which either the direction of the proton or that of the lead ion is analysed. The correlations are measured in the laboratory system as a function of relative pseudorapidity, Δη, and relative azimuthal angle, Δφ, for events in different classes of event activity and for different bins of particle transverse momentum. In high-activity events a long-range correlation on the near side, Δφ≈0, is observed in the pseudorapidity range 2.0 < η < 4.9. This measurement of long-range correlations on the near side in proton-lead collisions extends previous observations into the forward region up to η=4.9. The correlation increases with growing event activity and is found to be more pronounced in the direction of the lead beam. However, the correlation in the direction of the lead and proton beams are found to be compatible when comparing events with similar absolute activity in the direction analysed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast Correlation Energy Estimator

A virtually no-cost method is proposed that can compute the correlation energies of general, covalently bonded, organic, and inorganic molecules (including conjugated π-electron systems) with a well-defined dominant Lewis structure at the accuracy of 99.5% of the near-exact values determined by the coupled-cluster singles, doubles, and perturbative triples [CCSD(T)] in the complete-basis-set (CBS) limit. This Correlation Energy Per Bond (CEPB) method assigns a partial correlation energy to each bond type (characterized by the identities of the two atoms forming the bond and its integer bond order) and to a lone pair, regardless of the bond length, bond angle, sp-hybridization, π-electron conjugation, ionicity, noncovalent interactions, etc. At its current stage, the method is mainly suitable for near-equilibrium geometries. The correlation energies per bond are determined by a fit to the CCSD(T)/CBS benchmarks. It can neither improve the equilibrium structures nor discern conformers or positional isomers, yet its accuracy for reaction energies rivals that of the second-order Møller–Plesset perturbation theory, which is far more expensive. Its promising performance underscores the possibility that surprisingly compact, chemically intuitive molecular fragments exist into which correlation energies can be partitioned, leading to various ultrafast correlation-energy estimators tailored to different purposes.

Binding energy↗

Strongly Correlated Ion Dynamics in Plastic Ionic Crystals and Polymerized Ionic Liquids

Understanding the mechanisms controlling ionic conductivity is critical for the development of the next generation of batteries and supercapacitors. This paper discusses the significant role played by ionic correlations in conductivity of concentrated ionic systems. Our studies of an organic ionic plastic crystal reveal that correlations in ions dynamics suppress conductivity by 25–100 times in comparison to the expected uncorrelated ionic conductivity estimated from the Nernst–Einstein relationship. Furthermore, additional analysis also demonstrates that ionic correlations suppress conductivity in polymerized ionic liquids and gel by ~10 times. Thus, ionic correlations, usually neglected in many studies, play a very important role in conductivity of concentrated ionic systems. These results cannot be explained by a diffusion of ion pairs because all these systems are essentially single ion conductors. In contrast, strongly correlated motions of mobile ions with the same charge (cation–cation or anion–anion correlations) are the major mechanism suppressing the ionic conductivity in these systems. Finally, on the basis of these results, we emphasize that charge transport rather than ion diffusion is critical for electrolyte performance and suggest the potential design of plastic crystals and polymer electrolytes with enhanced ionic conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Correlations and Partial Ionicities in the Lamellar Phases of Block Copolymeric Ionic Liquids

Recently, significant interest has arisen on the impact of dynamical ion correlations on the conductivity and transport properties of polymeric electrolyte materials. It has been hypothesized that confining ion motion to narrow channels may reduce such ion correlations and enhance the resulting ionic conductivity. Motivated by such considerations, in this study we used a multiscale simulation framework to study the dynamical ion correlations in the microphase-separated lamella phase of block copolymeric ionic liquids and compare with the corresponding results for homopolymeric systems. We probed the influence of ion correlations through the partial ionicity, Δ, which quantifies the ratio of true conductivity to the ideal, Nernst–Einstein conductivity for the anion-related contributions. Consistent with our original hypothesis, our results demonstrate that the partial ionicity relating to the mobile anions is much larger in the lamella phases of block copolymers compared to that in homopolymers. Analysis of the distinct conductivity contributions demonstrates that such results arise as a result of an intricate compensation among the nonideal dynamical correlations relating to anions in lamella phases. Overall, our results suggest that self-assembled phases of block copolymers may provide an avenue to tune the dynamical ion correlations in polymer electrolyte systems.

36 MATERIALS SCIENCE↗

Genetic correlation network prediction of forest soil microbial functional organization

Soil ecological functions are largely determined by the activities of soil microorganisms, which, in turn, are regulated by relevant interactions between genes and their corresponding pathways. Therefore, the genetic network can theoretically elucidate the functional organization that supports complex microbial community functions, although this has not been previously attempted. We generated a genetic correlation network based on 5421 genes derived from metagenomes of forest soils, identifying 7191 positive and 123 negative correlation relationships. This network consisted of 27 clusters enriched with sets of genes within speci fi c functions, represented with corresponding cluster hubs. The clusters revealed a hierarchical architecture, re fl ecting the functional organization in the soil metagenomes. Positive correlations mapped functional associations, whereas negative correlations often mapped regulatory processes. The potential functions of uncharacterized genes were predicted based on the functions of located clusters. The global genetic correlation network highlights the functional organization in soil metagenomes and provides a resource for predicting gene functions. We anticipate that the genetic correlation network may be exploited to comprehensively decipher soil microbial commu

54 ENVIRONMENTAL SCIENCES↗

Tuning moiré excitons and correlated electronic states through layer degree of freedom

Moiré coupling in transition metal dichalcogenides (TMDCs) superlattices introduces flat minibands that enable strong electronic correlation and fascinating correlated states, and it also modifies the strong Coulomb-interaction-driven excitons and gives rise to moiré excitons. Here, we introduce the layer degree of freedom to the WSe 2 /WS 2 moiré superlattice by changing WSe 2 from monolayer to bilayer and trilayer. We observe systematic changes of optical spectra of the moiré excitons, which directly confirm the highly interfacial nature of moiré coupling at the WSe 2 /WS 2 interface. In addition, the energy resonances of moiré excitons are strongly modified, with their separation significantly increased in multilayer WSe 2 /monolayer WS 2 moiré superlattice. The additional WSe 2 layers also modulate the strong electronic correlation strength, evidenced by the reduced Mott transition temperature with added WSe 2 layer(s). The layer dependence of both moiré excitons and correlated electronic states can be well described by our theoretical model. Our study presents a new method to tune the strong electronic correlation and moiré exciton bands in the TMDCs moiré superlattices, ushering in an exciting platform to engineer quantum phenomena stemming from strong correlation and Coulomb interaction.

36 MATERIALS SCIENCE↗

Emergence of flat bands and ferromagnetic fluctuations via orbital-selective electron correlations in Mn-based kagome metal

Kagome lattice has been actively studied for the possible realization of frustration-induced two-dimensional flat bands and a number of correlation-induced phases. Currently, the search for kagome systems with a nearly dispersionless flat band close to the Fermi level is ongoing. Here, by combining theoretical and experimental tools, we present Sc 3 Mn 3 Al 7 Si 5 as a novel realization of correlation-induced almost-flat bands in the kagome lattice in the vicinity of the Fermi level. Our magnetic susceptibility, 27 Al nuclear magnetic resonance, transport, and optical conductivity measurements provide signatures of a correlated metallic phase with tantalizing ferromagnetic instability. Our dynamical mean-field calculations suggest that such ferromagnetic instability observed originates from the formation of nearly flat dispersions close to the Fermi level, where electron correlations induce strong orbital-selective renormalization and manifestation of the kagome-frustrated bands. In addition, a significant negative magnetoresistance signal is observed, which can be attributed to the suppression of flat-band-induced ferromagnetic fluctuation, which further supports the formation of flat bands in this compound. These findings broaden a new prospect to harness correlated topological phases via multiorbital correlations in 3d-based kagome systems.

36 MATERIALS SCIENCE↗

Correlated energy uncertainties in reaction rate calculations

Monte Carlo methods can be used to evaluate the uncertainty of a reaction rate that arises from many uncertain nuclear inputs. However, until now no attempt has been made to find the effect of correlated energy uncertainties in input resonance parameters. Our goal is to investigate the impact of correlated resonance energy uncertainties on reaction rates. Using a combination of numerical and Monte Carlo variation of resonance energies, the effect of correlations are investigated. Five reactions are considered: two fictional, illustrative cases and three reactions whose rates are of current interest. The effect of correlations in resonance energies depends on the specific reaction cross section and temperatures considered. When several resonances contribute equally to a reaction rate, and when they are located on either side of the Gamow peak, correlations between their energies dilute their effect on reaction rate uncertainties. If they are both located above or below the maximum of the Gamow peak, however, correlations between their resonance energies can increase the reaction rate uncertainties. This effect can be hard to predict for complex reactions with wide and narrow resonances contributing to the reaction rate.

79 ASTRONOMY AND ASTROPHYSICS↗

ConKer: An algorithm for evaluating correlations of arbitrary order

Context. High order correlations in the cosmic matter density have become increasingly valuable in cosmological analyses. However, computing these correlation functions is computationally expensive. Aims. We aim to circumvent these challenges by developing a new algorithm called ConKer for estimating correlation functions. Methods. This algorithm performs convolutions of matter distributions with spherical kernels using FFT. Since matter distributions and kernels are defined on a grid, it results in some loss of accuracy in the distance and angle definitions. We study the algorithm setting at which these limitations become critical and suggest ways to minimize them. Results. ConKer is applied to the CMASS sample of the SDSS DR12 galaxy survey and corresponding mock catalogs, and is used to compute the correlation functions up to correlation order n = 5. We compare the n = 2 and n = 3 cases to traditional algorithms to verify the accuracy of the new algorithm. We perform a timing study of the algorithm and find that three of the four distinct processes within the algorithm are nearly independent of the catalog size N , while one subdominant component scales as O ( N ). The dominant portion of the calculation has complexity of O ( N c 4/3 log N c ), where N c is the of cells in a three-dimensional grid corresponding to the matter density. Conclusions. We find ConKer to be a fast and accurate method of probing high order correlations in the cosmic matter density, then discuss its application to upcoming surveys of large-scale structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient antisymmetrization algorithm for the partially correlated wave functions in the free complement-local Schrödinger equation method

We propose here fast antisymmetrization procedures for the partially correlated wave functions that appear in the free complement-local Schrödinger equation (FC-LSE) method. Pre-analysis of the correlation diagram, referred to as dot analysis, combined with the determinant update technique based on the Laplace expansion, drastically reduces the orders of the antisymmetrization computations. When the complement functions include only up to single-correlated terms, the order of computations is O(N{sup 3}), which is the same as the non-correlated case. Similar acceleration is obtained for general correlated functions as a result of dot analysis. This algorithm has been successfully used in our laboratory in actual FC-LSE calculations for accurately solving the many-electron Schrödinger equations of atoms and molecules. The proposed method is general and applicable to the sampling-type methodology of other partially correlated wave functions like those in the quantum Monte Carlo and modern Hylleraas-type methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum correlation of path-entangled two-photon states in waveguide arrays with defects

We study the quantum correlation of path-entangled states of two photons in coupled one-dimensional waveguide arrays with lattice defects. Both off-diagonal and diagonal defects are considered, which show different effects on the quantum correlation of path-entangled two-photon states. Two-photon bunching or anti-bunching effects can be observed and controlled. The two photons are found to have a tendency to bunch at the side lobes with a repulsive off-diagonal defect, and the path-entanglement of the input two-photon state can be preserved during the propagation. We also found that defect modes may play an important role on the two-photon correlation of path-entangled states in the waveguide arrays. Due to the quantum interference effect, intriguing evolution dynamics of the two-photon correlation matrix elements with oscillation frequencies being either twice of or the same as that of a classical light wave, depending on the position of the correlation matrix element, is observed. Our results show that it is possible to manipulate the two-photon correlation properties of path-entangled states in waveguide arrays with lattice defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗