Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Grid Resilient, Self-Powered, Fuel Flexible, High Efficiency Heating System (Final Report)

The Grid Independent High Efficiency System (GIHES) delivers a heating system that operates free from the power grid and provides ultra-low emissions and high efficiency heating for residential and commercial buildings. The project demonstrated two weeks of continuous grid independent operation of a storage water heater equipped with a powered damper. The Thermoelectric Generator (TEG) integrated GIHES technology revolutionizes heating systems to provide grid resilient hot water production, while delivering significant value to the end user by eliminating impacts of power interruption and enhancing comfort, convenience and productivity. The system maximizes the thermal-to-electric conversion efficiency by optimizing location and orientation of the TEGs and durability while lowering system costs. The TEGs generate enough power to charge a battery and run the storage water heater unit with a powered damper uninterrupted by providing the required parasitic electrical power for start-up, shutdown and during idling. Several TEGs were analytically and experimentally evaluated based on the size, surface area and the power being generated before designing and fabricating a complete multi-TEG assembly for integration with the water heater. The GIHES technology can be extended to boilers, furnaces and tankless water heaters and integrated with heat pump to further increase the overall equipment efficiency. The technology has the potential to reduce the amount of dispatch power and peak power plant operation. An advanced burner was designed, developed and 3D printed for fuel flexible operation. The burner was designed to enable tighter integration with TEGs for potentially higher TEG output, should this be necessary. A bench-scale test rig to perform testing of a 200,000 Btu/h burner and capable of handling up to 10% H2 (by volume) was setup at GTI’s laboratory with appropriate safety and controls to ensure smooth and safe operation. Testing of the 3D burner showed < 5 ppm NOx emissions can be achieved for the entire firing range and with different levels of hydrogen blends with natural gas. The burner will enable a more integrated TEG-burner module design for improved system performance, should this be required in the future. Techno-economic analysis (TEA) of the TEG integrated with the water heaters was performed. The testing data and the power output were used to develop the TEA. The analysis for the storage unit with damper showed that the TEG integrated system costs $95. This is much lower than a one-time charge needed to wire and install dedicated power. Discussions with TEG manufacturers and OEM’s will provide more detailed information and methods to further lower these costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neutrino Interactions observed with Large Area Picosecond Photodetectors in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water-based neutrino detector located at Fermilab, approximately 110 m downstream of the Booster Neutrino Beam (BNB). ANNIE utilizes both photomultiplier tubes (PMTs) and advanced photodetectors, specifically Large Area Picosecond Photodetectors (LAPPDs), to detect Cherenkov light emitted by leptons produced in neutrino interactions within ANNIE. LAPPDs are a novel technology designed to detect photons with picosecond-level temporal resolution and sub-millimetre spatial precision. Multiple LAPPDs have been deployed in the ANNIE detector. This is the first use of this technology in a running particle physics experiment and has yielded the first detection of light from neutrino interactions in water with LAPPDs. In this poster, I will showcase the operational performance and functionality of LAPPDs in the ANNIE experiment. Neutrino beam data from the BNB is used to evaluate the timing precision, hit reconstruction performance, and beam response of deployed LAPPDs, demonstrating how this novel picosecond-resolution technology performs in a running neutrino water Cherenkov detector. This work highlights the successful integration of LAPPDs in ANNIE and provides quantitative benchmarks that inform their application in future neutrino experiments requiring high-resolution photon detection.

Aman, Mohammad Adil [Florida State U.] (ORCID:0009↗

DEMONSTRATION OF MULTI-PHYSICS EVALUATION OF FUEL ROD BURST PROBABILITY WITH BURNUP EXTENSION UNDER LBLOCA CONDITIONS

Extending the fuel discharge burnup level, e.g., from the current limit of rod averaged discharge burnup limit of 62 GWD/MT to a proposed new limit of 75 GWD/MT, can provide significant economic benefits to the current fleet of operating light water reactors (LWRs). It allows for longer operating cycles and improved resource utilization. The major economic gain of longer operating cycles is attributable to the increased capacity factor resulting from decreased refueling time as a fraction of total operating time, as well as fewer assemblies to be discharged for a given amount of energy produced. The main licensing challenges for higher burnup fuel are to ensure fuel rod safety under design basis accident conditions, especially under large-break loss-of-coolant accident (LBLOCA) and reactivity insertion accident (RIA). In this work, two-year cycle core design for a typical 4-loop pressurized water reactor (PWR) is performed with enrichment increased up to 6% and burnup extended to 75 GWD/MT. The fuel rod burst potential evaluations under large-break loss-of-coolant accident (LBLOCA) conditions are subsequently performed using the multi-physics best estimate plus uncertainty analysis framework LOTUS (LOCA Toolkit for the U.S. LWRs) and the preliminary results are presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Monthly hydropower generation data for Western Canada to support Western-US interconnect power system studies

Hydroelectric power generation in Western Canada significantly contributes to power grid operations of the North American Western Interconnection through substantial generation, some of which is exported to the United States (U.S.). However, the lack of publicly available hydropower generation datasets poses challenges for future market projections and resource adequacy evaluations. We present a simulation-based monthly power system model-ready hydropower generation dataset for 110 facilities in British Columbia and Alberta from 1981 to 2019. These monthly hydropower generation estimates are developed from integrated hydrologic model simulations of runoff and reservoir-operated streamflow, followed by scaling that considers diversion inflow constraints based on hydropower water license information. To address the lack of comparable hydropower generation records, we conduct step-by-step evaluations for simulated runoff, regulated streamflow, and hydropower generation using available observations or estimates. The presented hydropower dataset aims to enhance the representation of hydropower resources in Western Canada, supporting power grid system studies for the Western Interconnection of the U.S. and Canada.

13 HYDRO ENERGY↗

Acid external and internal environment exchange the Oreochromis niloticus tissue immune gene expression compared to the mouse macrophage polarization model

The water environment plays an important role in animal physiology. In this study, we sought to evaluate the effect of the acid environment on the Oreochromis niloticus (Nile tilapia) internal microenvironment immune response compare to the mouse macrophage model (J77A.1). The acid environment treated mouse macrophage J774A.1 model have shown that acidic treatment is able to polarize macrophages into M2-like macrophages via an increase in Ym1, Tgm2, Arg1, Fizz1, and IL-10 expression. Metabolic analysis of mouse macrophages (J774A.1) at pH 2 vs. pH 7 and pH 4 vs. pH 7 have been shown to promote the expression of intracellular acetylcholine, choline, prochlorperazine, L-leucine, and bisphenol A,2-amino-3-methylimidazo[4,5-f] quinolone metabolites in the M2-like macrophage. Immune gene expression of the O. niloticus spleen and liver treated at pH 2, 4, and 7 was shown to reduce TNF-α, IL-1 β, IL-8, and IL-12 expression compared to pH 7 treatment. Immune gene was induced in O. niloticus following culture at pH 5, 6, and 7 fresh water environment. Taken together, we found that the acid internal environment polarizes tissues into an M2 macrophage developmental microenvironment. However, if the external environment is acid, tissues are exposed to an M1 macrophage developmental microenvironment.

59 BASIC BIOLOGICAL SCIENCES↗

Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structures

Highlights: • DC-electrical and dielectric data are combined to estimate concrete saturation degree. • A joint inversion approach of the electromagnetic measurements is proposed. • The sensitivity of the measurements to the saturation model parameters is analysed. • The new joint approach was developed and is applied to synthetic and real data. • The benefits of the joint approach over the inversion of one data type are highlighted. Water saturation profiles in concrete are essential to assess its durability and can be determined using non-destructive techniques, especially the electric and the capacitive methods. In this paper, we propose a new inversion scheme where both resistivity and permittivity measurements are inverted jointly to retrieve the saturation profile. The finite element method is used to model the measurements in 3D, the concrete having a saturation profile with depth, represented by a continuous model taking the form of a Weibull curve with four parameters. A non-linear least-squares optimization based on the Levenberg-Marquardt scheme is developed for the inversion of measurements. Results show that information gathered from both measurements enriches the reconstructed profile, leading to a more reliable estimation of saturation profiles. We believe that the joint inversion method herein developed could lead to the study of more complex phenomena, such as the coupled water-chloride ingress.

36 MATERIALS SCIENCE↗

Carbon sequestration into lime-stabilized soils: Engineering and mineralogical characterization

Stabilizing weak clayey soils with lime is an effective method for improving the mechanical properties of soil. However, lime production is an energy-intensive process producing significant CO 2 emissions in lime-stabilized soils, which can be counteracted through accelerated carbonation that enhances its engineering performance. The present study evaluates accelerated carbonation of lime-treated soils by adding gaseous (CO 2 -rich gas), liquid (water-CO 2 mixture), and solid (sodium bicarbonate) CO 2 sources. Results indicated that samples carbonated with gaseous CO 2 exhibited 100% lime carbonation, while samples treated with solid and aqueous sources of CO 2 had a mean lime carbonation of 60% and 40%, respectively. Further, all lime-treated-carbonated samples exhibited a mean 50% increase in unconfined compressive strength compared to the untreated samples after a 7-day curing period. Durability evaluation through cyclic wetting and drying indicated that the carbonated samples had higher durability than the untreated samples. X-ray computed tomography showed that adding solid and liquid sources of CO 2 facilitated the flocculation of montmorillonite, reducing the porosity. However, a higher dosage of solid CO 2 induced clay dispersion, increasing the porosity. X-ray diffraction and thermogravimetric analysis verified CO 2 sequestration through the formation of calcite, a thermodynamically stable polymorph of calcium carbonate.

58 GEOSCIENCES↗

Underground sources of drinking water chemistry changes in response to potential CO 2 leakage

The purpose of this study was to quantify changes to underground sources of drinking water (USDW) quality in response to potential CO 2 leakage from geologic CO 2 sequestration (GCS) reservoirs. Here, the developed a framework of combined laboratory experiments and reactive transport simulations and used this framework to evaluate the Ogallala aquifer overlying the Farnsworth Unit (FWU), an active GCS site, as a case study. Using chemical reaction parameters obtained from laboratory experiments and numerical simulations, site-specific mechanisms of CO 2 -water-sediment interactions at the USDW aquifer were interpreted. Long-term risks of potential CO 2 leakage were then evaluated with field-scale numerical models using the regional hydrogeological characteristics and reaction parameters obtained from our experiments and simulations. Results suggest that carbonate mineral impurity and cation exchange are key mechanisms for interactions between CO 2 and the aquifer sediment. Additionally, for a large leakage rate of 0.1 % injection from one leaky well, the leakage plume might impact an area of 300 m in diameter and significantly affect the local water quality by changing pH and cation concentrations (e.g., Zn, Ba and Sr). After leakage ceases, the zone of impacted fluids would not migrate significantly in subsequent decades due to a low regional groundwater flowrate (for this case study). The relatively small area of impact might not be detected in a monitoring well given the broader spacing in a typical field scenario. Effective early leakage detection may require additional tools, e.g., borehole CO 2 movement, four-dimensional seismicity, CO 2 soil flux, samples from deeper aquifers, etc., to ensure effective leakage detection and long-term safety of GCS projects.

58 GEOSCIENCES↗

Computational and experimental study of different brines in temperature swing solvent extraction desalination with amine solvents

Rapid global urbanization and high-salinity wastewater disposal from industrial activities have exerted significant pressure on water resources. Over the past few years, temperature swing solvent extraction (TSSE) has been identified as a promising technique to desalinate hypersaline brines. Despite its potential, the TSSE desalination literature has been mainly based on empirical insights, and the limited molecular simulation studies have primarily focused on NaCl brines. Herein, we use molecular dynamics (MD) simulations to study the TSSE desalination of four different brines, namely, KCl, KBr, NaCl, and NaBr using diisopropylamine as the solvent. Based on both bulk and interfacial brine-diisopropylamine MD results, here we investigate the qualitative and quantitative performance of the simulations by benchmarking these results against our experimental evaluations of these same systems. MD results provide satisfactory qualitative agreement with the experimental data of water solubilization in the organic phase and amine solubilization in the aqueous phase for the KBr, KCl, and NaBr brines. Also, the molecular mechanism of solvation of ionic species by water molecules over diisopropylamine suggested by the MD simulations is in agreement with our experimental data. However, larger qualitative and quantitative deviations were observed for the NaCl brines, and this is likely due to polarization and charge transfer effects, as quantified by our quantum chemical calculations.

42 ENGINEERING↗

Fluorine-Free Precise Polymer Electrolyte for Efficient Proton Transport: Experiments and Simulations

Designing polymers with controlled nanoscale morphologies and scalable synthesis is of great interest in the development of fluorine-free materials for proton-exchange membranes in fuel cells. This study focuses on a precision polyethylene with phenylsulfonic acid branches at every fifth carbon, p5PhSA, with a high ion-exchange capacity (4.2 mmol/g). The polymers self-assemble into hydrophilic and hydrophobic co-continuous nanoscale domains. In the hydrated state, the hydrophilic domain, composed of polar sulfonic acid moieties and water, serves as a pathway for efficient mesoscopic proton conductivity. The morphology and proton transport of p5PhSA are evaluated under hydrated conditions using in situ X-ray scattering and electrochemical impedance spectroscopy techniques. Additionally, at 40 °C and 95% relative humidity, the proton conductivity of p5PhSA is 0.28 S/cm, which is four times greater than Nafion 117 under the same conditions. Atomistic molecular dynamics (MD) simulations are also used to elucidate the interplay between the structure and the water dynamics. The MD simulations show strong nanophase separation between the percolated hydrophilic and hydrophobic domains over a wide range of water contents. The percolated hydrophilic nanoscale domain facilitates the rapid proton transport in p5PhSA and demonstrates the potential of precise hydrocarbon-based polymers as processible and effective proton-exchange membranes.

36 MATERIALS SCIENCE↗

Groundwater characterization and monitoring at a complex industrial waste site using electrical resistivity imaging

A contaminated industrial waste site in Washington State (USA) containing buried, metallic-waste storage tanks, pipes, and wells, was evaluated to determine the feasibility of monitoring groundwater remediation activities associated with an underlying perched aquifer system using electrical resistivity tomography. The perched aquifer, located ~65 m below ground surface and ~10 m above the regional water table, contains high concentrations of nitrate, uranium, and other contaminants of concern from past tank leaks and intentional releases of wastes to surface disposal sites. The extent of the perched water aquifer is not well known, and the effectiveness of groundwater extraction for contaminant removal is uncertain, so supplemental characterization and monitoring technologies are being evaluated. Numerical simulations of subsurface flow and contaminant transport were performed with a highly resolved model of the hydrogeologic system and waste site infrastructure, and these simulations were used as the physical basis for electrical resistivity tomography modeling. The modeling explicitly accounted for metallic infrastructure at the site. The effectiveness of using surface electrodes versus surface and horizontal subsurface electrodes, for imaging groundwater extraction from the perched water aquifer, was investigated. Although directional drilling is a mature technology, its use for electrode emplacement in the deep subsurface under a complex industrial waste site via horizontal wells has not yet been demonstrated. Results from this study indicate that using horizontal subsurface electrode arrays could significantly improve the ability of electrical resistivity tomography to image deep subsurface features and monitor remediation activities under complex industrial waste sites.

54 ENVIRONMENTAL SCIENCES↗

From K‐O 2 to K‐Air Batteries: Realizing Superoxide Batteries on the Basis of Dry Ambient Air

Abstract Although using an air cathode is the goal for superoxide‐based potassium‐oxygen (K‐O 2 ) batteries, prior studies were limited to pure oxygen. Now, the first K‐air (dry) battery based on reversible superoxide electrochemistry is presented. Spectroscopic and gas chromatography analyses are applied to evaluate the reactivity of KO 2 in ambient air. Although KO 2 reacts with water vapor and CO 2 to form KHCO 3 , it is highly stable in dry air. With this knowledge, rechargeable K‐air (dry) batteries were successfully demonstrated by employing dry air cathode. The reduced partial pressure of oxygen plays a critical role in boosting battery lifespan. With a more stable environment for the K anode, a K‐air (dry) battery delivers over 100 cycles (>500 h) with low round‐trip overpotentials and high coulombic efficiencies as opposed to traditional K‐O 2 battery that fails early. This work sheds light on the benefits and restrictions of employing the air cathode in superoxide‐based batteries.

Qin, Lei↗

A Porous Crystalline Nitrone-Linked Covalent Organic Framework

Herein, we report the synthesis of a nitrone-linked covalent organic framework, COF-115, by combining N, N', N', N'''-(ethene-1, 1, 2, 2-tetrayltetrakis(benzene-4, 1-diyl))tetrakis(hydroxylamine) and terephthaladehyde via a polycondensation reaction. In this study, the formation of the nitrone functionality was confirmed by solid-state 13 C multi cross-polarization magic angle spinning NMR spectroscopy of the 13 C-isotope-labeled COF-115 and Fourier-transform infrared spectroscopy. The permanent porosity of COF-115 was evaluated through low-pressure N 2 , CO 2 , and H 2 sorption experiments. Water vapor and carbon dioxide sorption analysis of COF-115 and the isoreticular imine-linked COF indicated a superior potential of N-oxide-based porous materials for atmospheric water harvesting and CO 2 capture applications. Density functional theory calculations provided valuable insights into the difference between the adsorption properties of these COFs. Lastly, photoinduced rearrangement of COF-115 to the associated amide-linked material was successfully demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bioelectrochemical reactor to manage anthropogenic sulfate pollution for freshwater ecosystems: Mathematical modeling and experimental validation

Anthropogenic sulfate loading into otherwise low-sulfate freshwater systems can cause significant ecological consequences as a biogeochemical stressor. To address this challenge, in situ bioremediation technologies have been developed to leverage naturally occurring microorganisms that transform sulfate into sulfide rather than implementing resource-intensive physio-chemical processes. However, bioremediation technologies often require the supply of electron donors to facilitate biological sulfate reduction. Bioelectrochemical systems (BES) can be an alternative approach for supplying molecular hydrogen as an electron donor for sulfate-reducing bacteria through water electrolysis. Although the fundamental mechanisms behind BESs have been studied, limited research has evaluated the design and operational parameters of treatment systems when developing BESs on a scale relevant to environmental systems. Further, this study aimed to develop an application-based mathematical model to evaluate the performance of BESs across a range of reactor configurations and operational modes. The model was based on sulfate transformation by hydrogenotrophic sulfate-reducing bacteria coupled with the recovery of solid iron sulfide species formed by the oxidative dissolution of dissolved ferrous iron from a stainless steel anode. Sulfate removal closely corresponded to the rate of electrolytic hydrogen production and hydraulic residence time but was less sensitive to specific microbial rate constants. The mathematical model results were compared to experimental data from a pilot-scale BES tested with nonacidic mine drainage as a case study. The close agreement between the mathematical model and the pilot-scale BES experiment highlights the efficacy of using a mathematical model as a tool to develop a conceptual design of a scaled-up treatment system.

54 ENVIRONMENTAL SCIENCES↗

Quantifying pH buffering capacity in acidic, organic-rich Arctic soils: Measurable proxies and implications for soil carbon degradation

Dynamic pH change promoted by biogeochemical reactions in Arctic tundra soils can be a major control on the production and release of CO 2 and CH 4 , which contribute to rising global temperatures. Large quantities of soil organic matter (SOM) in these soils are susceptible to microbial decomposition, leading to pH changes during permafrost thaw. Soil pH buffering capacity (β) modulates the extent of pH change but has not been thoroughly studied and represented in predictive ecosystem scale biogeochemical models in Arctic tundra soils. In this study, we generated titration curves for 21 acidic tundra soils from three Arctic sites across northern Alaska, United States of America. Geochemical and hydrological soil properties were evaluated, and correlations with β were developed. Strong correlations between β and both gravimetric water content (Θ g ) (R 2 = 0.847, p < 0.001) and soil water retention (SWR) (R 2 = 0.849, p = 0.001) indicate that the ability of soil to retain water could be associated with its buffering properties. Correlations between β and soil organic carbon (SOC) and cation exchange capacity (CEC) were also explored, and relationships to SWR are discussed. These correlations were then used with existing soil databases reporting SOC, CEC, and SWR to estimate β across Alaska soils. We further demonstrated the quantitative relationships between β and the simulated rates of biogeochemical reactions and show that lower β leads to higher soil pH and more CH 4 production. Overall, our study provides simple proxies for β in Arctic soils and highlights the importance and implications of representing soil buffering in predictive models, thereby enabling quantitative coupling between pH dynamics associated with biogeochemical reactions. Integrating β into predictive models of Arctic biogeochemical cycling may reduce model uncertainty and further our understanding of permafrost SOM degradation accelerated by warming.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molecular Iodine Interactions with Metal Substrates: Towards the Understanding of Iodine Interactions in the Environment Following a Nuclear Accident

In order to evaluate the potential impacts to the public from radioiodine in a nuclear event, it is vital to expand our understanding of the interaction of molecular iodine with various surfaces. There are many potential surfaces that iodine could interact with in and around a nuclear facility, including stainless steel. This study, carried out at ambient temperature, pressure and humidity, demonstrates the highly adsorptive nature of molecular iodine on two types of austenitic stainless steel, 304L and 316L. In the authors review of available literature, Fe is the only metal in stainless steel that is assumed to react with gas-phase molecular iodine. By using a novel approach which combines Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) with surface Energy Dispersive X-ray Spectroscopy (EDS) there is evidence of the formation of metal iodides that have not previously been verified or quantified. Samples exposed to gaseous molecular iodine formed an iodine containing corrosion product visible by scanning electron microcopy (SEM). Evaluation of the metals in the corrosion region using EDS was compared to a water leach of the same samples analyzed using ICP-OES. A comparison of the results provide evidence that the water leachate is representative of the corrosion layer and not the base material. Furthermore, it provides confirmation of metal iodide formation with minor stainless-steel constituents including: FeI2, NiI2, MnI2 and CrI2.

Beck, Chelsie L.↗