Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Six degree of freedom fine motion positioning stage based on magnetic levitation

The design of a magnetically suspended six degree of freedom positioning system capable of nanometer positioning is presented. The sample holder is controlled in six degrees of freedom (DOF) over 300 micrometers of travel in the X, Y, and Z directions. A design and control summary and test results indicating stability and power dissipation are included in the paper. The system is vacuum compatible, uses commercially available materials, and requires minimal assembly and setup.

Arling, R. W.↗

Apparatus for performing high-temperature fiber push-out testing

The apparatus disclosed in the present invention measures the force at which a fiber resist the motion of an indenter driven at constant speed. This apparatus conducts these test in a vacuum of about 10(exp -6) tort and at temperatures up to 1100 C. Temperature and vacuum environment are maintained while controlling indenter motion, sample position, and providing magnified visual inspection during the test.

Eldridge, Jeffrey I.↗

Can salt on an optical rain gauge lens affect performance?

The optical rain gauge (ORG) by ScTI is designed to be tolerant to reduction of infrared beam intensity due to a dirty lens. Recently there is interest in long term use of optical gauges onboard buoys at sea. Because of logistics, these systems are serviced infrequently, i.e., every several months. Due to the proximity of the gauges to the sea surface, salt can be expected to be deposited on the lens. To obtain an indication of the potential for dirty lens to affect the ORG calibration, two simple experiments were conducted. In the control experiment, a sample ORG was compared to three other ORG's during natural rain events. Next a translucent mask was placed on the transmitter lens of the sample ORG and again data were collected under natural rain conditions. The mask reduced the gain of the perturbed ORG by about 30%. The perturbed ORG operated rather well in that the mask only causes a change in the gain and does not cause data drop out at low rain rates. However, the reduced gain would seriously impact an assessment of rain statistics.

Bliven, Larry F.↗

Highlights of the Zeno Results from the USMP-2 Mission

The Zeno instrument, a High-precision, light-scattering spectrometer, was built to measure the decay rates of density fluctuations in xenon near its liquid-vapor critical point in the low-gravity environment of the U.S. Space Shuttle. Eliminating the severe density gradients created in a critical fluid by Earth's gravity, we were able to make measurements to within 100 microKelvin of the critical point. The instrument flew for fourteen days in March, 1994 on the Space Shuttle Columbia, STS-62 flight, as part of the very successful USMP-2 payload. We describe the instrument and document its performance on orbit, showing that it comfortably reached the desired 3 microKelvin temperature control of the sample. Locating the critical temperature of the sample on orbit was a scientific challenge; we discuss the advantages and short-comings of the two techniques we used. Finally we discuss problems encountered with making measurements of the turbidity of the sample, and close with the results of the measurement of the decay rates of the critical-point fluctuations.

Gammon, Robert W.↗

Evaluation of Thermal Control Coatings and Polymeric Materials Exposed to Ground Simulated Atomic Oxygen and Vacuum Ultraviolet Radiation

Numerous thermal control and polymeric samples with potential International Space Station applications were evaluated for atomic oxygen and vacuum ultraviolet radiation effects in the Princeton Plasma Physics Laboratory 5 eV Neutral Atomic Oxygen Facility and in the MSFC Atomic Oxygen Drift Tube System. Included in this study were samples of various anodized aluminum samples, ceramic paints, polymeric materials, and beta cloth, a Teflon-impregnated fiberglass cloth. Aluminum anodizations tested were black duranodic, chromic acid anodize, and sulfuric acid anodize. Paint samples consisted of an inorganic glassy black paint and Z-93 white paint made with the original PS7 binder and the new K2130 binder. Polymeric samples evaluated included bulk Halar, bulk PEEK, and silverized FEP Teflon. Aluminized and nonaluminized Chemfab 250 beta cloth were also exposed. Samples were evaluated for changes in mass, thickness, solar absorptance, and infrared emittance. In addition to material effects, an investigation was made comparing diffuse reflectance/solar absorptance measurements made using a Beckman DK2 spectroreflectometer and like measurements made using an AZ Technology-developed laboratory portable spectroreflectometer.

Kamenetzky, R. R.↗

Stratospheric Sulfuric Acid and Black Carbon Aerosol Measured During POLARIS and its Role in Ozone Chemistry

Stratospheric aerosol can affect the environment in three ways. Sulfuric acid aerosol have been shown to act as sites for the reduction of reactive nitrogen and chlorine and as condensation sites to form Polar Stratospheric Clouds, under very cold conditions, which facilitate ozone depletion. Recently, modeling studies have suggested a link between BCA (Black Carbon Aerosol) and ozone chemistry. These studies suggest that HNO3, NO2, and O3 may be reduced heterogeneously on BCA particles. The ozone reaction converts ozone to oxygen molecules, while HNO3 and NO2 react to form NOx. Finally, a buildup of BCA could reduce the single-scatter albedo of aerosol below a value of 0.98, a critical value that has been postulated to change the effect of stratospheric aerosol from cooling to warming. Correlations between measured BCA amounts and aircraft usage have been reported. Attempts to link BCA to ozone chemistry and other stratospheric processes have been hindered by questions concerning the amount of BCA that exists in the stratosphere, the magnitude of reaction probabilities, and the scarcity of BCA measurements. The Ames Wire Impactors (AWI) participated in POLARIS as part of the complement of experiments on the NASA ER-2. One of our main objectives was to determine the amount of aerosol surface area, particularly BCA, available for reaction with stratospheric constituents and assess if possible, the importance of these reactions. The AWI collects aerosol and BCA particles on thin Palladium wires that are exposed to the ambient air in a controlled manner. The samples are returned to the laboratory for subsequent analysis. The product of the AWI analysis is the size, surface area, and volume distributions, morphology and elemental composition of aerosol and BCA. This paper presents results from our experiments during POLARIS and puts these measurements in the context of POLARIS and other missions in which we have participated. It describes modifications to the AWI data analysis procedures in which the collection of BCA is modeled as a fractal aggregate. The new analysis results in an increase in BCA surface area of approximately 24 and an increase in mass of 7-10 from the previous method. For the current study, BCA surface area is used in computer models that attempt to predict measured NOx/NOy ratios and O3 depletion rates. Inclusion of the HNO3 reaction with BCA in one model tends to improve the agreement of calculated to measured NOx/NOy ratio. However, it was found that these trends are viable only if the reactions are catalytic.

Strawa, Anthony W.↗

Gentamicin: effect on E. coli in space

Previous investigations have shown that liquid bacterial cultures grown in space flight were not killed as effectively by antibiotic treatments as were cultures grown on Earth. However, the cause for the decreased antibiotic effectiveness remains unknown. Possible explanations include modified cell proliferation and modified antibiotic transport in the culture medium. Escherichia coli cultures were grown in space flight (STS-69 and STS-73), with and without gentamicin, on a solid agar substrate thus eliminating fluid effects and reducing the unknowns associated with space-flight bacterial cultures in suspension. This research showed that E. coli cultures grown in flight on agar for 24 to 27 hours experienced a heightened growth compared to simultaneous controls. However, addition of gentamicin to the agar killed the bacteria such that both flight and ground control E. coli samples had similar final cell concentrations. Therefore, while the reported existence of a decrease in antibiotic effectiveness in liquid cultures remains unexplained, these data suggest that gentamicin in space flight was at least as effective as, if not more effective than, on Earth, when E. coli cells were grown on agar.

STS-69 Shuttle Project↗

Brassica rapa plants adapted to microgravity with reduced photosystem I and its photochemical activity

The photosynthetic apparatus contains several protein complexes, many of which are regulated by environmental conditions. In this study, the influences of microgravity on PSI and PSII in Brassica rapa plants grown aboard the space shuttle were examined. We found that Brassica plants grown in space had a normal level of growth relative to controls under similar conditions on Earth. Upon return to Earth, cotyledons were harvested and thylakoid membranes were isolated. Analysis of chlorophyll contents showed that the Chl a/b ratio (3.5) in flight cotyledons was much higher than a ratio of 2.42 in the ground controls. The flight samples also had a reduction of PSI complexes and a corresponding 30% decrease of PSI photochemical activity. Immunoblotting showed that the reaction centre polypeptides of PSI were more apparently decreased (e.g. by 24-33% for PsaA and PsaB, and 57% for PsaC) than the light-harvesting complexes. In comparison, the accumulation of PSII complex was less affected in microgravity, thus only a slight reduction in D1, D2 and LHCII was observed in protein blots. However, there was a 32% decrease of OEC1 in the flight samples, indicating a defective OEC subcomplex. In addition, an average 54% increase of the 54 kDa CF1-beta isoform was found in the flight samples, suggesting that space-grown plants suffered from certain stresses, consistent with implications of the increased Chl a/b ratio. Taken together, the results demonstrated that Brassica plants can adapt to spaceflight microgravity, but with significant alterations in chloroplast structures and photosynthetic complexes, and especially reduction of PSI and its activity.

Non-NASA Center↗

Directional spectral emissivity measurement system

Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

Halyo, Nesim↗

Preliminary Evaluation of Commercial Off the Shelf (COTS) Packing Materials for Flight Medication Dispenser (FMD) Technology Development

With the advent of longer duration space missions, pharmaceutical use in space has increased. During the first 33 space shuttle missions, crew members took more than 500 individual doses of 31 different medications . Anecdotal reports from crew members described medications as generally "well tolerated" and "effective". However, reported use of increased medication doses and discrepancies in ground vs. flight efficacy may result from reduced potency or altered bioavailability due to changes in chemical and/or physical parameters of pharmaceutical stability. Based on preliminary results from a ground-based irradiation and an inflight study on pharmaceutical stability, three susceptible medications, Amoxicillin/Clavulanate and Sulfamethoxazole/trimethoprim antibiotics tablets and promethazine (PMZ), an antihistamine were selected for testing using two types of Oliver-Tolas bags, TPC-1475(Clear) and TPF-0599B (Foil) for radiation Shielding effectiveness. The material composition of the bags included aluminum coated Mylar sheathing coated with multifunctional nanocomposities based on polyethylene with dispersed boron-rich nanophases. Two bags of each medication were irradiated for different time intervals with 14.6 rad/min to achieve 0.1 Gy, 1 Gy and 10 Gy of cumulative radiation dose. Active pharmaceutical content (API) in each medication was determined and results analyzed. No significant difference in API content was observed between control and irradiated samples for both antibiotic tablets suggesting both types of bags may offer protection against gamma radiation; results with PMZ were inconclusive. These preliminary results suggest that Oliver-Tolas TPL-1475 and TPF-0599B materials may possess characteristics suitable for protection against ionizing radiation and can be considered for designing and further testing of FMD technology.

Du, Brian↗

ITCS Test Strip Development and Certification

Internal coolant loops used for International Space Station thermal control must be periodically monitored for system health, including pH, biocide levels and any indication of ammonia. The presence of ammonia, possible via a microleak in the interface between the internal and external thermal control systems, could be a danger to the crew. The Internal Thermal Control System (ITCS) Sampling Kit uses test strips as a colorimetric indicator of pH and concentrations of biocide and free ammonia. This paper describes the challenges in designing an ammonia colorimetric indicator in a variable pH environment, as well as lessons learned, ultimately resulting in a robust test strip to indicate a hazardous ammonia leak.

Carrigan, Caitlin↗

Laser Mode Behavior of the Cassini CIRS Fourier Transform Spectrometer at Saturn

The CIRS Fourier transform spectrometer aboard the NASA/ESA/ASI Cassini orbiter has been acquiring spectra of the Saturnian system since 2004. The CIRS reference interferometer employs a laser diode to trigger the interferogram sampling. Although the control of laser diode drive current and operating temperature are stringent enough to restrict laser wavelength variation to a small fraction of CIRS finest resolution element, the CIRS instrument does need to be restarted every year or two, at which time it may start in a new laser mode. By monitoring the Mylar absorption features in uncalibrated spectra due to the beam splitter Mylar substrate, it can be shown that these jumps are to adjacent modes and that most of the eight-year operation so far is restricted to three adjacent modes. For a given mode, the wavelength stability appears consistent with the stability of the laser diode drive curren.t and operating temperature.

Brasunas, John C.↗

Update of Bisphosphonate Flight Experiment

Elevated bone resorption is a hallmark of human spaceflight and bed rest indicating that elevated remodeling is a major factor in the etiology of space flight bone loss. In a collaborative effort between the NASA and JAXA space agencies, we are testing whether an antiresorptive drug would provide additional benefit to in-flight exercise to ameliorate bone loss and hypercalciuria during long-duration spaceflight. Measurements of bone loss include DXA, QCT, pQCT, urinary and blood biomarkers. We have completed analysis of R+1year data from 7 crewmembers treated with alendronate during flight, as well as immediate post flight (R+<2wks) data from 6 of 10 concurrent controls without treatment. The treated astronauts used the Advanced Resistive Exercise Device (ARED) during their missions. The purpose of this report is twofold: 1) to report the results of inflight, post flight and one year post flight bone measures compared with available controls with and without the use of ARED; and 2) to discuss preliminary data on concurrent controls. The figure below compares the BMD changes in ISS crewmembers exercising with and without the current ARED protocol and the alendronate treated crewmembers also using the ARED. This shows that the use of ARED prevents about half the bone loss seen in early ISS crewmembers and that the addition of an antiresorptive provides additional benefit. Resorption markers and urinary Ca excretion are not impacted by exercise alone but are significantly reduced with antiresorptive treatment. Bone measures for treated subjects, 1 year after return from space remain at or near baseline. DXA data for the 6 concurrent controls using the ARED device are similar to DXA data shown in the figure below. QCT data for these six indicate that the integral data are consistent with the DXA data, i.e., comparing the two control groups suggests significant but incomplete improvement in maintaining BMD using the ARED protocol. Biochemical data of the concurrent control group await sample return and analysis. The preliminary conclusion is that an antiresorptive may be an effective adjunct to exercise during long-duration spaceflight.

LeBlanc, A.↗

Bionutrients-1, On-Demand Production of Nutrients in Space

Future long-duration missions face significant challenges maintaining crew health. A critical area is supplying adequate nutrition, as certain vitamins and nutrients in supplied foods and supplements demonstrate substantial degradation during extended storage. To address this issue, we are developing and flight-testing a platform technology that demonstrates in situ microbial production of targeted nutrients over extended mission durations. This 5-year experiment, known as BioNutrients-1, was started on the International Space Station in May 2019. It involves two components: an on-orbit hydration and production experiment; and the development of space-compatible, key bio-manufacturing microorganisms. On-orbit testing utilizes a small “production pack” system that encloses sterile edible growth substrate and desiccated Saccharomyces cerevisiae strains genetically engineered to produce the nutrients beta-carotene or zeaxanthin. On hydration and mixing of the production pack, the organisms revive and grow until limited by the depletion of growth media, hypothetically leading to consistent amounts of biomass and nutrients. In eventual mission applications, the packet contents would be heat treated to inactivate the microorganisms prior to consumption. For these flight experiments, the packet will not be heat treated, but will instead be frozen for return to Earth for analyses. In addition to the production pack trials, 14 different microorganisms/treatments were also delivered to ISS for long-duration storage. These samples will be intermittently returned to Earth and analyzed to determine survival rates and genomics. For this presentation, initial data from returned samples and ground controls will be discussed.

Hindupur, Aditya↗

BioNutrients-1: On-Demand Production of Nutrients in Space

Future long-duration missions face significant challenges maintaining crew health. A critical area is supplying adequate nutrition, as certain vitamins and nutrients in supplied foods and supplements demonstrate substantial degradation during extended storage. To address this issue, we are developing and flight-testing a platform technology that demonstrates in situ microbial production of targeted nutrients over extended mission durations. This 5-year experiment, known as BioNutrients-1, was started on the International Space Station in May 2019. It involves two components: an on-orbit hydration and production experiment; and the development of space-compatible, key bio-manufacturing microorganisms. On-orbit testing utilizes a small "production pack" system that encloses sterile edible growth substrate and desiccated Saccharomyces cerevisiae strains genetically engineered to produce the nutrients beta-carotene or zeaxanthin. On hydration and mixing of the production pack, the organisms revive and grow until limited by the depletion of growth media, hypothetically leading to consistent amounts of biomass and nutrients. In eventual mission applications, the packet contents would be heat treated to inactivate the microorganisms prior to consumption. For these flight experiments, the packet will not be heat treated, but will instead be frozen for return to Earth for analyses. In addition to the production pack trials, 14 different microorganisms/treatments were also delivered to ISS for long-duration storage. These samples will be intermittently returned to Earth and analyzed to determine survival rates and genomics. For this presentation, initial data from returned samples and ground controls will be discussed.

Hindupur, Aditya↗

Solid Fuel Ignition and Extinction (SoFIE) Project on ISS

The Solid Fuel Ignition and Extinction (SoFIE) project studies ignition and flammability of solid spacecraft materials (fuels) in practical geometries and realistic atmospheric conditions. It is an experiment insert designed for use within the existing Combustion Integrated Rack (CIR). The CIR chamber provides a level of containment and permits testing at variable oxygen concentrations and pressures representative of current and planned NASA Space Exploration Atmospheres. The applications of SoFIE include: (1) Determining safer selection of cabin materials and validating NASA materials flammability selection using 1-g test protocols for low-gravity fires, (2) Improving understanding of early fire growth behavior, (3) Validating material flammability numerical models, (4) Determining optimal suppression techniques for burning materials by diluents, flow reduction, and venting, (5) Obtaining burning behavior of actual engineering materials planned for spacecraft, (6) Developing corresponding models of microgravity flame spread, flammability, and extinction, and use the results to improve normal gravity combustion models for terrestrial applications. The hardware permits a wide range of solid-material combustion and fire suppression studies. It supports multiple investigations using common infrastructure including sample holders, flow control, test sections, external radiant heaters, igniters, and diagnostics. SoFIE has been developed to meet the requirements of five unique investigations. It is currently being built and slated to begin operations on the ISS in July 2021. Given the general capabilities of the hardware insert, it is intended to be used as a facility for future researchers who can propose to NASA for related solid combustion studies.

Ferkul, Paul↗

Virus Infection of Phytoplankton Increases Average Molar Mass and Reduces Hygroscopicity of Aerosolized Organic Matter

Viral infection of phytoplankton is a pervasive mechanism of cell death and bloom termination, which leads to the production of dissolved and colloidal organic matter that can be aerosolized into the atmosphere. Earth-observing satellites can track the growth and death of phytoplankton blooms on weekly time scales but the impact of viral infection on the cloud forming potential of associated aerosols is largely unknown. Here, we determine the influence of viral-derived organic matter, purified viruses, and marine hydrogels on the cloud condensation nuclei activity of their aerosolized solutions, compared to organic exudates from healthy phytoplankton. Dissolved organic material derived from exponentially growing and infected cells of well-characterized eukaryotic phytoplankton host-virus systems, including viruses from diatoms, coccolithophores and chlorophytes, was concentrated, desalted, and nebulized to form aerosol particles composed of primarily of organic matter. Aerosols from infected phytoplankton cultures resulted in an increase in critical activation diameter and average molar mass in three out of five combinations evaluated, along with a decrease in organic kappa (hygroscopicity) compared to healthy cultures and seawater controls. The infected samples also displayed evidence of increased surface tension depression at realistic cloud water vapor supersaturations. Amending the samples with xanthan gum to simulate marine hydrogels increased variability in organic kappa and surface tension in aerosols with high organic to salt ratios. Our findings suggest that the pulses of increased dissolved organic matter associated with viral infection in surface waters may increase the molar mass of dissolved organic compounds relative to surface waters occupied by healthy phytoplankton or low phytoplankton biomass.

Atmospheric science↗

The BioSensor Instrument Beyond LEIA: a Versatile Platform for Lunar Biology

Introduction: The BioSensor is a deep-space-compatible automated microfluidic culturing instrument. While originally designed to measure the effects of deep space radiation on yeast growth for the BioSentinel mission, it has the potential to host a diverse range of life science experiments with single- and/or multi-celled organisms and can be adapted to interface with a diverse range of platforms in both crewed and uncrewed settings. It is therefore a leading candidate for hosting life sciences experimentation associated with a lunar surface habitat. BioSensor design: The function of the BioSensor is to monitor the growth and metabolic activity of samples in batch fluidic culture, without the need for crew involvement. The current configuration houses organisms in 16 wells within 16 microfluidic cards, accommodating a total of 256 samples, replicates, and controls. Each well has an optical system including three LEDs and a photodiode detector to measure absorbance at three wavelengths, enabling measurement of optical density, color change in dyes such as alamarBlue, and bioproduction of pigmented compounds. Organisms are loaded into fluidic wells and air-dried for storage during integration, launch, and transit, then activated by the introduction of culture medium from storage bags via manifolds that fill one card at a time. Temperature is controlled by individual card heaters, and timing of all activities (fluidics fills, optical measurements, temperatures) is directed by an experiment script. The self-contained BioSensor payload is roughly 4U in volume; with electrical/mechanical/thermal interface, e.g. for operation on ISS or a lunar lander, as well as a linear energy-transfer (LET) charged-particle radiation spectrometer, the entire system is closer to 6U. BioSentinel and LEIA: Flown on the ISS and in a deep-space free flyer for BioSentinel, the BioSensor has been modified for use in the LEIA mission, including improvements to reduce the sensitivity to lengthy launch delays. LEIA will monitor yeast growth in the radiation and reduced-gravity environment of the lunar surface no earlier than 2026, on a CLPS lander [4]. Changes include accommodating additional culture media and an additional LED color for a new biological assay (bioproduction of carotenoids-- dietary antioxidants), as well as modifications to the housing to allow late-load biology changeout and improved isolation between fluidics and electronics. Future prospects: Future work with the BioSensor, beyond LEIA, will include expanding the range and diversity of organisms and assays accommodated. Preliminary work has demonstrated the growth of Arabidopsis seedlings in BioSensor fluidic cards, including optical measurements of growth rate over time. Minor modifications could allow measurement of phenotypes related to photosynthetic capacity in both plants and cyanobacteria. The experimental capabilities of the BioSensor could be dramatically increased by introducing the capability for fluorescence measurements, and/or the design of novel biological assays using luminescence. The BioSensor can also be adapted for new platforms and experiment settings; in addition to free-flyer, ISS, and CLPS lander, a preliminary design concept has been developed for crewed deployment directly to the lunar surface. The instrument could be accommodated inside a lunar habitat, where its automated operation would make it an excellent candidate for experiments from fundamental investigations into the response of organisms to lunar surface conditions to applied-science purposes such as screening engineered strains of various organisms for bioproduction capability.

J A Lee↗