Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 847 records · Page 47

Properties of Sb{sub 2}S{sub 3} and Sb{sub 2}Se{sub 3} thin films obtained by pulsed laser ablation

The properties of Sb{sub 2}S{sub 3} and Sb{sub 2}Se{sub 3} thin films of variable thickness deposited onto Al{sub 2}O{sub 3}, Si, and KCl substrates are investigated by the method of pulsed laser ablation. The samples are obtained at a substrate temperature of 180 Degree-Sign C in a vacuum chamber with a residual pressure of 10{sup -5} Torr. The thickness of the films amounted to 40-1500 nm. The structure of the bulk material of the targets and films is investigated by the methods of X-ray diffraction and transmission high-energy electron diffraction, respectively. The electrical properties of the films are investigated in the temperature range of 253-310 K. It is shown that the films have semiconductor properties. The structural features of the films determine their optical parameters.

36 MATERIALS SCIENCE↗

Time-of-Flight Characteristics of a Laser Torch during Ablation of a MnSi Target in Argon Atmosphere

The Langmuir-probe technique has been used to study the time-of-flight characteristics of a laser torch during MnSi-target ablation in vacuum and argon atmosphere by pulsed 532-nm laser radiation at 15-ns pulse duration. It is established that the amplitude of the signal of fast particles in the laser torch nonmonotonically depends on the buffer-gas pressure. Mechanisms determining this dependence of laser-torch characteristics on the pressure are considered. The influence of buffer-gas pressure on the ion-velocity distribution function is determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Effect of Boron on the Structure and Conductivity of Thin Films Obtained by Laser Ablation of Diamond with Deposition at 700°C

Structural features of CB{sub x} films obtained by pulsed laser ablation of targets made of pressed diamond powder with boron-powder additions at B/C atomic ratio of x = 0.33 have been studied. The films were deposited on heated substrates, so that diffusion processes involving C and B atoms on the surface and in the volume of films were possible. Selected conditions of film deposition ensured their effective doping with boron (0.4 ≤ x ≤ 0.6). The incorporation of B atoms was accompanied by the formation of B–C chemical bonds, whereas the formation of sp{sup 2} graphite bonds and their ordering in clusters with laminar packing was suppressed. The films possessed very low resistivity (~1.4 mΩ cm) at room temperature and exhibited metallic type of conductance on decreasing the temperature to 77 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction to: Phase 2 Open-Label Trial Investigating Percutaneous Laser Ablation for Treatment of Early-Stage Breast Cancer: MRI, Pathology, and Outcome Correlations

The article “Phase 2 Open-Label Trial Investigating Percutaneous Laser Ablation for Treatment of Early-Stage Breast Cancer: MRI, Pathology, and Outcome Correlations”, written by Barbara Schwartzberg et al., was originally published electronically on the publisher’s internet portal (currently SpringerLink) on July 9, 2018, without open access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multielemental analysis of prehistoric animal teeth by laser-induced breakdown spectroscopy and laser ablation inductively coupled plasma mass spectrometry

Laser-induced breakdown spectroscopy (LIBS) and laser ablation (LA) inductively coupled plasma (ICP) mass spectrometry (MS) were utilized for microspatial analyses of a prehistoric bear (Ursus arctos) tooth dentine. The distribution of selected trace elements (Sr, Ba, Fe) was measured on a 26 mmx15 mm large and 3 mm thick transverse cross section of a canine tooth. The Na and Mg content together with the distribution of matrix elements (Ca, P) was also monitored within this area. The depth of the LIBS craters was measured with an optical profilometer. As shown, both LIBS and LA-ICP-MS can be successfully used for the fast, spatially resolved analysis of prehistoric teeth samples. In addition to microchemical analysis, the sample hardness was calculated using LIBS plasma ionic-to-atomic line intensity ratios of Mg (or Ca). To validate the sample hardness calculations, the hardness was also measured with a Vickers microhardness tester.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Resolution Spectroscopy of Laser Ablation Plumes Using Laser-Induced Fluorescence

We used a CW laser as a narrow-band (~50kHz) tunable LIF excitation source to probe absorption from selected atomic transitions (Al, U etc. ) in a ns laser ablation plume. A comparison of fluorescence signal with respect to emission spectroscopy show significant increase in the magnitude and persistence from selected Al and U transitions in a LIBS plume. The high spectral resolution provided by the LIF measurement allows peaks to be easily separated even if they overlap in the emission spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth of Epitaxial ZnS Films by Pulsed-Laser Ablation

Pulsed KrF (248nm) laser ablation of a polycrystailine ZnS target has been used to grow high quality, carbon-free, epitaxial ZnS thin films on GaAs(OOl), GaAs(111), and GaP(OOl). The films were grown at temperatures of 150-450°C, using a rotating substrate heater and deposition geometry that produces films with highly uniform thickness. X-ray rocking curves are consistent with (111) stacking faults being the dominant defects in the ZnS films grown on GaAs. The estimated stacking fault density is ~6 × 10 10 cm −3 , comparable to the best MOCVD ZnS films. RBS analysis shows that these defects are located predominantly near the GaAs-ZnS interface. The anisotropy of the ZnS growth rate, between the GaAs(001) and GaAs(111) surfaces, was found to be temperature-dependent.

36 MATERIALS SCIENCE↗

Comparison of femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements

Feasibility tests were conducted using femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for rapid uranium isotopic measurements. The samples used in this study consisted of a range of pg quantities of known 235/238 U solutions as dried spot residues of 300 pL drops on silicon substrates. The samples spanned the following enrichments of 235 U: 0.5, 1.5, 2, 3, and 15.1%. In this direct comparison using these particular samples both pulse durations demonstrated near equivalent data can be produced on either system with respect to accuracy and precision. There is no question that either LA-ICP-MS method offers the potential for rapid, accurate and precise isotopic measurements of U10Mo materials whether DU, LEU or HEU. The LA-ICP-MS equipment used for this work is commercially available. The program is in the process of validating this work for large samples using center samples strips from Y-12 MP-1 LEU-Mo Casting #1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

This report describes the installation, testing, and acceptance of the Waste Treatment and Immobilization Plant (WTP) procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste (HLW) samples in a hot cell environment. The work was completed by the Analytical Process Development (APD) group in accordance with Task Order 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S Laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LASER ABLATION-INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROSCOPY STUDY AT THE 222-S LABORATORY USING HOT-CELL GLOVE BOX PROTOTYPE SYSTEM

This report describes the installation, testing and acceptance of the Waste Treatment and Immobilization Plant procured laser ablation-inductively coupled plasma-atomic emission spectroscopy (LA-ICP-AES) system for remotely analyzing high-level waste samples in a hot cell environment. The 2005-003; ATS MP 1027, Management Plan for Waste Treatment Plant Project Work Performed by Analytical Technical Services. The APD group at the 222-S laboratory demonstrated acceptable turnaround time (TAT) and provide sufficient data to assess sensitivity, accuracy, and precision of the LA-ICP-AES method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of Nano- and Micro-Scale Surface Features Induced by Long-Range Femtosecond Filament Laser Ablation

In this work, we study the characteristics of femtosecond-filament-laser–matter interactions and laser-induced periodic surface structures (LIPSS) at a beam-propagation distance up to 55 m. The quantification of the periodicity of filament-induced self-organized surface structures was accomplished by SEM and AFM measurements combined with the use of discrete two-dimensional fast Fourier transform (2D-FFT) analysis, at different filament propagation distances. The results show that the size of the nano-scale surface features increased with ongoing laser filament processing and, further, periodic ripples started to form in the ablation-spot center after irradiation with five spatially overlapping pulses. The effective number of irradiating filament pulses per spot area affected the developing surface texture, with the period of the low spatial frequency LIPSS reducing notably at a high pulse number. The high regularity of the filament-induced ripples was verified by the demonstration of the angle-of-incidence-dependent diffraction of sunlight. This work underlines the potential of long-range femtosecond filamentation for energy delivery at remote distances, with suppressed diffraction and long depth focus, which can be used in biomimetic laser surface engineering and remote-sensing applications.

36 MATERIALS SCIENCE↗

ABLATION AND CHEMICAL ALTERATION OF COSMIC DUST PARTICLES DURING ENTRY INTO THE EARTH’S ATMOSPHERE

Most dust-sized cosmic particles undergo ablation and chemical alteration during atmospheric entry, which alters their original properties. A comprehensive understanding of this process is essential in order to decipher their pre-entry characteristics. The purpose of the study is to illustrate the process of vaporization of different elements for various entry parameters. The numerical results for particles of various sizes and various zenith angles are treated in order to understand the changes in chemical composition that the particles undergo as they enter the atmosphere. Particles with large sizes (> few hundred μ m) and high entry velocities (>16 km s{sup −1}) experience less time at peak temperatures compared to those that have lower velocities. Model calculations suggest that particles can survive with an entry velocity of 11 km s{sup −1} and zenith angles (ZA) of 30°–90°, which accounts for ∼66% of the region where particles retain their identities. Our results suggest that the changes in chemical composition of MgO, SiO{sub 2}, and FeO are not significant for an entry velocity of 11 km s{sup −1} and sizes <300 μ m, but the changes in these compositions become significant beyond this size, where FeO is lost to a major extent. However, at 16 km s{sup −1} the changes in MgO, SiO{sub 2}, and FeO are very intense, which is also reflected in Mg/Si, Fe/Si, Ca/Si, and Al/Si ratios, even for particles with a size of 100 μ m. Beyond 400 μ m particle sizes at 16 km s{sup −1}, most of the major elements are vaporized, leaving the refractory elements, Al and Ca, suspended in the troposphere.

79 ASTRONOMY AND ASTROPHYSICS↗

A Langmuir Probe Diagnostic for Use in Inhomogeneous, Time-Varying Plasmas Produced by High-Energy Laser Ablation

Langmuir probes (LP) are used extensively to characterize plasma environments produced by radio frequency, pulsed plasma thrusters, and laser ablation. We discuss here the development of a LP diagnostic to examine high-density, high-temperature inhomogeneous plasmas such as those that can be created at the University of Rochester's Laboratory for Laser Energetics OMEGA facility. We have configured our diagnostic to examine the velocity of the plasma expanding from the target. We observe velocities of approximately 16-17 cm/{micro}s, with individual LP currents displaying complex structures, perhaps due to the multiple atomic species and ionization states that exist.

47 OTHER INSTRUMENTATION↗

Excellent antioxidizing, thermally insulating and flame resistance silica‐polybenzoxazine aerogels for aircraft ablative materials

Abstract High‐performance thermal protective composites with lightweight, micro‐ ablation and high‐efficient thermal insulation are urgently required for thermal protection systems in advanced hypersonic speed vehicles. However, the practical applications of thermal protective composites have long been hampered by the main issues such as low mass residual rate and poor long‐term antioxidation of the matrix in high‐temperature aerobic environments. Here, we report a novel silica‐polybenz oxazine (SiO 2 ‐PBO) aerogels with interpenetrated networks, possessing the ability to antioxidation, thermal insulation, and flame‐retardant properties. The resulting SiO 2 ‐PBO aerogels exhibit low density (0.25 g/cm 3 ), low thermal conductivity (0.035 W/(m·K)), and superior peak heat release rate value (15.3 W/g). Moreover, the mass residual rate is up to 70.46 wt% in the N 2 atmosphere and remains 57.83 wt% despite existing in the air atmosphere and experiencing the highest temperature of 800°C. Briefly, SiO 2 ‐PBO aerogels as‐prepared could be a potential matrix for a new gene ration of high‐performance thermal protective composites in the future.

Xiao, Yunyun↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hemobilia after CT-guided radiofrequency ablation of liver tumors: frequency, risk factors, and clinical significance

Purpose: The purpose of the study is to evaluate the frequency, risk factors, and clinical significance of hemobilia after percutaneous computed tomography (CT)-guided radiofrequency ablation (RFA) of liver tumors. Materials and methods: From January 2013 to September 2016, 195 patients received 267 sessions of CT-guided RFA for liver tumors at our institution. The CT images during and immediately after the RFA were retrospectively reviewed. The frequency of hemobilia development and clinical outcome of patients with hemobilia were studied. Risk factors were identified by comparison between the hemobilia and non-hemobilia groups using univariate and multivariate analysis. The clinical courses of patients with hemobilia were also reviewed. Results: The frequency of CT detected hemobilia after RFA was 8.2% (22/267). The majority of the clinical courses were self-limited. Univariate analysis showed that the tumor numbers (p = 0.015), the central type puncture track (p < 0.001), the length of the puncture track (p = 0.033), and the platelet count (p = 0.026) were significantly associated with the development of hemobilia. Multivariate analysis demonstrated that the central type puncture track (p < 0.024) and the platelet count (p = 0.023) were significant independent risk factors. Conclusion: Detection of hemobilia on CT images immediately after percutaneous RFA for liver tumors was not rare. Low platelet count and central type puncture track are independent risk factors. In most cases, hemobilia presented as a minor complication with favorable prognosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗