Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Detector Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder

A radiation-hard transponder was developed utilizing submicron/nanotechnology from IBM. The device consumes low power and has a low fabrication cost. This device utilizes a Plug-and-Play concept, and can be integrated into intra-satellite networks, supporting SpaceWire and Gigabit Ethernet I/O. A space-qualified, 100-pin package also was developed, allowing space-qualified (class K) transponders to be delivered within a six-month time frame. The novel, optical, radiation-tolerant transponder was implemented as a standalone board, containing the transponder ASIC (application specific integrated circuit) and optical module, with an FPGA (field-programmable gate array) friendly parallel interface. It features improved radiation tolerance; high-data-rate, low-power consumption; and advanced functionality. The transponder utilizes a patented current mode logic library of radiation-hardened-by-architecture cells. The transponder was developed, fabricated, and radhard tested up to 1 MRad. It was fabricated using 90-nm CMOS (complementary metal oxide semiconductor) 9 SF process from IBM, and incorporates full BIT circuitry, allowing a loop back test. The low-speed parallel LVCMOS (lowvoltage complementary metal oxide semiconductor) bus is compatible with Actel FPGA. The output LVDS (low-voltage differential signaling) interface operates up to 1.5 Gb/s. Built-in CDR (clock-data recovery) circuitry provides robust synchronization and incorporates two alarm signals such as synch loss and signal loss. The ultra-linear peak detector scheme allows on-line control of the amplitude of the input signal. Power consumption is less than 300 mW. The developed transponder with a 1.25 Gb/s serial data rate incorporates a 10-to-1 serializer with an internal clock multiplication unit and a 10-1 deserializer with internal clock and data recovery block, which can operate with 8B10B encoded signals. Three loop-back test modes are provided to facilitate the built-in-test functionality. The design is based on a proprietary library of differential current switching logic cells implemented in the standard 90-nm CMOS 9SF technology from IBM. The proprietary low-power LVDS physical interface is fully compatible with the SpaceWire standard, and can be directly connected to the SFP MSA (small form factor pluggable Multiple Source Agreement) optical transponder. The low-speed parallel interfaces are fully compatible with the standard 1.8 V CMOS input/output devices. The utilized proprietary annular CMOS layout structures provide TID tolerance above 1.2 MRad. The complete chip consumes less than 150 mW of power from a single 1.8-V positive supply source.

Katzman, Vladimir↗

The Fiber Optic System for the Advanced Topographic Laser Altimeter System (ATLAS) Instrument

The Advanced Topographic Laser Altimeter System (ATLAS) Instrument has been in integration and testing over the past 18 months in preparation for the Ice, Cloud and Land Elevation Satellite - 2 (ICESat-2) Mission, scheduled to launch in 2017. ICESat-2 is the follow on to ICESat which launched in 2003 and operated until 2009. ATLAS will measure the elevation of ice sheets, glaciers and sea ice or the "cryosphere" (as well as terrain) to provide data for assessing the earth's global climate changes. Where ICESat's instrument, the Geo-Science Laser Altimeter (GLAS) used a single beam measured with a 70 m spot on the ground and a distance between spots of 170 m, ATLAS will measure a spot size of 10 m with a spacing of 70 cm using six beams to measure terrain height changes as small as 4 mm. The ATLAS pulsed transmission system consists of two lasers operating at 532 nm with transmitter optics for beam steering, a diffractive optical element that splits the signal into 6 separate beams, receivers for start pulse detection and a wavelength tracking system. The optical receiver telescope system consists of optics that focus all six beams into optical fibers that feed a filter system that transmits the signal via fiber assemblies to the detectors. Also included on the instrument is a system that calibrates the alignment of the transmitted pulses to the receiver optics for precise signal capture. The larger electro optical subsystems for transmission, calibration, and signal receive, stay aligned and transmitting sufficiently due to the optical fiber system that links them together. The robust design of the fiber optic system, consisting of a variety of multi fiber arrays and simplex assemblies with multiple fiber core sizes and types, will enable the system to maintain consistent critical alignments for the entire life of the mission. Some of the development approaches used to meet the challenging optical system requirements for ATLAS are discussed here.

global climate changes↗

Development of the Active Correlation Method: Theoretical-Methodological Aspect

The Dubna Gas-Filled Recoil Separator (DGFRS) of the Flerov Laboratory of Nuclear Reactions (FLNR), JINR, is the most advanced facility for the synthesis and study of new superheavy nuclei. In the recent years, new elements with Z = 114 to 118 (Fl, Mc, Lv, Ts, Og) have been successfully synthesized. The DGFRS detection system and a unique method of active correlations for background suppression have played a significant role in these discoveries. Theoretical-methodological aspects of further development of the active correlation method are considered, especially in view of the upcoming commissioning of the new FLNR high-intensity DC-280 cyclotron for acceleration of heavy ions and the new gas-filled recoil separator. A numerical model of the edge effects between the neighboring strips on the p – n junction side of the DSSSD detector is presented. The corresponding empirical examples are given. A more flexible real-time algorithm is considered as a possible substitute for the current version with the rigidly set parameters. Since stability of the calibration parameters is strongly required for applying the method, the radiation stability factor is also briefly considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

Advanced CID array multispectral pushbroom scanner

An optical imager, called the Scanning Imaging Spectroradiometer (SIS), was built for NASA in the early 1970's. Later, the Solidstate Array Spectroradiometer (SAS) was developed on the basis on a substitution of a Charge Injection Device (CID) array for the vidicon of the SIS. The Advanced Solidstate Array Spectroradiometer (ASAS) represents an improvement of the SAS. ASAS is a solidstate multispectral optical imaging radiometer which is currently the most versatile instrument of its type in the visible part of the spectrum. The instrument is capable of absolute radiometric measurements in all of its 32 bands. ASAS can be easily mounted in small aircraft as well as high altitude craft such as the U-2, taking into account also the possibility of a use in the Space Shuttle. The instrument consists of three separate subsystems. Attention is given to the optics, the detector array, data storage, data retrieval, and system performance.

Stewart, S. E.↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Scintilla European project, the successful research results

The Scintilla FP7 project is ended in December 2014, the fruitful results of 3 years development and tests will be presented. SCINTILLA offers the capacity to finding a reliable alternative to Helium-3 based detection systems since the gas which is predominantly used in nuclear safeguards and security applications has now become very expensive, rare and nearly unavailable. SCINTILLA benchmarks results are based on international standards. Radiation Portal tests were carried out at the Joint Research Centre (JRC) in Ispra (Italy). The scintilla project addresses few mains issues. The first is to develop neutron detectors for Radiation Portal Monitor (RPM) and the second is the need of new wearable integrated solutions for Spectrometric Personal Radiation Monitor (SPRM). The partners which provide technical systems of the scintilla project are INFN-ANSALDO, CEA, SYMETRICA and SAPHYMO. For RPM, the objective is to find reliable alternatives to Helium-3 historical neutron detector and provide technical solutions which cope with tests for reliable mobile and cost effective. For Spectrometric Personal Radiation Monitor (SPRM), SCINTILLA is innovating in technology areas that offer complementary capabilities for detecting and identifying gamma, Two CZT (Cadmium Zinc Telluride) addressing contexts of used by first responder technologies, one is a wearable detector and the second is a gamma camera complemented by advanced image processing technologies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Modeling to Support the TREAT Hodoscope System for Fuel Motion Monitoring

Fuel motion is monitored in real time at the Transient Reactor Test Facility (TREAT) using a direct-viewing hodoscope that monitors fast neutrons emitted from test fuel undergoing fission during transients. The hodoscope system is now being refurbished, after over twenty years, to once again support research and development activities examining the survival and failure modes of advanced nuclear reactor fuel systems under accident conditions. An im-portant part of this activity is the development of high-fidelity modeling tools to predict the hodoscope's response to different fuel systems, in different test vehicles, throughout different transient cycles. Initial work has involved the collection of archival data related to how the hodoscope currently at TREAT was manufactured and installed, and the use of this data to create a preliminary radiation transport model using MCNP6. This model is now undergoing refinement to improve its fidelity and to permit its integration with other tools under development to model TREAT transients. The model will be used to study how fast-neutrons measured in the hodoscope's detectors relate to the fission of nuclear material in a test vehicle as a function of location within the vehicle and reactor power. The goal is to develop a time-dependent coupling factor that will relate the measured data to the fuel mass present within each pixel of the hodoscope's field of view. This paper will present the current status of the TREAT hodoscope refurbishment program and modeling activities related to interpreting hodoscope data and inferring fuel motion during transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Neutron List Mode Collar (LMCL) and a List Mode Response Matrix Analysis Concept

This report was prepared for the Safeguards Program of the US Department of Energy’s (DOE’s) National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The report presents the development of the neutron nondestructive assay system, the List Mode Collar (LMCL) for the project OR16-List Mode for Collar-PD1La “List Mode Response Matrix for Advanced Correlated Neutron Analysis for Nuclear Safeguards.” The new list mode electronics developed under this project, and a spatial analysis concept called the List Mode Response Matrix are also described in this report. Analysis algorithms based on classification methods are published in a separate report. This research addresses the need to expand the capabilities of current nondestructive assay systems used for nuclear safeguards applications and considers the sustainability of safeguards technologies by the development of a “retrofit” concept using electronics based on modern standards. Furthermore, employing list mode data acquisition enabled the development of a spatial analysis concept and empirical measurement of a spatial response not previously used for safeguards neutron counting applications or measured in a traditional neutron collar detector and, therefore, provides new capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commission < 5 µm spatial resolution x-ray imager for High Resolution Turbulence experiments

This report presents the successful development, commissioning, and deployment of the Scintillation-Based X-ray Imager (SBXI) for the High-Resolution Turbulence (HRT) campaign at the National Ignition Facility (NIF). The SBXI system was designed to overcome the spatial resolution and efficiency limitations of conventional x-ray imaging detectors. Through careful system engineering, rigorous laboratory characterization, and experimental validation at NIF, the SBXI has demonstrated spatial resolution at the object plane of 5 μm (±0.5 μm) and a detective quantum efficiency (DQE) of 34% at 7.2 keV, both of which surpass the requirements set by the campaign, and meeting the L2 milestone. The system’s deployment enables high-fidelity imaging of fine-scale hydrodynamic instabilities, directly supporting advanced turbulence model validation and future high energy density physics research.

42 ENGINEERING↗

Support for Advanced Fuel Fabrication MC&A Approaches

This report summarizes the key activities of the Material Protection, Accounting, and Control Technologies (MPACT) program’s safeguards training work package for FY25. The work focused on two main areas: domestic safeguards training and the development of new technologies for nuclear material accounting and control (NMAC). A key development during this FY was the delivery of NMAC statistics for US Nuclear Regulatory Commission requirements refresher course. The course objective was to assist industry in meeting the MC&A program requirements for fuel cycle facilities; this training focused on front-end bulk fuel cycle processes. At the same time, a report was prepared on the research output of an effort that focused on the benefits of commercial fuel debundling for NMAC and waste management. The MPACT team evaluated various technologies and proposed a fuel debundling detector that integrates gamma spectroscopy and neutron detection as the most practical solution. The scope of activities under this work package for FY26 focuses on developing a fundamental nuclear material control plan, also known as MC&A plan, for tristructural isotropic (TRISO) fuel fabrication facilities. This plan will address the various NMAC requirements for facilities that handle Category II.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods for Precision Studies of Neutrino Interactions

Accelerator neutrino oscillation experiments provide a sensitive way to investigatea number of major open questions in neutrino physics. To achieve precision neutrinooscillation measurements, we need a good understanding of key aspects of the experiments,such as the detection technologies used and neutrino interactions at few-GeV energies.The MicroBooNE experiment has advanced the development of technologies for LArTPCs.An ultra-violet laser system was introduced to MicroBooNE in order to measure theelectric field in situ, which plays a central role in the formation of charge and lightsignals in LArTPCs. This thesis describes the setup and operation of the laser system. Ideveloped a general methodology to measure the electric field and the consequent spatialdistortion in LArTPCs, which supports precision measurements in accelerator neutrinooscillation experiments. In MicroBooNE, the measured electric field distortions are upto 15 ± 3 % with respect to the nominal value, and the measured spatial distortions areup to 15 ± 3 cm. The result of the electric field measurement is applied to the detectorsimulation and the event reconstruction, which leads to a better detector characterizationfor neutrino analyses. A significant concern for measurements of neutrino interactions ismodel dependence, as the currently available models are not sufficient for describing thepicture of neutrino interacting at few-GeV energies. In this thesis, I developed a detailedstrategy for a model-independent cross-section measurement at low energy transfers,where the available model predictions do not agree with the inclusive measurementsfrom multiple experiments. A likelihood fit technique for cross-section extraction isrealized in an accelerator neutrino experiment using a LArTPC for the first time. Thetreatment of systematic uncertainties developed in this thesis is generally applicable foranalyses using similar fitting techniques. This neutrino interaction study at low energytransfers provides a probe to the poorly understood region of neutrino cross sections. Themeasurement scheme developed here aims to guide future model-independent cross-sectionmeasurements, particularly for neutrino experiments using LArTPCs.

Chen, Yifan↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗

Reconfigurable Terahertz Metasurface Pure Phase Holograms

Terahertz (THz) radiation has many potential applications. However, comparing with the rapid development of THz sources and detectors, functional devices for THz modulation, especially the spatial modulation devices, are still insufficient. Here, we present a novel approach for generating arbitrary wavefronts of a THz beam is presented. By dynamically creating metasurface structures through illuminating a thin silicon wafer with femtosecond laser, which is spatially modulated, an array of reconfigurable subwavelength resonators is generated. The wavefront of the THz beam is then determined by forming spatial profiles of the Pancharatnam–Berry scattering phase by dynamically controlling the resonator orientation. Proof-of-concept experiments demonstrate that streaming holographic images and lenses of variable focal length can be realized in real time. The reconfigurable scheme demonstrated here is convenient and fast, and may lead to advances in a host of THz applications.

36 MATERIALS SCIENCE↗

SU-F-P-56: On a New Approach to Reconstruct the Patient Dose From Phantom Measurements

Purpose: The development of complex radiation treatment schemes emphasizes the need for advanced QA analysis methods to ensure patient safety. One such tool is the Delta4 DVH Anatomy software, where the patient dose is reconstructed from phantom measurements. Deviations in the measured dose are transferred to the patient anatomy and their clinical impact is evaluated in situ. Results from the original algorithm revealed weaknesses that may introduce artefacts in the reconstructed dose. These can lead to false negatives or obscure the effects of minor dose deviations from delivery failures. Here, we will present results from a new patient dose reconstruction algorithm. Methods: The main steps of the new algorithm are: (1) the dose delivered to a phantom is measured in a number of detector positions. (2) The measured dose is compared to an internally calculated dose distribution evaluated in said positions. The so-obtained dose difference is (3) used to calculate an energy fluence difference. This entity is (4) used as input to a patient dose correction calculation routine. Finally, the patient dose is reconstructed by adding said patient dose correction to the planned patient dose. The internal dose calculation in step (2) and (4) is based on the Pencil Beam algorithm. Results: The new patient dose reconstruction algorithm have been tested on a number of patients and the standard metrics dose deviation (DDev), distance-to-agreement (DTA) and Gamma index are improved when compared to the original algorithm. In a certain case the Gamma index (3%/3mm) increases from 72.9% to 96.6%. Conclusion: The patient dose reconstruction algorithm is improved. This leads to a reduction in non-physical artefacts in the reconstructed patient dose. As a consequence, the possibility to detect deviations in the dose that is delivered to the patient is improved. An increase in Gamma index for the PTV can be seen. The corresponding author is an employee of ScandiDos.

60 APPLIED LIFE SCIENCES↗

Status Report for Development of Advanced Process Monitoring Concepts for IAEA Safeguards Sponsored by the Next Generation Safeguards Initiative (NGSI)

Process monitoring (PM) is used in international safeguards as an additional measure to nuclear material accountancy (NMA). For large throughput nuclear facilities such as commercial spent fuel reprocessing plants, it is difficult to satisfy the lAEA's goal for detection probability using NMA alone. And, for an facilities, regardless of their throughput, PM can provide redundant verification for both NMA and containment and surveillance and can be used to detect abnormal plant operation through the use of IAEA's instrumentation and selected operator's process control instrumentation. Examples of PM include (1) continuity of knowledge of nuclear material flows and inventories by monitoring of tank solution levels in reprocessing plants, (2) load cell monitoring of cylinders in GCEPs, (3) thermal power monitoring of large research reactors to detect undeclared operation, and (4) providing data to enable frequent NMA-like evaluation (near-real-time-accounting), which involves a hybrid of NMA and PM, for many facility types. Sensors required for PM include for example sensors for measuring flow, volume, density, level, temperature, and other diverse sensors such as portal monitors, video cameras, motion detectors, and gamma and neutron detectors. Additionally, PM lends itself to remote and/or unattended monitoring which has the potential to reduce the IAEA inspection burden and intrusiveness to the operator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗