Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Ares I-X Ground Diagnostic Prototype

Automating prelaunch diagnostics for launch vehicles offers three potential benefits. First, it potentially improves safety by detecting faults that might otherwise have been missed so that they can be corrected before launch. Second, it potentially reduces launch delays by more quickly diagnosing the cause of anomalies that occur during prelaunch processing. Reducing launch delays will be critical to the success of NASA's planned future missions that require in-orbit rendezvous. Third, it potentially reduces costs by reducing both launch delays and the number of people needed to monitor the prelaunch process. NASA is currently developing the Ares I launch vehicle to bring the Orion capsule and its crew of four astronauts to low-earth orbit on their way to the moon. Ares I-X will be the first unmanned test flight of Ares I. It is scheduled to launch on October 27, 2009. The Ares I-X Ground Diagnostic Prototype is a prototype ground diagnostic system that will provide anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage thrust vector control (TVC) and for the associated ground hydraulics while it is in the Vehicle Assembly Building (VAB) at John F. Kennedy Space Center (KSC) and on the launch pad. It will serve as a prototype for a future operational ground diagnostic system for Ares I. The prototype combines three existing diagnostic tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool that is commercially produced by Qualtech Systems, Inc. It uses a qualitative model of failure propagation to perform fault isolation and diagnostics. We adapted an existing TEAMS model of the TVC to use for diagnostics and developed a TEAMS model of the ground hydraulics. The second tool, Spacecraft Health Inference Engine (SHINE), is a rule-based expert system developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification. The prototype uses the outputs of SHINE as inputs to TEAMS. The third tool, the Inductive Monitoring System (IMS), is an anomaly detection tool developed at NASA Ames Research Center and is currently used to monitor the International Space Station Control Moment Gyroscopes. IMS automatically "learns" a model of historical nominal data in the form of a set of clusters and signals an alarm when new data fails to match this model. IMS offers the potential to detect faults that have not been modeled. The three tools have been integrated and deployed to Hangar AE at KSC where they interface with live data from the Ares I-X vehicle and from the ground hydraulics. The outputs of the tools are displayed on a console in Hangar AE, one of the locations from which the Ares I-X launch will be monitored. The full paper will describe how the prototype performed before the launch. It will include an analysis of the prototype's accuracy, including false-positive rates, false-negative rates, and receiver operating characteristics (ROC) curves. It will also include a description of the prototype's computational requirements, including CPU usage, main memory usage, and disk usage. If the prototype detects any faults during the prelaunch period then the paper will include a description of those faults. Similarly, if the prototype has any false alarms then the paper will describe them and will attempt to explain their causes.

Schwabacher, Mark↗

MCM-41 support for ultrasmall γ-Fe 2 O 3 nanoparticles for H 2 S removal

In this paper, MCM-41 is proposed to build mesostructured Fe 2 O 3 -based sorbents as an alternative to other silica or alumina supports for mid-temperature H 2 S removal. MCM-41 was synthesized as micrometric (MCM41_M) and nanometric (MCM41_N) particles and impregnated through an efficient two-solvent (hexane–water) procedure to obtain the corresponding γ-Fe 2 O 3 @MCM-41 composites. The active phase is homogeneously dispersed within the 2 nm channels in the form of ultrasmall maghemite nanoparticles assuring a high active phase reactivity. The final micrometric (Fe_MCM41_M) and nanometric (Fe_MCM41_N) composites were tested as sorbents for hydrogen sulphide removal at 300 °C and the results were compared with a reference sorbent (commercial unsupported ZnO) and an analogous silica-based sorbent (Fe_SBA15). MCM-41 based sorbents, having the highest surface areas, showed superior performances that were retained after the first sulphidation cycle. Specifically, the micrometric sorbent (Fe_MCM41_M) showed a higher SRC value than the nanometric one (Fe_MCM41_N), due to the low stability of the nanosized particles over time caused by their high reactivity. Finally and furthermore, the low regeneration temperature (300–350 °C), besides the high removal capacity, renders MCM41-based systems an alternative class of regenerable sorbents for thermally efficient cleaning up processes in Integrated Gasification Combined Cycles (IGCC) systems.

36 MATERIALS SCIENCE↗

Capabilities Development: From International Space Station and the Moon to Mars

The President of the United States, in signing Space Policy Directive-1, directed the NASA Administrator “to lead an innovative and sustainable program of exploration with commercial and international partners to enable human expansion across the solar system and to bring back to Earth new knowledge and opportunities. Beginning with missions beyond low-Earth orbit (LEO), the United States will lead the return of humans to the Moon for long-term exploration and utilization, followed by human missions to Mars and other destinations.” NASA is charged to land American astronauts on the lunar South Pole in 2024 and to continue a campaign of sustainable lunar surface exploration in order to develop necessary technologies and capabilities to enable initial human missions to Mars. NASA’s lunar surface exploration plans are part of a continuum of activities utilizing platforms in low Earth orbit (LEO), cislunar space, and the lunar surface to demonstrate advanced technologies, advance operations concepts, and develop countermeasures to lessen the impacts of the space environment and long duration exposure on the crew working in space. NASA is using a capability-driven approach to identify critical gaps to be addressed as part of a focused program to reduce risk for future deep space exploration missions building to eventual human missions to the surface of Mars. Teams of discipline experts from across NASA identify capability gaps between the current state of the art and the needs of proposed exploration missions and develop integrated strategies and roadmaps for filling those gaps. These inputs include assessment of platform needs for demonstration and testing of new capabilities. Generally, the International Space Station (ISS) and Gateway are needed for demonstration of capabilities for Mars transit, while Lunar surface activities focus on development of capabilities and operational protocols for Mars surface. This paper discusses the activities required to advance critical exploration capabilities, focusing on selection of demonstration and test location based upon the unique environments and characteristics of the ISS, Gateway, and potential lunar surface assets. The optimal strategy will be a combination of ISS/LEO, Gateway, and lunar surface testing; however, not all capabilities require a deep space exploration missions.

Boggs, Kathleen Gallagher↗

High Temperature Anode Recycle Blower for Solid Oxide Fuel Cell, Phase II (Final Report)

Broad commercialization of solid oxide fuel cells (SOFCs) requires anode offgas recycle blowers (ARCB) that are specifically designed for handling the challenging operating conditions presented by the SOFC process gases. Otherwise, they can be susceptible to frequent maintenance, low reliability, and short life. This report presents details of a DOE-funded Phase II effort conducted by Mohawk Innovative Technology, Inc. (MiTi®) for the development and testing of an oil-free, low cost, high-temperature centrifugal ARCB based on compliant foil bearing (CFB) technology for support of a 100 kW solid oxide fuel cell power plant. This Phase II builds on the results of a successful Phase I development project that resulted in the demonstration of a low TRL-6 prototype, shown in Figure 1. This Phase II final report presents design improvements over the Phase I prototype, presents the assembled test ARCBs, and discusses the advantages of this novel technology, particularly its long life and maintenance-free operation, which are derived from the use of CFBs. Also included are preliminary techno-economic analysis considerations for cost-effective deployment of the technology. The specific objectives of this project, as stated in the statement of program objectives (SOPO) were 1) to follow the methodology of design for manufacturing (or manufacturability) and assembly for implementing improvements identified as part of the Phase I effort with the purpose of reducing cost, enabling mass production, and facilitating the commercialization of a revised ARCB design, and 2) to fabricate four complete ARCB units based on the revised design and demonstrating their performance in both a laboratory setting and in an actual SOFC power plant. Execution of this SOPO would be supported by a number of technical tasks resulting in the fabrication and testing of the prototypes. To this end, MiTi continued the teaming relationship started during Phase I of the program with subcontracting partner FuelCell Energy, Inc. (FCE), which integrated (under a parallel effort funded by DOE Award DE-FE0026199) a modular 200 kWe SOFC power plant. MiTi and FCE coordinated to ultimately incorporate one of MiTi’s ARCB prototypes into one of the 100 kWe SOFC Modular Power Blocks (MPB) that constitute the core of FCE’s SOFC power plant for in-situ long-duration testing. Additionally, MiTi would explore the scalability and extendibility of the technology to other applications, as well as conduct a basic techno-economic analysis.

03 NATURAL GAS↗

Long Term Processing Using Integrated Hydropyrolysis plus Hydroconversion (IH 2 ) for the Production of Gasoline and Diesel from Biomass

Cellulosic and woody biomass can be directly converted to hydrocarbon gasoline and diesel blending components through the use of a new, economical, technology named integrated hydropyrolysis plus hydroconversion (IH 2 ). The IH 2 gasoline and diesel blending components are fully compatible with petroleum based gasoline and diesel, contain less than 1% oxygen and have less than 1 total acid number (TAN). The IH 2 gasoline is high quality and very close to a drop in fuel. The life cycle analysis (LCA) shows that the use of the IH 2 process to convert wood to gasoline and diesel results in a greater than 90% reduction in greenhouse gas emission compared to that found with fossil derived fuels. The technoeconomic analysis showed the conversion of wood using the IH 2 process can produce gasoline and diesel at less than $\$$2.00/gallon. In this project, the previously reported semi-continuous small scale IH 2 test results were confirmed in a continuous 50 kg/day pilot plant. The continuous IH 2 pilot plant used in this project was operated round the clock for over 750 hours and showed good pilot plant operability while consistently producing 26-28 wt % yields of high quality gasoline and diesel product. The IH 2 catalyst showed good stability, although more work on catalyst stability is recommended. Additional work is needed to commercialize the IH 2 technology including running large particle size biomass, modeling the hydropyrolysis step, studying the effects of process variables and building and operating a 1-50 ton/day demonstration scale plant. The IH 2 is a true game changing technology by utilizing U.S. domestic renewable biomass resources to create transportation fuels, sufficient in quantity and quality to substantially reduce our reliance on foreign crude oil. Thus, the IH 2 technology offers a path to genuine energy independence for the U. S., along with the creation of a significant number of new U.S. jobs to plant, grow, harvest, and process biomass crops into fungible fuels.

09 BIOMASS FUELS↗

The Logical Extension

The same software controlling autonomous and crew-assisted operations for the International Space Station (ISS) is enabling commercial enterprises to integrate and automate manual operations, also known as decision logic, in real time across complex and disparate networked applications, databases, servers, and other devices, all with quantifiable business benefits. Auspice Corporation, of Framingham, Massachusetts, developed the Auspice TLX (The Logical Extension) software platform to effectively mimic the human decision-making process. Auspice TLX automates operations across extended enterprise systems, where any given infrastructure can include thousands of computers, servers, switches, and modems that are connected, and therefore, dependent upon each other. The concept behind the Auspice software spawned from a computer program originally developed in 1981 by Cambridge, Massachusetts-based Draper Laboratory for simulating tasks performed by astronauts aboard the Space Shuttle. At the time, the Space Shuttle Program was dependent upon paper-based procedures for its manned space missions, which typically averaged 2 weeks in duration. As the Shuttle Program progressed, NASA began increasing the length of manned missions in preparation for a more permanent space habitat. Acknowledging the need to relinquish paper-based procedures in favor of an electronic processing format to properly monitor and manage the complexities of these longer missions, NASA realized that Draper's task simulation software could be applied to its vision of year-round space occupancy. In 1992, Draper was awarded a NASA contract to build User Interface Language software to enable autonomous operations of a multitude of functions on Space Station Freedom (the station was redesigned in 1993 and converted into the international venture known today as the ISS)

Source record↗

Integrated Computational-Experimental Development of Lithium-Air Batteries for Electric Aircraft

The primary obstacle to enable NASA's vision of Green Aviation is the extraordinary energy storage requirements for electric aircraft. Significant advances in high energy, rechargeable, safe batteries are required to enable electric aviation. Boeing's SUGAR and NASA studies have identified 400 Wh/kg as the threshold energy density for general aviation and 750 Wh/kg for commercial regional air service. State of the Art Lithium Ion Battery (LIB) technology currently has a density of 200 Wh/kg and is expected to plateau at 300 Wh/kg due to fundamental chemistry limitations making it unsuitable for future electric aircraft. Additional demanding requirements include high power, rechargeability, and high safety. Such battery technology does not currently exist. The recent considerable activity in battery research (DOE, Tesla Gigafactory, etc) overwhelmingly has been geared towards reducing cost and improving safety of LIB technology in order to promote the adoption of electric automobiles; and thus it is expected to have little impact on electric aviation development. New battery materials will be needed for the "Beyond Li Ion" (BLI) technologies required for high energy, safe electric aviation. Li-Air batteries have the highest known theoretical energy density (3400 Wh/kg) and therefore and if realized promises to transform the global transportation system. These high energy batteries have the potential to meet the energy storage challenges of current and future NASA aeronautics and space missions in addition to many terrestrial transportation applications as well. However, this technology requires significant components development and integration, as it is currently unable to achieve aircraft requirements. The objective of this project is to leverage modern computational materials methods combined with battery multiphysics tools to develop radically advanced compatible cathode and electrolyte materials, build several Li-Air cells, and flight-demonstrate the corresponding Li-Air battery packs. A significant problem for current Lithium-Air batteries is large scale decomposition of the battery electrolyte during operation leading to battery failure after a handful of charge/discharge cycles. Therefore, development of large scale, ultra-high energy, rechargeable, and safe Lithium-Air batteries require highly stable electrolytes that are resistant to decomposition under operating conditions. A NASA-based cross-organizational "dream team" of high-powered experts combined integrated supercomputer modeling, fundamental chemistry analysis, advanced material science, and battery cell development to tackle this very challenging, multidisciplinary problem. The ultimate goal for the team is to develop an integrated experimental/computational infrastructure to produce a reliable predictive capability for the selection of optimal components, their fabrication parameters, and "design rules" of novel cell components for advanced ultra-high energy batteries that can meet energy storage challenges of NASA missions and many terrestrial transportation applications.

Li-air battery↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

Achieving a Net Zero Energy Retrofit - In a humid, temperate climate: Lessons from the University of Hawai'i at Manoa

The University of Hawaii at Manoa (UHM) partnered with the US Department of Energy (DOE) to develop and implement solutions to retrofit exiting buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program.1 Kuykendall Hall, located on the UHM campus in Honolulu, was the focus of a CBP analysis and design collaboration among the University of Hawai’i, their consultants, and Lawrence Berkeley National Laboratory (LBNL). Kuykendall Hall consists of two 1960s-era wings – a four-story wing containing classrooms, and a seven-story tower containing offices – with a total floor area of approximately 76,000 square feet (ft2). The retrofit design, which uses local prevailing winds to aid ventilation and cooling and incorporates envelope and lighting elements that reduce the need for cooling, was initially on track to use about 50% less energy than the current building, exceeding the CBP’s 30% savings goal. With the addition of building-mounted solar electric panels, the retrofitted building is projected to achieve net-zero annual energy use. Achieving net-zero energy addressed an emerging challenge to the university – how to lower energy usage and reduce dependence on imported fossil fuel in the face of already-high energy prices that are forecast to double by 2040. Not only will the retrofit dramatically reduce Kuykendall Hall’s annual energy costs, but the project lays the groundwork for new campus policies and processes and low-energy design approaches and is building a campus knowledge base on low-energy practices. This project is a model of integrated design and building delivery that will be replicated in future projects on the campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mapping Impervious Surfaces Globally at 30m Resolution Using Global Land Survey Data

Impervious surfaces, mainly artificial structures and roads, cover less than 1% of the world's land surface (1.3% over USA). Regardless of the relatively small coverage, impervious surfaces have a significant impact on the environment. They are the main source of the urban heat island effect, and affect not only the energy balance, but also hydrology and carbon cycling, and both land and aquatic ecosystem services. In the last several decades, the pace of converting natural land surface to impervious surfaces has increased. Quantitatively monitoring the growth of impervious surface expansion and associated urbanization has become a priority topic across both the physical and social sciences. The recent availability of consistent, global scale data sets at 30m resolution such as the Global Land Survey from the Landsat satellites provides an unprecedented opportunity to map global impervious cover and urbanization at this resolution for the first time, with unprecedented detail and accuracy. Moreover, the spatial resolution of Landsat is absolutely essential to accurately resolve urban targets such a buildings, roads and parking lots. With long term GLS data now available for the 1975, 1990, 2000, 2005 and 2010 time periods, the land cover/use changes due to urbanization can now be quantified at this spatial scale as well. In the Global Land Survey - Imperviousness Mapping Project (GLS-IMP), we are producing the first global 30 m spatial resolution impervious cover data set. We have processed the GLS 2010 data set to surface reflectance (8500+ TM and ETM+ scenes) and are using a supervised classification method using a regression tree to produce continental scale impervious cover data sets. A very large set of accurate training samples is the key to the supervised classifications and is being derived through the interpretation of high spatial resolution (approx. 2 m or less) commercial satellite data (Quickbird and Worldview2) available to us through the unclassified archive of the National Geospatial Intelligence Agency (NGA). For each continental area several million training pixels are derived by analysts using image segmentation algorithms and tools and then aggregated to the 30m resolution of Landsat. Here we will discuss the production/testing of this massive data set for Europe, North and South America and Africa, including assessments of the 2010 surface reflectance data. This type of analysis is only possible because of the availability of long term 30m data sets from GLS and shows much promise for integration of Landsat 8 data in the future.

global land survey↗

Disruption of the Snf1 Gene Enhances Cell Growth and Reduces the Metabolic Burden in Cellulase-Expressing and Lipid-Accumulating Yarrowia lipolytica

Yarrowia lipolytica is known to be capable of metabolizing glucose and accumulating lipids intracellularly; however, it lacks the cellulolytic enzymes needed to break down cellulosic biomass directly. To develop Y. lipolytica as a consolidated bioprocessing (CBP) microorganism, we previously expressed the heterologous CBH I, CBH II, and EG II cellulase enzymes both individually and collectively in this microorganism. We concluded that the coexpression of these cellulases resulted in a metabolic drain on the host cells leading to reduced cell growth and lipid accumulation. The current study aims to build a new cellulase coexpressing platform to overcome these hinderances by (1) knocking out the sucrose non-fermenting 1 ( Snf1 ) gene that represses the energetically expensive lipid and protein biosynthesis processes, and (2) knocking in the cellulase cassette fused with the recyclable selection marker URA3 gene in the background of a lipid-accumulating Y. lipolytica strain overexpressing ATP citrate lyase ( ACL ) and diacylglycerol acyltransferase 1 ( DGA1 ) genes. We have achieved a homologous recombination insertion rate of 58% for integrating the cellulases- URA3 construct at the disrupted Snf1 site in the genome of host cells. Importantly, we observed that the disruption of the Snf1 gene promoted cell growth and lipid accumulation and lowered the cellular saturated fatty acid level and the saturated to unsaturated fatty acid ratio significantly in the transformant YL163t that coexpresses cellulases. The result suggests a lower endoplasmic reticulum stress in YL163t, in comparison with its parent strain Po1g ACL-DGA1. Furthermore, transformant YL163t increased in vitro cellulolytic activity by 30%, whereas the “total in vivo newly formed FAME (fatty acid methyl esters)” increased by 16% in comparison with a random integrative cellulase-expressing Y. lipolytica mutant in the same YNB-Avicel medium. The Snf1 disruption platform demonstrated in this study provides a potent tool for the further development of Y. lipolytica as a robust host for the expression of cellulases and other commercially important proteins.

09 BIOMASS FUELS↗

High-Efficiency Solid State Heat Pump Module

The baseline heat pumping technology today is dominated by vapor compression refrigeration cycle that involves use of global warming potential fluids (e.g. hydrofluorocarbons HFC). Current regulations (e.g. 2016 Kigali agreement) and market needs are driving HVAC&R related building, automotive and aerospace industries to safe, compact and cost-effective systems with low global warming potential (GWP) footprint (i.e. direct GWP impact) and higher efficiencies (i.e. indirect GWP impact) and low life cycle cost. Among the solid-state technology options, electrocaloric heat pumping (ECHP) technology has potential to be more efficient, quiet and compact than vapor compression systems. However, electrocaloric technology is still at low maturity, as expressed by standard technology readiness level (TRL) assessments and hence was the focus of the current effort. During the current research effort, UTRC proved feasibility (TRL2/3) of the direct-air ECHP concept by demonstrating cooling of ambient air by 8.4°C (under no load conditions) in a laboratory environment. To the team’s knowledge this is the largest direct air cooling demonstration using electrocaloric technology. The technology was matured from lab-scale dime-sized materials to module-scale dimensions and further demonstrated the feasibility of integrating these electrocaloric materials into modules for providing direct-air cooling. The use of inexpensive polymer-based materials validates the economic feasibility of the proposed technology. Future effort is required to further mature this promising technology to TRL 4/5 demonstrating module and system performance at full capacity and efficiency. Maturity to beyond TRL4/5 could be done with limited potential field trials. Successful field trials can pave the way for commercialization. At full commercialization, electrocaloric based heating and cooling technologies have the potential to enable annual energy savings upwards of a quadrillion BTUs and reduction of 10s of million metric tons/yr of Green-House Gas (GHG) emissions in the US, leapfrogging emerging technologies and disrupting traditional cooling and heating systems in residential and commercial HVAC applications and enabling new applications. This would result in reduction of energy imports, greenhouse gas (GHG) emissions and help create US jobs in this new technical area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Gold Mine? Achieving HVAC Energy Efficiency Through a System Metric

Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.

Liu, Bing↗

IEA Wind Task 49: Reference Site Conditions for Floating Wind Arrays

The commercial-scale deployment of floating offshore wind (FOW) projects is expected to take place in a diverse range of sites that may differ significantly from existing fixed-bottom projects. FOW farms are particularly sensitive to the water depth and the meteorological and oceanographic (metocean) and geotechnical conditions at the project site due to the wave-induced system motions and loads as well as the anchoring system constraints imposed by the seafloor conditions. Uncertainty around the site conditions will permeate through all aspects of project design, leading to suboptimal and overly conservative designs, increased costs, and adversely affected performance. As FOW expands into a global industry, metocean and geotechnical conditions will increasingly vary for projects located in different geographic regions or in far-from-shore, deep-water sites. This study represents the outputs of work package 1 of International Energy Agency Wind Task 49, which focuses on the integrated design of floating wind arrays. The primary goal of this study is to establish the type of parameters and constraints required to characterize FOW array reference sites; provide a realistic and publicly available set of reference site conditions to the FOW community as a baseline set of data for individual research projects; identify and categorize any critical gaps in the existing data or methodologies required to define reference site characteristics; and inform and support the design of reference FOW arrays. A building block concept was developed for synthesizing reference sites for the design of FOW arrays. The building blocks include three classes of site conditions focusing on the techno-economic design of FOW projects: metocean conditions, seabed conditions, and coastal infrastructure. All reference site data produced and collected in this study are publicly available.

17 WIND ENERGY↗

Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus

This report documents the completion of the DOE study DE-EE0008103: Earth Source Heat: A Cascaded Systems Approach to DDU of Geothermal Energy on the Cornell Campus. This study involved a comprehensive evaluation of the potential for Earth Source Heat (ESH), Cornell’s specific application of Deep Direct Use (DDU) geothermal energy, to create a viable renewable source of thermal energy for its Ithaca, NY campus district heating system. The study included stochastic modeling that married each of two potential subsurface resources (two specific geological reservoirs) to documented campus heating operations based on hourly campus heating profiles and proposed integrated equipment controls (variable speed pumps and heat pumps). The outputs of the subsurface modeling were used as inputs for a Cornell-developed surface heat use Excel-based modeling program (the program was named “Modeled ENergy Use”, or “MEnU”). This allowed Cornell to compute realistic annual totals of extractable and useable heat for the campus, including details like heat losses, minimum summer demand, and controllable building temperature settings. The Cornell team then evaluated the costs and benefits of each modeled scenario. The primary evaluation was a standard “single bottom line” economic calculation for the Levelized Cost of Heat (LCOH). This represents the annualized cost (per unit heat) for Cornell. Additional valuations were also computed based on the benefit to the environment and to the regional economy (i.e., economic benefits external to campus). The results of this study demonstrate that if suitable reservoir flow can be attained, Earth Source Heat would be a viable technology to supply Cornell’s district heating system. This viability is based on the following criteria: (1) The modeled system produced a total useable heat output that exceeded the minimum annual campus heat load determined at the onset of the project (i.e., offsetting at least 20% of the annual campus thermal load). The output range is substantial depending on both the subsurface resource and the surface applications; at the high end, our modeled solutions produced up to ~70% of existing campus heat load with a single well pair producing 70 kg/s with integrated high-temperature heat pumps, and (2) Modeling demonstrated that multiple geothermal reservoirs could provide economically viable results when heat pumps were strategically integrated, a design that has been proven in at least one European installation already. In this context, “economically viable” means that the LCOH for the project is less than the regional commercial price of heat that would be generated using natural gas (the most common and cheapest fossil alternative in our area). Based on a single-bottom-line (LCOH) valuation, our results show that economic success is likely for any reservoir deeper than about 2.25 km where a sufficient permeability exists (or can be created with stimulation or similar engineering enhancement) and reasonable production temperatures sustained over time. The LCOH values of $\$ 4.77$ to $\$ 6.46$ per MMBtu are all lower than the comparable cost of providing heat energy with a natural gas boiler for a facility in the Northeast U.S. that obtains natural gas at commercial rates (Commercial heat costs would include at least $\$ 9.41$ in fuel costs, representing total boiler/transfer efficiency of 85% using gas at $\$ 8.00$ per MMBtu; LCOH would be higher if capital equipment and other operating costs were included). In addition to LCOH, Cornell’s scope also included evaluation of the Environmental value and Regional Economic value of each scenario. When considering the environmental and regional economic value of such a project, the overall “triple bottom line” cost (i.e., the LCOH less the LCOH ENV and LCOH REG values) is even lower and in some cases negative; i.e., in some cases a project achieving the listed performance would have higher value to the environment and to the regional economy than the total project costs over the 30-year project timeframe.

15 GEOTHERMAL ENERGY↗