Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

An Overview of Policies Influencing Air Pollution from the Electricity Sector in Central Asia

The electricity sector is a substantial source of air pollution and associated health problems in Central Asia and elsewhere. Fossil-fueled power plants emit a wide variety of harmful pollutants and their chemical precursors. The pollutants with the greatest health impacts are particulate matter and ozone. Once released into the atmosphere, there is no practical way to remove air pollutants, which means that policies designed to improve air quality have to limit the pollutants before release. However, tackling such pollution is challenging, particularly in developing economies, due to the need to provide electricity as a basic necessity for citizens and as an engine of economic growth. This report provides examples of policies impacting air pollution from the electricity sector in the Central Asian countries of Kazakhstan, Kyrgyzstan, Tajikistan, Turkmenistan, and Uzbekistan. It is a partner publication to an earlier report that addressed policies in South Asia. As with the South Asia report, information on policies in some countries was difficult to locate; therefore, this is not a comprehensive study, but rather an overview or "scan" of the sector that includes examples of: (1) policies that directly regulate air quality by limiting emissions from specific point sources (by restricting operating hours, for instance); and (2) indirect policies that incentivize or disincentivize polluting activities, such as policies to encourage fuel switching to or from cleaner renewable resources. Note that this report was prepared before the Russia-Ukraine conflict and therefore doesn't address consequences of that war for Central Asia. The report finds: (1) That Central Asian countries typically have relatively few policy instruments available for regulating national air emissions; (2) That many countries, especially those that have a mismatch between seasonal demand and resource availability, could improve energy security and reduce air pollution through increased cross-border electricity trade; (3) That some countries have seemingly contradictory policies (promoting both coal and renewables, for instance). This report is also available in Russian: https://www.nrel.gov/docs/fy23osti/85192.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Air Dispersion Modeling for Building 3026C/D Demolition

This report presents estimates of dispersion coefficients and effective dose for potential air dispersion scenarios of uncontrolled releases from Oak Ridge National Laboratory (ORNL) buildings 3026C, 3026D, and 3140 prior to or during the demolition of the 3026 Complex. The Environmental Protection Agency (EPA) AERMOD system1-6 was used to compute these estimates. AERMOD stands for AERMIC Model, where AERMIC is the American Meteorological Society-EPA Regulatory Model Improvement Committee. Five source locations (three in building 3026D and one each in building 3026C and the filter house 3140) and associated source characteristics were determined with the customer. In addition, the area of study was determined and building footprints and intake locations of air-handling systems were obtained. In addition to the air intakes, receptor sites consisting of ground level locations on four polar grids (50 m, 100 m, 200 m, and 500 m) and two intersecting lines of points (50 m separation), corresponding to sidewalks along Central Avenue and Fifth Street. Three years of meteorological data (2006 2008) were used each consisting of three datasets: 1) National Weather Service data; 2) upper air data for the Knoxville-Oak Ridge area; and 3) local weather data from Tower C (10 m, 30 m and 100 m) on the ORNL reservation. Annual average air concentration, highest 1 h average and highest 3 h average air concentrations were computed using AERMOD for the five source locations for the three years of meteorological data. The highest 1 h average air concentrations were converted to dispersion coefficients to characterize the atmospheric dispersion as the customer was interested in the most significant response and the highest 1 h average data reflects the best time-averaged values available from the AERMOD code. Results are presented in tabular and graphical form. The results for dose were obtained using radionuclide activities for each of the buildings provided by the customer.7 Radiation dose was calculated assuming complete release of the building inventory as information was lacking regarding the portion of the building inventory expected to be released. Thus the results are derived using an extremely conservative release as documented in the Preliminary Hazard Screening report.7 To more closely approximate the result of a release, one must estimate the fraction of the total inventory released and multiply the results described above by that fraction. An example of how this calculation is accomplished is provided. Should an actual uncontrolled release occur, the results of this modeling effort could only be used to establish a rough order-of-magnitude for the event.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fungal colonization of air filters and insulation in a multi-story office building: production of volatile organics

Secondary air filters in the air-handling units on four floors of a multi-story office building with a history of fungal colonization of insulation within the air distribution system were examined for the presence of growing fungi and production of volatile organic compounds. Fungal mycelium and conidia of Cladosporium and Penicillium spp. were observed on insulation from all floors and both sides of the air filters from one floor. Lower concentrations of volatile organics were released from air filter medium colonized with fungi as compared with noncolonized filter medium. However, the volatiles from the colonized filter medium included fungal metabolites such as acetone and a carbonyl sulfide-like compound that were not released from noncolonized filter medium. The growth of fungi in air distribution systems may affect the content of volatile organics in indoor air.

NASA Discipline Environmental Health↗

Urban Air Mobility Traffic Analysis Tool for Airspace Involving Vertiport Hub Operations to Examine Simulated Conflicts

Presented herein are details of the development of an Urban Air Mobility Traffic Analysis Tool (UAM TAT), designed to analyze the traffic of Vertical Take-off and Landing (VTOL) air-craft in urban agglomerations to enable the Urban Air Mobility(UAM) operations. The tool aims to address challenges of UAM operations in a simulated airspace by testing different scenarios and methods for air traffic management. It emphasizes the need for effective risk management practices and methodologies to ensure the safety of operations, given the increasing use of highly automated aircraft (i.e., Advanced Air Mobility (AAM))in urban environments. The tool is modular and allows for the simulation of various families of VTOLs and different air traffic rules, making it suitable for defining and estimating airspace and vertiports capacity, determining VTOL requirements, and testing and comparing air traffic management methods. The results of five different simulations are presented that show the capabilities and functionalities of the tool. The simulations present the impact of vertiport hub operations and various ATM approach on the VTOLs’ conflicts.

Urban Air Mobility↗

Effect of Ambient Design Temperature on Air-Cooled Binary Plant Output

Air-cooled binary plants are designed to provide a specified level of power production at a particular air temperature. Nominally this air temperature is the annual mean or average air temperature for the plant location. This study investigates the effect that changing the design air temperature has on power generation for an air-cooled binary plant producing power from a resource with a declining production fluid temperature and fluctuating ambient temperatures. This analysis was performed for plants operating both with and without a geothermal fluid outlet temperature limit. Aspen Plus process simulation software was used to develop optimal air-cooled binary plant designs for specific ambient temperatures as well as to rate the performance of the plant designs at off-design operating conditions. Results include calculation of annual and plant lifetime power generation as well as evaluation of plant operating characteristics, such as improved power generation capabilities during summer months when electric power prices are at peak levels.

15 GEOTHERMAL ENERGY↗

Analysis on the Density Driven Air-Ingress Accident in VHTRs

Air-ingress following the pipe rupture is considered to be the most serious accident in the VHTRs due to its potential problems such as core heat-up, structural integrity and toxic gas release. Previously, it has been believed that the main air-ingress mechanism of this accident is the molecular diffusion process between the reactor core and the cavity. However, according to some recent studies, there is another fast air-ingress process that has not been considered before. It is called density-driven stratified flow. The potential for density-driven stratified air ingress into the VHTR following a large-break LOCA was first described in the NGNP Methods Technical Program based on stratified flow studies performed with liquid. Studies on densitygradient driven stratified flow in advanced reactor systems has been the subject of active research for well over a decade since density-gradient dominated stratified flow is an inherent characteristic of passive systems used in advanced reactors. Recently, Oh et al. performed a CFD analysis on the stratified flow in the VHTR, and showed that this effect can significantly accelerate the air-ingress process in the VHTRs. They also proposed to replace the original air-ingress scenario based on the molecular diffusion with the one based on the stratified flow. This paper is focusing on the effect of stratified flow on the results of the air-ingress accident in VHTR

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Iron-Decorated Carbon Aerogel for Rechargeable Flow and Flexible Zn–Air Batteries

Mechanically stable and foldable air cathodes with exceptional oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) activities are key components of wearable metal-air batteries. Herein, a directional freeze-casting and annealing approach is reported for the construction of a 3D honeycomb nanostructured, N,P-doped carbon aerogel incorporating in situ grown FeP/Fe 2 O 3 nanoparticles as the cathode in a flexible Zn-air battery (ZAB). The aqueous rechargeable Zn-air batteries assembled with this carbon aerogel exhibit a remarkable specific capacity of 648 mAh g -1 at a current density of 20 mA cm -2 with a good long-term durability, outperforming those assembled with commercial Pt/C+RuO 2 catalyst. Furthermore, such a foldable carbon aerogel with directional channels can serve as a freestanding air cathode for flexible solid-state Zn-air batteries without the use of carbon paper/cloth and additives, giving a specific capacity of 676 mAh g -1 and an energy density of 517 Wh kg -1 at 5 mA cm -2 together with good cycling stability. This work offers a new strategy to design and synthesize highly effective bifunctional air cathodes to be applied in electrochemical energy devices.

25 ENERGY STORAGE↗

Highly Active and Durable Air Electrodes for Reversible Protonic Ceramic Electrochemical Cells Enabled by an Efficient Bifunctional Catalyst

The commercialization of reversible protonic ceramic electrochemical cells is hindered by the lack of highly active and durable air electrodes exposed to high concentration of steam under operating conditions. We report findings that dramatically enhance the electrocatalytic activity and stability of a conventional (La 0.6 Sr 0.4 ) 0.95 Co 0.2 Fe 0.8 O 3-δ (LSCF) air electrode by a multiphase catalyst coating composed of a conformal Pr 1-x Ba x CoO 3-δ thin film and exsolved BaCoO 3-δ nanoparticles, are reported. At 600 °C, the catalyst coating decreases the polarization resistance of the LSCF air electrode by a factor of 25 (from 1.09 to 0.043 Ω cm 2 ) in air and the degradation rate by two orders of magnitude (from 1.0 × 10 -2 to 1.8 × 10 -4 Ω cm2 h -1 in humidified air with 30 vol% H2O). Further, a single cell with the catalyst-coated LSCF air electrode at 600 °C demonstrates a high peak power density of 1.04 W cm -2 in the fuel cell mode and a high current density of 1.82 A cm -2 at 1.3 V in the electrolysis mode. The significantly enhanced performance of the LSCF air electrode is attributed mainly to the high rate of surface oxygen exchange, fast surface proton diffusion, and the rapid H 2 O and O 2 dissociation on the catalysts.

36 MATERIALS SCIENCE↗

Comparison of Short-Term Oxidation Behavior of Model and Commercial Chromia-Forming Ferritic Stainless Steels in Air with Water Vapor

A high-purity Fe-20Cr and commercial type 430 ferritic stainless steel were exposed at 700 and 800 C in dry air and air with 10% water vapor (wet air) and characterized by SEM, XRD, STEM, SIMS, and EPMA. The Fe-20Cr alloy formed a fast growing Fe-rich oxide scale at 700 C in wet air after 24 h exposure, but formed a thin chromia scale at 700 C in dry air and at 800 C in both dry air and wet air. In contrast, thin spinel + chromia base scales with a discontinuous silica subscale were formed on 430 stainless steel under all conditions studied. Extensive void formation was observed at the alloy-oxide interface for the Fe-20Cr in both dry and wet conditions, but not for the 430 stainless steel. The Fe-20Cr alloy was found to exhibit a greater relative extent of subsurface Cr depletion than the 430 stainless steel, despite the former's higher Cr content. Depletion of Cr in the Fe-20Cr after 24 h exposure was also greater at 700 C than 800 C. The relative differences in oxidation behavior are discussed in terms of the coarse alloy grain size of the high-purity Fe-20Cr material, and the effects of Mn, Si, and C on the oxide scale formed on the 430 stainless steel.

08 HYDROGEN↗

An accurate bilinear cavern model for compressed air energy storage

Compressed air energy storage is suitable for large-scale electrical energy storage, which is important for integrating renewable energy sources into electric power systems. A typical compressed air energy storage plant consists of compressors, expanders, caverns, and a motor/generator set. Current cavern models used for compressed air energy storage are either accurate but highly nonlinear or linear but inaccurate. The application of highly nonlinear cavern models in power system optimization problems renders them computationally challenging to solve. In this regard, an accurate bilinear cavern model for compressed air energy storage is proposed. The charging and discharging processes in a cavern are divided into several real/virtual states. The first law of thermodynamics and ideal gas law are then utilized to derive a cavern model, i.e., a model for the variation of temperature and pressure in these processes. Thereafter, the heat transfer between the air in the cavern and the cavern wall is considered and integrated into the cavern model. By subsequently eliminating several negligible terms, the cavern model reduces to a bilinear model. The accuracy of the bilinear cavern model is verified via comparison with both an accurate nonlinear model and two sets of field-measured data. The bilinear cavern model can be easily linearized and is then suitable for integration into optimization problems considering compressed air energy storage. This is verified via comparatively solving a self-scheduling problem of compressed air energy storage using different cavern models.

25 ENERGY STORAGE↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geographic and social disparities in exposure to air neurotoxicants at U.S. public schools

Highlights: • Ambient neurotoxicants pose serious risks at US public schools. • There are social and spatial disparities in ambient neurotoxicant risks. • One-third of all schools in EPA Region 2 are at “high risk” for neurotoxicant exposure. • Schools with higher % of Hispanic, black, and Asian students face disparate risks. • Schools serving the youngest (vs. older) students face disparate risks. Children are especially vulnerable to the health and developmental impacts of environmental hazards and they spend significant portions of their days at school. Yet there are no national-level studies examining school-level environmental inequalities and few have examined disparate exposure to neurological air toxicants, even though chronic exposure to air pollution impacts children's brain functioning. We paired information about the geographic locations and demographics of each public school in the US with air neurotoxicant exposure estimates pertaining to 24 known neurotoxicants included in the US Environmental Protection Agency's National Air Toxics Assessment. Using bivariate and multivariate statistics, we tested for environmental injustices in air neurotoxicant exposure at 84,969 US public schools. Metropolitan New York City (EPA Region 2) is the geographic region most burdened by air neurotoxicant exposures at schools since one-third of all schools in that region are in the top 10% (at {sup h}igh risk{sup )} for ambient neurotoxicant exposure among all schools nationwide. Students attending “high risk” public schools nationwide are significantly more likely to be eligible for free/reduced price meals, and to be Hispanic, black, or Asian/Pacific Islander (API). They are significantly less likely to be white or of another race. In a multivariate generalized estimating equation controlling for school district effects, schools with greater proportions of Hispanic, black, and API students, schools with higher enrollment, and schools located in more urban (vs. rural) counties face greater risks. Schools serving the youngest students (e.g., pre-kindergarten) have greater levels of risk than schools serving older students. Across all analyses, this study shows that racial/ethnic minority children are bearing the brunt of air neurotoxicant exposures at school, which may be unequally impacting their school performance and future potential.

54 ENVIRONMENTAL SCIENCES↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A novel transient infrared imaging method for non-intrusive, low-cost, fast, and accurate air leakage detection in building envelopes

Air leakage through the building envelope in the U.S. accounts for about four quads of energy annually, costing approximately $40 billion per year. However, a high-fidelity and non-intrusive method to detect air leakage has not been demonstrated to date. Here, in this paper, we propose a novel non-intrusive and low-cost method called Transient Infrared (IR) Imaging (TIRI) that can rapidly and accurately identify air leakage locations and relative rates on building envelopes. When the interior and exterior temperatures are different, and a small internal pressure pulse is created by HVAC, the temperature at locations with air leakages will change rapidly, while the areas without a leakage do not change. Based on a heat transfer model, we have derived the temperature change as a function of time after the HVAC is turned on. By tracking the temperature change, which depends on leakage rate and size, we have obtained the air leakage map in the case studies. Using an exterior door as an example, we took transient IR images in different seasons and different times of the day, and successfully obtained the leakage map in all the scenarios. Successfully obtained the air leakage map even when the indoor-outdoor air temperature difference is as small as 2 °C. We have also realized a detection speed of 10s and demonstrated that this method also worked for windows, which have mirror-like IR reflections. Our TIRI method will accelerate the improvement of airtightness in buildings, save building energy, and help reduce greenhouse gas emissions.

42 ENGINEERING↗

Humidity’s impact on greenhouse gas emissions from air conditioning

We report that the increasing need to cool the air in our built environment is both a cause and an effect of climate change. Air conditioning accounts for a large portion of global greenhouse gas emissions today, which we estimate at 3.9%; however, the role that humidity plays in these emissions is often overlooked. Here, we show that the emissions associated with reducing air humidity (i.e., removing water vapor from air) are larger than emissions associated with reducing air temperature (i.e., cooling air). We calculate these emissions for today and 2050 and show how dramatically humidity-related emissions will increase with rising cooling demand around the world. We also calculate the minimum separation energy for removing water vapor from air and find that this is at least an order of magnitude less than the processes used today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Persistent activation of DNA damage signaling in response to complex mixtures of PAHs in air particulate matter

Complex mixtures of polycyclic aromatic hydrocarbons (PAHs) are present in air particulate matter (PM) and have been associated with many adverse human health effects including cancer and respiratory disease. However, due to their complexity, the risk of exposure to mixtures is difficult to estimate. In the present study the effects of binary mixtures of benzo[a]pyrene (BP) and dibenzo[a,l]pyrene (DBP) and complex mixtures of PAHs in urban air PM extracts on DNA damage signaling was investigated. Applying a statistical model to the data we observed a more than additive response for binary mixtures of BP and DBP on activation of DNA damage signaling. Persistent activation of checkpoint kinase 1 (Chk1) was observed at significantly lower BP equivalent concentrations in air PM extracts than BP alone. Activation of DNA damage signaling was also more persistent in air PM fractions containing PAHs with more than four aromatic rings suggesting larger PAHs contribute a greater risk to human health. Altogether our data suggests that human health risk assessment based on additivity such as toxicity equivalency factor scales may significantly underestimate the risk of exposure to complex mixtures of PAHs. The data confirms our previous findings with PAH-contaminated soil (Niziolek-Kierecka et al., 2012) and suggests a possible role for Chk1 Ser317 phosphorylation as a biological marker for future analyses of complex mixtures of PAHs. -- Highlights: ► Benzo[a]pyrene (BP), dibenzo[a,l]pyrene (DBP) and air PM PAH extracts were compared. ► Binary mixture of BP and DBP induced a more than additive DNA damage response. ► Air PM PAH extracts were more potent than toxicity equivalency factor estimates. ► Larger PAHs (> 4 rings) contribute more to the genotoxicity of PAHs in air PM. ► Chk1 is a sensitive marker for persistent activation of DNA damage signaling from PAH mixtures.

60 APPLIED LIFE SCIENCES↗

Measurement of gas species, temperatures, coal burnout, and wall heat fluxes in a 200 MWe lignite-fired boiler with different overfire air damper openings

Measurements were performed on a 200 MWe, wall-fired, lignite utility boiler. For different overfire air (OFA) damper openings, the gas temperature, gas species concentration, coal burnout, release rates of components (C, H, and N), furnace temperature, and heat flux and boiler efficiency were measured. Cold air experiments for a single burner were conducted in the laboratory. The double-swirl flow pulverized-coal burner has two ring recirculation zones starting in the secondary air region in the burner. As the secondary air flow increases, the axial velocity of air flow increases, the maxima of radial velocity, tangential velocity and turbulence intensity all increase, and the swirl intensity of air flow and the size of recirculation zones increase slightly. In the central region of the burner, as the OFA damper opening widens, the gas temperature and CO concentration increase, while the O{sub 2} concentration, NOx concentration, coal burnout, and release rates of components (C, H, and N) decrease, and coal particles ignite earlier. In the secondary air region of the burner, the O{sub 2} concentration, NOx concentration, coal burnout, and release rates of components (C, H, and N) decrease, and the gas temperature and CO concentration vary slightly. In the sidewall region, the gas temperature, O{sub 2} concentration, and NOx concentration decrease, while the CO concentration increases and the gas temperature varies slightly. The furnace temperature and heat flux in the main burning region decrease appreciably, but increase slightly in the burnout region. The NOx emission decreases from 1203.6 mg/m{sup 3} (6% O{sub 2}) for a damper opening of 0% to 511.7 mg/m{sup 3} (6% O{sub 2}) for a damper opening of 80% and the boiler efficiency decreases from 92.59 to 91.9%. 15 refs., 17 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗