Computerized procedure systems: procedure edition and maintenance challenges - 232

Very few nuclear power plants are using computerized procedures to guide the control room operation. A CPS implementation consists of two processes: digitalization and computerization. The former deals with the transformation of paper-based procedure into a digital data; the latter is referred to as the addition to that data of extra information that is meaningful for decision-making. This information may include real-time data (plant parameter values and binary process values to indicate equipment states), provide access to trends and historical data, etc. In order to be efficient and to optimize the digitalization and computerization processes, these set of aids should be implemented at the same time as operating procedures are digitalized There are references of plants having successfully implemented Computerized Procedures Systems (CPS) for emergency procedures, but when questioned about normal or abnormal operating procedures, operators and plant management seem reluctant to take that step. Given that a CPS is meant, by design concept, to increase operation crew efficiency by facilitating the procedures execution and reducing human error, why are we reluctant to enjoy CPS benefits in the most common plant status (i.e. normal operation)? Although there are many answers to this question, one is shared by most of the users: CPSs are not designed for editing and maintaining procedures easily and reliably. Normal operating procedures, in opposition to the emergency procedures, are often reviewed. Nowadays, these edition activities are performed easily with a word processor software and using paper, but what is required when dealing with a CPS? (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developmental study of advanced HIS design method for digital I and C+HMIT of PWR plant - 277

A new conceptual frame of how to design and validate a digital HIS (human interface system) on an innovative numerical simulation basis is proposed for the support of plant operators' supervisory control of various types of automated complex NPPs (nuclear power plants). The proposed conceptual framework utilizes the object-oriented software for plant DiD (defense-in depth) risk monitor with the combination of nuclear reactor accident simulation by an advanced nuclear safety analysis code RELAP5/MOD4. The conceptual frame proposed in this paper will be applied for an example practice for the SBLOCA (small break loss of coolant accident) case of passive safety PWR (pressurized water reactor) AP1000. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Human Factors Principles in Information Dashboard Design - 278

Refueling outages remain one of the largest opportunities for improving capacity factor and reducing costs available to commercial nuclear power plants. Although the nuclear industry has made steady improvement in outage optimization, each day of a refueling outage still represents an opportunity to save millions of dollars and each day an outage extends past its planned end date represents millions of dollars that may have been spent unnecessarily. Reducing planned outage duration or preventing outage extensions requires careful management of the outage schedule as well as constant oversight and monitoring of work completion during the outage execution. During a typical outage, there are typically more than 10,000 activities on the schedule that, if not managed efficiently, may cause expensive outage delays. Management of outages currently relies largely on paper-based resources and general-purpose office software. A typical method currently used to monitor work performance is a burn-down curve, where total remaining activities are plotted against the baseline schedule to track bulk work completion progress. While methods like this are useful, there is still considerable uncertainty during a typical outage whether bulk work progress is adequate and therefore a lot of management time is spent analyzing the situation on a daily basis. This paper is a case study of how new technology, in combination with established human-factors and user-centered design knowledge, can be used to support Outage Control Center (OCC) personnel decision making. In particular, we describe recent advances made in developing a framework for the design of visual outage information presentation, as well as an overview of the human factors principles that informed the development of the visualizations. To test the utility of advanced visual outage information presentation, an outage management dashboard software application was created as part of the Department of Energy's Advanced Outage Control Center project (AOCC). This dashboard is intended to present all the critical information an outage manager would need to understand the current status of a refueling outage. The dashboard presents the critical path, bulk work performance, key performance indicators, outage milestones and metrics relating current performance to historical performance. Additionally, the dashboard includes data analysis tools to allow outage managers to drill down into the underlying data to understand the drivers of the indicators. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Test based reliability assessment method for a safety critical software in reactor protection system - 284

Digitalization of the instrumentation and control systems in nuclear power plant entails some new features which do not exist in analog systems. When the new features are applied in safety critical systems, the risk stemming from them should be quantified properly to assure the reliability of the entire power plant. Among the new features, software is considered as the most important factor because it can cause common cause failure to many redundant systems. Therefore, in this work, a test based reliability assessment method for a safety-critical software is developed. An output of a software is determined by not only inputs but also the internal state of the software at the time. In the case of safety critical software developed for usage in nuclear power plant, it is possible to directly investigate probable internal states thanks to detailed design specification and programing features, and the probable inputs also can be identified based on the physical linearity of each process parameter and hardware characteristics related to data acquisition. In this work, a development method for practical exhaustive test case consisting of investigation of internal state and probable input sets to a specific internal state are suggested. In addition to this, software logic simulator for execution of software logic test and the reliability quantification method based on the test result are developed. The feasibility of the suggested method is demonstrated via a case study. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving nuclear power plant safety and operating margins through linear quadratic estimation - 290

Redundant measurement, trip, and actuation channels are required for reactor trips and engineered safety systems in nuclear power plants. There are three or four independent channels in existing plants, depending on the system. To prevent failures, consistent signals from any two channels together can trip the reactor or actuate safety systems. Measurements associated with safety trips and actuations include uncertainties related to the instruments making the measurements and to process conditions. Margins that include measurement uncertainties are set for each trip and actuation channel as though it were the only one taking action, thus preserving independence. There are sensors, however, that provide partially redundant information that could be used to decrease the uncertainty associated with measurements of plant conditions, while maintaining the three-channel redundancy important to plant safety. Reducing these uncertainties would both improve plant safety by providing more accurate knowledge of plant conditions and improve the operating margins that must take such uncertainties into account. This paper demonstrates how information that is already available to plant instrumentation and control systems and is already redundant can be used through software routines to reduce the error that must be taken into account in reactor trip and safety system actuation setpoints. Issues that would have to be addressed related to standards, licensing, and implementation are also discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Risk informed cyber security for nuclear power plants - 342

Nuclear power plants are increasingly adding digital components for plant operation, safety, and security. These digital components fill a gap with legacy equipment where replacement components no longer exist. They also benefit operation of the plant by increasing efficiency in power generation, monitoring of equipment and plant parameters, as well as aiding operator control. However, the addition of digital components and systems also adds cyber risks with previously unanalyzed failure modes and attack vectors are introduced with these new systems. These risks are difficult to identify, analyze, and mitigate due to the increasingly complex nature of the digital components and the integration of these components with additional plant processes and communication networks. The research presented in this paper develops a new method that addresses the cyber risk to inform appropriate levels of protection. EPRI and Sandia are working under a Cooperative Research and Development Agreement to develop an effective method of evaluating the cyber risk in production nuclear power facilities. The Cyber Hazards Analysis Risk Methodology (CHARM) focuses on ensuring adequate controls are in place for appropriate cyber protection of the plant from radiological release or generation risk. Existing plant hazards analyses (e.g., PRA, FTA) do not account for software deficiencies or adversarial intent. This method leverages existing plant analyses and MIT's Systems Theoretic Process Analysis (STPA) to create cyber informed fault trees. These new fault trees will provide the basis for comprehensive cyber risk analysis and help ensure potential gaps in cyber security controls are identified and corrected. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and application of FPGA-based logic controller - 357

The control systems of nuclear power plants contain many components which are becoming obsolete at an increasing rate. Nowadays maintenance for analog-based protection systems may be difficult as analog parts become obsolete or hard to obtain. Various studies have been conducted to address this control system hardware obsolescence issue. Those control systems of nuclear power plants have been replaced with modern digital control systems such as the programmable logic controller (PLC) and the distributed control system (DCS). The central processing unit (CPU)- based platforms such as the PLC and the DCS require an operating system (OS) and application software, and thus they might result in a common-cause failure when a problem occurs in the operating system or application software. The field programmable gate array (FPGA) is highlighted as an alternative to the conventional protection or control systems. This paper presents the development of an FPGA-based logic controller (FLC) and a diverse protection system (DPS) with the FLC platform. Protection functions for the DPS were implemented in FPGAs without any CPU or OS. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving plant efficiency through the installation of TecSOLCEP online monitoring system - 362

In February 2016, Nuclear Energy Institute (NEI) launched its 'Delivering the Nuclear Promise (DNP)' strategic plan with the objective of reducing electric generating costs by 30% across the nuclear power industry by 2018. Improving efficiency has been addressed as one of the strategic focus areas in the plan. In nuclear power plants (NPPs) there is room for improvement in main components efficiency and TecSOLCEP is a software tool that has proved its value for that purpose. TecSOLCEP is a software tool for monitoring, diagnosing and quantifying performance deviations in Power Plants. It faithfully follows the methodology of ASME standards. Over 15 years of success stories in more than 50 electric power plants of different technologies worldwide, justify the benefits for the plants. The implicit concept in TecSOLCEP is 'Benefit based Maintenance' (BbM) as complementary to usual maintenance strategies like time-based, condition-based or predictive. These maintenance strategies are oriented to obtain the Safety and Reliability goals shared by all the electricity generation technologies. BbM is oriented to get the maximum economic benefit by Efficiency care, which historically has not been a priority, especially in nuclear plants. BbM applied with the help of performance monitoring tools like TecSOLCEP, is called to play an important role to improve efficiency which, in plants mainly operating at full power, is equivalent to increase the maximum power. Nuclear power plants that intend to extend their lives may also take advantage of identifying and quantifying inefficiencies in equipment to better address necessary investments. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fault propagation and effects analysis for designing an online monitoring system for the secondary loop of a nuclear power plant part of a hybrid energy system - 393

This paper studies the propagation and effects of faults of critical components that pertain to the secondary loop of a nuclear power plant found in Nuclear Hybrid Energy Systems (NHES). This information is used to design an on-line monitoring (OLM) system which is capable of detecting and forecasting faults that are likely to occur during NHES operation. In this research, the causes, features, and effects of possible faults are investigated by simulating the propagation of faults in the secondary loop. The simulation is accomplished by using the Integrated System Failure Analysis (ISFA). ISFA is used for analyzing hardware and software faults during the conceptual design phase. In this paper, the models of system components required by ISFA are initially constructed. Then, the fault propagation analysis is implemented, which is conducted under the bounds set by acceptance criteria derived from the design of an OLM system. The result of the fault simulation is utilized to build a database for fault detection and diagnosis, provide preventive measures, and propose an optimization plan for the OLM system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study on Safety Evaluation of Safety Grade Smart Transmitter in Nuclear Power Plants

Smart transmitters contain microprocessors and the use of firmware and software in these microprocessors presents challenges to the nuclear industry, particularly when they are used in safety systems. Non-safety grade smart transmitters have been used for I and C systems of Nuclear Power Plants (NPPs). Recently, smart transmitters have been used for safety grade I and C systems as well as non-safety grade I and C system for SKN 3 and 4 NPPs in Korea. Due to potential benefits of smart transmitter, it is anticipated smart transmitters will be widely used safety-related applications in NPPs. But there is currently no specific nuclear sector standard specifying the criteria for smart transmitter. Therefore, Smart transmitter's technology and characteristics need to be investigated and also develop review guideline of smart transmitter. For this reason, we performed a study on safety evaluation of safety grade Smart Transmitter in NPPs. This paper presents the results of study on safety evaluation of smart transmitter. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Introduction of Diverse Manual Actuation Design for APR1400

APR1400 is an Advanced Light Water Reactor (ALWR) design with enhanced plant safety and advanced design features. One unit is in commercial operation and 11 are currently under construction, 4 abroad and 7 in Korea. APR1400 adopts full digitalized Man-Machine Interface System (MMIS) to perform the function of control, indication and alarming for safety and non-safety systems APR1400 MMIS is designed to operate the plant from the Main Control Room (MCR) under all anticipated operating conditions including design basis accidents. This advanced MMIS is designed to meet the latest codes, standards and regulatory requirements including the defense-in-depth and diversity requirements, which is intended to mitigate the consequence of a total failure of the digital safety system caused by a software Common Cause Failure (CCF) coupled with anyone of the Design Basis Events. The redundancy of the safety system could be defeated during this CCF condition and the protective function could be rendered inoperable.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Developing a GUM Compliant Uncertainty Approach for NDA Gamma Analysis Using FRAM

The Fixed-Energy Response-Function Analysis with Multiple Efficiency (FRAM) code was developed at Los Alamos National Laboratory (LANL) to analyze gamma-ray spectra for the isotopic composition of plutonium or uranium. This software provides means to easily process gamma-ray spectra to obtain isotopic information and is used globally for international safeguards applications. In a recent review of the FRAM code for the use in nuclear forensics applications, it was determined that a more complete understanding and definition of the various sources of uncertainty that contribute to the overall uncertainty of the FRAM measurement process is required. As one of the ISO 17025 accredited Bulk Special Nuclear Materials Analysis Program (BSAP) laboratories, LANL is required to perform an accurate and transparent uncertainty calculation on every analysis it performs. This paper describes a new approach to calculate a Guide to the Expression of Uncertainty in Measurement (GUM) compliant FRAM uncertainty to support nuclear forensics applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Qualification of the First ICS-3000 ION Chromatograph for use at the Defense Waste Processing Facility

The ICS-3000 Ion Chromatography (IC) system installed in 221-S M-13 has been qualified for use. The qualification was a head to head comparison of the ICS-3000 with the currently used DX-500 IC system. The crosscheck work included standards for instrument calibration and calibration verifications and standards for individual anion analysis, where the standards were traceable back to the National Institute of Standards and Technology (NIST). In addition the crosscheck work included the analysis of simulated Sludge Receipt Adjustment Tank (SRAT) Receipt, SRAT Product, and Slurry Mix Evaporator (SME) samples, along with radioactive Sludge Batch 5 material from the SRAT and SME tanks. Based upon the successful qualification of the ICS-3000 in M-13, it is recommended that this task proceed in developing the data to qualify, by a head to head comparison of the two ICS-3000 instruments, a second ICS-3000 to be installed in M-14. The Defense Waste Processing Facility (DWPF) requires the analysis of specific anions at various stages of its processing of high level waste (HLW). The anions of interest to the DWPF are fluoride, formate, chloride, nitrite, nitrate, sulfate, oxalate, and phosphate. The anion analysis is used to evaluate process chemistry including formic acid/nitric acid additions to establish optimum conditions for mercury stripping, reduction-oxidation (REDOX) chemistry for the melter, nitrite destruction, organic acid constituents, etc. The DWPF Laboratory (Lab) has been using Dionex DX-500 ion chromatography (IC) systems since 1998. The vendor informed DWPF in 2006 that the instruments would no longer be supported by service contracts after 2008. DWPF purchased three new ICS-3000 systems in September of 2006. The ICS-3000 instruments are (a) designed to be more stable using an eluent generator to make eluent, (b) require virtually no daily chemical handling by the analysts, (c) require less line breaks in the hood, and (d) generally require less maintenance due to the pump configuration only using water versus the current system where the pump uses various hydroxide concentrations. The ICS-3000 instruments also allow the DWPF to maintain current service contracts, which support routine preventive maintenance and emergency support for larger problems such as component failure. One of the three new systems was set up in the DWPF Lab trailers in January of 2007 to be used for the development of methods and procedures. This system will continue to be used for training, new method development and potential improvements to current methods. The qualification of the other two ICS-3000 instruments is to be a phased effort. This effort is to be supported by the Applied Computational Engineering and Statistical (ACES) group of the Savannah River National Laboratory (SRNL) as authorized by the Technical Task Request (TTR) and as directed by the corresponding Task Technical and Quality Assurance (TT&QA) plan. The installation of the first 'rad' system into the M-13 Lab module required modifications to both the Lab module and to the radiohood. The installation was completed in July 2008. The testing of this system was conducted as directed by the TT&QA plan. The purpose of this technical report is to provide a review of the data generated by these tests that will lead to the recommendation for the qualification of the M-13 ICS-3000 instrument. With the successful qualification of this first ICS-3000, plans will be developed for the installation of the second 'rad' system in the M-14 Lab module later in fiscal year 2009. When the second 'rad' ICS-3000 system is installed, the DX-500 systems will be removed and retired from service.

47 OTHER INSTRUMENTATION↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Route-Optimized Energy Management of Connected and Automated Multi-Mode Plug-In Hybrid Electric Vehicle Using Dynamic Programming

This paper presents a methodology to optimize the blending of charge-depleting (CD) and charge-sustaining (CS) modes in a multi-mode plug-in hybrid electric vehicle (PHEV) that reduces overall energy consumption when the selected route cannot be completely driven in all-electric mode. The PHEV used in this investigation is the second-generation Chevrolet Volt and as many as four instrumented vehicles were utilized simultaneously on road to acquire validation data. The optimization method used is dynamic programming (DP) paired with a reduced-order powertrain model to enable onboard embedded controller compatibility and computational efficiency in optimally blending CD, CS modes over the entire drive route. The objective of the optimizer is to enable future Connected and Automated Vehicles (CAVs) to best utilize onboard energy for minimum overall energy consumption based on speed and elevation profile information from Intelligent Transportation Systems (ITS), Internet of Things (IoT), High-definition Mapping, and onboard sensing technologies. Emphasis is placed on runtime minimization to quickly react and plan an optimal mode scheme in highly dynamic road conditions with minimal computational resources. On-road performance of the optimizer paired with automated CD and CS mode selection is evaluated on a fleet of four instrumented Chevrolet Volts in a variety of driving scenarios. Here, the results indicate variable energy savings depending on the drive route and initial battery SOC with potential ranging between 2 to 12% and less than 7 seconds initial optimization for a 24-mile drive cycle.

33 ADVANCED PROPULSION SYSTEMS↗