Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

The low cycle fatigue behavior of a plasma-sprayed coating material

Single crystal nickel-base superalloys employed in turbine blade applications are often used with a plasma spray coating for oxidation and hot corrosion resistance. These coatings may also affect fatigue life of the superalloy substrate. As part of a large program to understand the fatigue behavior of coated single crystals, fully reversed, total strain controlled fatigue tests were run on a free standing NiCoCrAlY coating alloy, PWA 276, at 0.1 Hz. Fatigue tests were conducted at 650 C, where the NiCoCrAlY alloy has modest ductility, and at 1050 C, where it is extremely ductile, showing tensile elongation in excess of 100 percent. At the lower test temperature, deformation induced disordering softened the NiCoCrAlY alloy, while at the higher test temperature cyclic hardening was observed which was linked to gradual coarsening of the two phase microstructure. Fatigue life of the NiCoCrAlY alloy was significantly longer at the higher temperature. Further, the life of the NiCoCrAlY alloy exceeds that of coated, /001/-oriented PWA 1480 single crystals at 1050 C, but at 650 C the life of the coated crystal is greater than that of the NiCoCrAlY alloy on a total strain basis.

Gayda, J.↗

Low cycle fatigue behaviour of a plasma-sprayed coating material

Single crystal nickel-base superalloys employed in turbine blade applications are often used with a plasma spray coating for oxidation and hot corrosion resistance. These coatings may also affect fatigue life of the superalloy substrate. As part of a large program to understand the fatigue behavior of coated single crystals, fully reversed, total strain controlled fatigue tests were run on a free standing NiCoCrAlY coating alloy, PWA 276, at 0.1 Hz. Fatigue tests were conducted at 650 C, where the NiCoCrAlY alloy has modest ductility, and at 1050 C, where it is extremely ductile, showing tensile elongation in excess of 100 percent. At the lower test temperature, deformation induced disordering softened the NiCoCrAlY alloy, while at the higher test temperature cyclic hardening was observed which was linked to gradual coarsening of the two phase microstructure. Fatigue life of the NiCoCrAlY alloy was significantly longer at the higher temperature. Further, the life of the NiCoCrAlY alloy exceeds that of coated, /001/-oriented PWA 1480 single crystals at 1050 C but at 650 C the life of the coated crystal is greater than that of the NiCoCrAlY alloy on a total strain basis.

Gayda, J.↗

Biofilm formation and control in a simulated spacecraft water system - Three year results

Two simulated spacecraft water systems are being used to evaluate the effectiveness of iodine for controlling microbial contamination within such systems. An iodine concentration of about 2.0 mg/L is maintained in one system by passing ultrapure water through an iodinated ion exchange resin. Stainless steel coupons with electropolished and mechanically-polished sides are being used to monitor biofilm formation. Results after three years of operation show a single episode of significant bacterial growth in the iodinated system when the iodine level dropped to 1.9 mg/L. This growth was apparently controlled by replacing the iodinated ion exchange resin, thereby increasing the iodine level. The second batch of resin has remained effective in controlling microbial growth down to an iodine level of 1.0 mg/L. SEM indicates that the iodine has impeded but may have not completely eliminated the formation of biofilm. Metals analyses reveal some corrosion in the iodinated system after 3 years of continuous exposure. Significant microbial contamination has been present continuously in a parallel noniodinated system since the third week of operation.

Schultz, John R.↗

Optical Thin Films for Gas Sensing in Advanced Coal Fired Power Plants

Even for existing coal based plants, the opportunity for sensors and controls to improve efficiency is great. A wide range of gas species are of interest for relevant applications. Functional sensor layers for embedded sensing must be compatible with extreme conditions (temperature, pressure, corrosive). Au incorporated metal oxides have been looked at by a number of other authors previously for gas sensing, but have often focused on temperatures below 500{degree}C. Au nanoparticle incorporated metal oxide thin films have shown enhanced gas sensing response. In prior work, we have demonstrated that material systems such as Au nanoparticle incorporated TiO{sub 2} films exhibit a potentially useful optical response to changing gas atmospheres at temperatures up to ~800-850{degree}C. Current work is focused on sputter-deposited Au/TiO{sub 2} films. Au and Ti are multi-layered sputter deposited, followed by a 950{degree}C oxidation step. Increasing Au layer thickness yields larger particles. Interband electronic transitions significantly modify the optical constants of Au as compared to the damped free electron theory. A high temperature oxidation (20%O{sub 2}/N{sub 2}) treatment was performed at 700{degree}C followed by a reduction (4%H{sub 2}/N{sub 2}) treatment to illustrate the shift in both absorption and scattering with exposure to reducing gases. Shift of localized surface plasmon resonance (LSPR) absorption peak in changing gas atmospheres is well documented, but shift in the peak associated with diffuse scattering is a new observation. Increasing Au layer-thickness results in an increase in LSPR absorption and a shift to longer wavelengths. Diffuse scattering associated with the LSPR resonance of Au shows a similar trend with increasing Au thickness. To model the temperature dependence of LSPR, the modification to the plasmon frequency, the damping frequency, and the dielectric constant of the oxide matrix must be accounted for. Thermal expansion of Au causes a decrease in free-carrier concentration and plasmon frequency with increasing temperature. Increased scattering of electrons with increasing temperatures results in an increased damping frequency for free carriers. The thermo-optic coefficient of TiO{sub 2} is assumed to be constant or decreasing with increasing temperature. A Custom Designed System Can Be Used to Monitor Optical Transmission and Reflection of Films at Elevated Temperatures and Upon Exposure to Changing Ambient Gas Atmospheres. The calculated extinction peak broadens and reduces peak height with increasing temperature. Extinction spectra measured using the elevated temperature system deviate from measurements performed with an integrating sphere. Modifications to measured transmittance and reflectance spectra are observed with increasing temperatures. Optical constants of Au nanoparticles were measured for elevated temperature. The thermo-optic coefficient of TiO{sub 2} strongly affects the shift in LSPR absorption peak. Peak broadening is dictated by the increased damping frequency of Au. In all cases of the theoretical modeling, we are assuming a particle of Au embedded in a TiO{sub 2} matrix without any interparticle interaction. Localized surface plasmon resonance in noble metal nanoparticles is associated with the free electrons. Surface charges create an internal field that acts as a restoring force on displaced charge carriers resulting in an oscillation with an associated resonance. An estimate of the sensitivity as a function of wavelength for sensing done using a single wavelength transmission measurement can be derived by focusing on the partial derivative of Q{sub abs} with respect to the material parameter that we assume is changing during the experiment. We focus on the free carrier density. However, other material parameters may also change in some cases. Peak sensitivity for transmission or absorption based sensing occurs on either side of the LSPR absorption peak maximum. Theoretically predicted wavelength dependence is consistent with the literature. The wavelength of LSPR absorption peak sensitivity shifts with increasing temperature due to broadening and peak shifting. The maximum sensitivity decreases with increasing temperature. The sensitivity should also depend on the mechanism responsible for the solid-gas interaction.

36 MATERIALS SCIENCE↗

Final Report - Inspection Limit Confirmation for Upper Head Penetration Nozzle Cracking

The ASME Code Case N-729-1 defines alternative examination requirements for the Control Rod Drive Mechanism (CRDM) upper head penetration nozzle welds. The basis for these examination requirements was developed as part of an Industry program conducted by the Materials Reliability Program (MRP) through the Electric Power Research Institute (EPRI). The results of this program were published in MRP-95 Rev. 1 and document a set of finite element weld residual stress analyses conducted on a variety of upper head penetration nozzles. The inspection zone selected by the industry was based on the stress where it was assumed that primary water stress corrosion cracking (PWSCC) would not initiate. As explained in MRP-95 Rev. 1, it has been illustrated that PWSCC does not occur in the Alloy 600 tube when the stresses are below the yield strength of that tube. Typical yield strengths at operating conditions for Alloy 600 range from 35 ksi to 65 ksi. A stress less than 20-ksi tension was chosen as a conservative range where PWSCC would not initiate. Over the last several years, Engineering Mechanics Corporation of Columbus (Emc2) has conducted welding residual stress analyses on upper head penetration J-welds made from Alloy 182 weld metal for the U.S. Nuclear Regulatory Commission (NRC) staff. These efforts were performed as a confirmatory evaluation of the industry’s analyses conducted as part of their MRP-95 Rev. 1 effort. To this point, the analyses conducted by Emc2 have not been compared to the MRP-95 Rev. 1 results or the examination zones defined in the Code Case. Therefore, this report summarizes the past Emc2 CRDM welding analyses and investigates the regions where the welding stresses may be sufficiently high to promote stress corrosion cracking (SCC). In all, 90 welding residual stress analyses were conducted by Emc2 and the largest distance below the weld where the stress drops below 20 ksi was 5 inches for the uphill weld of the 53-degree nozzle case. For the largest distance above the weld where stress drops below 20 ksi, the worst case was 1.5 inches above the downhill side of the 25-degree nozzle case. The inspection zones described in both MRP-95 Rev. 1 and Code Case N-729-1 were set at 1.0 inch for nozzle angles greater than 30 degrees or 1.5 inches for nozzle angles less than 30 degrees, above the highest or below the lowest point on the weld. In all cases analyzed by Emc2 in this effort, there was only one case where the stress was above 20 ksi outside of this inspection zone. For that case, the stresses were very close to 20 ksi at the inspection zone limit and were considered acceptable.

36 MATERIALS SCIENCE↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Force reduction of friction stir welding and processing of steel

Friction stir welding and processing (FSW&P) is considered as a new fabrication method for canisters and repair of existing dry cask storage system canisters (generally made of austenitic stainless steel). Low heat input compared to fusion joining processes and grain refinement associated with low-temperature FSW&P result in a material with improved mechanical properties and equivalent generalized corrosion performance relative to the base metal. But FSW&P of austenitic stainless steel requires significant tool forge axis force to produce a weld (or a run). Exploratory runs utilizing forge axis force control were conducted to investigate the minimum force required to achieve defect-free runs. The correlation between forge axis force and resultant plunge depth was also investigated. Furthermore, detailed microstructural characterization was conducted to display the microstructural variation within the nugget zone.

36 MATERIALS SCIENCE↗

Chloride capture using a C–H hydrogen bonding cage

Tight binding and high selectivity are hallmarks of biomolecular recognition. Achieving these behaviors with synthetic receptors has usually been associated with OH and NH hydrogen bonding. Contrary to this conventional wisdom, we designed a chloride-selective receptor in the form of a cryptand-like cage using only CH hydrogen bonding. Crystallography demonstrated chloride stabilized by six short 2.7-Å hydrogen bonds originating from the cage’s six 1,2,3-triazoles. Atto-molar affinity (10 17 M –1 ) was determined using liquid- liquid extractions of chloride from water into nonpolar dichloromethane solvents. Controls verified the additional role of triazoles in rigidifying the 3D structure to effect recognition affinity and selectivity: Cl – > Br – > NO 3 – > I – . This cage reflects anti-Hofmeister salt extraction and preliminary corrosion inhibition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance and Durable Low PGM Cathode Catalysts

There is a strong need to decrease the amount of Pt electrocatalyst used in fuel cells and increase its durability for transportation application. Conventional strategies include Pt nanocrystals and Pt alloy with well-controlled structures, durable carbon support, non-carbon support, etc. We have developed the so-called “metal-metal oxide-carbon” triple junction concept to stabilize Pt and protect carbon from corrosion. It also improved the activity of Pt. The good performance was not achieved in fuel cell test mainly because of the transport issue due to the use of 2D graphene. In this project, our main goal is to demonstrate the concept in fuel cell device test using 3D porous graphene as support so that the transport issue could be addressed.

08 HYDROGEN↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Ultrafine PBI fibers and yarns

Gentle precisely controlled process is used to draw polybenzimidazole (PBI) fibers to denier as low as 0.17 per fiber. Yarns of lightweight fibers could be useful in applications where lightweight textiles must withstand high temperatures, corrosion, or radiation.

Leal, J. R.↗

A system approach to archival storage

The introduction and viewgraphs of a discussion on a system approach to archival storage presented at the National Space Science Data Center (NSSDC) Mass Storage Workshop is included. The use of D-2 iron particles for archival storage is discussed along with how acceleration factors relating short-term tests to archival life times can be justified. Ampex Recording Systems is transferring D-2 video technology to data storage applications, and encountering concerns about corrosion. To protect the D-2 standard, Battelle tests were done on all four tapes in the Class 2 environment. Error rates were measured before and after the test on both exposed and control groups.

Corcoran, John W.↗

Superhard Nanocrystalline Homometallic Stainless Steel on Steel for Seamless Coatings

The objective of this work is to deposit nanocrystalline stainless steel onto steel substrates (homometallic) for enhanced wear and corrosion resistance. Homometallic coatings provide superior adhesion, and it has been shown that ultrafine-grained materials exhibit the increased hardness and decreased permeability desired for protective coatings. Nanocrystals will be produced by controlling nucleation and growth and use of an ion beam during deposition by e-beam evaporation or sputtering. Phase I is depositing 31 6L nanocrystalline stainless steel onto 31 6L stainless steel substrates. These coatings exhibit hardnesses comparable to those normally obtained for ceramic coatings such ZrO2, and possess the superior adhesion of seamless, homometallic coatings. Hardening the surface with a similar material also enhances adhesion, by avoiding problems associated with thermal and lattice mismatch. So far we have deposited nanocrystalline homometallic 316L stainless steel coatings by varying the ions and the current density of the ion beams. For all deposition conditions we have produced smooth, uniform, superhard coatings. All coatings exhibit hardness of at least 200% harder than that of bulk materials. Our measurements indicate that there is a direct relationship between nanohardness and the current density of the ion beam. Stress measurements indicate that stress in the films is increasingly proportional to current density of the ion beam. TEM, XPS, and XRD results indicate that the coated layers consist of FCC structure nanocrystallites with a dimension of about 10 to 20 nm. The Ni and Mo concentration of these coating are lower than those of bulk 316L but the concentration of Cr is higher.

Tobin, Eric J.↗

High-Temperature Multi-Process Sensor Development and Demonstration at a Full-scale PC Combustion System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Hot Corrosion Test Facility at the NASA Lewis Special Projects Laboratory

The Hot Corrosion Test Facility (HCTF) at the NASA Lewis Special Projects Laboratory (SPL) is a high-velocity, pressurized burner rig currently used to evaluate the environmental durability of advanced ceramic materials such as SiC and Si3N4. The HCTF uses laboratory service air which is preheated, mixed with jet fuel, and ignited to simulate the conditions of a gas turbine engine. Air, fuel, and water systems are computer-controlled to maintain test conditions which include maximum air flows of 250 kg/hr (550 lbm/hr), pressures of 100-600 kPa (1-6 atm), and gas temperatures exceeding 1500 C (2732 F). The HCTF provides a relatively inexpensive, yet sophisticated means for researchers to study the high-temperature oxidation of advanced materials, and the injection of a salt solution provides the added capability of conducting hot corrosion studies.

Robinson, Raymond C.↗

Facile Separation of Sr-90, Fe-55, Nb-94, Ni-59,63 with Large Amount of Ca by Controlled pH Precipitation - 17190

it is important to manage low-and intermediate-level radioactive wastes from nuclear power plants due to a permanent disposal. According to the Nuclear Safety and Security Commission (NSSC), among all the regulatory radionuclides, a few radionuclides from the fission products and corrosion products such as Sr-90, Fe-55, Nb-94, Ni-59,63 which emit low-energy x-ray and beta radiation. Thus, it is necessary to separate beta-emitting nuclides individually. For that reason, KAERI has established analytical procedures which can separate Sr-90, Fe-55, Nb-94, Ni-59,63 from radioactive waste samples. However, when radioactive wastes contain large amount of Ca (above 300 mg), it is not easy to recover the target radionuclides because high concentration of Ca has a strong influence on the effective analyses. In order to combat this problem, there was an attempt to make the precipitate as CaF{sub 2} by using hydrofluoric acid. However, this way had a limitation; Fe-55, Nb-94 were precipitated as fluoride compounds as well as Ca. In this study, we have focused on developing a separation procedure stage by stage in the radioactive wastes with Sr-90, Fe-55, Nb-94, Ni-59,63 and large amount of Ca (1500 mg). The detailed steps are described below; (1) Separation of Fe-55, Nb-94, Ni-59,63 as metal hydroxide precipitates: low solubility product constant (Ksp) between pH 6 and pH 10. (2) Selective elimination of Ca-oxalate complex under strong acidic conditions. Consequently, all the metal sources were sequentially separated and quantitatively recovered by inductively coupled plasma atomic emission spectrometric (ICP-AES) analysis, the recovery is as follows; Sr-90 (3 mg): 89.47±5.48%, Fe-55 (20 mg): 99.80±3.19%, Nb-94 (20 mg): 97.45±2.42%, Ni-59,63 (2 mg): 83.59±15.31%, Ca (1500 mg): 85.32±6.38%, respectively. This methodology will help us separation of radioactive wastes efficiently if apply properly. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Interplay Between Plastic Deformations and Optical Properites of Metal Surfaces: A Multiscale Study

The design of metallic surfaces with required surface quality and visual appearance represents a significant challenge for scientists and engineers. For example, the surface of aluminum products such as reflector bright sheet, aerospace structural components, and architectural materials is always required to have an attractive appearance under different lighting conditions and to be free of defects and corrosion [ref. 1]. Industrial-scale modification processes of metal alloy products (heat treatment, rolling, stretching, extruding, etc.) are closely related to different plastic phenomena. Although plastic deformation takes place at the macroscopic level, it significantly changes the surface geometry at the meso- and microscopic scales which may result in spectacular modifications of visual appearance of the deformed surface. Here we use a combination of confocal optical microscopy, orientation imaging microscopy with electron back scattering diffraction (EBSD), original morphological image analysis approach developed by the authors, and finite element simulations, in order to investigate the interplay of different plastic instabilities emerging in the course of plastic deformation, and visual appearance. It is demonstrated that visual brightness of aluminum sheet products could be significantly suppressed by some widely used industrial processes such as uniaxial stretching of the sheet. On the other hand, a properly designed “texture rolling” (i.e., embossing additional controlled engineered features into the metal surface) makes it significantly brighter than a conventionally rolled surface because these features may serve as sinks for otherwise incompatible plastic deformations and enhance brightness due to the suppression of roughness. It is expected that such “imaging transitions” are of general nature and could be observed for different metals and alloys exhibiting plastic instabilities. In turn, these results provide guidelines for the control of metal surface morphology in order to achieve desirable visual appearance, such as visual brightness and omnidirectional coloration.

36 MATERIALS SCIENCE↗