Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CM process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Dissolution of Light Curium Oxide with a Catalyzed Electrolytic Process

The ability to produce transcurium elements and isotopes, such as 249 Bk and 252 Cf, requires the appropriate feed material and a high thermal neutron flux. Currently, at Oak Ridge National Laboratory (ORNL), the High Flux Isotope Reactor (HFIR) provides one of the world’s highest steady state thermal neutron fluxes. The feed material consists of recycled curium from the decades of production of 249 Bk, 252 Cf, 253 Es, and 255/257 Fm at the Radiochemical Engineering Development Center (REDC). Over time, the feed material has been depleted and needs to be replenished. The current feed material is called “heavy recycled curium” and consists of over 50 wt% of 246/248 Cm isotopes. In order to replenish this stock material, additional curium is needed. The only curium material that is currently available consists predominantly (greater than 80 wt%) of 244 Cm. This material also contains 240 Pu from the radioactive decay of the 244 Cm. Because of the amount of 244 Cm is greater than 50% of the total Cm, this material is termed “light curium.” Today, 249 Bk and 252 Cf are produced in only two places in the world: the United States and Russia. In the United States, the US Department of Energy and its predecessors have made these isotopes and others available to research agencies and commercial users since the late 1960s as part of the Department of Energy heavy-element production program located at ORNL. Currently these materials are provided through the DOE Office of Science Nuclear Physics-Isotope Development and Production for Research and Applications and the Basic Energy Science-Heavy Element Chemistry. Feedstock for the production of 252 Cf and other transcurium element by-product isotopes was originally prepared by means of irradiation of multi-kilograms of 239 Pu in the large production reactors at the Savannah River Site. Products of the Savannah River Site irradiation were predominantly 242 Pu, 243 Am, and 244 Cm. These materials were shipped to ORNL for production of multi-milligram amounts per year of 252 Cf and other transcurium element isotopes by means of irradiation in the HFIR, followed by separation and purification processing in the Radiochemical Engineering Development Center (REDC). The transcurium element isotopes produced were distributed to other US and collaborating foreign laboratories for research studies to determine the nuclear and chemical properties of these rare materials. The Cm feed material plays a key role in the efficient production of 252 Cf. The early targets irradiated in HFIR contained only the 242 Pu, 243 Am, and 244 Cm produced at Savannah River Site, and the rate of production of 252 Cf was less than 1 mg per 8 g of target material as shown in Figure 1. Also, shown in Figure 1 is the significant difference in 252 Cf production between the light and heavy curium; it differs by approximately 2 orders of magnitude.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Daher-TLI UCSC Wash Process - Lessons Learned from Handling a Legacy Cylinder - 16506

The Daher-TLI UF{sub 6} Cylinder Service Center (UCSC) began operation in 2013 and functions as a dedicated wash, re-certification, storage and disposal facility for 122 cm uranium hexafluoride (UF{sub 6}) cylinders. The primary purpose of the facility is to provide cylinder cleaning and re--certification services to the UF{sub 6} industry for cylinders that previously contained natural or depleted UF6. The facility also has the ability to recover most of the uranium in the form of uranyl peroxide (UO{sub 4}) or triuranium octoxide (U{sub 3}O{sub 8}). Small residues of UF{sub 6} (commonly referred to as a heel) from natural cylinders are removed and treated in a patented three-step purification process that recovers U{sub 3}O{sub 8} that meets the ASTM specification. The wastewater ordinarily contains a mixture of sodium salts (77% sodium sulfate, 23% sodium nitrate) along with minute traces of uranium (1 - 2 mg/L) and fluoride (10 - 20 mg/L). Over a period of 6 months, lab analyses were performed on the filtrate from a legacy cylinder in an attempt to separate uranium and fluoride from this stream. These pilot results established near quantitative recovery of uranium (< 1 mg/L) and near complete separation of fluorides (5 - 15 mg/L). This paper follows the efforts of the Daher-TLI UCSC to process the abnormal heeled UF{sub 6} cylinder. This paper also documents the lessons learned from this experience and how those lessons were used to improve the UCSC wash process. These modifications served to recover 99.87% of the input uranium as UO{sub 4} while simultaneously creating a waste stream with only trace amounts of impurities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mark-18A Cold Runs

The Savannah River National Laboratory (SRNL) is tasked by the National Nuclear Security Administration (NNSA) to recover highly valued isotopes from irradiated Mark-18A (Mk-18A) targets. The Savannah River Site (SRS) has sixty-five Mk-18A targets available for the recovery of the high valued materials. The sixty-five Mk-18A targets are currently stored in the L-Area Basin and will be removed one at a time and individually transported to SRNL. Upon receipt at SRNL, the Mk-18A target material will be removed from the confinement, dissolved, chemically separated, and calcined to a stable oxide. The flowsheet is designed to recover the plutonium as well as the trivalent actinides. The remaining unrecovered material will be discarded to the high activity drain (HAD) system in SRNL. A specially designed cask was procured for transport of the targets from L-Area to SRNL. Once received at SRNL, the targets will be loaded into the back of Cell 7 and resized as they enter the cell. The resized targets (1/4 lengths) will then be processed one at a time through the following processes: caustic dissolution and filtration; acidic dissolution and filtration, Reillex anion exchange, diglycolamide (DGA) cation exchange; and DGA calcination. This processing will result in two product streams. The first is an aqueous plutonium solution which will be removed from the shielded cells and taken to a glovebox for further purification and conversion to an oxide. The second is a calcined oxide containing the Am and Cm as well as other lanthanide fission products which will be removed from the shielded cells using a bagless transfer system. Both materials will be packaged for shipment to Oak Ridge National Laboratory (ORNL). All equipment to carry out this process was designed, procured or fabricated, and installed in a mock-up facility (716-4A) at SRS to allow for simulation testing in a non-radioactive area. This equipment was then dismantled and transferred from 716-4A to 773-A and installed in the SRNL Shielded Cells. After installation in the shielded cells facility testing was performed using water followed by surrogates and cold chemicals. Issues were identified during these evaluations, including equipment issues as well as technical challenges. Many of the issues were rectified during performance of the cold runs, and the remaining have a resolution identified. Table ES-1 provides a summary of all issues identified during the cold run operations, as well as the status and identified resolutions to outstanding issues.

07 ISOTOPE AND RADIATION SOURCES↗

Low-temperature processed high-performance flexible perovskite solar cells via rationally optimized solvent washing treatments

High performance planar-heterojunction (PHJ) perovskite (CH3NH3PbI3) solar cells fabricated through lowtemperature annealing are demonstrated. Simple spin-coating with an optimized solvent washing process readily forms homogeneous and crystalline perovskite thin films. The perovskite films fabricated via this solvent washing process show a low dependence on annealing temperature in achieving high crystallinity and large grain size, prerequisites for high efficiency perovskite solar cells. The solar cell device fabricated by solvent washing and 100 C annealing exhibited a high power conversion efficiency (PCE) over 14% with high short circuit current density (JSC) of 19.3 mA cm 2 and fill factor (FF) of 0.80. More importantly, the device annealed at low temperature (<90 C) also yields high PCEs of over 12%. This enables us to fabricate flexible solar cells at low-temperatures with promising PCE as high as 9.43%. This study demonstrates that this optimized solvent washing process is highly relevant for low-cost rollto-roll (R-2-R) processing of high performance perovskite solar cells.

14 SOLAR ENERGY↗

Scalable, low-cost ink-based processing of high-performance silver selenide thermoelectrics

The growing global energy demand and its accelerating contribution to climate change emphasize the urgent need for sustainable energy conversion/harvesting technologies. Thermoelectric (TE) devices offer a compelling route to directly convert waste heat into electricity and enable solid-state cooling without moving parts or harmful refrigerants. Achieving their full potential requires not only higher TE performance (zT) but also scalable, low-cost manufacturing processes. Here, we introduce a transformative ink-based processing approach for scalable manufacturing of high-performance silver selenide-based TE materials and devices. Using a simple, high-throughput ink-mixing and blade coating strategy, our Ag 2 Se-based materials under the optimized composition and processing conditions yield an ultrahigh room-temperature power factor of 2.8 mW m −1 K −2 , over 100% higher than baseline samples and a reproducible figure of merit zT of 1 at room temperature. A thermoelectric generator (TEG) achieves a very competitive power density of 112 mW cm −2 at a 90 °C temperature difference between the hot and cold sides of the device, which is among the highest reported for silver selenide-based TE devices to date. This facile, scalable ink-based processing establishes a practical pathway toward industrial-scale manufacturing and widespread adoption of thermoelectric devices, advancing sustainable energy technologies.

Bappy, Md. Omarsany [University of Notre Dame, IN ↗

Deep learning and radiomics: the utility of Google TensorFlow™ Inception in classifying clear cell renal cell carcinoma and oncocytoma on multiphasic CT

Purpose: Currently, all solid enhancing renal masses without microscopic fat are considered malignant until proven otherwise and there is substantial overlap in the imaging findings of benign and malignant renal masses, particularly between clear cell RCC (ccRCC) and benign oncocytoma (ONC). Radiomics has attracted increased attention for its utility in pre-operative work-up on routine clinical images. Radiomics based approaches have converted medical images into mineable data and identified prognostic imaging signatures that machine learning algorithms can use to construct predictive models by learning the decision boundaries of the underlying data distribution. The TensorFlow™ framework from Google is a state-of-the-art open-source software library that can be used for training deep learning neural networks for performing machine learning tasks. The purpose of this study was to investigate the diagnostic value and feasibility of a deep learning-based renal lesion classifier using open-source Google TensorFlow™ Inception in differentiating ccRCC from ONC on routine four-phase MDCT in patients with pathologically confirmed renal masses. Methods: With institutional review board approval for this 1996 Health Insurance Portability and Accountability Act compliant retrospective study and a waiver of informed consent, we queried our institution’s pathology, clinical, and radiology databases for histologically proven cases of ccRCC and ONC obtained between January 2000 and January 2016 scanned with a an intravenous contrast-enhanced four-phase renal mass protocol (unenhanced (UN), corticomedullary (CM), nephrographic (NP), and excretory (EX) phases). To extract features to be used for the machine learning model, the entire renal mass was contoured in the axial plane in each of the four phases, resulting in a 3D volume of interest (VOI) representative of the entire renal mass. We investigated thirteen different approaches to convert the acquired VOI data into a set of images that adequately represented each tumor which was used to train the final layer of the neural network model. Training was performed over 4000 iterations. In each iteration, 90% of the data were designated as training data and the remaining 10% served as validation data and a leave-one-out cross-validation scheme was implemented. Accuracy, sensitivity, specificity, positive (PPV) and negative predictive (NPV) values, and CIs were calculated for the classification of the thirteen processing modes. Results: We analyzed 179 consecutive patients with 179 lesions (128 ccRCC and 51 ONC). The ccRCC cohort had a mean size of 3.8 cm (range 0.8–14.6 cm) and the ONC cohort had a mean lesion size of 3.9 cm (range 1.0–13.1 cm). The highest specificity and PPV (52.9% and 80.3%, respectively) were achieved in the EX phase when we analyzed the single mid-slice of the tumor in the axial, coronal and sagittal plane, and when we increased the number of mid-slices of the tumor to three, with an accuracy of 75.4%, which also increased the sensitivity to 88.3% and the PPV to 79.6%. Using the entire tumor volume also showed that classification performance was best in the EX phase with an accuracy of 74.4%, a sensitivity of 85.8% and a PPV of 80.1%. When the entire tumor volume, plus mid-slices from all phases and all planes presented as tiled images, were submitted to the final layer of the neural network we achieved a PPV of 82.5%. Conclusions: The best classification result was obtained in the EX phase among the thirteen classification methods tested. Our proof of concept study is the first step towards understanding the utility of machine learning in the differentiation of ccRCC from ONC on routine CT images. We hope this could lead to future investigation into the development of a multivariate machine learning model which may augment our ability to accurately predict renal lesion histology on imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent Fast Wave Coupling and Heating Studies on NSTX, with Possible Implications for ITER

The goal of the high harmonic fast wave (HHFW) research on NSTX is to maximize the coupling of RF power to the core of the plasma by minimizing the coupling of RF power to edge loss processes. HHFW core plasma heating efficiency in helium and deuterium L-mode discharges is found to improve markedly on NSTX when the density 2 cm in front of the antenna is reduced below that for the onset of perpendicular wave propagation (nonset ∝ B*k|| 2/ω). In NSTX, the observed RF power losses in the plasma edge are driven in the vicinity of the antenna as opposed to resulting from multi-pass edge damping. PDI surface losses through ion-electron collisions are estimated to be significant. Recent spectroscopic measurements suggest that additional PDI losses could be caused by the loss of energetic edge ions on direct loss orbits and perhaps result in the observed clamping of the edge rotation. Initial deuterium H-mode heating studies reveal that core heating is degraded at lower kφ (- 8 m-1 relative to 13 m-1) as for the Lmode case at elevated edge density. Fast visible camera images clearly indicate that a major edge loss process is occurring from the plasma scrape off layer (SOL) in the vicinity of the antenna and along the magnetic field lines to the lower outer divertor plate. Large type I ELMs, which are observed at both kφ values, appear after antenna arcs caused by precursor blobs, low level ELMs, or dust. For large ELMs without arcs, the source reflection coefficients rise on a 0.1 ms time scale, which indicates that the time derivative of the reflection coefficient can be used to discriminate between arcs and ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent Fast Wave Coupling and Heating Studies on NSTX, with Possible Implications for ITER

The goal of the high harmonic fast wave (HHFW) research on NSTX is to maximize the coupling of RF power to the core of the plasma by minimizing the coupling of RF power to edge loss processes. HHFW core plasma heating efficiency in helium and deuterium L-mode discharges is found to improve markedly on NSTX when the density 2 cm in front of the antenna is reduced below that for the onset of perpendicular wave propagation (nonset ∝ B*k|| 2/ω). In NSTX, the observed RF power losses in the plasma edge are driven in the vicinity of the antenna as opposed to resulting from multi-pass edge damping. PDI surface losses through ion-electron collisions are estimated to be significant. Recent spectroscopic measurements suggest that additional PDI losses could be caused by the loss of energetic edge ions on direct loss orbits and perhaps result in the observed clamping of the edge rotation. Initial deuterium H-mode heating studies reveal that core heating is degraded at lower kφ (- 8 m-1 relative to 13 m-1) as for the Lmode case at elevated edge density. Fast visible camera images clearly indicate that a major edge loss process is occurring from the plasma scrape off layer (SOL) in the vicinity of the antenna and along the magnetic field lines to the lower outer divertor plate. Large type I ELMs, which are observed at both kφ values, appear after antenna arcs caused by precursor blobs, low level ELMs, or dust. For large ELMs without arcs, the source reflection coefficients rise on a 0.1 ms time scale, which indicates that the time derivative of the reflection coefficient can be used to discriminate between arcs and ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Chemically Inert Hydrocarbon-Based Slurries for Rapid Laser Sintering of Thin Proton-Conducting Ceramics

The process of rapid laser sintering of thin BaZrO 3 –BaCeO 3 -based proton-conducting electrolytes is being developed for easy fabrication of ceramic fuel cells and electrolyzers. However, cracks on the electrolytes caused by volume change due to chemical reactions between the basic ceramic constituents and the polar solvents during wet processing has been problematic. In order to address this issue, the use of chemically inert saturated-hydrocarbon-based slurries comprised of hexadecane, polybutene, and a long-chain saturated fatty acid were investigated in this work. By optimizing slurry composition and laser sintering conditions, a 20 mm long, 4 mm wide, 13.5-μm-thick and 97%-dense BaCe 0.7 Zr 0.1 Y 0.07 Sm 0.13 O 3-d membrane showing proton conductivity on the order of 10 –4 S•cm –1 at 600 °C was successfully prepared in just three seconds by laser sintering. As a result, the use of saturated-hydrocarbon-based slurries will facilitate wet processing and rapid laser sintering of proton-conducting ceramic electrolytes.

36 MATERIALS SCIENCE↗

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent Fast Wave Coupling and Heating Studies on NSTX, with Possible Implications for ITER

The goal of the high harmonic fast wave (HHFW) research on NSTX is to maximize the coupling of RF power to the core of the plasma by minimizing the coupling of RF power to edge loss processes. HHFW core plasma heating efficiency in helium and deuterium L-mode discharges is found to improve markedly on NSTX when the density 2 cm in front of the antenna is reduced below that for the onset of perpendicular wave propagation (n{sub onset}{proportional_to}B*k{sub parallel}{sup 2}/{omega}). In NSTX, the observed RF power losses in the plasma edge are driven in the vicinity of the antenna as opposed to resulting from multi-pass edge damping. PDI surface losses through ion-electron collisions are estimated to be significant. Recent spectroscopic measurements suggest that additional PDI losses could be caused by the loss of energetic edge ions on direct loss orbits and perhaps result in the observed clamping of the edge rotation. Initial deuterium H-mode heating studies reveal that core heating is degraded at lower k{sub {phi}}(-8 m{sup -1} relative to 13 m{sup -1}) as for the L-mode case at elevated edge density. Fast visible camera images clearly indicate that a major edge loss process is occurring from the plasma scrape off layer (SOL) in the vicinity of the antenna and along the magnetic field lines to the lower outer divertor plate. Large type I ELMs, which are observed at both k{sub {phi}} values, appear after antenna arcs caused by precursor blobs, low level ELMs, or dust. For large ELMs without arcs, the source reflection coefficients rise on a 0.1 ms time scale, which indicates that the time derivative of the reflection coefficient can be used to discriminate between arcs and ELMs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Establishment of very uniform gas-flow pattern in the process chamber for microwave-excited high-density plasma by ceramic shower plate

The authors developed a ceramic upper shower plate used in the microwave-excited high-density plasma process equipment incorporating a dual shower-plate structure to establish a very uniform gas-flow pattern in the process chamber. Thousands of very fine gas-injection holes are implemented on this Al{sub 2}O{sub 3} upper shower plate with optimized allocation to establish a uniform gas-flow pattern of plasma-excitation gases and radical-generation gases for generating intended radicals in the plasma-excitation region. The size of these fine holes must be 50 {mu}m or less in diameter and 8 mm or more in length because these holes perform an essential role: They completely avoid the plasma excitation in these fine holes and upper gas-supply regions resulting from the plasma penetration into these regions from excited high-density plasma, even if very high-density plasma greater than 1x10{sup 12} cm{sup -3} is excited just under the ceramic upper shower plate by microwaves supplied from the radial line slot antenna. On the other hand, various process gases, such as material gases for film formations and etching gases, are supplied from the lower shower plate installed in the diffusion plasma region to this very uniform gas-flow pattern region of plasma-excitation gases and radical-generation gases. As a result, the process gases are supplied to the wafer surface in a very effective manner without excess decomposition of those process gas molecules and undesired reaction-product deposition on the inner surface of the process chamber. The process results are improved drastically by introducing the newly developed ceramic upper shower plate. But also, process uniformity on the entire wafer is improved with drastically reducing reaction-product deposition on the inner surface of the process chamber.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reduction of the interfacial trap density of indium-oxide thin film transistors by incorporation of hafnium and annealing process

The stable operation of transistors under a positive bias stress (PBS) is achieved using Hf incorporated into InO{sub x}-based thin films processed at relatively low temperatures (150 to 250 °C). The mobilities of the Hf-InO{sub x} thin-film transistors (TFTs) are higher than 8 cm{sup 2}/Vs. The TFTs not only have negligible degradation in the mobility and a small shift in the threshold voltage under PBS for 60 h, but they are also thermally stable at 85 °C in air, without the need for a passivation layer. The Hf-InO{sub x} TFT can be stable even annealed at 150 °C for positive bias temperature stability (PBTS). A higher stability is achieved by annealing the TFTs at 250 °C, originating from a reduction in the trap density at the Hf-InO{sub x}/gate insulator interface. The knowledge obtained here will aid in the realization of stable TFTs processed at low temperatures.

36 MATERIALS SCIENCE↗

MINLP for regularized symbolic regression with applications to data-driven modeling of critical minerals processes

The poster summarizes recent advances in symbolic regression developed as part of the PrOMMiS project over the past year. In particular, it describes the comparison of surrogates for critical minerals (CM) & rare earth element (REE) recovery flowsheets obtained via symbolic regression and ALAMO. It also compares the predictive ability and solvability of optimization models that incorporate these surrogates.

36 MATERIALS SCIENCE↗

Recovery of dilute aqueous butanol by membrane vapor extraction with dodecane or mesitylene

A novel, nearly isothermal, nonselective-membrane separation process, membrane vapor extraction (MVE), efficiently recovers butanol from a dilute aqueous solution, for example, from a fermentation broth (Liu et al., 2015). In MVE, feed and solvent liquids are not in contact; they are separated by vapor. Therefore, compared to conventional extraction, MVE avoids formation of difficult-to-separate emulsions. In MVE, a semi-volatile aqueous solute (e.g., butanol) vaporizes at the upstream side of a membrane, diffuses as a vapor through the membrane pores, and subsequently condenses and dissolves into a high-boiling nonpolar solvent, favorable to the solute but not to water. Design analysis of a 1.5-m long, 30-m 2 membrane-area countercurrent MVE unit for processing 2-wt% aqueous butanol by dodecane solvent at 40 °C indicates over 90% recovery of the feed butanol with essentially no water loss and with very low energy requirement (Liu et al., 2015). The separation factor is over 1500. However, the published design study gives no experimental evidence for the calculated MVE separation. Here, we present experimental data to validate the MVE process. We use an omniphobic (i.e., hydrophobic and oleophobic), 0.2-µm pore-diameter Versapor®200 R membrane (Pall Corporation, Exton, PA) housed in a 6-cm wide by 10-cm long plate-and-frame channeled flow cell with 0.8-cm gap thickness. Membrane transfer area is 28 cm 2 . The membrane flow cell is designed for minimal axial concentration change and is operated in the transient mode between two recirculating flow loops. 2-wt% aqueous butanol is extracted into dodecane or mesitylene at 25 or 40 °C. Also, 1.5-wt% furfural is extracted into dodecane at 40 °C. Since vapor transport across the membrane contributes minimal resistance, MVE performance is governed by mass transfer through feed and solvent boundary layers. Mass-transfer coefficients are determined from the Graetz-Lévêque analysis of laminar thin-slit flow (Bird et al., 2002). Predicted extraction performance agrees well with experiment using no adjustable parameters. Finally, consistent with the initial multistage-design analysis (Liu et al., 2015), our new bench-scale experimental results confirm that MVE is a viable separation process to recover dilute semi-volatile biosolutes from water with minimal energy requirement. Preliminary analysis of downstream solute recovery from the extract via distillation is more efficient than that for pervaporation because of insignificant water carry over through the MVE membrane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SPRUCE Deep Peat Heating (DPH) Peat Water Content and Temperature for Experimental Plot Cores, June 2014 through June 2015

This data set provides the peat water content and peat temperature at time of sampling for peat cores collected before and during the SPRUCE Deep Peat Heating (DPH) study. Cores were collected during three sampling events: 03 June 2014, 09 September 2014, and 16 June 2015. Two cores were extracted from hollow locations in each of the 10 experimental plots (4, 6, 8, 10, 11, 13, 16, 17, 19, and 20). The five ambient plots (5, 7, 14, and 21) were not included in the DPH sampling efforts. See Table 1. Cores were partitioned into samples at 11 depth increments: 0-10, 10-20, 20-30, 30-40, 40-50, 50-75, 75-100, 100-125, 125-150, 150-175, and 175-200 cm below surface of the hollow. The DPH study was undertaken to evaluate possible rapid responses of deep peat carbon (C) stocks, microbial communities, and biogeochemical cycling processes to unprecedented temperatures. In June 2014, deep soil heating was initiated at 5 warming levels (+0, +2.25, +4.5, +6.75 and +9 °C) with 2 replicate plots per level. Warming levels at depth were achieved over a 25 (+ 2.25 °C) to 60-day (+9 °C) period depending on the target treatment temperatures. Data file – There is one comma-separated (*.csv) file with peat core water content and temperature at time of sampling, plus the amount of dried archived material retained after analyses. User Note: In this third release, four variables related to extrapolations of peat core temperature were removed. See the Data Set History table for additional details. 25-150, 150-175, and 175-200 cm below surface of the hollow.

54 ENVIRONMENTAL SCIENCES↗

Investigation of in situ high temperature sensor based on the direct absorption spectroscopy signal of ammonia gas for coal-fired power plant

The selective catalytic reduction and non-selective catalytic reduction (SCR/SNCR) are the most popular de-NOx processes for coal-fired power plant, where the real-time temperature is a significant parameter. A new developed tunable diode laser spectroscopy used for measuring the temperature of ammonia (NH{sub 3}) in the process of SCR/SNCR influenced by strong exhaust gas matrices CO{sub 2} and H{sub 2}O was presented in this paper. Two lines near 6605 cm{sup −1} were selected, with rather weak temperature dependency and minimal interface from CO{sub 2} and H{sub 2}O according to HITRAN12 database. A homemade heating equipment for high temperature laser spectroscopy measurement was developed based on an ARM microcontroller. The temperature calibration experiments of absorption lines were carried out at variable concentrations under different temperatures. The spectral signals of 2.5%, 3.5% and 4.5% NH{sub 3} were observed for validation of the generalization and robustness of the sensor. The calibration and validation experimental results show that the maximum measurement error and global average error of the temperature sensor with the temperature ranging from 453 to 653 K are less than 2% and 1.38%, respectively. It demonstrates that our proposed sensor with high accuracy and linearity, and can be utilized to measure the temperature in SNCR/SCR process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗