Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Experiments on plasma arcs at a water–air interface

An exploding water plasma experiment at UCLA investigated the expansion and morphology of a fireball with and without an external magnetic field. Diagnostics include photographs and movies (which may be downloaded) acquired with a framing camera, magnetic probes, and visible light spectra. The expansion and internal magnetic fields are very different from the unmagnetized case when a magnetic field of order 300G is applied along the expansion axis. Visible light spectra are brighter and additional lines are seen in the presence of the magnetic field. The experiment can serve as a platform for studies of interfacial mixing and possibly shed light on very different processes such as laser target physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural network for 3D inertial confinement fusion shell reconstruction from single radiographs

In inertial confinement fusion (ICF), x-ray radiography is a critical diagnostic for measuring implosion dynamics, which contain rich three-dimensional (3D) information. Traditional methods for reconstructing 3D volumes from 2D radiographs, such as filtered backprojection, require radiographs from at least two different angles or lines of sight (LOS). In ICF experiments, the space for diagnostics is limited, and cameras that can operate on fast timescales are expensive to implement, limiting the number of projections that can be acquired. To improve the imaging quality as a result of this limitation, convolutional neural networks (CNNs) have recently been shown to be capable of producing 3D models from visible light images or medical x-ray images rendered by volumetric computed tomography. Here, we propose a CNN to reconstruct 3D ICF spherical shells from single radiographs. We also examine the sensitivity of the 3D reconstruction to different illumination models using preprocessing techniques such as pseudo-flatfielding. To resolve the issue of the lack of 3D supervision, we show that training the CNN utilizing synthetic radiographs produced by known simulation methods allows for reconstruction of experimental data as long as the experimental data are similar to the synthetic data. We also show that the CNN allows for 3D reconstruction of shells that possess low mode asymmetries. Further comparisons of the 3D reconstructions with direct multiple LOS measurements are justified.

3D Reconstruction↗

X-ray imaging of Rayleigh–Taylor instabilities using Fresnel zone plate at the National Ignition Facility

Being able to provide high-resolution x-ray radiography is crucial in order to study hydrodynamic instabilities in the high-energy density regime at the National Ignition Facility (NIF). Current capabilities limit us to about 20 μm resolution using pinholes, but recent studies have demonstrated the high-resolution capability of the Fresnel zone plate optics at the NIF, measuring 2.3 μm resolution. Using a zinc Heα line at 9 keV as a backlighter, we obtained a radiograph of Rayleigh–Taylor instabilities with a measured resolution of under 3 μm. Two images were taken with a time integrated detector and were time gated by a laser pulse duration of 600 ps, and a third image was taken with a framing camera with a 100 ps time gate on the same shot and on the same line of sight. The limiting factors on image quality for these two cases are the motion blur and the signal to noise ratio, respectively. We also suggest solutions to increase the image quality.

Do, A. (ORCID:0000000174372147)↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic field imaging in a laboratory plasma

In laboratory plasmas, arrays of probes have typically been used to measure the evolution of the magnetic field topology. Here, we present initial image-based measurements of the magnetic topology in a low-temperature plasma using a purely optical diagnostic. Laser induced fluorescence measurements of neutral velocity distribution functions are made using a fast camera, imaging the Zeeman splitting of σ-peaks in neutral argon. The separation of σ-peaks provides spatially resolved magnetic field magnitude measurements with a detection threshold on the order of 10 G

36 MATERIALS SCIENCE↗

Poisson_CCD: A dedicated simulator for modeling CCDs

A dedicated simulator, Poisson_CCD, has been constructed which models astronomical CCDs by solving Poisson’s equation numerically and simulating charge transport within the CCD. The potentials and free carrier densities within the CCD are self-consistently solved for, giving realistic results for the charge distribution within the CCD storage wells. The simulator has been used to model the CCDs that are being used to construct the LSST digital camera. The simulator output has been validated by comparing its predictions with several different types of CCD measurements, including astrometric shifts, brighter-fatter induced pixel–pixel covariances, saturation effects, and diffusion spreading. The code is open source and freely available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements of the imploding plasma sheath in triple-nozzle gas-puff z pinches

Gas-puff z-pinch implosions are characterized by the formation of a dense annular plasma shell, the sheath, that is driven to the axis by magnetic forces and therefore subject to the magneto-Rayleigh–Taylor instability. Here, the conditions within these sheaths are measured on the 1-MA COBRA generator at Cornell University for various gas species and initial fill densities. The gas-puff loads are initialized by a 7 cm diameter triple-nozzle gas valve assembly with concentric outer and inner annular nozzles and a central gas jet. Thomson scattering and laser interferometry provide spatially resolved flow, temperature, and electron density profiles midway through the implosion, while extreme ultraviolet pinhole cameras record the evolution of the plasma column and photoconducting diodes measure x-ray emission. Analysis of the scattering spectra includes a means of discriminating between thermal and non-thermal broadening to test for the presence of hydrodynamic turbulence. Two types of sheath profiles are observed, those with sharp discontinuities at the leading edge and those with smooth gradients. In both cases, non-thermal broadening is generally peaked at the front of the sheath and exhibits a characteristic decay length that roughly scales with the sheath ion mean free path. Here, we demonstrate that this non-thermal broadening term is inconsistent with laminar velocity gradients and is more consistent with dissipative turbulence driven by unstable plasma waves in a collisionless shock. The resulting differences in sheath profile are then set by the sheath ion collisionality in a manner consistent with recent 1D kinetic simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep modeling of plasma and neutral fluctuations from gas puff turbulence imaging

The role of turbulence in setting boundary plasma conditions is presently a key uncertainty in projecting to fusion energy reactors. To robustly diagnose edge turbulence, we develop and demonstrate a technique to translate brightness measurements of HeI line radiation into local plasma fluctuations via a novel integrated deep learning framework that combines neutral transport physics and collisional radiative theory for the 3 3 D - 2 3 P transition in atomic helium with unbounded correlation constraints between the electron density and temperature. The tenets for experimental validity are reviewed, illustrating that this turbulence analysis for ionized gases is transferable to both magnetized and unmagnetized environments with arbitrary geometries. Based on fast camera data on the Alcator C-Mod tokamak, we present the first two-dimensional time-dependent experimental measurements of the turbulent electron density, electron temperature, and neutral density, revealing shadowing effects in a fusion plasma using a single spectral line.

47 OTHER INSTRUMENTATION↗

Classification of computed thermal tomography images with deep learning convolutional neural network

Thermal tomography (TT) is a computational method for the reconstruction of depth profile of the internal material defects from Pulsed Infrared Thermography (PIT) nondestructive evaluation. Here, the PIT method consists of recording material surface temperature transients with a fast frame infrared camera, following thermal pulse deposition on the material surface with a flashlamp and heat diffusion into material bulk. TT algorithm obtains depth reconstructions of thermal effusivity, which has been shown to provide visualization of the subsurface internal defects in metals. In many applications, one needs to determine the defect shape and orientation from reconstructed effusivity images. Interpretation of TT images is non-trivial because of blurring, which increases with depth due to the heat diffusion-based nature of image formation. We have developed a deep learning convolutional neural network (CNN) to classify the size and orientation of subsurface material defects in TT images. CNN was trained with TT images produced with computer simulations of 2D metallic structures (thin plates) containing elliptical subsurface voids. The performance of CNN was investigated using test TT images developed with computer simulations of plates containing elliptical defects, and defects with shapes imported from scanning electron microscopy images. CNN demonstrated the ability to classify radii and angular orientation of elliptical defects in previously unseen test TT images. We have also demonstrated that CNN trained on the TT images of elliptical defects is capable of classifying the shape and orientation of irregular defects.

42 ENGINEERING↗

Topography of bent crystals with microradian resolution in one dimension

Optimum performance in x-ray imaging and spectroscopy of plasmas with bent crystals is achievable only when the crystal reflects the x rays theoretically perfectly across its entire surface. However, typical thin quartz (101̄1) crystal samples kept flat by direct attachment to a flat substrate reflect 8 keV x rays differently across their surface, on a scale comparable to the ideal rocking curve. Additional processing improves the uniformity. Irradiation of flat crystals with collimated, monochromatic x rays in rocking curve topography shows such problems directly, with microradian resolution. Nonuniform x-ray reflection is more difficult to document for strongly bent crystals because, then, monochromatic, collimated x rays satisfy the Bragg condition only along a narrow stripe that may be too narrow to resolve with the available cameras. However, it can be resolved with a knife edge that moves through the reflected x rays with the necessary spatial precision as demonstrated here for a bent silicon crystal. This shows qualitatively similar imperfections in the reflection as flat quartz and as the bent quartz analyzers reported on previously with lower resolution.

Pereira, N. R. (ORCID:0000000290569596)↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Diagnosing low-mode (ℓ < 6) and mid-mode (6 ≤ ℓ ≤ 60) asymmetries in the post-stagnation phase of laser-direct-drive deuterium–tritium cryogenic implosions on OMEGA

Low- and mid-mode perturbations are possible candidates for performance limitations in cryogenic direct-drive implosions on the OMEGA laser at the Laboratory of Laser Energetics. Simulations with a 3D hydrocode demonstrated that hotspot imagers do not show evidence of the shell breakup in the dense fuel. However, these same simulations revealed that the low- and mid-mode perturbations in the dense fuel could be diagnosed more easily in the post-stagnation phase of the implosion by analyzing the peak in the x-ray emission limb at the coronal–fuel interface than before or at the stagnation phase. In experiments, the asymmetries are inferred from gated images of the x-ray emission of the implosion by using a 16-pinhole array imager filtered to record x-ray energies >800 eV and an x-ray framing camera with 40-ps time integration and 20-μm spatial resolution. Furthermore, a modal analysis is applied to the spatial distribution of the x-ray emission from deuterium and tritium cryogenic implosions on OMEGA recorded after the bang time to diagnose the low- and mid-mode asymmetries, and to study the effect that the beam-to-target ratio (Rb/Rt) has on the shell integrity.

47 OTHER INSTRUMENTATION↗

Upgrades to the gamma ray imager on DIII-D enabling access to high flux hard x-ray measurements during the runaway electron plateau phase (invited)

The Gamma Ray Imager (GRI) is a pinhole camera providing 2D imaging of MeV hard x-ray (HXR) bremsstrahlung emission from runaway electrons (REs) over the poloidal cross section of the DIII-D tokamak. We report a series of upgrades to the GRI expanding the access to RE scenarios from the diagnosis of a trace amount of REs to high flux HXR measurements during the RE plateau phase. We present the implementation of novel gamma ray detectors based on LYSO and YAP crystals coupled to multi-pixel photon counters, enabling a count rate in excess of 1 MHz. Finally, we highlight new insights into the RE physics discovered during the current quench and RE plateau phase experiments as the result of these upgrades.

Lvovskiy, A. (ORCID:0000000236491169)↗

Scattered-light uniformity imager for diagnosing laser absorption asymmetries on OMEGA

Light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. Observations from OMEGA implosions show much larger scattered-light asymmetries than predictions. A new instrument has been developed to absolutely measure the scattered-light intensity and nonuniformity for the purpose of diagnosing the asymmetry. The scattered-light uniformity imager (SLUI) diagnostic records the variation in scattered-light intensity over a transmission diffuser using a charge-coupled device (CCD)/lens assembly. At the standard operating position, an 11.3° (f/2.5) cone of light is collected. A stray light baffle, debris shield, and antireflection absorbing filter are also incorporated into the diagnostic payload inserted into the target chamber. The imaging parts of the diagnostic (light baffle, vacuum window, filters, lens, and CCD camera) are located outside the target chamber. Five SLUIs have been built and deployed in OMEGA’s ten-inch manipulator diagnostic ports, covering almost 5% of the emission surface, enabling an absolute scattered-light measurement should be within a few percent of the global average. Each SLUI system is calibrated offline, providing absolute scattered-light intensity measurements. Based on the measured point spread function, each diffuser plate image contains over 20 000 independent scattered-light absolute-intensity measurements of the variation over the collection cone. SLUI provides a platform to study scattered light and absorption asymmetries, and their possible sources.

47 OTHER INSTRUMENTATION↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a new charge exchange recombination spectroscopy diagnostic for impurity transport experiments at Wendelstein 7-X

In this study, we present the design of a new charge exchange recombination spectroscopy (CXRS) system for Wendelstein 7-X (W7-X), which aims at measuring line radiation from highly ionized iron impurities after laser blow off injections over transport timescales. New fiber bundles with a core diameter of 600 µm have been added to one of the existing optical systems at W7-X used for CXRS. The fibers direct collected light to five newly developed single channel high frame rate F/2.8 spectrometers. The new custom-made spectrometers are built using entirely off-the-shelf and 3D printed components, and employ a round-to-linear fiber bundle, instead of an entrance slit, to maximize light throughput. The detector is an ultra-low readout noise EM-CCD camera capable of frame rates of up to 10 000 fps for about 500 consecutive frames when operated using a single readout channel. Such high frame rates will enable the study of inward convection of injected impurities. An initial sensitivity study is performed using a newly developed Markov chain Monte Carlo approach based on the pySTRAHL impurity transport code. This study indicates that, with the addition of the new CX diagnostic, impurity convection velocities can be inferred.

Instruments & Instrumentation↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. Here, in this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗