Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Variable-Domain Displacement Transfer Functions for Converting Surface Strains into Deflections for Structural Deformed Shape Predictions

Variable-Domain Displacement Transfer Functions were formulated for shape predictions of complex wing structures, for which surface strain-sensing stations must be properly distributed to avoid jointed junctures, and must be increased in the high strain gradient region. Each embedded beam (depth-wise cross section of structure along a surface strain-sensing line) was discretized into small variable domains. Thus, the surface strain distribution can be described with a piecewise linear or a piecewise nonlinear function. Through discretization, the embedded beam curvature equation can be piece-wisely integrated to obtain the Variable-Domain Displacement Transfer Functions (for each embedded beam), which are expressed in terms of geometrical parameters of the embedded beam and the surface strains along the strain-sensing line. By inputting the surface strain data into the Displacement Transfer Functions, slopes and deflections along each embedded beam can be calculated for mapping out overall structural deformed shapes. A long tapered cantilever tubular beam was chosen for shape prediction analysis. The input surface strains were analytically generated from finite-element analysis. The shape prediction accuracies of the Variable- Domain Displacement Transfer Functions were then determined in light of the finite-element generated slopes and deflections, and were fofound to be comparable to the accuracies of the constant-domain Displacement Transfer Functions

displacement transfer functions↗

NIAC Phase I Study Final Report on Large Ultra-Lightweight Photonic Muscle Space Structures

The research goal is to develop new tools support NASA's mission of understanding of the Cosmos by developing cost effective solutions that yield a leap in performance and science data. 'Maikalani' in Hawaiian translates to, "knowledge we gain from the cosmos." Missions like Hubble have fundamentally changed humanity's view of the cosmos. Last year's Nobel prize in physics was a result of astronomical discoveries. $9B class JWST size (6.5 meter diameter) space telescopes, when launched are anticipated to rewrite our knowledge of physics. Here we report on a neoteric meta-material telescope mirror technology designed to enable a factor of 100 or more reduction in areal density, a factor of 100 reduction in telescope production and launch costs as well as other advantages; a leap to enable missions to image the cosmos in unprecedented detail, with the associated gain in knowledge. Whether terahertz, visible or X-ray, reflectors used for high quality electromagnetic imaging require shape accuracy (surface figure) to far better than 1 wavelength (lambda) of the incident photons, more typically lambda/10 or better. Imaging visible light therefore requires mirror surfaces that approximate a desired curve (e.g. a sphere or paraboloid) with smooth shape deviation of th less than approximately 1/1000 the diameter of a human hair. This requires either thick high modulus material like glass or metal, or actuators to control mirror shape. During Phase I our team studied a novel solution to this systems level design mass/shape tradespace requirement both to advance the innovative space technology concept and also to help NASA and other agencies meet current operational and future mission requirements. Extreme and revolutionary NASA imaging missions such as Terrestrial Planet Imager (TPI) require lightweight mirrors with minimum diameters of 20 to 40 meters. For reference, NASA's great achievement; the Hubble space telescope, is only 2.4 meters in diameter. What is required is a way to make large inexpensive deployable mirrors where the cost is measured in millions, not billions like current efforts. For example we seek an interim goal within 10 years of a Hubble size (2.4m) primary mirror weighing 1 pound at a cost of 10K in materials. Described here is a technology using thin ultra lightweight materials where shape can be controlled simply with a beam of light, allowing imaging with incredibly low mass yet precisely shaped mirrors. These " Photonic Muscle" substrates will eventually make precision control of giant s p a c e apertures (mirrors) possible. OCCAM substrates make precision control of giant ultra light-weight mirror apertures possible. This technology is posed to create a revolution in remote sensing by making large ultra lightweight space telescopes a fiscal and material reality over the next decade.

Cosmos↗

Gamma ray sources using imperfect relativistic mirrors

The collective backscattering of intense laser radiation by energetic electron beams is considered. Exact solutions for the radiation field are obtained, for arbitrary electron pulse shapes and laser intensities. The electron beams act as imperfect nonlinear mirrors on the incident laser radiation. This collective backscattering process can lead to the development of new sources of ultrashort pulse radiation in the gamma-ray domain. Numerical examples show that, for plausible experimental conditions, intense pulses of gamma rays, due to the double Doppler shift of the harmonics of the incident laser radiation, can be produced using the available technology, with durations less than one attosecond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Inverse planning for four-dimensional (4D) volumetric modulated arc therapy

Purpose: To develop a 4D volumetric modulated arc therapy (VMAT) inverse planning framework. Methods: 4D VMAT inverse planning aims to derive an aperture and weight modulated arc therapy treatment plan that optimizes the accumulated dose distribution from all gantry angles and breathing phases. Under an assumption that the gantry rotation and patient breathing are synchronized (i.e., there is a functional relationship between the phase of the patient breathing cycle and the beam angle), the authors compute the contribution from different respiration phases through the registration of the phased CT images. The accumulative dose distribution is optimized by iteratively adjusting the aperture shape and weight of each beam through the minimization of the planning objective function. For comparison, traditional 3D VMAT plans are also performed for the two cases and the performance of the proposed technique is demonstrated. Results: A framework for 4D VMAT inverse planning has been proposed. With the consideration of the extra dimension of time in VMAT, a tighter target margin can be achieved with a full duty cycle, which is otherwise not achievable simultaneously by either 3D VMAT optimization or gated VMAT. Conclusions: The 4D VMAT planning formulism proposed here provides useful insight on how the ''time'' dimension can be exploited in rotational arc therapy to maximally compensate for the intrafraction organ motion.

60 APPLIED LIFE SCIENCES↗

Three-dimensional finite strip analysis of elastic solids

Finite element shape functions were combined with beam eigenfunctions to formulate three-dimensional finite strips. Because of the orthogonality of the beam functions, three-dimensional problems were reduced to a series of two-dimensional problems, often with stiffness matrices of very narrow bandwidth. Isoparametric and high order finite element shape functions were used in the formulation of the 3-D finite strips. Numerical examples such as the static and free vibration analyses of simply supported thick plates are presented. Results were compared with existing solutions and good agreements were obtained in all cases.

Cheung, M. S.↗

A piecewise continuous Timoshenko beam model for the dynamic analysis of tapered beam-like structures

Distributed parameter modeling offers a viable alternative to the finite element approach for modeling large flexible space structures. The introduction of the transfer matrix method into the continuum modeling process provides a very useful tool to facilitate the distributed parameter model applied to some more complex configurations. A uniform Timoshenko beam model for the estimation of the dynamic properties of beam-like structures has given comparable results. But many aeronautical and aerospace structures are comprised of non-uniform sections or sectional properties, such as aircraft wings and satellite antennas. This paper proposes a piecewise continuous Timoshenko beam model which is used for the dynamic analysis of tapered beam-like structures. A tapered beam is divided into several segments of uniform beam elements. Instead of arbitrarily assumed shape functions used in finite element analysis, the closed-form solution of the Timoshenko beam equation is used. Application of the transfer matrix method relates all the elements as a whole. By corresponding boundary conditions and compatible conditions a characteristic equation for the global tapered beam has been developed, from which natural frequencies can be derived. A computer simulation is shown in this paper, and compared with the results obtained from the finite element analysis. While piecewise continuous Timoshenko beam model decreases the number of elements significantly; comparable results to the finite element method are obtained.

Shen, Ji Yao↗

SU-F-T-336: A Quick Auto-Planning (QAP) Method for Patient Intensity Modulated Radiotherapy (IMRT)

Purpose: The aim of this study is to develop a quick auto-planning system that permits fast patient IMRT planning with conformal dose to the target without manual field alignment and time-consuming dose distribution optimization. Methods: The planning target volume (PTV) of the source and the target patient were projected to the iso-center plane in certain beameye- view directions to derive the 2D projected shapes. Assuming the target interior was isotropic for each beam direction boundary analysis under polar coordinate was performed to map the source shape boundary to the target shape boundary to derive the source-to-target shape mapping function. The derived shape mapping function was used to morph the source beam aperture to the target beam aperture over all segments in each beam direction. The target beam weights were re-calculated to deliver the same dose to the reference point (iso-center) as the source beam did in the source plan. The approach was tested on two rectum patients (one source patient and one target patient). Results: The IMRT planning time by QAP was 5 seconds on a laptop computer. The dose volume histograms and the dose distribution showed the target patient had the similar PTV dose coverage and OAR dose sparing with the source patient. Conclusion: The QAP system can instantly and automatically finish the IMRT planning without dose optimization.

60 APPLIED LIFE SCIENCES↗

Distributed Sensing of a Cantilever Beam and Plate Using a Fiber Optic Sensing System

As the capabilities of Fiber Optic Sensing Systems continue to improve, their application to real-time distributed sensing for structural analysis and control of flexible systems is increasingly feasible. This paper will report experimental results on the use of a Fiber Optic Sensing System for static and dynamic shape estimation of a cantilever beam and plate. Demonstrating the use of this sensor technology in benchtop experiments is the first step in effectively incorporating fiber optic sensors in the Integrated Adaptive Wing Technology Maturation aeroelastic half-span wind tunnel model for real-time shape sensing and feedback for drag optimization, maneuver load alleviation, gust load alleviation, and flutter suppression control laws. The effectiveness of the sensing system will be analyzed and the application of these results to aeroelasticity experimentation will be discussed.

Heaney, Patrick S.↗

Peculiarities of the angular distribution of laser radiation intensity scattered by laser-spark plasma in air

The spatiotemporal study of the diagram of laser radiation scattering by the laser-spark plasma produced by 3-ns and 50-ns pulses is performed. It is shown that radiation appearing outside the laser beam cone is scattered during the first one - two nanoseconds after the air breakdown, when the spark plasma is located in the vicinity of the laser beam waist and has a shape close to spherical.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-BRE-05: Feasibility and Limitations of Laser-Driven Proton Therapy: A Treatment Planning Study

Purpose: Laser-acceleration of particles may offer a cost- and spaceefficient alternative for future radiation therapy with particles. Laser-driven particle beams are pulsed with very short bunch times, and a high number of particles is delivered within one laser shot which cannot be portioned or modulated during irradiation. The goal of this study was to examine whether good treatment plans can be produced for laser-driven proton beams and to investigate the feasibility of a laser-driven treatment unit. Methods: An exponentially decaying proton spectrum was tracked through a gantry and energy selection beam line design to produce multiple proton spectra with different energy widths centered on various nominal energies. These spectra were fed into a treatment planning system to calculate spot scanning proton plans using different lateral widths of the beam and different numbers of protons contained in the initial spectrum. The clinical feasibility of the resulting plans was analyzed in terms of dosimetric quality and the required number of laser shots as an estimation of the overall treatment time. Results: We were able to produce treatment plans with plan qualities of clinical relevance for a maximum initial proton number per laser shot of 6*10{sup 8}. However, the associated minimum number of laser shots was in the order of 10{sup 4}, indicating a long delivery time in the order of at least 15 minutes, when assuming an optimistic repetition rate of the laser system of 10 Hz. Conclusion: With the simulated beam line and the assumed shape of the proton spectrum it was impossible to produce clinically acceptable treatment plans that can be delivered in a reasonable time. The situation can be improved by a method or a device in the beam line which can modulate the number of protons from shot to shot. Supported by DFG Cluster of Excellence: Munich-Centre for Advanced Photonics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-217: A Comprehensive Monte-Carlo Study of Out-Of-Field Secondary Neutron Spectra in a Scanned-Beam Proton Therapy Treatment Room

Purpose: To simulate secondary neutron radiation-fields produced at different positions during phantom irradiation inside a scanning proton therapy gantry treatment room. Further, to identify origin, energy distribution and angular emission as function of proton beam energy. Methods: GEANT4 and FLUKA Monte-Carlo codes were used to model the relevant parts of the treatment room in a gantry-equipped pencil beam scanning proton therapy facility including walls, floor, metallic gantry-components, patient table and the homogeneous PMMA target. The proton beams were modeled based on experimental beam ranges in water and spot shapes in air. Neutron energy spectra were simulated at 0°, 45°, 90° and 135° relative to the beam axis at 2m distance from isocenter, as well as 11×11 cm2 fields for 75MeV, 140MeV, 200MeV and for 118MeV with 5cm PMMA range-shifter. The total neutron energy distribution was recorded for these four positions and proton energies. Additionally, the room-components generating secondary neutrons in the room and their contributions to the total spectrum were identified and quantified. Results: FLUKA and GEANT4 simulated neutron spectra showed good general agreement in the whole energy range of 10{sup −}9 to 10{sup 2} MeV. Comparison of measured spectra with the simulated contributions of the various room components helped to limit the complexity of the room model, by identifying the dominant contributions to the secondary neutron spectrum. The iron of the bending magnet and counterweight were identified as sources of secondary evaporation-neutrons, which were lacking in simplified room models. Conclusion: Thorough Monte-Carlo simulations have been performed to complement Bonner-sphere spectrometry measurements of secondary neutrons in a clinical proton therapy treatment room. Such calculations helped disentangling the origin of secondary neutrons and their dominant contributions to measured spectra, besides providing a useful validation of widely used Monte-Carlo packages in comparison to experimental data. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics (MAP)”.

60 APPLIED LIFE SCIENCES↗

Dynamic characteristic of a 30-cm mercury ion thruster

Measurements of the fluctuations of the discharge and beam plasmas of a 30 centimeter ion thruster were performed using 60 Hertz laboratory type power supplies. The time-varying properties of the discharge voltage and current, the ion beam current, and neutralizer keeper current were measured. The intensities of the fluctuations were found to depend on the beam and magnetic baffle currents. The shape of the frequency spectra of the discharge plasma fluctuations was found to be related to the beam and magnetic baffle currents. The measurements indicated that the discharge current fluctuations directly contribute to the beam current fluctuations and that the power supply characteristics modify these fluctuations.

Serafini, J. S.↗

Optimized manufacturing process for multilayer two-dimensional focusing mirrors in laboratory X-ray applications

Recent advances in laboratory X-ray applications require high-performance optical components that achieve exceptional imaging resolution and beam uniformity within compact experimental setups. Montel mirrors have become a preferred solution due to their unique dual-reflection focusing mechanism and a space-efficient design. Here, in this study, we present an effective manufacturing process for producing Montel mirrors tailored to focus laboratory X-ray beams. The mirrors were fabricated from single-crystal silicon substrates, chosen for their high mechanical stability and compatibility with precision polishing techniques. Our approach begins with the integration of a deterministic chemo-mechanical polishing (CMP)-based pre-shaping step followed by ion beam figuring (IBF), significantly improving manufacturing efficiency. Subsequently, our custom-developed advanced metrology and IBF techniques were employed for fabricating an off-axis, elliptical cylinder Montel mirror system with a 6-mrad total slope, with stringent optical specifications. While post-IBF processes, including multilayer coating, dicing, and gluing, introduced minor surface errors, yet their impact on performance remained negligible. The Montel mirrors manufactured with the optimized process exhibited significantly improved beam uniformity and a reduced focal spot size. These findings validate our approach as a viable solution for high-precision Montel mirror fabrication and facilitate further advancements in laboratory X-ray applications.

36 MATERIALS SCIENCE↗

Laser-driven electron beamlines generated by coupling laser-plasma sources with conventional transport systems

Laser-driven electron beamlines are receiving increasing interest from the particle accelerator community. In particular, the high initial energy, low emittance, and high beam current of the plasma based electron source potentially allow generating much more compact and bright particle accelerators than what conventional accelerator technology can achieve. Using laser-generated particles as injectors for generating beamlines could significantly reduce the size and cost of accelerator facilities. Unfortunately, several features of laser-based particle beams need still to be improved before considering them for particle beamlines and thus enable the use of plasma-driven accelerators for the multiple applications of traditional accelerators. Besides working on the plasma source itself, a promising approach to shape the laser-generated beams is coupling them with conventional accelerator elements in order to benefit from both a versatile electron source and a controllable beam. In this paper, we perform start-to-end simulations to generate laser-driven beamlines using conventional accelerator codes and methodologies. Starting with laser-generated electrons that can be obtained with established multi-hundred TW laser systems, we compare different options to capture and transport the beams. This is performed with the aim of providing beamlines suitable for potential applications, such as free electron lasers. In our approach, we have analyzed which parameters are critical at the source and from there evaluated different ways to overcome these issues using conventional accelerator elements and methods. We show that electron driven beamlines are potentially feasible, but exploiting their full potential requires extensive improvement of the source parameters or innovative technological devices for their transport and capture.

43 PARTICLE ACCELERATORS↗

SU-F-T-158: Experimental Characterization of Field Size Dependence of Dose and Lateral Beam Profiles of Scanning Proton and Carbon Ion Beams for Empirical Model in Air

Purpose: The Gaussian model for the lateral profiles in air is crucial for an accurate treatment planning system. The field size dependence of dose and the lateral beam profiles of scanning proton and carbon ion beams are due mainly to particles undergoing multiple Coulomb scattering in the beam line components and secondary particles produced by nuclear interactions in the target, both of which depend upon the energy and species of the beam. In this work, lateral profile shape parameters were fitted to measurements of field size dependence dose at the center of field size in air. Methods: Previous studies have employed empirical fits to measured profile data to significantly reduce the QA time required for measurements. From this approach to derive the weight and sigma of lateral profiles in air, empirical model formulations were simulated for three selected energies for both proton and carbon beams. Results: The 20%–80% lateral penumbras predicted by the double model for proton and single model for carbon with the error functions agreed with the measurements within 1 mm. The standard deviation between measured and fitted field size dependence of dose for empirical model in air has a maximum accuracy of 0.74% for proton with double Gaussian, and of 0.57% for carbon with single Gaussian. Conclusion: We have demonstrated that the double Gaussian model of lateral beam profiles is significantly better than the single Gaussian model for proton while a single Gaussian model is sufficient for carbon. The empirical equation may be used to double check the separately obtained model that is currently used by the planning system. The empirical model in air for dose of spot scanning proton and carbon ion beams cannot be directly used for irregular shaped patient fields, but can be to provide reference values for clinical use and quality assurance.

60 APPLIED LIFE SCIENCES↗

SU-E-T-243: MonteCarlo Simulation Study of Polymer and Radiochromic Gel for Three-Dimensional Proton Dose Distribution

Purpose: To estimate the three dimensional dose distributions in a polymer gel and a radiochromic gel by comparing with the virtual water phantom exposed to proton beams by applying Monte Carlo simulation. Methods: The polymer gel dosimeter is the compositeness material of gelatin, methacrylic acid, hydroquinone, tetrakis, and distilled water. The radiochromic gel is PRESAGE product. The densities of polymer and radiochromic gel were 1.040 and 1.0005 g/cm3, respectively. The shape of water phantom was a hexahedron with the size of 13 × 13 × 15 cm3. The proton beam energies of 72 and 116 MeV were used in the simulation. Proton beam was directed to the top of the phantom with Z-axis and the shape of beam was quadrangle with 10 × 10 cm2 dimension. The Percent depth dose and the dose distribution were evaluated for estimating the dose distribution of proton particle in two gel dosimeters, and compared with the virtual water phantom. Results: The Bragg-peak for proton particles in two gel dosimeters was similar to the virtual water phantom. Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in the identical region (4.3 cm) for 72 MeV proton beam. For 116 MeV proton beam, the Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in 9.9, 9.9 and 9.7 cm, respectively. The dose distribution of proton particles in polymer gel, radiochromic gel, and virtual water phantom was approximately identical in the case of 72 and 116 MeV energies. The errors for the simulation were under 10%. Conclusion: This work indicates the evaluation of three dimensional dose distributions by exposing proton particles to polymer and radiochromic gel dosimeter by comparing with the water phantom. The polymer gel and the radiochromic gel dosimeter show similar dose distributions for the proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

Nonlinear flap-lag-extensional vibrations of rotating, pretwisted, preconed beams including Coriolis effects

The effects of pretwist, precone, setting angle, Coriolis forces and second degree geometric nonlinearities on the natural frequencies, steady state deflections and mode shapes of rotating, torsionally rigid, cantilevered beams were studied. The governing coupled equations of flap lag extensional motion are derived including the effects of large precone and retaining geometric nonlinearities up to second degree. The Galerkin method, with nonrotating normal modes, is used for the solution of both steady state nonlinear equations and linear perturbation equations. Parametric indicating the individual and collective effects of pretwist, precone, Coriolis forces and second degree geometric nonlinearities on the steady state deflection, natural frequencies and mode shapes of rotating blades are presented. It is indicated that the second degree geometric nonlinear terms, which vanish for zero precone, can produce frequency changes of engineering significance. Further confirmation of the validity of including those generated by MSC NASTRAN. It is indicated that the linear and nonlinear Coriolis effects must be included in analyzing thick blades. The Coriolis effects are significant on the first flatwise and the first edgewise modes.

Subrahmanyam, K. B.↗