Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmission deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 829 records · Page 46

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Angular Resolution Imaging of Solar Radio Bursts from the Lunar Surface

Locating low frequency radio observatories on the lunar surface has a number of advantages, including positional stability and a very low ionospheric radio cutoff. Here, we describe the Radio Observatory on the lunar Surface for Solar studies (ROLSS), a concept for a low frequency, radio imaging interferometric array designed to study particle acceleration in the corona and inner heliosphere. ROLSS would be deployed during an early lunar sortie or by a robotic rover as part of an unmanned landing. The preferred site is on the lunar near side to simplify the data downlink to Earth. The prime science mission is to image type II and type III solar radio bursts with the aim of determining the sites at and mechanisms by which the radiating particles are accelerated. Secondary science goals include constraining the density of the lunar ionosphere by measuring the low radio frequency cutoff of the solar radio emissions or background galactic radio emission, measuring the flux, particle mass, and arrival direction of interplanetary and interstellar dust, and constraining the low energy electron population in astrophysical sources. Furthermore, ROLSS serves a pathfinder function for larger lunar radio arrays. Key design requirements on ROLSS include the operational frequency and angular resolution. The electron densities in the solar corona and inner heliosphere are such that the relevant emission occurs below 10 M Hz, essentially unobservable from Earth's surface due to the terrestrial ionospheric cutoff. Resolving the potential sites of particle acceleration requires an instrument with an angular resolution of at least 2 deg at 10 MHz, equivalent to a linear array size of approximately one kilometer. The major components of the ROLSS array are 3 antenna arms, each of 500 m length, arranged in a Y formation, with a central electronics package (CEP) at their intersection. Each antenna arm is a linear strip of polyimide film (e.g., Kapton(TradeMark)) on which 16 single polarization dipole antennas are located by depositing a conductor (e.g., silver). The arms also contain transmission lines for carrying the radio signals from the science antennas to the CEP. Operations would consist of data acquisition during the lunar day, with data downlinks to Earth one or more times every 24 hours.

MacDowall, Robert J.↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Validation of Interconnection and Interoperability of Grid-Forming Inverters Sourced by Hydrogen Technologies in View of 100% Renewable Microgrids

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

controller hardware-in-the-loop↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Solar Adoption in Orlando: A Household-Level Model for Distribution Resource Planning

Potential for rooftop solar in Florida is massive (47% of retail sales, 3rd overall nationally), yet adoption lags (12th nationally). A 2018 Florida Public Service Commission ruling authorizing solar third-party ownership (leasing) has substantially increased attention on distributed solar in the state. The city of Orlando has committed to a 100% clean-energy target by 2050 and deployment of solar and storage are expected to contribute significantly to reaching the goal. Deployment of customer-adopted solar, unlike utility-procured solar, is uncertain, but known to be spatially correlated with demographic factors and existing adoption. We develop a new method to adapt NREL's dGen model in order to represent building-level agents in adoption forecasts for the Orlando Utility Commission (OUC) service territory. Using the agent-based model we develop projections of solar adoption, subject to scenarios varying future solar costs and valuation, and aggregate adoption predictions by OUC distribution feeder. We find substantial spatial heterogeneity in the projected level of adoption by OUC distribution feeder. For instance, 25% of all projected adoption through 2050 would be concentrated on just 5% of feeders and 88% of projected adoption on 50% of feeders. Because of the uncertainty in adoption, bottoms-up solar adoption forecasting methods at the household-level are integral to long-term resource planning by anticipating system needs as customers increasingly adopt distributed solar, storage, electric vehicles, and other distributed energy resources.

14 SOLAR ENERGY↗

Blockchain for Fault-Tolerant Grid Operations

Radial topology and vast geographic coverage make distribution systems prone to widespread power outages upon the failure of a single (or multiple) upstream component. Fault-handling algorithms depend heavily on correct estimations of the system’s state to effectively isolate the affected area and reduce the number of affected customers while maintaining operational safety. The work described here leverages the core features of distributed, consensus-based decision-making processes and the immutability of blockchain, and demonstrates their value in improving fault-tolerant grid operations. In this work, blockchain was used to create a trusted data-sharing platform that enables independent actors to reconstruct the system state; this enables distributed resources to make intelligent decisions with limited knowledge. Although the process requires data sharing, its algorithms have been designed to limit the amount of private information that is exchanged, which helps preserve business-sensitive data and maintain customer privacy. In addition, by reducing the information that must be shared, the communication requirements are also reduced; (however, an in-depth analysis of the communication requirements is beyond the scope of this project). The proposed use cases are intended to represent a foundational basis for third parties to develop functional solutions that can eventually be deployed in the field. To further provide guidance, the envisioned use cases have incorporated design requirements that consider the blockchain characteristics and a need to limit information from surrounding resources, which preserve the assumption and the possibility that such resources could belong to different entities. This report presents a detailed design of the three use cases with the tools needed to enable the analysis being tested. The implemented gross error detection method can detect mismatches when the error exceeds 3.8 times the sensor’s rated accuracy. Detection of the circuit breaker state successfully identified the correct states across all simulation tests. A distribution-system power-flow solution in the simulator OpenDSS generally possesses a convergency tolerance of 0.01% on the voltage magnitude. The evaluation of possible reconnection using voltage magnitude—preserving the data ownership—has a voltage magnitude difference smaller than 0.001% from the OpenDSS result. The results preserving data ownership have a difference within the expected power flow tolerance with full knowledge of the system, which surpasses expectations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Power-Hardware-in-the-Loop Evaluation of Inverter-Based Resources (IBRs)

Power-hardware-in-the-loop evaluation of IBRs has become more and more important as it provides reliable testing results to investigate the real responses of inverters with interconnected systems. A successful laboratory PHIL testing gives confidence of the hardware system to be deployed and de-risk technology integration prior to field deployment. So far, there are two important applications for PHIL evaluation: (1) test stability and functionality of large utility inverters into the system when it interconnects to the distribution systems/microgrids; and (2) test the collective grid service that inverters can provide to the grid. For the first application, the PHIL evaluation has high requirements for the stability and accuracy of the PHIL interface as the close-loop in digital real time simulator (DRTS) should replicate the actual current and voltage dynamics in the inverter. This is challenging because of the delays, sensing errors, nonlinearities of inverters, and hardware bandwidth limitations of the elements in the HIL loop. For the second application, multiple inverters will be tested resulting in multiple PCCs, which naturally causes competing dynamics and oscillations among hardware inverters if traditional PHIL interface is used. Therefore, new PHIL interface should be developed to compromise between stability and accuracy and represent the dispatched grid services for the hardware inverters. In this presentation, we will share our latest work in developing PHIL interface in these two applications to address the two key challenges.

DERMS↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Storage Response to Utility Tariff Structures and Potential Use of Capacity Charges

Energy storage is increasingly being deployed in behind-the-meter use cases, partially in response to falling lithium-ion prices and new utility tariff structures. Utilities are grappling with new tariff design in the presence of distributed energy resources (DER), trying to motivate, fairly price the contribution of, and, in some cases, discourage, certain operation of DER. There are opportunities for energy storage under emerging tariff structures, but utility net load management objectives for storage remain unclear. Diverse tariff structures motivate the use of energy storage to provide one or a combination of: energy arbitrage, energy shifting, solar self-consumption, and import shaving. This paper formulates a linear optimization to demonstrate the optimal storage tariff response, examining customer net load metrics under diverse utility tariff structures, such as time-of-use, net metering, feed-in tariffs, zero export tariffs, and demand charges. A key contribution of this paper is the introduction and examination of a capacity charge as mechanism that can both motivate reductions in both peak import, and exports, along with greater load levelling.

behind-the-meter↗

Clean Energy Cybersecurity Accelerator: Cohort 2 - runZero Public Report

The U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) sponsors the Clean Energy Cybersecurity Accelerator™ (CECA) to expedite the deployment of emerging security technologies that address the most urgent security concerns facing modern and future electric grids. CECA Cohort 2 assessed solutions focused on hidden risks due to incomplete system visibility and device security and configuration. Improving visibility can be achieved through operational technology (OT) asset identification solutions, including capabilities like automatic discovery, vulnerability reporting, and configuration monitoring. Solutions that monitor and identify assets in information technology (IT) networks in other domains are widely used; however, there is far less adoption of monitoring solutions for operational technology environments. Wider adoption may increase with increased confidence in the ability for these solutions to understand and respond to the specific requirements of OT environments. CECA Cohort 2 evaluated the active and passive asset discovery capabilities of market-ready solutions, documented and analyzed results, and identified gaps in functionality or capabilities. This report and describes how these results can help advance the adoption of these and similar solutions in the electric sector.

24 POWER TRANSMISSION AND DISTRIBUTION↗