Impact of Assembly-Specific Conditions on BWR Burnup Credit
Because boiling water reactors use control blades during operation, there can be significant changes to the local axial power shape, coolant density profile, and other parameters when the blades are inserted. Previous work examined the reactor operating parameters that impact cask reactivity. These previous studies identified limiting conditions for fuel cask reactivity or the direction of trends with cask reactivity (e.g., lower coolant densities result in higher cask reactivity). However, using limiting conditions for all parameters simultaneously is unrealistic. When the control blades are inserted deeply into the reactor—a limiting condition—the power is reduced and the void fraction decreases—a less limiting condition. This paper identifies the impacts of using assembly-specific conditions for control blade history, coolant density profile, burnup profile, and fuel temperature profile. Results indicate that cask reactivity is reduced when using assembly-specific operating conditions versus combining limiting conditions for the individual parameters of interest. The magnitude of reactivity reduction for using assembly- specific conditions varies based on each assembly and its operating conditions.