Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPUTING NETWORK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Epidemic Propagation In Overlaid Wireless Networks

Witb tbe emergence of computer worms tbat can spread over air interfaces, wireless ad boc and sensor networks can be vulnerable to node compromises even if the deployed network is not connected to the backbone. Depending on the physical topology of the wireless network, even a single infected node can compromise the whole network. In this work, epidemic (e.g., worm) propagation in a static wireless network is studied, where a number of inCected mobile nodes are injected over the existing network. It is shown that the epidemic spread threshold and size depend on the physical topology of the underlying static wireless network as well as the mobility model employed by the infected mobile nodes. More specifically, results show that in a Cully-connected static wirelessnctwork targeted attacks are more effective, wbereas Cor a random topology random attacks can be sufficient to compromise the whole network.

42 ENGINEERING↗

Computational design of soft materials for the capture of Cs-137 in contaminated environments: From 2D covalent cucurbituril networks to 3D supramolecular materials

Using computational quantum chemistry methods we design novel 2D and 3D soft materials made of cucurbituril macrocycles covalently connected with each other via rigid linkers. Such covalent cucurbituril networks might be useful for the capture of radioactive Cs-137 (present as Cs{sup +}) in the contaminated environment.

54 ENVIRONMENTAL SCIENCES↗

Launching applications on compute and service processors running under different operating systems in scalable network of processor boards with routers

A multiple processor computing apparatus includes a physical interconnect structure that is flexibly configurable to support selective segregation of classified and unclassified users. The physical interconnect structure also permits easy physical scalability of the computing apparatus. The computing apparatus can include an emulator which permits applications from the same job to be launched on processors that use different operating systems.

97 MATHEMATICS AND COMPUTING↗

Portals 4 network API definition and performance measurement

Portals is a low-level network programming interface for distributed memory massively parallel computing systems designed by Sandia, UNM, and Intel. Portals has been designed to provide high message rates and to provide the flexibility to support a variety of higher-level communication paradigms. This project developed and analyzed an implementation of Portals using shared memory in order to measure and understand the impact of using general-purpose compute cores to handle network protocol processing functions. The goal of this study was to evaluate an approach to high-performance networking software design and hardware support that would enable important DOE modeling and simulation applications to perform well and to provide valuable input to Intel so they can make informed decisions about future network software and hardware products that impact DOE applications.

99 GENERAL AND MISCELLANEOUS↗

Prediction of Weld Penetration in FCAW of HSLA steel using Artificial Neural Networks

Flux-cored arc welding (FCAW) is a semiautomatic or automatic arc welding process that requires a continuously-fed consumable tubular electrode containing a flux. The main FCAW process parameters affecting the depth of penetration are welding current, arc voltage, nozzle-to-work distance, torch angle and welding speed. Shallow depth of penetration may contribute to failure of a welded structure since penetration determines the stress-carrying capacity of a welded joint. To avoid such occurrences; the welding process parameters influencing the weld penetration must be properly selected to obtain an acceptable weld penetration and hence a high quality joint. Artificial neural networks (ANN), also called neural networks (NN), are computational models used to express complex non-linear relationships between input and output data. In this paper, artificial neural network (ANN) method is used to predict the effects of welding current, arc voltage, nozzle-to-work distance, torch angle and welding speed on weld penetration depth in gas shielded FCAW of a grade of high strength low alloy steel. 32 experimental runs were carried out using the bead-on-plate welding technique. Weld penetrations were measured and on the basis of these 32 sets of experimental data, a feed-forward back-propagation neural network was created. 28 sets of the experiments were used as the training data and the remaining 4 sets were used for the testing phase of the network. The ANN has one hidden layer with eight neurons and is trained after 840 iterations. The comparison between the experimental results and ANN results showed that the trained network could predict the effects of the FCAW process parameters on weld penetration adequately.

36 MATERIALS SCIENCE↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Knowledge Integration to Make Decisions About Complex Systems: Sustainability of Energy Production from Agriculture

A major bottleneck for improving the governance of complex systems, rely on our ability to integrate different forms of knowledge into a decision support system (DSS). Preliminary aspects are the classification of different types of knowledge (a priori or general, a posteriori or specific, with uncertainty, numerical, textual, algorithmic, complete/incomplete, etc.), the definition of ontologies for knowledge management and the availability of proper tools like continuous simulation models, event driven models, statistical approaches, computational methods (neural networks, evolutionary optimization, rule based systems etc.) and procedure for textual documentation. Following these views at University of Udine, a computer language (SEMoLa, Simple, Easy Modelling Language) for knowledge integration has been developed. SEMoLa can handle models, data, metadata and textual knowledge; it implements and extends the system dynamics ontology (Forrester, 1968; Jørgensen, 1994) in which systems are modelled by the concepts of material, group, state, rate, parameter, internal and external events and driving variables. As an example, a SEMoLa model to improve management and sustainability (economical, energetic, environmental) of the agricultural farms is presented. The model (X-Farm) simulates a farm in which cereal and forage yield, oil seeds, milk, calves and wastes can be sold or reused. X-Farm is composed by integrated modules describing fields (crop and soil), feeds and materials storage, machinery management, manpower management, animal husbandry, economic and energetic balances, seed oil extraction, manure and wastes management, biogas production from animal wastes and biomasses.

03 NATURAL GAS↗

Benchmarking the Performance of Neuromorphic and Spiking Neural Network Simulators

Software simulators play a critical role in the development of new algorithms and system architectures in any field of engineering. Neuromorphic computing, which has shown potential in building brain-inspired energy-efficient hardware, suffers a slow-down in the development cycle due to a lack of flexible and easy-to-use simulators of either neuromorphic hardware itself or of spiking neural networks (SNNs), the type of neural network computation executed on most neuromorphic systems. While there are several openly available neuromorphic or SNN simulation packages developed by a variety of research groups, they have mostly targeted computational neuroscience simulations, and only a few have targeted small-scale machine learning tasks with SNNs. Evaluations or comparisons of these simulators have often targeted computational neuroscience-style workloads. In this work, we seek to evaluate the performance of several publicly available SNN simulators with respect to non-computational neuroscience workloads, in terms of speed, flexibility, and scalability. We evaluate the performance of the NEST, Brian2, Brian2GeNN, BindsNET and Nengo packages under a common front-end neuromorphic framework. Our evaluation tasks include a variety of different network architectures and workload types to mimic the computation common in different algorithms, including feed-forward network inference, genetic algorithms, and reservoir computing. We also study the scalability of each of these simulators when running on different computing hardware, from single core CPU workstations to multi-node supercomputers. Our results show that the BindsNET simulator has the best speed and scalability for most of the SNN workloads (sparse, dense, and layered SNN architectures) on a single core CPU. However, when comparing the simulators leveraging the GPU capabilities, Brian2GeNN outperforms the others for these workloads in terms of scalability. NEST performs the best for small sparse networks and is also the most flexible simulator in terms of reconfiguration capability NEST shows a speedup of at least 2x compared to the other packages when running evolutionary algorithms for SNNs. The multi-node and multi-thread capabilities of NEST show at least 2x speedup compared to the rest of the simulators (single core CPU or GPU based simulators) for large and sparse networks. We conclude our work by providing a set of recommendations on the suitability of employing these simulators for different tasks and scales of operations. We also present the characteristics for a future generic ideal SNN simulator for different neuromorphic computing workloads.

97 MATHEMATICS AND COMPUTING↗

Message communications of particular message types between compute nodes using DMA shadow buffers

Message communications of particular message types between compute nodes using DMA shadow buffers includes: receiving a buffer identifier specifying an application buffer having a message of a particular type for transmission to a target compute node through a network; selecting one of a plurality of shadow buffers for a DMA engine on the compute node for storing the message, each shadow buffer corresponding to a slot of an injection FIFO buffer maintained by the DMA engine; storing the message in the selected shadow buffer; creating a data descriptor for the message stored in the selected shadow buffer; injecting the data descriptor into the slot of the injection FIFO buffer corresponding to the selected shadow buffer; selecting the data descriptor from the injection FIFO buffer; and transmitting the message specified by the selected data descriptor through the data communications network to the target compute node.

Blocksome, Michael A↗

Computer-aided detection using non-convolutional neural network Gaussian processes

Deep convolutional neural networks (CNNs) have in recent years achieved record-breaking performance on many image classification tasks and are therefore well-suited for computer aided detection (CAD). The need for uncertainty quantification for CAD motivates the need for a probabilistic framework for deep learning. The most well-known probabilistic neural network model is the Bayesian neural network (BNN), but BNNs are notoriously difficult to sample for large complex network architectures, and as such their use is restricted to small problems. It is known that the limit of BNNs as their widths increase toward infinity is a Gaussian process (GP), and there has been considerable research interest in these infinitely wide BNNs. Recently, this classic result has been extended to deep architectures in what is termed the neural network Gaussian process (NNGP) model. In this work, we implement an NNGP model and apply it to the ChestXRay14 dataset at the full resolution of 1024x1024 pixels. Even without any convolutional aspects to the network architecture and without any data augmentation, our five layer deep NNGP model outperforms other non-convolutional models and therefore helps to narrow the performance gap between non-convolutional and convolutional models. Our NNGP model is fully Bayesian and therefore offers uncertainty information through its predictive variance that can be used to formulate a predictive confidence measure. We show that the performance of the NNGP model is significantly boosted after low-confidence predictions are rejected, suggesting that convolution is most beneficial only for these low-confidence examples. Finally, our results indicate that an extremely large fully-connected neural network with appropriate regularization could perform as well as the NNGP if not for the computational bottleneck resulting from the large number of model parameters.

Agrawal, Devanshu↗

Switching Device-Cognizant Sequential Distribution System Restoration

This paper presents an optimization framework for sequential reconfiguration using an assortment of switching devices and repair process in distribution system restoration. Compared to existing studies, this paper considers types, capabilities and operational limits of different switching devices, making it applicable in practice. We develop a novel multi-phase method to find the optimal sequential operation of various switching devices and repair faulted areas. We consider circuit breakers, reclosers, sectionalizers, load breaker switches, and fuses. The switching operation problem is decomposed into two mixed-integer linear programming (MILP) subproblems. The first subproblem determines the optimal network topology and estimates the number of steps to reach that topology, while the second subproblem generates a sequence of switching operations to coordinate the switches. For repairing the faults, we design an MILP model that dispatches repair crews to clear faults and replace melted fuses. After clearing a fault, we update the topology of the network by generating a new sequence of switching operations, and the process continues until all faults are cleared. To improve the computational efficiency, a network reduction algorithm is developed to group line sections, such that only switchable sections are present in the reduced network. The proposed method is validated on the IEEE 123-bus and 8500-bus systems.

distribution system↗

PCAfold 2.0—Novel tools and algorithms for low-dimensional manifold assessment and optimization

We describe an update to our open-source Python package, PCAfold, designed to help researchers generate, analyze and improve low-dimensional data manifolds. In the current version, PCAfold 2.0, we introduce novel tools and algorithms for assessing and optimizing low-dimensional manifolds. This includes a method that generates a “map” of local feature sizes that can help pinpoint researchers to problematic regions on a manifold. We introduce a novel cost function that characterizes the quality of a manifold topology with a single number. We develop two algorithms for feature selection based on principal component analysis (PCA) that use the cost function as an objective function to minimize. We introduce a quantity of interest (QoI)-aware dimensionality reduction strategy where data projections are computed using an artificial neural network and are directly optimized towards representing various projection-independent and projection-dependent QoIs. We also introduce an implementation of partition of unity networks (POUnets) for efficient reconstruction of QoIs from low-dimensional manifolds based on combining neural network classification with localized polynomial regression. Our software can be broadly applicable in all domains of science and engineering that aim to reduce data dimensionality, as well as in the fundamental research on representation learning.

97 MATHEMATICS AND COMPUTING↗

Collaborative Computing Support for Analysis Facilities Exploiting Software as Infrastructure Techniques

Prior to the public release of Kubernetes it was difficult to conduct joint development of elaborate analysis facilities due to the highly non-homogeneous nature of hardware and network topology across compute facilities. However, since the advent of systems like Kubernetes and OpenShift, which provide declarative interfaces for building fault-tolerant and self-healing deployments of networked software, it is possible for multiple institutes to collaborate more effectively since resource details are abstracted away through various forms of hardware and software virtualization. In this whitepaper we will outline the development of two analysis facilities: "Coffea-casa" at University of Nebraska Lincoln and the "Elastic Analysis Facility" at Fermilab, and how utilizing platform abstraction has improved the development of common software for each of these facilities, and future development plans made possible by this methodology.

97 MATHEMATICS AND COMPUTING↗

Ion trap with in-vacuum high numerical aperture imaging for a dual-species modular quantum computer

Photonic interconnects between quantum systems will play a central role in both scalable quantum computing and quantum networking. Entanglement of remote qubits via photons has been demonstrated in many platforms; however, improving the rate of entanglement generation will be instrumental for integrating photonic links into modular quantum computers. We present an ion trap system that has the highest reported free-space photon collection efficiency for quantum networking. We use a pair of in-vacuum aspheric lenses, each with a numerical aperture of 0.8, to couple 10(1)% of the 493 nm photons emitted from a 138Ba+ ion into single-mode fibers. We also demonstrate that proximal effects of the lenses on the ion position and motion can be mitigated.

Instruments & Instrumentation↗

Low Loss Graded Index Polymer Optical Fiber for Local Networking

Here, the objective of this Department of Energy SBIR program has been to develop technology for the advancement of advanced computing systems. NanoSonic worked with two subcontractors, the Polymicro Division of Molex, a U.S.-based manufacturer of specialized optical fiber and fiber components, and Virginia Tech, a research university involved through the Global Environment for Network Innovations (GENI) program in high-speed computer networking research. NanoSonic developed a patented molecular-level self-assembly process to manufacture polymer-based optical fibers in a way similar to the modified chemical vapor deposition (MCVD) approach typically used to make glass optical fibers. Although polymer fiber has a higher attenuation per unit length than glass fiber, short connectorized polymer fiber jumpers offer significant cost savings over their glass counterparts, particularly due to the potential use of low-cost plastic fiber connectors. As part of the SBIR commercialization process, NanoSonic exclusively licensed this technology to a large ($100B+ market cap) U.S.-based manufacturing conglomerate near the end of the first year of the Phase II program. With this base technology developed and licensed, NanoSonic then worked with Polymicro to address secondary program goals of using related but not conflicting production methods to enhance the performance of other specialty optical fiber products and components, and Virginia Tech continued its evaluation of developed polymer fibers in its network infrastructure system on the university campus. We also report our current understanding of the observation during the Phase I program of quantum conductance and partial quantum conductance in metal-insulator-metal (MIM) devices. Such conductance behavior may be modeled as singlemode behavior in one-dimensional electrically conducting waveguides, similar in principle to singlemode optical propagation in dielectric fiber waveguides. Although NanoSonic has not licensed any of the additional technology developed during the second year of the program, several proprietary discussions with major materials companies are underway as of the conclusion of Phase II.

36 MATERIALS SCIENCE↗