Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BOOSTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Wake loss and energy spread factor of the LEReC Booster cavity caused by short range wake field

LEReC project uses a DC photoemission gun with multi-alkali (CsK 2 Sb or NaK 2 Sb) cathode [1]. To get 24 mm “flat-top” distribution, 32 Gaussian laser bunches with 0.6 mm rms length are stacked together with 0.75 mm distance [2]. In this case one cannot simply use a 1 cm rms length Gaussian/step/delta bunch for short range wake field simulation since a 0.6 mm bunch contains frequency much higher than the 1 cm bunch. A short range wake field simulation was done using CST Particle Studio™ with 0.6 mm rms Gaussian bunch at the speed of light, and this result was compared with the result for 1 cm rms Gaussian bunch in Figure 1, from where one notice that the wake potential for the 0.6 mm bunch is ~10 times higher than that of the 1 cm bunch. The wake potential of the 0.6 mm bunch, as well as the charge distribution, was then “shift and stack” every 0.75 mm, the normalized results are shown in Figure 2. The wake loss factor (WLF) is the integration of the product of wake potential and normalized bunch charge, and the energy spread factor (ESF) is the rms deviation from the average energy loss. It is calculated by summing the weighted squares of the differences and taking the square root of the sum. These two factors were then divided by β 2 for 1.6 MV beam energy. The wake loss factor is at 0.86 V/pC and energy spread factor is at 0.54 V/pC rms. With 100 pC electron bunch, the energy spread inter-bunch is 54 V rms.

43 PARTICLE ACCELERATORS↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed. Survey and alignment provides the foundation for positioning the beam-guiding magnet structures in all 6 degrees of freedom within the required tolerances. Although the tools and instrumentation available for this task have changed over the years and faster and more accurate measurements are possible, only limited control of the environmental conditions is possible. This ultimately sets an upper limit for the achievable measurement and subsequent control network accuracy. At the same time, the control of environmental variables (temperature, humidity) will be fully taken advantage of during the building of NSLS-II , opening up the possibility of ever-increasing accuracy unheard of only five years ago.

42 ENGINEERING↗

Supplementary Shielding Specifications for the NSLS-II Booster Enclosure

Bulk shielding at NSLS-II has been designed to reduce the ambient dose rates to < 5.0 μSv/h (0.5 mrem/h) at the exterior surface of the concrete shielding, during typical operation. This limits the maximum exposure to < 10 mSv/y (1,000 mrem/y) at the occupied areas, assuming 2,000 hours ofoccupancy per year.

36 MATERIALS SCIENCE↗

NSLS-II Booster Survey and Alignment Systems

This section outlines the survey and alignment requirements and the technology and tools for achieving the NSLS-II equipment positioning goals. The required alignment tolerances are defined primarily by the physics requirements of the accelerator. The tight tolerances dictated by the physics requirements are an order of magnitude tighter than the tolerances of second generation light sources (NSLS) and on level with those at third generation light sources (Soleil, Diamond). These extraordinary position requirements necessitate a concerted R&D engineering effort to identify and develop the survey methodology needed to meet these requirements. As of this date, the methodology is still evolving to balance cost and time constraints while still maintaining the integrity of the survey and alignment systems. State-of-the art equipment including Laser Trackers and Laser Arms have been purchased and used extensively in the pursuit of meeting the NSLS-II survey tolerances. No new technology will need to be developed to meet the alignment requirements but new techniques will be pursued and developed.

36 MATERIALS SCIENCE↗

FY2020-21 parameters for Gold ions in Booster, AGS, and RHIC

Sections 1 through 6 of this report give parameters for low-energy gold ions circulating in RHIC at injection and in AGS at extraction. Section 7 gives parameters for Au79+ ions circulating in RHIC at the standard injection magnetic rigidity of 81.11378003 Tm. Sections 8 through 10 give parameters for medium-energy Au79+ ions circulating in RHIC at 31.2, 26.5, 19.5, 13.5 GeV per nucleon. To reach these energies, acceleration in RHIC is required. The magnetic rigidity at RHIC injection for these setups is 60.3050632557 Tm. The corresponding ion energy is 7.30950517185 GeV per nucleon.

43 PARTICLE ACCELERATORS↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Improving NOvA&#x27;s Sterile Neutrino Search with the Booster Neutrino Beam

The NOvA experiment’s most recent search for eV-scale sterile neutrinos is systematically limited in the region of parameter space where $\Delta m^2_{41} \gtrsim 1~\mathrm{eV}^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies; improving sensitivity here is high-priority. When added directly into the fit, additional data samples which are subject to orthogonal systematic uncertainties act as in-situ constraints, breaking the degeneracy between systematic uncertainties and sterile-induced oscillations. The NOvA experiment consists of two functionally identical detectors, 14.6 mrad off-axis of the NuMI beam, with the Near Detector (Far Detector) 1 km (810 km) from the beam source. The Near Detector’s position on-site at Fermilab means that it is also able to observe neutrinos from a second neutrino beam, the BNB, 160 mrad off-axis. NOvA has been taking BNB data since 2015, but has not yet analysed these data. The BNB and NuMI are subject to different beam-related uncertainties, allowing us to leverage this sample as an in-situ constraint. This poster will present the current status, preliminary simulations, and potential additional uses of this unique experimental setup

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗