Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Sensitivity enhancement of grating interferometer based two-dimensional sensor arrays using two-wavelength readout

Diffraction gratings integrated with microelectromechanical systems (MEMS) sensors offer displacement measurements with subnanometer sensitivity. However, the sensitivity of the interferometric readout may drop significantly based on the gap between the grating and the reference surface. A two-wavelength (2-{lambda}) readout method was previously tested using a single MEMS sensor for illustrating increased displacement measurement capability. This work demonstrates sensitivity enhancement on a sensor array with large scale parallelization ({approx}20,000 sensors). The statistical representation, which is developed to model sensitivity enhancement within a grating based sensor array, is supported by experimental results using a thermal sensor array. In the experiments, two lasers at different wavelengths (633 and 650 nm) illuminate the thermal sensor array from the backside, time-sequentially. The diffracted first order light from the array is imaged onto a single CCD camera. The target scene is reconstructed by observing the change in the first diffracted order diffraction intensity for both wavelengths. Merging of the data from two measurements with two lasers was performed by taking the larger of the two CCD measurements with respect to the reference image for each sensor. {approx}30% increase in the average sensitivity was demonstrated for a 160x120 pixel IR sensor array. Proposed architecture is also applicable to a variety of sensing applications, such as parallel biosensing and atomic force microscopy, for improved displacement measurements and enhanced sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of a cross-sectional profile of a thread gauge using a sinusoidally vibrating interference pattern

A sinusoidally vibrating interference pattern (SVIP) is used as an exact spatial scale in order to measure a cross-sectional profile of a thread gauge. The SVIP is projected on the thread gauge surface, and lights diffracted and reflected from the end points of the thread gauge surface are extracted by spatial frequency filtering in an imaging system to make an image of the end points whose positions are decided by the peak positions of amplitude distributions in the image. The coordinates of the end points or the cross-sectional profile of the thread gauge is obtained from the phases measured at the positions of the end points, phase distribution of the SVIP on a CCD image sensor, and the pixel positions of the CCD image sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Distortion Lens Design for Large Scintillators

Tomographic imaging of large objects from an x-ray source require a 240 mm square scintillator that is imaged onto a 90 mm square charge-coupled device (CCD) with <0.01% distortion. A large pellicle and internal folding mirror keep the optical elements and the CCD camera out of the x-ray beam path to minimize shielding requirements. Better imaging is needed for 2-D digital radiography and computer tomography (3-D) on the Los Alamos National Laboratory’s Microtron x-ray–generating source, a bremsstrahlung source with endpoint energies of 6, 10, 15, and 20 MeV. Large objects are placed into the x-ray beam and rotated between radiographs. X-rays are deposited into scintillators that are viewed with digital cameras. Better light gathering is needed because the scintillators emit low levels of light. Earlier imaging techniques used film in contact with the scintillator. Our design goal is to match the resolution of the digital camera system to that of the film. 3-D tomography requires extremely low distortion of the collected images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-shot local measurement of terahertz correlated second harmonic generation in laser air plasma filaments

We present a single-shot detection method of terahertz correlated second harmonic generation in plasma-based sources by directly mixing an optical probe into femtosecond laser-induced plasma filaments in air. Furthermore, the single-shot second harmonic trace is obtained by measuring a second harmonic generation on a conventional CCD with a spatiotemporally distorted probe beam. The system shows a spectrometer resolution of 22 fs/pixel on the CCD and a true resolution on the order of the probe pulse duration. With considerable THz peak electric field strength, this formalism can open the door to single-shot THz detection without bandwidth limitations.

47 OTHER INSTRUMENTATION↗

Structure of a HIV-1 IN-Allosteric inhibitor complex at 2.93 Å resolution: Routes to inhibitor optimization

HIV integrase (IN) inserts viral DNA into the host genome and is the target of the strand transfer inhibitors (STIs), a class of small molecules currently in clinical use. Another potent class of antivirals is the allosteric inhibitors of integrase, or ALLINIs. ALLINIs promote IN aggregation by stabilizing an interaction between the catalytic core domain (CCD) and carboxy-terminal domain (CTD) that undermines viral particle formation in late replication. Ongoing challenges with inhibitor potency, toxicity, and viral resistance motivate research to understand their mechanism. Here, we report a 2.93 Å X-ray crystal structure of the minimal ternary complex between CCD , CTD , and the ALLINI BI-224436. This structure reveals an asymmetric ternary complex with a prominent network of π-mediated interactions that suggest specific avenues for future ALLINI development and optimization.

60 APPLIED LIFE SCIENCES↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

The structure of braitschite, a calcium rare earth borate

The crystal structure of braitschite, Ca6.15Na0.85RE2.08[B6O7(OH)3(O,OH)3]4(H2O), is reported here in space group P6/m with unit-cell parameters a = 12.1506(6), c = 7.3678(4) Å, and V = 942.03(8) Å3. Data were collected from a single crystal using a MoKα source and a CCD detector, solved by direct methods, and refined to an R factor of 2.81%. The mineral structure consists of hexaborate fundamental building blocks that polymerize along [001] and are bound by Ca2+ and REE3+ counter-ions. The framework forms hexagonal channels, which are occupied alternately by Ca2+ cations and water molecules. In an investigation of its thermal stability, braitschite maintains its crystallinity to a temperature of 400 °C, after which it undergoes decomposition. Using Rietveld refinements against powder X-ray diffraction data, we were able to track the loss of water molecules in channels and hydroxyl groups in the covalent B-O network with increasing temperature.

58 GEOSCIENCES↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Optical Design of a Broadband Infrared Spectrometer for Bunch Length Measurement at the Linac Coherent Light Source

The electron pulses generated by the Linac Coherent Light Source at the SLAC National Accelerator Laboratory occur on the order of tens of femtoseconds and cannot be directly measured by conventional means. The length of the pulses can instead be reconstructed by measuring the spectrum of optical transition radiation emitted by the electrons as they move toward a conducting foil. Because the emitted radiation occurs in the mid-infrared from 0.6 to 30 microns a novel optical layout is required. Using a helium-neon laser with wavelength 633 nm, a series of gold-coated off-axis parabolic mirrors were positioned to direct a beam through a zinc selenide prism and to a focus at a CCD camera for imaging. Constructing this layout revealed a number of novel techniques for reducing the aberrations introduced into the system by the off—axis parabolic mirrors. The beam had a recorded radius of less than a millimeter at its final focus on the CCD imager. This preliminary setup serves as a model for the spectrometer that will ultimately measure the LCLS electron pulse duration.

43 PARTICLE ACCELERATORS↗

The Dark Energy Spectrometer (DESpec): A Multi-Fiber Spectroscopic Upgrade of the Dark Energy Camera and Survey for the Blanco Telescope

We describe an initiative to build and use the Dark Energy Spectrometer (DESpec), a wide-field spectroscopic survey instrument for the Blanco 4-meter telescope at Cerro Tololo Inter-American Observatory (CTIO) in Chile. A new system with about 4000 robotically positioned optical fibers will be interchangeable with the CCD imager of the existing Dark Energy Camera (DECam), accessing a field of view of 3.8 square degrees in a single exposure. The proposed instrument will be operated by CTIO and available for use by the astronomy community. Our collaboration proposes to use DESpec to conduct a wide, deep spectroscopic survey to study Dark Energy, sharing the survey products with the community, while providing community access to fibers in parallel with survey observations. In a survey of ~350 nights, the DESpec collaboration proposes to obtain spectroscopic redshifts for ~8 million galaxies over 5000 sq. deg. selected from precision imaging from the Dark Energy Survey (DES). This Dark Energy Spectroscopic Survey will advance our knowledge of cosmic expansion and structure growth significantly beyond that obtainable with imaging-only surveys. Since it adds a spectroscopic third dimension to the same sky as DES, the world’s largest and deepest photometric survey, DESpec will enable a powerful array of new, increasingly precise techniques to discriminate among alternative explanations of cosmic acceleration, such as Dark Energy and Modified Gravity. In the 2020 decade, a wider-area spectroscopic survey will enhance the science reach of the next-generation imaging project, LSST, by providing spectroscopy for tens of millions of galaxies and QSO’s over its 15,000-20,000 square degree survey area. DESpec will create a comprehensive, three dimensional, critically-sampled map of large scale cosmic structure – a database encompassing the “cosmic web” of galaxies and clusters over the entire, deeply-imaged southern sky – over most of cosmic history. DESpec will take advantage of the substantial hardware infrastructure recently built for DECam to achieve excellent science at low cost and low technical and schedule risk. It will be mounted in the DECam prime focus cage with its hexapod positioning system (recently installed on the Blanco Telescope) and will share the four largest DECam optical corrector elements. It will be routinely interchangeable with the DECam CCD imager and preserve f/8 secondary capability, to allow flexible use of the telescope. The robotically positioned optical fibers will feed 10 relatively simple, high-throughput spectrometers outfitted with existing, spare, red-sensitive, science-grade DECam CCDs. An Atmospheric Dispersion Compensator similar to existing designs can be accommodated in the existing DECam filter slot. Examples that meet requirements for all major subsystems are in existing or highly developed instruments, showing that cost, technical, and schedule risks are manageable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Performance of Charge-Coupled Devices in Ambient Conditions - Oral presentation [Slides]

Telescope surveys have given us a great deal of information about our universe, but the images they capture carry with them an inherent limitation. The question then is how do we take this information to the next level? The answer: the Dark Energy Spectroscopic Instrument (DESI). DESI is an instrument that will measure the distance to tens of millions of galaxies in our night sky. This information can be combined with already existing images to construct a three dimensional map of our universe providing a great deal of new opportunities for cosmological research. The DESI guidance system consists of 10 detectors called charge-coupled devices (CCDs). Each CCD is made of silicon atoms that emit electrons when struck with light, the electrons are counted and then used to reconstruct an image. But, CCDs suffer from an issue known as ‘dark current’ which are false counts that come from thermal motions of the silicon atoms. This is particularly problematic since they contribute to the uncertainty of a measurement without contributing to our signal. This causes a drop in the signal to noise ratio, a value that needs to be maximized in order to meet DESI’s high precision requirements. This summer was spent ensuring the DESI guidance system would meet its specifications. Data was collected using a CCD of the same type that would be used on DESI and the effectiveness of dark current removal was tested. Exposures were taken for a wide range of temperatures and exposure lengths and a number of dark current removal methods were implemented. While further testing is required, the initial results are quite promising and the DESI guidance system is on track to meet its specifications

47 OTHER INSTRUMENTATION↗

Bentonite-Clay Waste Form for the Immobilization of Cesium and Strontium from Fuel Processing Waste Streams

The physical properties of a surrogate waste form containing cesium, strontium, rubidium, and barium sintered into bentonite clay were evaluated for several simulant feed streams: chlorinated cobalt dicarbollide/polyethylene glycol (CCD-PEG) strip solution, nitrate salt, and chloride salt feeds. We sintered bentonite clay samples with a loading of 30 mass% of cesium, strontium, rubidium, and barium to a density of approximately 3 g/cm 3 . Sintering temperatures of up to 1000°C did not result in volatility of cesium. Instead, there was an increase in crystallinity of the waste form upon sintering to 1000ºC for chloride- and nitrate-salt loaded clays. The nitrate salt feed produced various cesium pollucite phases, while the chloride salt feed did not produce these familiar phases. In fact, many of the x-ray diffraction peaks could not be matched to known phases. Assemblages of silicates were formed that incorporated the Sr, Rb, and Ba ions. Gas evolution during sintering to 1000°C was significant (35% weight loss for the CCD-PEG waste-loaded clay), with significant water being evolved at approximately 600°C.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solid electrolytes for solid-state and lithium-sulfur batteries

The stringent demands placed on batteries by emerging vehicle technologies such as plug-in and battery electric vehicles suggest that improvements in the safety and performance of electrochemical energy storage devices, as well as concurrent reductions in their cost, are highly desirable. Current strategies for improving performance have largely focused on Li-ion battery chemistries. In this project went beyond the state of the art by pursuing electrolyte chemistries that will enable the use of Li metal anodes and sulfur cathodes, either concurrently in a solid state Li-S battery, or as a means to achieve a Li metal anode which is stable upon cycling. More specifically, our effort advanced strategies to enable Li metal anodes for myriad beyond Li-ion chemistries . LLZO garnet (Li 7 La 3 Zr 2 O 12 ) is the first bulk-scale ceramic electrolyte to exhibit the combination of superionic conductivity (1mS/cm at 298K), high shear modulus (61 GPa) to suppress Li dendrite penetration, and apparent electrochemical stability (0-6V vs Li/Li + ), thus enabling Li metal anodes. However, to date there are no reports confirming LLZO can tolerate current densities > 1mA/cm 2 , thus demonstrating relevance to PHEV/EV batteries. Our goal was to investigate the mechanisms that govern the Li-LLZO interfacial stability as a function of current density. We determined that defects in polycrystalline LLZO reduce the critical current density (CCD). Primarily contaminants on the LLZO surface and grain boundaries were the primary defects the limited the CCD. Using our experience with synthesis and processing (Sakamoto and Wolfenstine) and sophisticated materials characterization (Nanda), we precisely controlled atomistic and microstructural defects and correlated their effects on controlling the critical current density. These data fed into multi-scale computation models (Siegel and Monroe) to isolate and quantify the roles that each defect played in controlling the critical current density. Bridging this knowledge gap allowed us to demonstrate that LLZO can withstand > 1mA/cm 2 .

25 ENERGY STORAGE↗

Using Charge-Coupled Devices to Characterize Neutron Events

Ultra-cold neutrons (UCNs) are free neutrons with less than 300 neV of kinetic energy. UCNs are useful for studying position-dependent quantum states, as they are only influenced by Earth’s gravity. Precise measurements of these quantum states can give great insight into dark matter, dark energy, and quantum gravity. We have been calibrating and testing a charge-coupled device (CCD) so that it can be coated with boron-10 to track the reaction products produced between the boron and UCNs. Additionally, we have been using a simulation software package called The Stopping and Range of Ions in Matter (SRIM), which uses Monte Carlo methods to track ions in a chosen target. This package is useful to find a correlation between incident ion angles and 2D variance of the CCD hit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-GeV dark matter and neutrino searches with Skipper-CCDs: status and prospects

Thick fully-depleted charge-coupled devices (CCDs) with high-resistivity silicon are used in a wide range of scientific applications, from particle detection to astronomical imaging. Their low noise and high charge collection efficiency allow us to reach unprecedented sensitivity to physical processes with low-energy transfers. The newly-developed Skipper-CCD enhances this sensitivity by reducing the read-out noise reaching a sub-electron resolution. In this work, we summarize the fundamentals of the skipper-CCD operation and the prospects for both sub-GeV dark-matter searches and the detection of coherent elastic neutrino-nucleus scattering. A brief discussion of the challenges associated with the construction of the foreseen detectors with multi-kilogram target mass is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Proper Motions Study of the Globular Cluster NGC 3201

With a high value of heliocentric radial velocity, a retrograde orbit, and suspected to have an extragalactic origin, NGC 3201 is an interesting globular cluster for kinematical studies. Our purpose is to calculate the relative proper motions (PMs) and membership probability for the stars in the wide region of globular cluster NGC 3201. PM based membership probabilities are used to isolate the cluster sample from the field stars. The membership catalog will help address the question of chemical inhomogeneity in the cluster. Archive CCD data taken with a wide-field imager (WFI) mounted on the ESO 2.2 m telescope are reduced using the high-precision astrometric software developed by Anderson et al. for the WFI images. The epoch gap between the two observational runs is ∼14.3 years. To standardize the BVI photometry, Stetson’s secondary standard stars are used. The CCD data with an epoch gap of ∼14.3 years enables us to decontaminate the cluster stars from field stars efficiently. The median precision of PMs is better than ∼0.8 mas yr{sup −1} for stars having V<18 mag that increases up to ∼1.5 mas yr{sup −1} for stars with 18<V<20 mag. Kinematic membership probabilities are calculated using PMs for stars brighter than V∼20 mag. An electronic catalog of positions, relative PMs, BVI magnitudes, and membership probabilities in the ∼19.7 × 17 arcmin{sup 2} region of NGC 3201 is presented. We use our membership catalog to identify probable cluster members among the known variables and X-ray sources in the direction of NGC 3201.

79 ASTRONOMY AND ASTROPHYSICS↗

sashevis (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashemfr (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗