Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visual system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Expansion of the Fuel Motion Monitoring System

The Idaho National Laboratory (INL) Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System (FMMS) is a diagnostic tool used to visualize the movement and location of fuel within the nuclear reactor during transient experiments. TREAT is designed to test the behavior of nuclear fuel under accident conditions, such as a rapid power increase. The TREAT FMMS, also referred to as the “hodoscope” because of the system’s massive steel collimator component, is located on the North beam port of the reactor. While the FMMS system is capable of incorporating a total of 360 sensors, initial refurbishment efforts resulted in a array of 96 fast neutron detectors. This initial array was configured to provide a narrow (2 channels) full-length view of experiment vessels with an extended 4-channel–wide region in the center of the array capable of providing a full view of all initially planned experiments. Planning and efforts to expand the FMMS array began immediately following the restart of TREAT. An additional 96 detectors were evaluated, characterized, and prepared for installation at TREAT during the summer of 2018. Unfortunately, funding reductions forced the project towards a 5-year hiatus. In October of 2023 funding from the Department of Energy’s Nuclear Science User Facilities enabled the expansion to recommence. This report serves to document the activities performed to expand the FMMS detector array to 192 channels in order to provide a broader view of the larger and more sophisticated test capsules currently planned for future irradiation in the TREAT reactor. This expansion also included doubling the data acquisition capability, addressing the new heat load on the system, and synchronizing the time for all digital components.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding large scale HPC systems through scalable monitoring and analysis.

As HPC systems grow in size and complexity, diagnosing problems and understanding system behavior, including failure modes, becomes increasingly difficult and time consuming. At Sandia National Laboratories we have developed a tool, OVIS, to facilitate large scale HPC system understanding. OVIS incorporates an intuitive graphical user interface, an extensive and extendable data analysis suite, and a 3-D visualization engine that allows visual inspection of both raw and derived data on a geometrically correct representation of a HPC system. This talk will cover system instrumentation, data collection (including log files and the complications of meaningful parsing), analysis, visualization of both raw and derived information, and how data can be combined to increase system understanding and efficiency.

99 GENERAL AND MISCELLANEOUS↗

Repulsive tip tilting as the dominant mechanism for hydrogen bond-like features in atomic force microscopy imaging

Experimental atomic force microscopy (AFM) studies have reported distinct features in regions with little electron density for various organic systems. These unexpected features have been proposed to be a direct visualization of intermolecular hydrogen bonding. Here, we apply a computational method using ab initio real-space pseudopotentials along with a scheme to account for tip tilting to simulate AFM images of the 8-hydroxyquinoline dimer and related systems to develop an understanding of the imaging mechanism for hydrogen bonds. We find that contrast for the observed “hydrogen bond” feature comes not from the electrostatic character of the bonds themselves but rather from repulsive tip tilting induced by neighboring electron-rich atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗

Development of a mobile toolmark characterization/comparison system [Development of a mobile, automated toolmark characterization/comparison system]

Since the development of the striagraph, various attempts have been made to enhance forensic investigation through the use of measuring and imaging equipment. This study describes the development of a prototype system employing an easy-to-use software interface designed to provide forensic examiners with the ability to measure topography of a toolmarked surface and then conduct various comparisons using a statistical algorithm. Acquisition of the data is carried out using a portable 3D optical profilometer, and comparison of the resulting data files is made using software named “MANTIS” (Mark and Tool Inspection Suite). The system has been tested on laboratory-produced markings that include fully striated marks (e.g., screwdriver markings), quasistriated markings produced by shear-cut pliers, impression marks left by chisels, rifling marks on bullets, and cut marks produced by knives. Using the system, an examiner has the potential to (i) visually compare two toolmarked surfaces in a manner similar to a comparison microscope and (ii) use the quantitative information embedded within the acquired data to obtain an objective statistical comparison of the data files. Finally, this study shows that, based on the results from laboratory samples, the system has great potential for aiding examiners in conducting comparisons of toolmarks.

47 OTHER INSTRUMENTATION↗

First application of liquid-metal-jet sources for small-animal imaging: High-resolution CT and phase-contrast tumor demarcation

Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.

60 APPLIED LIFE SCIENCES↗

Low-voltage scanning electron microscopy of multilayer polymer systems

The possibilities of low-voltage scanning electron microscopy for visualization of specific features of the microstructure in internal layers of multilayer polymer films are demonstrated by the example of “chitosan–polyelectrolyte complex–alginic acid” composite. The process of electron beam interaction with a sample at low electron energies is considered. The key parameters of low-voltage electron microscopy, which make it possible to increase the resolution of SEM images of polymer systems, are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interactive Visualization of Complex Seismic Data and Models Using Bokeh

Visualizing multidimensional data and models becomes more challenging as the volume and resolution of seismic data and models increase. But thanks to the development of powerful and accessible computer systems, a model web browser can be used to visualize complex scientific data and models dynamically. In this paper, we present four examples of seismic model visualization using an open-source Python package Bokeh. One example is a visualization of a surface-wave dispersion data set, another presents a view of three-component seismograms, and two illustrate methods to explore a 3D seismic-velocity model. Unlike other 3D visualization packages, our visualization approach has a minimum requirement on users and is relatively easy to develop, provided you have reasonable programming skills. Finally, utilizing familiar web browsing interfaces, the dynamic tools provide us an effective and efficient approach to explore large data sets and models.

58 GEOSCIENCES↗

SU-E-T-465: Implementation of An Automated Collision Detection Program Using Open Source Software for the Pinnacle Treatment Planning System

Purpose: Potential collisions between the gantry head and the patient or table assembly are difficult to detect in most treatment planning systems. We have developed and implemented a novel software package for the representation of potential gantry collisions with the couch assembly at the time of treatment planning. Methods: Physical dimensions of the Varian Edge linear accelerator treatment head were measured and reproduced using the Visual Python display package. A script was developed for the Pinnacle treatment planning system to generate a file with the relevant couch, gantry, and isocenter positions for each beam in a planning trial. A python program was developed to parse the information from the TPS and produce a representative model of the couch/gantry system. Using the model and the Visual Python libraries, a rendering window is generated for each beam that allows the planner to evaluate the possibility of a collision. Results: Comparison against heuristic methods and direct verification on the machine validated the collision model generated by the software. Encounters of <1 cm between the gantry treatment head and table were visualized as collisions in our virtual model. Visual windows were created depicting the angle of collision for each beam, including the anticipated table coordinates. Visual rendering of a 6 arc trial with multiple couch positions was completed in under 1 minute, with network bandwidth being the primary bottleneck. Conclusion: The developed software allows for quick examination of possible collisions during the treatment planning process and helps to prevent major collisions prior to plan approval. The software can easily be implemented on future planning systems due to the versatility and platform independence of the Python programming language. Further integration of the software with the treatment planning system will allow the possibility of patient-gantry collision detection for a range of treatment machines.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualization of Multi-Dimensional Imaging Data for the DIII-D National Fusion Facility

With funding provided from the Office of Fusion Energy Science’s program on Diagnostic Systems for Magnetic Fusion Energy Sciences, the PI and his team have pioneered the development of microwave imaging systems for magnetic fusion plasma diagnostics. Specifically, electron cyclotron emission (ECE) imaging [1], a passive radiometric technique, measures electron temperature fluctuations; and microwave imaging reflectometry (MIR) [2], an active radar imaging technique, measures electron density fluctuations. These microwave imaging diagnostic instruments developed by UC Davis have made important contributions to fusion science in a relatively short period of time from their original installation on DIII-D. The microwave imaging diagnostic technique has matured considerably since the beginning of a fruitful collaboration with DIII-D and PPPL, and has also been adopted at preeminent tokamak facilities worldwide. As discussed in detail in the following, this has continued with the development of revolutionary microwave diagnostic instruments employing monolithic millimeter wave integrated circuit (MMIC) system-on-chip (SoC) technology. Specifically, “chip” receivers mounted in liquid crystal polymer (LCP) modules have been demonstrated to dramatically improve the performance of the electron cyclotron emission imaging (ECEI) system including: 30x improvement in noise temperature thereby permitting absolute 2-D electron temperature images, outstanding shielding against out-of-band interference including microwave bursting which had plagued previous ELM studies using the old quasi-optical mini-lens ECEI system, and independent modules facilitating flexible repair and replacement. Under the “Visualization of multi-dimensional imaging data for the DIII-D National Fusion Facility” program, funding was provided for a research scientist postdoc and a Ph.D. student to support physics studies at DIII-D employing these instruments. This endeavor is synergistic with our current grant under the DOE Fusion Energy Sciences (FES) program on Diagnostic Systems for Magnetic Fusion Energy Sciences. This support considerably increased the scientific output of the diagnostics. The activities were strongly focused in the areas of pedestal and ELM stability, energetic particle confinement, and the early detection and avoidance of tokamak disruptions employing the microwave imaging diagnostic instruments developed under the advanced diagnostics program where imaging of the ELM crash was made possible by the elimination of the interference from the associated microwave “bursts”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Knowledge Discovery for Smart Grid Operation, Control, and Situation Awareness -- A Big Data Visualization Platform

In this paper, a big data visualization platform is designed to discover the hidden useful knowledge for smart grid (SG) operation, control and situation awareness. The spawn of smart sensors at both grid side and customer side can provide large volume of heterogeneous data that collect information in all time spectrums. Extracting useful knowledge from this big-data poll is still challenging. In this paper, the Apache Spark, an open source cluster computing framework, is used to process the big-data to effectively discover the hidden knowledge. A high-speed communication architecture utilizing the Open System Interconnection (OSI) model is designed to transmit the data to a visualization platform. This visualization platform uses Google Earth, a global geographic information system (GIS) to link the geological information with the SG knowledge and visualize the information in user defined fashion. The University of Denver's campus grid is used as a SG test bench and several demonstrations are presented for the proposed platform.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Science of Analytic Reporting

The challenge of visually communicating analysis results is central to the ability of visual analytics tools to support decision making and knowledge construction. The benefit of emerging visual methods will be improved through more effective exchange of the insights generated through the use of visual analytics. This paper outlines the major requirements for next-generation reporting systems in terms of eight major research needs: the development of best practices, design automation, visual rhetoric, context and audience, connecting analysis to presentation, evidence and argument, collaborative environments, and interactive and dynamic documents. It also describes an emerging technology called Active Products that introduces new techniques for analytic process capture and dissemination.

97 MATHEMATICS AND COMPUTING↗

A Typology of Decision-Making Tasks for Visualization

Despite decision-making being a vital goal of data visualization, little work has been done to differentiate decision-making tasks within the field. While visualization task taxonomies and typologies exist, they often focus on more granular analytical tasks that are too low-level to describe large complex decisions, which can make it difficult to reason about and design decision-support tools. In this paper, we contribute a typology of decision-making tasks that were iteratively refined from a list of design goals distilled from a literature review. Our typology is concise and consists of only three tasks: CHOOSE, ACTIVATE, and CREATE. Although decision types originating in other disciplines exist, we provide definitions for these tasks that are suitable for the visualization community. Our proposed typology offers two benefits. First, the ability to compose and hierarchically organize the tasks enables flexible and clear descriptions of decisions with varying levels of complexities. Second, the typology encourages productive discourse between visualization designers and domain experts by abstracting the intricacies of data, thereby promoting clarity and rigorous analysis of decision-making processes. We demonstrate the benefits of our typology through four case studies, and present an evaluation of the typology from semi-structured interviews with experienced members of the visualization community who have contributed to developing or publishing decision support systems for domain experts. Our interviewees used our typology to delineate the decision-making processes supported by their systems, demonstrating its descriptive capacity and effectiveness. Finally, we present preliminary findings on the usefulness of our typology for visualization design.

97 MATHEMATICS AND COMPUTING↗

Dynamic visualization of data streams

One embodiment of the present invention includes a data communication subsystem to receive a data stream, and a data processing subsystem responsive to the data communication subsystem to generate a visualization output based on a group of data vectors corresponding to a first portion of the data stream. The processing subsystem is further responsive to a change in rate of receipt of the data to modify the visualization output with one or more other data vectors corresponding to a second portion of the data stream as a function of eigenspace defined with the group of data vectors. The system further includes a display device responsive to the visualization output to provide a corresponding visualization.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Changes in lipid bilayer structure caused by the helix-to-sheet transition of an HIV-1 gp41 fusion peptide derivative

HIV-1, like other enveloped viruses, undergoes fusion with the cell membrane to infect it. Viral coat proteins are thought to bind the virus to the membrane and actively fuse the viral and cellular membranes together. The actual molecular mechanism of fusion is challenging to visualize, resulting in the use of model systems. In this paper, the bilayer curvature modifying properties of a synthetic variant of the HIV-1 gp41 fusion peptide with lipid bilayer vesicles composed of a mixture of dimyristoyl phosphatidylcholine (DMPC) and dimyristoyl phosphatidylserine (DMPS) were studied. In 7:3 DMPC:DMPS vesicles made with deuterium-labeled DMPC, the peptide was observed to undergo a concentration-dependent conformational transition between an α-helix and an antiparallel β-sheet. Through the use of small-angle neutron scattering (SANS) and selective deuterium labeling, it was revealed that conformational transition of the peptide is also accompanied by a transition in the structure of the lipid bilayer. In addition to changes in the distribution of the lipid between the leaflets of the vesicle, the SANS data are consistent with two regions having different thicknesses. Finally, of the two different bilayer structures, the one corresponding to the smaller area fraction, being ~8% of the vesicle area, is much thicker than the remainder of the vesicle, which suggests that there are regions of localized negative curvature similar to what takes place at the point of contact between two membranes immediately preceding fusion.

59 BASIC BIOLOGICAL SCIENCES↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗