Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Capacity Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Building a Solar Powered Home in a Historic Neighborhood. A Case Study with CVF Homes, the City of San Antonio Office of Historic Preservation and the Lavaca Neighborhood Association

A Texas collaboration is working to streamline and enable an increase in photovoltaic capacity. The City of San Antonio has made tremendous progress in recent years in the area of solar energy installations on residences. These projects have been great successes, though not without the usual challenges associated with solar energy installations. The City has also seen an increased interest in solar energy systems in official “historic” neighborhoods. These installations have a potential for added challenges, as neighborhoods designated “historic” have additional restrictions, aside from standard building codes, about what changes and upgrades can be done to the exterior. This is in an effort to maintain the historic qualities of the homes and preserve the historical nature of the neighborhoods in which they are present. The purpose of this case study was to examine the construction of a new, single family home, with an included solar energy system, in an official historic neighborhood in San Antonio. Build San Antonio Green hoped to uncover what specific additional challenges the builder faced when working in a historic neighborhood and how those challenges were overcome, to serve as a model for other builders wishing to install solar energy systems in historic neighborhoods. This is of particular importance, as the City of San Antonio has more than 20 officially designated historic neighborhoods, and without proper knowledge of how to comply with the additional regulations, contractors, builders, and solar installers could potentially miss out on tremendous opportunities.

14 SOLAR ENERGY↗

An innovative carbonated cementitious material and its printability and carbon mineralization capacity

The main goal of this research is to develop a carbonated cementitious material (CCMs) mix design and demonstrate its rapid stiffening for manufacturing 3D printed or precast elements for building construction (i.e., concrete with enhanced durability and CO 2 capture efficiency). The material development employs hydrated Ca(OH) 2 , and its distinct reaction with CO 2 to form CaCO 3 . Different formulations and additives including polymer materials enable the thermomechanical properties that give these CCMs 3D printability comparable with cement materials used for similar applications. Here, printable and castable CCM formulations were successfully developed and demonstrated to mineralize CO 2 to form up to 57% CaCO 3 .

36 MATERIALS SCIENCE↗

Development of A High Performance Cold Climate Heat Pump

The primary goals of the proposed project were to develop, test, and evaluate a high performance and cost-effective vapor compression air-source heat pump for use in cold climate regions. Vapor compression heat pumps are a proven technology, and have been used for many years to meet heating requirements for buildings in residential, commercial, and industrial applications. However, in climate regions that experience very low outdoor ambient temperatures both the heating capacity and coefficient of performance (COP) of traditional air-source vapor compression heat pumps drops dramatically with a decrease in the outdoor air temperature. The efficiency of heat pumping equipment has improved substantially over the past 20 years; however, the efficiencies of the highest rated equipment on the market are approaching practical limits that cannot be surpassed without modifications to the basic cycle and possibly the use of additional hardware. In this report, three technologies to improve the efficiency of vapor compression systems are described. These are a) vapor injected compression, b) oil flooded compression and c) hybrid flow control of the evaporator. Compressor prototypes for both, oil flooded and vapor injected compression were developed by Emerson Climate Technologies. For the oil flooded compressor, the oil injection port location was optimized and an internal oil separator was added using several design iterations. After initial testing at Emerson Climate Technologies, further testing was done at Purdue University, and compressor models were developed. These models were then integrated into a system model to determine the achievable improvement of seasonal energy efficiency (SEER) for Minneapolis (Minnesota) climate. For the oil flooded compression, a 34% improvement in seasonal energy efficiency was found while a 21% improvement in seasonal energy efficiency ratio was found for the vapor injected compression. It was found that one benefit of both tested compression technologies is a lower discharge temperature, which allows for continued operation at lower ambient temperatures. A bin analysis of the vapor injected prototype cold climate heat pump predicts a 6% improvement in HSPF for Minneapolis. This improvement is mainly a result of the increased capacity of the system for active vapor injection. For the oil flooded system, a slightly larger performance improvement is predicted, in this case mostly caused by an increase in heating COP. Based on an economic analysis of these results, the maximum additional cost of the system changes, for the Minneapolis location, are $\$430$ for the vapor injected system and $\$391$ for the oil flooded system. These estimates assume that a 3-year simple payback period is accepted by the customer. For the hybrid flow control of evaporators, a new type of balancing valve was developed together with Emerson Climate technologies to reduce the cost of the control scheme. In contrast to conventional stepper motor valves, this valve requires less cables and can be driven by a cheaper output circuit on the control board. The correct valve size was determined in a dedicated test stand in several design iterations. The performance benefits of the hybrid control of the evaporator coil were determined for clean coil conditions as well as with partial blockage of the air inlet grille and under frosting conditions. For clean coil conditions, the benefits in terms of COP and capacity are negligible. However, significant benefits were noted for severely air-maldistributed operating conditions. For the H2-test, the maximum COP improvement of 17% along with a capacity improvement of nearly 40% was observed. Overall, the hybrid control scheme leads to a significant amount of performance improvement, if the air inlet conditions to the evaporator are maldistributed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Abengoa/Acciona Power Plant Hydrogen Mitigation Project (Cooperative Research and Development Final Report, CRADA Number CRD-15-583)

Several Gigawatts (GW) of solar concentrating parabolic trough generating capacity have been installed in the U.S. and internationally in the past five years. Many of these power plants include thermal energy storage, which allows the plants to generate electricity during off-sun hours. The U.S. now has about 1 GW of solar-to-electric generating capacity using concentrating parabolic trough technology. Parabolic trough power plants have a long-standing performance issue relating to the build-up of trace quantities of hydrogen gas in the receiver tubes. Hydrogen is a byproduct of the very slow breakdown of the heat transfer fluid. Accumulation of hydrogen in the receivers causes a loss in the thermal efficiency of the receivers and an overall decrease in the power plant annual electricity output. Since a typical plant contains 50,000 receivers, addressing this issue by individual receiver is not practical. The National Renewable Energy Laboratory (NREL) conceived and developed a method to remove or purge hydrogen from the power plant receivers by removing hydrogen from a single location within the plant. Hydrogen gas is purged from the heat transfer fluid that resides in the power plant expansion tanks. Modeling shows that quantitative removal of hydrogen from the expansion tanks will reverse build-up of hydrogen in the receiver tubes and restore the power plant to its full performance and annual energy output. This method is documented in U.S. Patent 8,568,582, which issued in October 2013. Two companies, Abengoa Solar and Acciona Solar Power, Inc. contacted NREL to discuss solutions to the eventual build-up of hydrogen in their commercial parabolic trough power plants. NREL proposed to implement its method at Acciona's Nevada Solar One (NSO) parabolic trough power plant in Boulder City, Nevada. The first year will consist of laboratory testing at the NREL Energy Systems Integration Facility (ESIF) along with process specification, design, and costing. The second year will be the full-scale implementation of the hydrogen mitigation process at the NSO power plant in Nevada.

14 SOLAR ENERGY↗

Frequency Analysis of Solar PV Power to Enable Optimal Building Load Control

In this paper, we present a flexibility estimation mechanism for buildings’ thermostatically controlled loads (TCLs) to enable the distribution level consumption of the majority of solar photovoltaic (PV) generation by local building TCLs. The local consumption of PV generation provides several advantages to the grid operation as well as the consumers, such as reducing the stress on the distribution network, minimizing voltage fluctuations and two-way power flows in the distribution network, and reducing the required battery storage capacity for PV integration. This would result in increasing the solar PV generation penetration levels. The aims of this study are twofold. First, spectral (frequency) analyses of solar PV power generation together with the power consumption of multiple building TCLs (such as heating, ventilation, and air conditioning (HVAC) systems, water heaters, and refrigerators) are performed. These analyses define the bandwidth over which these TCLs can operate and also describe the PV generation frequency bandwidth. Such spectral analyses, in frequency domain, can help identify the flexible components of PV generation that can be consumed by the various TCLs through optimal building load utilization. Second, a quadratic optimization problem based on model predictive control is formulated to allow consuming most of the low and medium frequency content of the PV power locally by building TCLs, while maintaining occupants’ comfort and TCLs’ physical constraints. The solution to the proposed optimization problem is achieved using optimal control strategies. Numerical results show that most of the low and medium frequency content of the PV generation can be consumed locally by building TCLs. The remaining high-frequency content of the PV generation can then be stored/offset using energy storage systems.

14 SOLAR ENERGY↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Using Dimmable Lighting for Regulation Capacity and Non-Spinning Reserves in the Ancillary Services Market. A Feasibility Study.

The objective of this Feasibility Study was to identify the potential of dimmable lighting for providing regulation capacity and contingency reserves if massively-deployed throughout the State. We found that one half of the total electric lighting load in the California commercial sector is bottled up in larger buildings that are greater an 50,000 square feet. Retrofitting large California buildings with dimmable lighting to enable fast DR lighting would require an investment of about $1.8 billion and a"fleet" of about 56 million dimming ballasts. By upgrading the existing installed base of lighting and controls (primarily in large commercial facilities) a substantial amount of ancillary services could be provided. Though not widely deployed, today's state-of-the art lighting systems, control systems and communication networks could be used for this application. The same lighting control equipment that is appropriate for fast DR is also appropriate for achieving energy efficiency with lighting on a daily basis. Thus fast DR can leverage the capabilities that are provided by a conventional dimming lighting control system. If dimmable lighting were massively deployed throughout large California buildings (because mandated by law, for example) dimmable lighting could realistically supply 380 MW of non-spinning reserve, 47percent of the total non-spinning reserves needed in 2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Stationary Lithium-Ion Batteries for Optimization and Predictive Control

Accurately modeling stationary battery storage behavior is crucial to understand and predict its limitations in demand-side management scenarios. In this paper, a lithium-ion battery model was derived to estimate lifetime and state-of-charge for building-integrated use cases. The proposed battery model aims to balance speed and accuracy when modeling battery behavior for real-time predictive control and optimization. In order to achieve these goals, a mixed modeling approach was taken, which incorporates regression fits to experimental data and an equivalent circuit to model battery behavior. A comparison of the proposed battery model output to actual data from the manufacturer validates the modeling approach taken in the paper. Additionally, a dynamic test case demonstrates the effects of using regression models to represent internal resistance and capacity fading.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

User Guide for the International Jobs and Economic Development Impacts Model

The International Jobs and Economic Development Impacts (I-JEDI) model is a freely available economic model that estimates gross economic impacts from wind, solar, and geothermal energy projects for several different countries. Building on the original JEDI model, which was developed for the United States, I-JEDI was developed under the USAID Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) program to support countries in assessing economic impacts of LEDS actions in the energy sector. I-JEDI estimates economic impacts by characterizing the construction and operation of energy projects in terms of expenditures and the portion of these expenditures made within the country of analysis. These data are then used in a country-specific input-output (I-O) model to estimate employment, earnings, gross domestic product (GDP), and gross output impacts. Total economic impacts are presented as well as impacts by industry. This user guide presents general information about how to use I-JEDI and interpret results as well as detailed information about methodology and model limitations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guia del Usuario para el Modelo Internacional de Impacto en Trabajos y Desarrollo Economico

This is a Spanish translation of 'User Guide for the International Jobs and Economic Development Impacts Model.' The International Jobs and Economic Development Impacts (I-JEDI) model is a freely available economic model that estimates gross economic impacts from wind, solar, and geothermal energy projects for several different countries. Building on the original JEDI model, which was developed for the United States, I-JEDI was developed under the USAID Enhancing Capacity for Low Emission Development Strategies (EC-LEDS) program to support countries in assessing economic impacts of LEDS actions in the energy sector. I-JEDI estimates economic impacts by characterizing the construction and operation of energy projects in terms of expenditures and the portion of these expenditures made within the country of analysis. These data are then used in a country-specific input-output (I-O) model to estimate employment, earnings, gross domestic product (GDP), and gross output impacts. Total economic impacts are presented as well as impacts by industry. This user guide presents general information about how to use I-JEDI and interpret results as well as detailed information about methodology and model limitations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Oglala Omaste 2020

Oglala Lakota Housing Authority (OLHA), the tribally designated housing entity of the Oglala Sioux Tribe, installed solar photovoltaic (PV) systems on six tribal buildings, including the Oglala Lakota Housing Authority administration building, four Veterans Affairs Supportive Housing (HUD-VASH) homes, and one Rural Innovation Fund (RIF) home. Combined, the total solar PV capacity of this project is approximately 54 kilowatts-direct current (kW-DC), offsetting an estimated 74,176 kilowatt-hours (kWh) per year and saving OLHA and tenants of the tribally owned residences approximately $\$$8,226 annually. The lifetime savings of the project is estimated to be $\$$380,344. The project aligns with energy goals of OLHA and the Oglala Sioux Tribe to reduce energy costs for low rent tenants and to reduce our carbon footprint; both of which are in line with Lakota values.

14 SOLAR ENERGY↗

Nuclear Fuel Traces Definition in Storage Ponds of Research VVR-2 and OR Reactors in NRC 'Kurchatov Institute'

The Gas Plant complex is the experimental base of the Institute of Nuclear Reactors, which is part of the Kurchatov Institute. In 1954 the commissioning of the first Soviet water-cooled water-moderated research reactor VVR-2 on enriched uranium, and until 1983 the complex operated two research water-cooled water-moderated reactors 3 MW (VVR-2) and 300 kW (OR) capacity, which were dismantled in connection with the overall upgrades of the complex. The complex has three storage ponds in the reactor building. They are sub-surface vessels filled with water (the volume of water in each is about 6 m{sup 3}). In 2007-2013 the spent nuclear fuel from storages was removed for processing to 'Mayk'. Survey of Storage Ponds by Underwater Collimated Spectrometric System shows a considerable layer of slime on the bottom of ponds and traces of spent nuclear fuel in one of the storage. For determination qualitative and the quantitative composition of radionuclide we made complex α-, β-, γ- spectrometric research of water and bottom slimes from Gas Plant complex storage ponds. We found the spent nuclear fuel in water and bottom slime in all storage ponds. Specific activity of radionuclides in the bottom slime exceeded specific activity of radionuclides in the ponds water and was closed to levels of high radioactive waste. Analysis of the obtained data and data from earlier investigation of reactor MR storage ponds showed distinctions of specific activity of uranium and plutonium radionuclides. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Fuel Traces Definition in Storage Ponds of Research VVR-2 and OR Reactors in NRC 'Kurchatov Institute' - 16022

The Gas Plant complex is the experimental base of the Institute of Nuclear Reactors, which is part of the Kurchatov Institute. In 1954 the commissioning of the first Soviet water-cooled water-moderated research reactor VVR-2 on enriched uranium, and until 1983 the complex operated two research water-cooled water-moderated reactors 3 MW (VVR-2) and 300 kW (OR) capacity, which were dismantled in connection with the overall upgrades of the complex. The complex has three storage ponds in the reactor building. They are sub-surface vessels filled with water (the volume of water in each is about 6 m{sup 3}). In 2007-2013 the spent nuclear fuel from storages was removed for processing to 'Mayak'. Survey of Storage Ponds by Underwater Collimated Spectrometric System shows a considerable layer of slime on the bottom of ponds and traces of spent nuclear fuel in one of the storage pond. For determination qualitative and the quantitative composition of radionuclide we made complex α-, β-, γ - spectrometric research of water and bottom slimes from Gas Plant complex storage ponds. We found the spent nuclear fuel in water and bottom slime in all storage ponds. Specific activity of radionuclides in the bottom slime exceeded specific activity of radionuclides in the ponds water and was closed to levels of high radioactive waste. Analysis of the obtained data and data from earlier investigation of reactor MR storage ponds showed distinctions of specific activity of uranium and plutonium radionuclides. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LCLS Ultrafast Science Instruments II (LUSI-II) Proposal

We propose to build a suite of science instruments that will allow users to take full advantage of LCLS-II, an expansion of the existing Linac Coherent Light Source that is expected to produce first light in 2018. LCLS-II will add two undulator sources for producing x-ray laser beams, tripling the capacity of the current facility. The instrument construction project proposed here, LCLS Ultrafast Science Instruments II (LUSI-II), will greatly enhance the capabilities of LCLS and keep it at the forefront of an intensifying international race to build and operate x-ray free-electron laser (XFEL) facilities. The proposed instruments have been identified in collaboration with the scientific community and are in alignment with the DOE mission of managing world-leading basic research programs and stewarding unique user facilities.

XFEL↗

Recycled tetrahedron-like CuCl from waste Cu scraps for lithium ion battery anode

Highlights: • High EVA CuCl was recycled with 88.7% recovery from waste Cu craps. • The recycled CuCl displayed regular tetrahedron-like morphology. • The evolution mechanism of the recycled CuCl crystal was proposed. • The corresponding discharge capacity in LIB was 171.8 mAh/g after 50 cycles. • The results shed a new light on resource recovery and environmental protection. - Abstract: The wide applications of metal Cu inevitably resulted in a large quantity of waste Cu materials. In order to recover the useful Cu under the mild conditions and reduce the environmental emission, waste Cu scraps were recycled in the form of CuCl powders with high economic value added (EVA) via the facile hydrothermal route. The recycled CuCl powders were characterized in terms of scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). The results suggested that the recycled CuCl powders consisted of many regular tetrahedron-like micro-particles. Furthermore, in order to reduce the cost of lithium ion battery (LIB) anode and build the connection of waste Cu scraps and LIB, the recycled CuCl powders were evaluated as the anode active material of LIB. As expected, the reversible discharge capacity was about 171.8 mAh/g at 2.0 C even after 50 cycles, implying the satisfactory cycle stability. Clearly, the satisfactory results may open a new avenue to develop the circular economy and the sustainable energy industry, which would be very important in terms of both the resource recovery and the environmental protection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring engineered cementitious composites for impact resistance

This paper presents results of deliberate tailoring of engineered cementitious composites (ECC) for impact resistance. Microstructure control involving fiber, matrix and fiber/matrix interface was based on steady-state dynamic crack growth analyses accounting for rate dependence of composite phases. Uniaxial tensile stress-strain curves of the resulting impact resistant ECC were experimentally determined for strain rates ranging from 10{sup -5} s{sup -1} to 10{sup -1} s{sup -1}. Low speed drop weight tower test on ECC panels and beams was also conducted. Damage characteristics, load and energy dissipation capacities, and response to repeated impacts, were studied.

36 MATERIALS SCIENCE↗

The Influence of a CO2 Pricing Scheme on Distributed Energy Resources in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial-sector distributed energy resources (DER) with combined heat and power (CHP) in greenhouse gas emissions (GHG) reductions. Historically, relatively little attention has been paid to the potential of medium-sized commercial buildings with peak electric loads ranging from 100 kW to 5 MW. In our research, we examine how these medium-sized commercial buildings might implement DER and CHP. The buildings are able to adopt and operate various technologies, e.g., photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, batteries and thermal storage systems. We apply the Distributed Energy Resources Customer Adoption Model (DER-CAM), which is a mixed-integer linear program (MILP) that minimizes a site?s annual energy costs and/or CO2 emissions. Using 138 representative mid-sized commercial sites in California, existing tariffs of major utilities, and expected performance data of available technologies in 2020, we find the GHG reduction potential for these buildings. We compare different policy instruments, e.g., a CO2 pricing scheme or a feed-in tariff (FiT), and show their contributions to the California Air Resources Board (CARB) goals of additional 4 GW CHP capacities and 6.7 Mt/a GHG reduction in California by 2020. By applying different price levels for CO2, we find that there is competition between fuel cells and PV/solar thermal. It is found that the PV/solar thermal adoption increases rapidly, but shows a saturation at high CO2 prices, partly due to limited space for PV and solar thermal. Additionally, we find that large office buildings are good hosts for CHP in general. However, most interesting is the fact that fossil-based CHP adoption also increases with increasing CO2 prices. We will show service territory specific results since the attractiveness of DER varies widely by climate zone and service territory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Distributed Intelligent Automated Demand Response Building Management System

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗