Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variational analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Computed Tomography Scanning and Geophysical Measurements of Core from the Boggess 17H Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize the Marcellus Shale and underlying formations. The core is from a vertical pilot well (Boggess 17H) drilled in western Monongalia County near Core, West Virginia by Northeast Natural Energy for the second Marcellus Shale Energy and Environmental Laboratory (MSEEL). MSEEL is a joint venture between NETL, Northeast Natural Energy, and West Virginia University. The primary impetus for this report is to characterize the core to better understand the structure and variation of the Marcellus Shale and surrounding formations. This report, and the associated scans, provide detailed datasets not typically available from unconventional shales for analysis.

58 GEOSCIENCES↗

Observationally driven Resource Assessment with CoupLEd models (ORACLE)

This project seeks to carry out a multifaceted analysis combining buoy observations, machine learning, turbulence, satellite data and high-resolution modeling. Our analyses will investigate air–sea interaction physics governing the variation of the winds with height and influence of clouds, uncertainty in coupled ocean-wave-atmosphere mesoscale models to capture certain key atmospheric phenomenon observed over the U.S. West Coast, impact of climate change, and the fidelity with which resource characterization models describe the range of observed offshore wind conditions. This project will focus its efforts on characterizing and assessing the atmospheric and oceanographic conditions along the U.S. West Coast.

Wind, Energy↗

Machine-Learning Functional Zonation Approach for Characterizing Terrestrial–Aquatic Interfaces: Application to Lake Erie

Ecosystems at coastal terrestrial–aquatic interfaces play a significant role in global biogeochemical cycles. In this study, we aimed to characterize coastal wetlands with particular focus on the co-variability between plant dynamics, topography, soil, and other environmental factors. We proposed a functional zonation approach based on machine learning clustering to identify the spatial regions, i.e., zones that capture these co-varied properties. This approach was applied to publicly available datasets along Lake Erie, in the Great Lakes Region. We investigated the heterogeneity of coastal ecosystem structures as a function of along-shore distance and transverse distance, based on the spatial data layers, including topography, wetland vegetation cover, and the time series of Landsat’s enhanced vegetation index (EVI) between 1990 and 2020. Results showed that the topographic metrics (elevation and slope), soil texture, and plant productivity influence the spatial distribution of wetland land-covers (emergent and phragmites). These results highlight a natural organization along the transverse axis, where the elevation and the EVI increase further away from the coastline. In addition, the clustering analysis allowed us to identify regions with distinct environmental characteristics, as well as the ones that are more sensitive to interannual lake-level variations.

47 OTHER INSTRUMENTATION↗

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Design Variations in Beetle Elytra

Abstract Beetles typically use their protective wing coverings or elytra to shield their membranous hindwings from the environment. Elytra in some terrestrial species have evolved a greater protective role capable of shielding the organism from powerful antagonistic predators. The structure–function relationships of these biological composites identify how architectural and chemical variations of the cuticle are tuned to create light‐weight, impact resistant composites. Specifically, the elytral structures of a tree dwelling beetle capable of flight, Trypoxylus dichotomus , and a terrestrial beetle incapable of flight, Phloeodes diabolicus , are compared to understand how their varied environmental needs forged the elytra to facilitate fight or resist fatal predator strikes. Mechanical and microstructural analysis reveals P . diabolicus has a harder, stiffer elytra that incorporate through‐thickness fibers to resist greater mechanical stresses imposed by bending and puncture. Conversely, the elytra of T . dichotomus have a compliant structure with large voids that facilitates localized deformation. Variations in flexural strength and puncture resistance remain attributed to P . diabolicus possessing a thicker cuticle with a greater degree of cross‐linking and an increased amount of endocuticular layers. These findings may provide useful insight into the design and manufacturing of composite materials for use in light‐weight or energy‐absorbing applications.

Rivera, Jesus↗

Dynamic Differential Image Circle Diameter Measurement Precision Assessment: Application to Burning Droplets

Dynamic measurement precision assessment has been achieved for a differential circle measurement application. Differential circle diameter measurement, in image analysis, typically requires fitting a circle model that optimizes for image distortions, defects or occlusions. The differential task occurs when precise measurements of diameter change are required given object size variation with time. An automated system was designed to provide diameter measurements and associated measurement precision of images of a fuel droplet undergoing combustion in zero gravity for the FLEX-2 dataset. An image gradient-based, least-squares boundary point fitting method to a circle or ellipse model is used for diameter measurement. The presence of soot aggregates poses significant challenges for diameter measurements when it occludes part of the droplet boundary. The precision of the diameter measurements depends upon the image quality. Using synthetic image simulations that model the soot behavior, we developed a model based on image quality measures that assesses the measurement precision for each individual diameter measurement. Thus, diameter measurements with precision assessments were made available for follow-up scientific analysis. As a result, the algorithm's success rate for measurable runs was 98%. In cases of limited occlusion, a measurement precision of ±0.2 pixels for the FLEX-2 dataset was achieved.

42 ENGINEERING↗

Modern analogs for understanding pollen-vegetation dynamics in a Mediterranean mosaic landscape (Balearic Islands, Western Mediterranean)

This paper presents the study of modern pollen analogs from the Balearic Islands. While similar studies have been largely applied to mainland areas, research focused on modern vegetation dynamics on Mediterranean islands remains very rare. In this research, we combine vegetation surveys, pollen analysis and multivariate statistics to understand landscape composition. The main objectives of are: (1) to examine pollen-vegetation relationships in relation to environmental and land-use variables; (2) to understand modern pollen representation in a mosaic landscape structure; and (3) to propose pollen indicators that characterize the primary vegetation types from the Balearic Islands to better interpret past pollen records in Mediterranean island environments. Pollen results and Redundancy Analysis (RDA) distinguish three major groups: (a) Holm oak and box formations; (b) maquis and garrigues; and (c) anthropogenic and open habitats. Landscape form, mean decadal rainfall, mean decadal temperature, fire activity, trampling, slope percentage, wet/flooded soil, saline soil, distance to agropastoral cells, gHM index, domestic herbivory presence, agropastoral use, and soil type are the major variables explaining modern pollen assemblage variation in our research. Poaceae undiff., Plantago sp., Apiaceae undiff., Cerealia-t, and Cichorieae are highly correlated to human activities but should be interpreted cautiously when occurring in low values. Quercus ilex-t, Hypericum, and Buxus are correlated to humid locations while Pistacia, Pinus, Juniperus-t, and Olea to high mean decadal temperatures. Our study indicates how pollen analysis and multivariate analysis are powerful tools for characterizing the mosaic landscape, with special focus on the main vegetation types of the Balearic Islands.

Geology↗

Dark Energy Survey Year 3 results: Simulation-based cosmological inference with wavelet harmonics, scattering transforms, and moments of weak lensing mass maps. II. cosmological results

Here, we present a simulation-based cosmological analysis using a combination of Gaussian and non-Gaussian statistics of the weak lensing mass (convergence) maps from the first three years of the Dark Energy Survey. We implement the following: (1) second and third moments; (2) wavelet phase harmonics; (3) the scattering transform. Our analysis is fully based on simulations, spans a space of seven 𝑤 Cold Dark Matter (𝑤⁢ CDM) cosmological parameters, and forward models the most relevant sources of systematics inherent in the data: masks, noise variations, clustering of the sources, intrinsic alignments, and shear and redshift calibration. We implement a neural network compression of the summary statistics, and we estimate the parameter posteriors using a simulation-based inference approach. Including and combining different non-Gaussian statistics is a powerful tool that strongly improves constraints over Gaussian statistics (in our case, the second moments); in particular, the figure of merit (𝑆 8 , Ω m ) is improved by 70% (Λ ⁢CDM) and 90% (𝑤 ⁢CDM). When all the summary statistics are combined, we achieve a 2% constraint on the amplitude of fluctuations parameter 𝑆 8 ≡ 𝜎 8 ⁢(Ω m /0.3) 0.5 , obtaining 𝑆 8 = 0.794 ±0.017 (Λ⁢ CDM) and 𝑆 8 = 0.817 ±0.021 (𝑤 ⁢CDM), and a ∼10% constraint on Ω m , obtaining Ω m =0.259 ±0.025 (Λ ⁢CDM) and Ω m = 0.273 ±0.029 (𝑤⁢ CDM). In the context of the 𝑤⁢ CDM scenario, these statistics also strengthen the constraints on the parameter 𝑤, obtaining 𝑤 <−0.72. The constraints from different statistics are shown to be internally consistent (with a 𝑝-value>0.1 for all combinations of statistics examined). We compare our results to other weak lensing results from the first three years of the Dark Energy Survey data, finding good consistency; we also compare with results from external datasets, such as planck constraints from the cosmic microwave background, finding statistical agreement, with discrepancies no greater than <2.2⁢𝜎.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the weighted shifted boundary method for the Poisson and Stokes problems

The Shifted Boundary Method (SBM) belongs to the class of unfitted (or immersed, or embedded) finite element methods, and relies on reformulating the original boundary value problem over a surrogate (approximate) computational domain. Accuracy is maintained by properly shifting the location and values of the boundary conditions. This avoids integration over cut cells and the associated implementation issues. Recently, the Weighted SBM (WSBM) was proposed for the Navier-Stokes equations with free surfaces and the Stokes flow with moving boundaries. The attribute “weighted” in the name WSBM stems from the fact that its variational form is weighted with the elemental volume fraction of active fluid. The motivation for the development of the WSBM was the preservation of the volume of active fluid to a higher degree of accuracy, which in turn resulted in improved stability and robustness characteristics in moving-boundary, time-dependent simulations. In this article, we present the numerical analysis of the WSBM formulations for the Poisson and Stokes problems. We give mathematical conditions under which the bilinear forms defining the discrete variational formulations are uniformly coercive (Poisson problem) or inf-sup stable (Stokes problem). By these results, stability and optimal convergence is proven in the natural norm; L2-error estimates can also be derived.

Approximate domain boundaries↗

Techno-Economic Case Study: Fermentation Cost Impacts from Selected Critical Material Attributes

This report summarizes analysis conducted to support a case study under the Feedstock-Conversion Interface Consortium (FCIC) focused on techno-economic analysis (TEA) modeling to quantify the economic implications of biomass hydrolysate substrate variability on fermentation performance and resultant biorefinery fuel yields. It is known that fermentation inhibitors or byproducts, as may either come from constituents in the biomass feedstock or imparted through biorefinery processing operations, can detrimentally impact fermentation rates and yields. However, it is often difficult to isolate fermentation impacts to individual components given the complex nature of biomass varying simultaneously in multiple attributes from one lot to another. For this study, we worked with FCIC researchers to obtain data on key fermentation performance metrics, namely productivity rates and conversion yields, across a number of material attribute species previously selected by the researchers as "critical" attributes which may be found in hydrolysate used as microbial carbon sources during fermentation. These data were run through TEA models to estimate resultant impacts on biorefinery economics, reported as minimum fuel selling price (MFSP). Overall, the trends in MFSP closely followed fuel yields, in turn tied to fermentation process yields and selectivity, with minimal economic impact from variations in fermentation productivity.

09 BIOMASS FUELS↗

On the Impact of Income, Age, and Travel Distance on the Value of Time

The value of time (VOT) is a fundamental component used in transportation modeling, policy analysis, and economic appraisal. Decades of research and practice have empirically estimated the VOT across many factors (e.g., mode, purpose, time, comfort, etc.), yet little is known about its underlying form. Although it is well established that VOT can vary, it is still unclear whether patterns exist in this variation. The objective of this paper is not to merely estimate the VOT, but to model the VOT across multiple continuous and interacting variables. The purpose is to reveal its functional form with respect to mode, age, gender, purpose, income, and time of day to provide a generalizable understanding for future research and practice. Such an understanding can help develop simpler models and reduce the need for bespoke estimations for every conceivable variable perturbation. This research utilized a household travel survey containing 14,159 reported trips with imputed travel time and costs for the alternative mode choices. The average overall estimated VOT is 40.32 $/h, with results showing VOT varying log-linearly with income and trip distance, but following a Gaussian function (normal curve) with age. Overall, the results show that travel distance dominates VOT variation, which increases exponentially at a rate that is 3.61 times higher per mile of distance than per $10,000 of income, and that VOT by age peaks at age 54. This basic understanding of how the VOT varies sets the foundation for answering the subsequent question for why it might vary.

Engineering↗

Evaluating the Feasibility of Measuring and Analyzing Strain Caused by Changes in Barometric Pressure in the Vadose Zone

Changes in barometric pressure propagate into the subsurface where they can affect water level measurements in wells and cause vertical strain. Previous strain sensors were developed to measure vertical strain, but they were limited to measurements at a single depth, making it difficult to evaluate strains from a migrating pressure wave. Technology known as Coherence-length-gated Microwave Photonics Interferometry (CMPI) uses optical fiber sensors to measure strain at multiple locations. It has the potential to detect strain caused by variations in barometric pressure at multiple depths in the subsurface. The goal of this study is to evaluate the feasibility of using this technology to record the changes in vertical strain in the vadose zone from small fluctuations in air pressure. Propagation of these air pressure fluctuations is affected by hydrogeological properties such as water content and permeability. A second goal of this study is to evaluate how these properties affect the air pressure distribution, strain, and gas-phase diffusivity with a long-term goal of using strain to monitor the vadose zone. The focus of this study is on a suite of laboratory experiments that used a sand-filled column with an open head space. The CMPI fiber was packaged and embedded along the axis of the column to measure the strain at multiple locations while air pressure transducers were installed through the wall of the column. Small periodic fluctuations in air pressure, similar to barometric pressure fluctuations, were created in the head space of the column using an audio driven speaker driven at 4 Hz using a sinusoidal signal created by a function generator. Then, the fluctuations propagated along the column where they were measured by the transducers and recorded as functions of time. Initial tests were conducted using dry sand, but then additional tests were conducted after injecting water into the column, which changed the hydrologic and mechanical properties. Another experiment was conducted after creating a thin barrier to air flow, which was designed to simulate a thin layer of saturated ground during rainfall. A final experiment was conducted by changing the grain size of the material to create a heterogeneity in the upper half of the column. The suite of six experiments was conducted to highlight effects of variations in water content and heterogeneities on air pressure and vertical strain. Numerical simulations were also created to evaluate the laboratory data and to provide a baseline analysis for the results. The numerical simulations used the governing equations to linear poroelasticity and two-phase flow with boundary conditions representing the experiments. The conceptual model for strain caused by barometric pressure recognizes that a fluctuating barometric pressure causes fluctuations in the air pore pressure that decrease in amplitude and lag in time with increase depth. The pressure distribution results in two different loads that cause strain: 1.) a mechanical load as the barometric pressure acts on the ground surface; and 2.) pressure loading in the pore space. The results show that the total vertical strain is a contribution of both of these loads, and this is the strain that was observed in the laboratory. The lab experiments show that both air pressure and strain vary as sinusoids that propagate with depth. The amplitude of the air pressure and strain decrease as a function of depth in all the conditions that were evaluate. For example, in the dry sand, the amplitude of the air pressure decreases from 25 Pa at the head space to 5 Pa at a depth of 70 cm, whereas the amplitude of the strain decreases from 0.15 to 0.06 µε over the same depth interval. In many cases the amplitudes decrease is approximately negative exponential functions of depth. When water was injected into the sand and the saturation increased, the amplitude of the air pressure increased in the partially saturated sand but decreased sharply to zero where the soil was saturated. The strain decreased with depth, but the transition from partially to fully saturated conditions had little effect on the strain profile, even though it had a major effect on the air pressure. This apparently is because strain is caused by variations in both water and air pressure. The fluctuating air pressure caused the water pressure to fluctuate, which caused strain throughout the column. Phase delay of the air pressure and the strain both increase as linear to bi-linear functions of depth. The phase delays indicate that pressure propagates at a velocity of 7 to 8 m/s in dry or partially saturated sand, but it drops by more than an order of magnitude in the vicinity of the capillary fringe. The phase delays indicate the strain propagates faster than the pressure. The data indicate that the strain propagates from 1.2 to more than 4x faster than the pressure. Switching from sand to silt in the column caused the velocity of the pressure to drop by roughly half for both pressures, but curiously, it had little effect on the velocity of the strain.

54 ENVIRONMENTAL SCIENCES↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Floating Photovoltaic System Cost Benchmark: Q1 2021 Installations on Artificial Water Bodies

In this report, we conduct a bottom-up analysis of the installed costs for FPV systems deployed on artificial water bodies under average site conditions (wind load of about 40 m/s, snow load of 20 psf, water depth of 50 m, water level variation of 10 m, and swell height of 1 m). We estimate an installed system cost premium of $\$0.26$/WDC (25%) for 10-MWDC fixed-tilt FPV systems, compared with ground-mounted, fixed-tilt PV installed over bare ground. Higher structural costs related to the floats and anchoring system are the largest contributors to this premium. Currently, site investigation costs are also higher for FPV because of the additional effort needed to plan and design these more complex installations. Our preliminary sensitivity analysis shows that the installed cost of FPV systems is most sensitive to float costs, wind and snow loading, and module efficiency. FPV deployment is in an early stage, and additional experience, best practice development, and new configurations and technologies could help reduce the costs of FPV systems over time.

14 SOLAR ENERGY↗

Analysis of radially resolved thermal conductivity in high burnup mixed oxide fuel and comparison to thermal conductivity correlations implemented in fuel performance codes

The thermal diffusivity and thermal conductivity of high burnup (19 % FIMA) mixed oxide (U, Pu)O 2 nuclear fuel has been measured along the radial direction using a thermoreflectance-based method. Measured thermal conductivity exhibits a notable radial variation consistent with the expectations that a large temperature gradient across the annular fuel pellet leads to a heterogeneous microstructure. A common fuel performance model of thermal conductivity, the Lucuta-Inoue model, is used to analyze the measured thermal conductivity profile. Further, this model adequately captures the radial dependence of thermal conductivity except in the periphery. The analysis suggests that the characteristic radial shape of the thermal conductivity profile follows the burnup profile within the fuel pin. In the periphery, the high burnup structure is formed and the conductivity model, not capturing this effect, likely overestimates the thermal conductivity.

36 MATERIALS SCIENCE↗

Analysis of Loss-of-Offsite-Power Events: 2021 Update

Loss-of-offsite power (LOOP) can have a negative impact on a nuclear power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study were based on the operating experience during calendar years 1987–2021, while the most recent 15-year data (i.e., from 2007–2021) were used for most analyses in this report. LOOP events during critical operation that did not result in a reactor trip are not included. Frequencies and durations were determined for four LOOP event categories: plant-centered, switchyard-centered, grid-related, and weather-related. These categories (and the All-LOOPs group which contains all LOOPs without regarding of the four categories) could be further grouped by whether a LOOP event occurred during critical operation, during shutdown operation, or during all operations. The following decreasing trends in the LOOP occurrence rates were identified for the most recent 10-year period (2012–2021): All-LOOPs during critical operation, switchyard-centered LOOPs during critical operation, and grid-related LOOPs during critical operation. Adverse trends in LOOP durations continue for switchyard-centered LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during shutdown operation for the 1997–2021 period. Statistical tests show the LOOP counts for the period of 2007–2021 are not uniformly distributed across the 12 months, and variation among the months exists for grid-related LOOPs during all operations, All-LOOPs during all operations, and All-LOOPs during critical operation. The engineering analysis of LOOP data showed for the period of 2007–2021, the equipment failure events were dominated by failures of relay and other; human errors have been less frequent and occurred primarily in maintenance and switching; and weather were dominated by tornadoes then by lightning and hurricane. Weather was the cause for 45% of LOOPs for the last fifteen years (2007– 2021) but only for 20% of LOOPs for the previous 20 years (1987–2006) .

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Variational Method for Analyzing Vortex Flows in Radar-Scanned Tornadic Mesocyclones. Part III: Sensitivities to Vortex Center Location Errors

Abstract When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an important issue concerning the sensitivities of analyzed vortex flow (VF) fields by the VF-Var (formulated in Part I of this paper series and tested in Part II) to vortex center location errors, denoted by Δ x c . Numerical experiments are performed to address this issue with the following findings: The increase of |Δ x c | from zero to a half of vortex core radius causes large analysis error increases in the vortex core but the increased analysis errors decrease rapidly away from the vortex core especially for dual-Doppler analyses. The increased horizontal-velocity errors in the vortex core are mainly in the Δ x c -normal component, because this component varies much more rapidly than the other component along the Δ x c direction in the vortex core. The vertical variations of Δ x c distort the vertical correlation structure of Δ x c -dislocated VF-dependent background error covariance, which can increase the analysis errors in the vortex core. The dual-Doppler analyses have adequate accuracies outside the vortex core even when |Δ x c | increases to a half of vortex core radius, while single-Doppler analyses can also have adequate accuracies outside the vortex core mainly for the single-Doppler-observed velocity component. The sensitivities to Δ x c are largely unaffected by the vortex slanting. The above findings are important and useful for assessing the accuracies of analyzed VFs for real radar-observed tornadic mesocyclones. Significance Statement When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an issue concerning the sensitivity of analyzed vortex flow (VF) by the VF-Var (formulated in Part I of this paper series and tested with simulated radar observations in Part II) to vortex center location error. This issue and its required investigations are very important for the VF-Var to be applied to real radar-observed tornadic mesocyclones, especially in an operational setting with the WSR-88Ds. Numerical experiments are performed to address this issue. The findings from these experiments are important and useful for assessing the accuracies of VF-Var analyzed VF fields for real radar-observed tornadic mesocyclones.

Xu, Qin↗