Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

MO-C-BRB-00: President’s Symposium: Revitalizing Scientific Excellence: Turning Research Into Clinical Reality Through Translational Research

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-01: Introduction [ Diagnostic radiology and radiation oncology ]

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-02: ASTRO President [ Diagnostic radiology and radiation oncology ]

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-03: RSNA President [ Diagnostic radiology and radiation oncology ]

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-04: The role of the NIH in funding innovations in science and medicine

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-05: Translating NIH funding to a [potential] clinical device in breast cancer radiation therapy

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-C-BRB-06: Translating NIH / NIBIB funding to clinical reality in quantitative diagnostic imaging

Diagnostic radiology and radiation oncology are arguably two of the most technologically advanced specialties in medicine. The imaging and radiation medicine technologies in clinical use today have been continuously improved through new advances made in the commercial and academic research arenas. This symposium explores the translational path from research through clinical implementation. Dr. Pettigrew will start this discussion by sharing his perspectives as director of the National Institute of Biomedical Imaging and Bioengineering (NIBIB). The NIBIB has focused on promoting research that is technological in nature and has high clinical impact. We are in the age of precision medicine, and the technological innovations and quantitative tools developed by engineers and physicists working with physicians are providing innovative tools that increase precision and improve outcomes in health care. NIBIB funded grants lead to a very high patenting rate (per grant dollar), and these patents have higher citation rates by other patents, suggesting greater clinical impact, as well. Two examples of clinical translation resulting from NIH-funded research will be presented, in radiation therapy and diagnostic imaging. Dr. Yu will describe a stereotactic radiotherapy device developed in his laboratory that is designed for treating breast cancer with the patient in the prone position. It uses 36 rotating Cobalt-60 sources positioned in an annular geometry to focus the radiation beam at the system’s isocenter. The radiation dose is delivered throughout the target volume in the breast by constantly moving the patient in a planned trajectory relative to the fixed isocenter. With this technique, the focal spot dynamically paints the dose distribution throughout the target volume in three dimensions. Dr. Jackson will conclude this symposium by describing the RSNA Quantitative Imaging Biomarkers Alliance (QIBA), which is funded in part by NIBIB and is a synergistic collaboration between medical physicists, radiologists, oncologists, industry representatives, and other stakeholders. The mission of QIBA is to improve the accuracy and practicality of quantitative image-based biomarkers by increasing precision across devices, patients, and time, an essential step in incorporating quantitative imaging biomarkers into radiology practice. Validated quantitative imaging biomarkers are necessary to support precision medicine initiatives, multimodality / multiparametric applications in medicine, treatment planning and response assessment, and radiogenomics applications. Current applications in the QIBA portfolio extend to cancer diagnosis and treatment, pulmonary diseases, and neurological disorders. The overall goal of this symposium is to illustrate the bidirectional exchange between medical research and clinical practice. Revitalizing scientific excellence in clinical medical physics challenges practitioners to identify clinical limitations, which then drive research innovation; research funded by the NIH and other agencies develops technological solutions to these limitations, which are translated to the care environment to ultimately improve clinical practice in radiology and radiation oncology.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-09: Quantification of Nanoparticle Heating and Concentration for MR-Guided Laser Interstitial Thermal Therapy

Purpose: Nanoparticle Mediated Laser Interstitial Thermal Therapy (npLITT) is a technique that utilizes tumor localized optically activated nanoparticles to increase the conformality of laser ablation procedures. Temperatures in these procedures are dependent on the particle concentration which generally cannot be measured noninvasively prior to therapy. In this work we attempt to quantify particle concentration in vivo by estimating the increase in R2* relaxation induced by bifunctional magnetic resonance (MR)-visible gold-based nanoparticles (SPIO@Au) and relate it to the temperature increase observed during real time MR temperature imaging (MRTI) of laser ablation. Methods: SPIO@Au nanoparticles (90nm) were synthesized containing a silica-iron core (for MR visibility via R2*) and gold shell (for near-infrared absorption). High resolution R2* maps were acquired before and after injecting four different particle concentrations (saline,1e10, 5e10, and 10e10 particles/mL) into HN5 flank xenografts. Tumors were monitored using MRTI during treatment with an interstitial fiber. (1 watt, 808 nm, 3 minutes) Results: The maximum temperature within the tumors increased linearly with concentration of injected particles, reaching 34.0, 37.6, 45.8, and 55.4 {sup 0}C for saline, 1e10, 5e10 and 10e10 particles/mL injections, respectively (R2=.994). The highest temperatures occur at the injection site rather than the fiber, confirming that SPIO@Au nanoparticles are the primary absorber. The differences between the median R2* measured at the injection site and the rest of the tumor were −6, 134, 111, 156 s-1 for the saline,1e10,5e10 and 10e10 particles/mL injections, respectively. This R2* change is consistent with the measured relaxivity for the 1e10 particles/mL injection but does not maintain linearity at higher concentrations. Conclusion: Bifunctional SPIO@Au nanoparticles are a promising technology for providing noninvasive estimates of particle concentration via MRI and temperature increase in npLITT procedures. Future experiments will focus on lower, physiologically relevant particle concentrations and spin echo R2 mapping to better quantify the particle concentration. This research was supported by the National Institutes of Health and National Cancer Institute under Award Numbers TL1TR000369 and P30CA016672 and was conducted at the MD Anderson Center for Advanced Biomedical Imaging in-part with equipment support from General Electric Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-11: Impact of Using Multi-Slice Training Sets On the Performance of a Channelized Hotelling Observer in a Low-Contrast Detection Task in CT

Purpose: To investigate using multiple CT image slices from a single acquisition as independent training images for a channelized Hotelling observer (CHO) model to reduce the number of repeated scans for CHO-based CT image quality assessment. Methods: We applied a previously validated CHO model to detect low contrast disk objects formed from cross-sectional images of three epoxy-resin-based rods (diameters: 3, 5, and 9 mm; length: ∼5cm). The rods were submerged in a 35x 25 cm2 iodine-doped water filled phantom, yielding-15 HU object contrast. The phantom was scanned 100 times with and without the rods present. Scan and reconstruction parameters include: 5 mm slice thickness at 0.5 mm intervals, 120 kV, 480 Quality Reference mAs, and a 128-slice scanner. The CHO’s detectability index was evaluated as a function of factors related to incorporating multi-slice image data: object misalignment along the z-axis, inter-slice pixel correlation, and number of unique slice locations. In each case, the CHO training set was fixed to 100 images. Results: Artificially shifting the object’s center position by as much as 3 pixels in any direction relative to the Gabor channel filters had insignificant impact on object detectability. An inter-slice pixel correlation of >∼0.2 yielded positive bias in the model’s performance. Incorporating multi-slice image data yielded slight negative bias in detectability with increasing number of slices, likely due to physical variations in the objects. However, inclusion of image data from up to 5 slice locations yielded detectability indices within measurement error of the single slice value. Conclusion: For the investigated model and task, incorporating image data from 5 different slice locations of at least 5 mm intervals into the CHO model yielded detectability indices within measurement error of the single slice value. Consequently, this methodology would Result in a 5-fold reduction in number of image acquisitions. This project was supported by National Institutes of Health grants R01 EB017095 and U01 EB017185 from the National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

WE-AB-204-11: Development of a Nuclear Medicine Dosimetry Module for the GPU-Based Monte Carlo Code ARCHER

Purpose: To develop a nuclear medicine dosimetry module for the GPU-based Monte Carlo code ARCHER. Methods: We have developed a nuclear medicine dosimetry module for the fast Monte Carlo code ARCHER. The coupled electron-photon Monte Carlo transport kernel included in ARCHER is built upon the Dose Planning Method code (DPM). The developed module manages the radioactive decay simulation by consecutively tracking several types of radiation on a per disintegration basis using the statistical sampling method. Optimization techniques such as persistent threads and prefetching are studied and implemented. The developed module is verified against the VIDA code, which is based on Geant4 toolkit and has previously been verified against OLINDA/EXM. A voxelized geometry is used in the preliminary test: a sphere made of ICRP soft tissue is surrounded by a box filled with water. Uniform activity distribution of I-131 is assumed in the sphere. Results: The self-absorption dose factors (mGy/MBqs) of the sphere with varying diameters are calculated by ARCHER and VIDA respectively. ARCHER’s result is in agreement with VIDA’s that are obtained from a previous publication. VIDA takes hours of CPU time to finish the computation, while it takes ARCHER 4.31 seconds for the 12.4-cm uniform activity sphere case. For a fairer CPU-GPU comparison, more effort will be made to eliminate the algorithmic differences. Conclusion: The coupled electron-photon Monte Carlo code ARCHER has been extended to radioactive decay simulation for nuclear medicine dosimetry. The developed code exhibits good performance in our preliminary test. The GPU-based Monte Carlo code is developed with grant support from the National Institute of Biomedical Imaging and Bioengineering through an R01 grant (R01EB015478)

60 APPLIED LIFE SCIENCES↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

SU-F-E-17: A Dedicated Teaching and Research Linac as a Stepping Stone to Introduce Medical Physics to Students

Purpose: This work describes how a non-clinical, research and teaching Linac is used as an extremely motivating and exciting way to introduce students to medical physics. Methods: The dedicated facility was inaugurated in 2014. The facility is composed of a fully equipped and functional state-of-the-art Varian TrueBeam Linac and a complete set of physics instruments and QA phantoms for the Linac and onboard imaging. The Linac bunker and treatment console are oversized such that a class of 12–15 can comfortably fit, seated if needed for longer sessions. A 3cr undergraduate laboratory course that includes medical imaging, x-ray source characterization (mAs, kVp, and filtering) and many others including an introductory Linac laboratory was created. The latter is composed of one general 4-hours session and a weekly 4-hours session for teams of two students. The general session includes a hands-on presentation of the Linac, its environment and a formal safety and radiation protection course (with an exam). Results: Since the winter of 2015, senior undergraduate (total of 15) pursuing either the medical physics or the biomedical engineering tracks can register. At the Linac, the students are allowed full control of the experiments, including set-up and irradiation. Supervisor intervention is limited to safety concerns for students or equipment. Measurements of output factors using two chambers (regular and small field) for various field sizes (1×1 to 30×30 cm{sup 2}) and of detailed depth-dose curves for 6 MV, 6 and 12 MeV beams are to be performed and discussed in a formal report. Conclusion: Full access to, and control of, a Linac is the high point of this course. It provides a glimpse of medical physics and generates an experimental background for those continuing to CAMPEP programs. This dedicated, non-clinical facility further enable enhance CAMPEP graduate teaching and research activities not possible with a clinical device.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-10: Microimaging for Different Degrees of Human Cavernous Hemangioma of Liver by Using In-Line Phase-Contrast Imaging CT

Purpose: Cavernous hemangioma of the liver (CHL) is the most common benign solid tumor of the liver. In this study, we quantitative assessment the different degrees of CHL from microscopic viewpoint by using in-line phase-contrast imaging CT (ILPCI-CT). Methods: The experiments were performed at x-ray imaging and biomedical application beamline (BL13W1) of Shanghai Synchrotron Radiation Facility (SSRF) in China. Three typical specimens at different stages, i.e., mild, moderate and severe human CHL were imaged using ILPCI-CT at 16keV without contrast agents. The 3D visualization of different degrees of CHL samples were presented using ILPCI-CT. Additionally, quantitative evaluation of the CHL features, such as the range of hepatic sinusoid equivalent diameters in different degrees of CHL samples, the ratio of the hepatic sinusoid to the CHL tissue, were measured. Results: The planar image clearly displayed the dilated hepatic sinusoids in microns. There was no normal hepatic vascular found in the all CHL samples. Different stages of CHL samples were presented with vivid shapes and stereoscopic effects by using 3D visualization. The equivalent diameters of hepatic sinusoids in three degrees CHL were different. The equivalent diameters of the hepatic sinusoids in mild CHL, range from 60 to 120 µm. The equivalent diameters of the hepatic sinusoids in moderate CHL, range from 65 to 190 µm. The equivalent diameters of the hepatic sinusoids in severe CHL, range from 95 to 215 µm. The ratio of the hepatic sinusoid to the mild, moderate and severe CHL tissue were 3%, 16% and 21%, respectively. Conclusion: The results show that the high degree of sensitivity of the ILPCI-CT technique and demonstrate the feasibility of accurate visualization of different stage human CHL. ILPCI-CT may offers a potential use in non-invasive study and analysis of CHL.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-04: Multiple Penalties with Different Orders for Structure Adaptive CBCT Reconstruction

Purpose: To combine total variation (TV) and Hessian penalty in a structure adaptive way for cone-beam CT (CBCT) reconstruction. Methods: TV is a widely used first order penalty with good ability in suppressing noise and preserving edges but leads to the staircase effect in regions with smooth intensity transition. The second order Hessian penalty can effectively suppress the staircase effect with extra cost of blurring object edges. To take the best of both penalties we proposed a novel method to combine both for CBCT reconstruction in a structure adaptive way. The proposed method adaptively determined the weight of each penalty according to the geometry of local regions. An specially-designed exponent term with image gradient involved was used to characterize the local geometry such that the weights for Hessian and TV were 1 and 0 respectively at uniform local regions and 0 and 1 at edge regions. For other local regions the weights varied from 0 to 1. The objective functional was minimized using the majorzationminimization approach. We evaluated the proposed method on a modified 3D shepp-logan and a CatPhan 600 phantom. The full-width-at-halfmaximum (FWHM) and contrast-to-noise (CNR) were calculated. Results: For 3D shepp-logan the reconstructed images using TV had an obvious staircase effect while those using the proposed method and Hessian preserved the smooth transition regions well. FWHMs of the proposed method TV and Hessian penalty were 1.75 1.61 and 3.16 respectively, indicating that both TV and the proposed method is able to preserve edges. For CatPhan 600 CNR values of the proposed method were similar to those of TV and Hessian. Conclusion: The proposed method retains favorable properties of TV like preserving edges and also has the ability in better preserving gradual transition structure as Hessian does. All methods performs similarly in suppressing noise. This work was supported in part by National Natural Science Foundation of China (NNSFC) under Grant Nos.60971112 and 61375018 grants from the Cancer Prevention and Research Institute of Texas (RP130109 and RP110562-P2) National Institute of Biomedical Imaging and Bioengineering (R01 EB020366) and a grant from the American Cancer Society (RSG-13-326-01-CCE).

60 APPLIED LIFE SCIENCES↗

WE-FG-207B-04: Noise Suppression for Energy-Resolved CT Via Variance Weighted Non-Local Filtration

Purpose: The photon starvation problem is exacerbated in energy-resolved CT, since the detected photons are shared by multiple energy channels. Using pixel similarity-based non-local filtration, we aim to produce accurate and high-resolution energy-resolved CT images with significantly reduced noise. Methods: Averaging CT images reconstructed from different energy channels reduces noise at the price of losing spectral information, while conventional denoising techniques inevitably degrade image resolution. Inspired by the fact that CT images of the same object at different energies share the same structures, we aim to reduce noise of energy-resolved CT by averaging only pixels of similar materials - a non-local filtration technique. For each CT image, an empirical exponential model is used to calculate the material similarity between two pixels based on their CT values and the similarity values are organized in a matrix form. A final similarity matrix is generated by averaging these similarity matrices, with weights inversely proportional to the estimated total noise variance in the sinogram of different energy channels. Noise suppression is achieved for each energy channel via multiplying the image vector by the similarity matrix. Results: Multiple scans on a tabletop CT system are used to simulate 6-channel energy-resolved CT, with energies ranging from 75 to 125 kVp. On a low-dose acquisition at 15 mA of the Catphan©600 phantom, our method achieves the same image spatial resolution as a high-dose scan at 80 mA with a noise standard deviation (STD) lower by a factor of >2. Compared with another non-local noise suppression algorithm (ndiNLM), the proposed algorithms obtains images with substantially improved resolution at the same level of noise reduction. Conclusion: We propose a noise-suppression method for energy-resolved CT. Our method takes full advantage of the additional structural information provided by energy-resolved CT and preserves image values at each energy level. Research reported in this publication was supported by the National Institute Of Biomedical Imaging And Bioengineering of the National Institutes of Health under Award Number R21EB019597. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

WE-G-204-00: Post-Graduate Training of the Next Generation of Academic Medical Physicists

While many indicators for academic medical physics are distressing – jobs are tight, demands on clinical time are high (and getting worse) and national funding has been flat for several years (meaning less money in reality) the present is perhaps one of the most exciting times in cancer research history, and medical physicists have an opportunity to make a difference. Many of us predict the impact of medical physics on cancer research over the next decade to be more significant than ever. Why is that? First, medical imaging is used for every cancer patient in developed countries. Every improvement in the acquisition, processing or analysis of radiological images has the potential to impact patients. The use of radiation therapy is at an all-time high – and virtually cannot be performed without medical physics. Many of the advances in both biomedical imaging and radiation oncology are the result of the hard work of academic medical physicists who are thinking of the next generation of technologies that will be used against cancer or an even broader spectrum of diseases. A career in academic medical physics is demanding, particularly for those with clinical responsibilities. As the demands for justification of their clinical effort become increasingly metricized, the ability to do “unfunded research” will become even more difficult. This means that many will have to generate external salary support to justify their efforts in research and development. This comes at a time when funding for research is compressed and harder to obtain. Generally speaking, if you are not contributing 50% or more of your effort to research, you are competing at a disadvantage and it is very unlikely you will get an NIH/NCI/NIBIB grant. Furthermore, in the ongoing effort to improve patient care and safety, we have developed credentialing pathways that now require at least two-years of residency training. This full-time clinical training creates a gap in the research trajectory of graduate students who aspire to academic positions with an expectation for extramural funding. To address this, several residency programs have created hybrid programs where the two-years of clinical training is combined with one or two years of research effort to allow candidates to further establish an academic identity and to ensure adequate academic productivity to compete for a beginning faculty position. In conclusion, while the path to a successful career in academic medical physics is steep and sometimes hard to follow, reaching the apex is worth the journey. Different paths to a career in medical physics are available, you just have to decide which one is right for you. If improving cancer care is your goal as a physicist, then academic medical physics is the job for you!.

60 APPLIED LIFE SCIENCES↗

WE-G-204-01: Building a Career in Academic Medical Physics: The Hardest and Best Job You Will Ever Have!

While many indicators for academic medical physics are distressing – jobs are tight, demands on clinical time are high (and getting worse) and national funding has been flat for several years (meaning less money in reality) the present is perhaps one of the most exciting times in cancer research history, and medical physicists have an opportunity to make a difference. Many of us predict the impact of medical physics on cancer research over the next decade to be more significant than ever. Why is that? First, medical imaging is used for every cancer patient in developed countries. Every improvement in the acquisition, processing or analysis of radiological images has the potential to impact patients. The use of radiation therapy is at an all-time high – and virtually cannot be performed without medical physics. Many of the advances in both biomedical imaging and radiation oncology are the result of the hard work of academic medical physicists who are thinking of the next generation of technologies that will be used against cancer or an even broader spectrum of diseases. A career in academic medical physics is demanding, particularly for those with clinical responsibilities. As the demands for justification of their clinical effort become increasingly metricized, the ability to do “unfunded research” will become even more difficult. This means that many will have to generate external salary support to justify their efforts in research and development. This comes at a time when funding for research is compressed and harder to obtain. Generally speaking, if you are not contributing 50% or more of your effort to research, you are competing at a disadvantage and it is very unlikely you will get an NIH/NCI/NIBIB grant. Furthermore, in the ongoing effort to improve patient care and safety, we have developed credentialing pathways that now require at least two-years of residency training. This full-time clinical training creates a gap in the research trajectory of graduate students who aspire to academic positions with an expectation for extramural funding. To address this, several residency programs have created hybrid programs where the two-years of clinical training is combined with one or two years of research effort to allow candidates to further establish an academic identity and to ensure adequate academic productivity to compete for a beginning faculty position. In conclusion, while the path to a successful career in academic medical physics is steep and sometimes hard to follow, reaching the apex is worth the journey. Different paths to a career in medical physics are available, you just have to decide which one is right for you. If improving cancer care is your goal as a physicist, then academic medical physics is the job for you!.

60 APPLIED LIFE SCIENCES↗